ML20035A436
| ML20035A436 | |
| Person / Time | |
|---|---|
| Issue date: | 01/26/1993 |
| From: | Grimsley D NRC OFFICE OF ADMINISTRATION (ADM) |
| To: | Klingbeil R AFFILIATION NOT ASSIGNED |
| Shared Package | |
| ML20033D829 | List: |
| References | |
| FOIA-92-522 NUDOCS 9303260055 | |
| Download: ML20035A436 (2) | |
Text
v.x i, vo,,,,-. u n u w.. w v ai
..,m
%u s m.
i 4
FOIA -
Q 1, - S 2 2
- l.r.s%.
vV nse sa mt o
i T
j VMj RESPONSE TO FREEDOM OF yJ m l l mmt b
4
\\
/
INFORMATION ACT (FOIA) REQUEST 6"
JAN 2 6 1993 pol.A l I *k, ft P tst fi? M:p:i. 3?dP;
^
Q j
t h[/
(.
3
'Y PART 1.-AGEffY hECORDS RELE ASED OR NOT LOCATED (See cher eett to w 4
No erncy ret orrs sab;ect to the requmt have bhen loca'ed.
No add.t av agenc y records sub;ect to tr.e eauest ha.e been ot ated Regoested mords ce a.aJab e through another pubhc ds rebute prog *am See Comments section.
Ag"ncy recyds s.tyect to the reauest that are ident Aed m Abnend n 'ed ar e a N 3d y ai cad'e br ps * '< msaert or and topy:ng at the S,RC Putmc D:cament Room. 2120 L Street. NK. Aas4ng*o* DC.
3 Agency recores sutint to the rewest that 6 e idetd'eo in Appe nJ.x f 65 h.
are bemg r. 3.de ewir:at 'e fo pub c irispr< tion anrj copying at the N AC PSc E xument Room. 2120 L Street. ? W. Ns hron. DC en a fo:d< r under tu f OI A number The nom eoprietry.ersion of the propos#st that you ag ee d to m ce: t,n a :( phone convers: mon eth e re-bs e cf my staff es noe, be:rg enade adaWe f or pubut msa-ci r, and c opy mg at 'br N RC Pubhc Do:omet Room 2120 i Street, N W, WasNngton DC. m a fccdar unoer Ws F 01 A nu+nber Arney tecyds ss Mct to t*>t reouest that ye irtentif:ed in App ia4 rm t e mspe:ted and ap+d at !be N F Loca Pubhc Drurnent Room dennf ed n the Comment, section.
4 E ntbs d :s v format.or, on how you may obtarr, c.u css w anet r < c*.. :rs f ar cop,'r.g records iocated at the NHC Fm: Docume~t Room. 2120 L Street, NW nashe son, DC Agenc y records sA;ect to t e reauest art endosed h
Records sh;ect L the request hue becn re' erred to anoiner Fn era ey nines) for reora an.1 d.rer resarse to you f
Fees N ou el be bred by the N"C f or fees totahng S You e i retewe a refund fro the N RC in TN amount c' E In sew ef r.RC s respo st +c tras rea-est. no further act on is N ng in en on an o siter dated Na PART 11. A-INFORMATION WITHHELD FROM PUBLIC DISCLOSURE Certam.MorTation M the rmested recorcs is being a chht !d f rc r. pubut d sclosu e pursuant to t"e et emenc as des: ted in and ior tee reasons stated r
in Part 11. B C and D. Ar, remased portions of the drumerts 4ce a w onb part of t*.e ruord is ber-g a e we re beng mace avaasue to putmc Mspectie anc _ opy rg in tne NRC Pub.c Docun + t R oom 2120 L 5 reet. N W. herg'on, DC in a f older unner t +os F OI A rwmt.,re,
COW E NT S The enclosed records are identified on the enclosed Appendix A.
+You are not tie i n g assessed pirocessing fees since the minimal fee limit has not been exceeded.
^
se unE. omf clo u.isioN or & a toore or istonv Anon va n E uca1 tons se nvicts J
6 N%4 (1,M r
n 9303260055 930126 PDR FOIA KLINGBE92-522 PDR
~
dPP
_~
l
'.j FOIA 92-522 i
APPDOIX A - RDEASE i
- 1. 2/19/87 G. Iainas, NRC, to L Pfefferlen,GE,
Subject:
Review of i
1EE-20996 (P) " Safer Mx3els for Evaluation of loss-of-Coolant Accident for Jet Pump and Non-Jet Pu:ip Plants, Vol. I and II" 14 pgs j
- 2. 5/11/87 A. 'Ihadani, NBC, to H. Pfefferlen, GE,
Subject:
Acceptance Ebr l
Referencing of Licensing 'Ibpical Peport IEE-30996(P) Vol. II
" Safer Fbdel for Evaluation of Ioss-of-Coolant Accidents for Jet and Non-Jet hrp Plants" 13 pgs 3.
5/29/84 R. W. Houston, NIC, to F. Miraglia, NBC,
Subject:
Safety Eval-
{
uation Report on General Electric ECCS Evaluation Fethodology i
4.
6/1/84 Letter from Thomas to Quirk
Subject:
Acceptance fo00Rgfysrencing l
^' Licensing Topical Report NEDE-23785 Revision 1, Volume 111 (P),
ae GESTR-LOCA and SAFER Models for the Evaluation of the Loss-of-1 Coolant Accident".
(2 pages) t
,t i
i la i
-l':
'l i
2 i
l i
I i
l
_