Requests Executive Branch Position on Encl Application for License to Export Nuclear Fuel Assembly Components,Control Rods & Control Rods Components to Czech Republic
ML20034H260
Person / Time
Issue date: 03/12/1993
From: Hauber R
NRC OFFICE OF INTERNATIONAL PROGRAMS (OIP)
To: Thorne C
STATE, DEPT. OF, BUREAU OF OCEANS & INTL. ENVIRONMENT
References
NUDOCS 9303160286
Download: ML20034H260 (1)


Text

'

e.,

^

ug4'o.

=

h

.a e

. UNITED STATES

,.' g g

NUCLEAR REGULATORY COMMISSION a

j e E WASHINGTON, D. C. 20555

\\.,,.. *#(I 4

-i MAR 121993 1

Mr. Carlton E. Thorne, Director

~

Office of Nuclear Export Control Bureau of Oceans and International Environmental and Scientific Affairs U.S. Department'of State Washington, D.C.

20520

Dear Mr. Thorne:

Enclosed is an export license application from Westinghouse Electric Corporation,.

dated March 4,1993, for the export of fuel assembly components including,: but not -limited to, fuel tubes,. instrumentationf tubes,- springs, nozzles,. grids, heater rods, spiders; and, control rods and control rod components, including but '

1 not limited to, rodlets, hubs, spiders' and other various' control rod components for use in testing and evaluation of fuel assembly components, control rods,.and control rod components for VVER application in the Czech Republic. - The total value of this export is estimated at $1,000,000.

Before; taking - action on.' this request, we would appreciate. your obtaining '

necessary assurances under Section 109 of the Act and receiving your views, from' the overall perspective of the Executive Branch, as 'to whether. the proposed-export meets the other applicable criteria in the Atomic Energy Act of 1954.as' amended by the Nuclear Non-Proliferation Act of 1978.

Sincerely,-

l b

I Ronald D. Hauber,L Assistant Director Exports, Security, and Safety Cooperation Office of International Programs

Enclosure:

[

Appl..dtd. 03/04/93 (XCOM1078 - Czech Republic)

+

cc w/

Enclosure:

R. DeLaBarre, DOS T. Hart, DOE-R. Goorevich, DOE t

S. Dhir, DOC j

G. Brubaker, D0D M. Rosenthal, ACDA i

l j

1 6 0 1 8..

9303160286 930312 PDR XPORT XCOM-1078 PDR

((l s

1 F CTA.1 fCC.7 US.f!uCLEAR RE!UL4 TORY COMM13380N Appp,;ygD BY CAD

  • fo^c*r'a iso APPLICATION FOR LICENSE TO EXPORT NUCLEAR MATERIAL AND EQUIPMENT Is Interuccons on Aewsel j ubMaa wo.M/D78

/ brT ii.

.. AraucA=T ausmauca 3. NRc

1. Ar*uCANT s p OAT: ce A ucAT o=

X ust Parch 4. 1003 WSH-93-070 ust

2. AreuC ANT s Nuet uso Aoo=Ess

{ Ris

( sureutR s NAME ANo acoREss j Ris

Hudar FrW

'>4 R

. =Aus Northern Pike & Haymaker Road Westinghouse Commercial Nuclear Fuel Divisio

e. sTasar Accasse 1
c. CtTV STATE Zie Coct
n. ST AE ET ADOPEES Monroeville PA 15146 5801 Bluff Road
4. y a sa,-o w. a,= c - e - o v

cit v stata ze coes (412) 374-3262 Columbia SC 29205 L FIRsT SM PutNT L PINAL SHIPMENT 7. APPUCANT 3 CONTRAcTVAL L PROPOSED LICENSE S. UA. CEP ARTMENT OF ENERGY EXPIRATION CATE CONTRACT NO. (#f Knoma#

SCHEDULED SCHEDULED CELiv8RYDATE 4/1/93 6/95 12/31/96

11. ULTIMATE END ust l

ltL ULTIMATE CD433CNEE l Rt3

+

l'"W** *'*"t *' CdV "***I Skoda Koncern - Plzen i

For test and evaluation of fuel assembly NAus components, control rods, and control rod

  • 8"***""**

31600 Plzen.16 components for VVER application.

A ciTv - stara - cov=Tav Czech Republic 11a. Est.oArt or piRev ust

12. INTERMEDIATE CCMs3GNE E lNE
13. INTERMEDIATE END ust l

a,NAME

a. ST R E E T ADO. Ess
s. CATV - ST ATE -CCWhTay 13a EST. D ATE 08 8I.5i Uf,E 1a. INTE RME DI ATE CONSIGNE E l RS

' 18. INTERMEDIATE END USE l

haws aL ST A E ST AD D R EES

s. C4TY - STATE - COUNTRY lla. EsT. DATE OF FIRsT UsE IL
17. DESCRIPTIOM 1L MAK. ELEMENT 1L MAX. 23. MAX 21.

re ca, ca

,,,,,a

, e

.r -,

re wEicxT wT.s esotoet wi.

unit NRc r

USE nuema.wom.ar aw c.wa

~.

Fuel assembly components including, but not limited to, fuel tubes, instrumentation tubes, j

springs, nozzles, grids, heater rods, spiders,

&y

.'?

etc.

Control rods and control rod components g

including, but not limited to, rodlets, hubs,

-L s

spiders, etc.

(

(

.j Total value: $1,000,000.

22, covN7arof csuc3Nrsuu I

i 2a. covNTaits wnics ATTAcn 1

(h sounen MATE ntAL, x2. coVNTnY cm oniciN.-

I

st;teg gitnacxEnon enooucEc, g s4sssa44 sis.pr.,5y.2 3/,

- - = -

=__. r Not Applicable

..Not AppT1 cable

~

25. ADQ1TIONAL INFoRMATION (L,,e s.o.vm swer,f asemary/

Due to the near-term shipment requirements, it would be appreciated if the NRC would d

expedite the issuance of this license. These comptments will not be sold to the

'4 Ultimate Consionee but provided to Skoda for test and evaluation on CNFD behalf.

m 1,.

- ~

_,,T r,....c R

~ ~. _,.

27' AuTwoniz1D erriciAt

n. sicNATu
n. T TLE k ao re s/.uv

/

-f i

i.

/

U g/CCe o m o s7

/

38 Westinghouse Energy Systems Box 355 Electric Corporation Pmsburgh Pennsykania 15?30-0355 WSH-93-070 Marrh 4,1993 Mr. Ronald D. Hauber, Assistant Director International Security, Exports and Material Safety Of! Ice ofInternational Programs 11555 Rockville Pike Mall Station WF13-H 5 U.S. Nuclear Regulatory Commission Rockville, MD 20852

Subject:

Export Application

Dear Mr. Hauber:

Please find enclosed a license application a>vering the proposed export of nuclear fuel assembly components (no source or special nuclear material), control rods and control rod components to the Czech Republic. These products are for test and evaluation for application to VVER reactors.

Due to the near term shipment of these ;m> ducts (i.e., April 1,1993), it would be appreciated if the NRC and other U.S. Government Agencies could expedite the issuance of this license.

A check for $4900 is enclosed covering the fee for this application.

Should you have any questions on this application, please contact the undersigned at (412) 374-3262.

Very truly yours,

/

William S. Hudec Senior License Administrator International Enclosurcs 3.

/%1cJ'drh3

'