ML20034F703

From kanterella
Jump to navigation Jump to search
Amend 1 to Enterprise Rept 162 Re Defect on Starting Air Distributor Housing Assembly,As Followup to 930115 Final Rept.Addl Listed Part Numbers Discovered Which Are Higher Level Assemblies of Housing
ML20034F703
Person / Time
Site: Perry, Harris, Vogtle, San Onofre, Rancho Seco, Shoreham  Southern California Edison icon.png
Issue date: 02/25/1993
From: Schneider J
COOPER INDUSTRIES, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-PT21-93 162, QGC-9331, NUDOCS 9303040158
Download: ML20034F703 (5)


Text

.

Cooper industries Cooper-cossemer Rectprocating Products Divid:n 160 Lincoln Avenue Grove city. PA 16127 1898 412 458-8000 k

February 25,1993 COOPER Cooper Energy Services Our Ref: OCG-9331 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ENTERPRISE REPORT

Subject:

10 CFR Part 21

  1. 162 Starting Air Distributor Housing AMENDMENT #1

Dear Sir:

1 t

On January 15,1993 Cooper-Bessemer Products Division, a division of Cooper Industries issued a final report (our Ref. OCG-9250) conceming a defect on starting air distributor housing assembly.

in addition to the part numbers identified, additional part numbers have been discovered, t

1 A-4560,1 A-4598,1 A-6345,1 A5158, Parts Lists 03-442-02-01, 00-442-08-01, 02-442-740-16, 00-442-08-05 which are higher level assemblies of the housing.

If you have any questions regarding this issue, please contact John R. Schneider, Manager, Quality Assurance at 412-458-3434 or Ron G. Billig, Supervisor of Enterprise Engineering at 412-458-3584.

Sin erely,

/

~ ohn R. Schneider Manager, Quality Assurance and Nuclear Operations cc:

B. R. Sedelmyer - CES/GC A. D. Gillette - CES/GC D. T. Blizzard - CES/GC J. M. Home - CES/GC R. G. Billig-CES/GC J. A. Manno - CES/ Alameda B. C. Guntrum ~- CES/ Alameda R. L. Nimmo - CES/ Alameda' i

Lee Duck - CES/ Alameda S. S. OwYoung - CES/ Alameda 0an015 J. R. Andrews - CES/ Alameda

/

R. A. Johnston - CES/ Alameda

- '/

I

(,

D'

[$$$ yyy i

c nr.s......r ~.cos. w...e.nu-PDR

Pige 2 OCG-9331 1

February 25,1993 j

i i

cc:

Walter Haass - NRC One White Flint North l

Mailstop 9D4 Washington, DC. 20555 J

i Entergy Operations P. O. Box 429 Echelon One 1340 Echelon Parkway Jackson, MS 39286-1995 Attn:

T. H. Cloninger Vice Pres. Nucl. Eng.

Manager, Quality Services Entergy Operations Box 756 Port Gibson, MS 39150 l

Phone: 601-437-6712 i

Vice President, Operations

+

Entergy Operations Box 756 Port Gibson, MS 39150 Phone: 601-437-6409 i

Entergy i

P. O. Box 429 Port Gibson, MS 39150 Attn: Fred Titus Dir., Nuclear Plant Eng.

i Entergy

{

P. O. Box 756 Port Gibson, MS 39150 Attn; Vice Pres., Nuclear Operations j

i Entergy P. O. Box 756 i

Port Gibson, MS 39150 Attn:

D.L. Pace l

Design Engineering Carolina Power and Light Co.

Shearon Harris Nuclear Project P. O. Box 165 New Hill, NC 27562 i

Attn:

Dept. Mgr.

i t

Pdge 3.

~

OCG-9331 February 25,1993 Carolina Power and Ught Co.

Harris Nuclear Project-P. O. Box 165 New Hill, NC 27562 Attn:

Mr. C. S. Hinnant Plant Gen. Mgr.

I Carolina Power and Ught Co.

l P. O. Box 1551 Raleigh, NC 27602 Attn:

R. A. Watson Sr. Vice President Carolina Power and Ught Co.

Shearon Harris Nuclear Project P. O. Box 1551 Raleigh, NC 27602 i

Attn:

S. D. Floyd Mgr. Nuclear Licensing Carolina Power and Ught Co.

Shearon Harris Nuclear Project P. O. Box 165 New Hill, NC 27562 Attn: Mr. O.C. Olexik-Mgr. of Regulatory Committee Carolina Power and Ught Co.

Shearon Harris Nuclear Plant

+

P. O. Box 165 New Hill, NC 27562 Attn: Jerry R. Cribb Mgr, Ouality Control Cleveland Electric it!uminating Perry Nuclear Power Plant P. O. Box 97 I

Perry, OH 44081 l

Attn:

M. Lister i

Cleveland Electric liluminating f

Perry Nuclear Power Plant P. O. Box 97 Perry, OH 44081 l

Attn:

Russell J. Tadych Manager, Quality Control i

.. j

]

Pige 4 OCG-9331 February 25,1993 -

Cleveland Electric illuminating Perry Nuclear Power Plant P. O. Box 97 Perry, OH 44081 Attn:

Harold M. Coon Cleveland Electric illuminating Co.

I clo Perry Nuclear Power Plant 10 Center Road North Perry, OH 44081 Attn:

Supv. Procurement Quality Unit, PNPP 1

Cooper-Enterprise Clearinghouse Duke Engiraering & Service 230 South Tryon St.

P.O. Box 1004 Charlotte, NC. 28201-1004 Attn:

Mike Anthony Duke Power Co.

Nuclear Generation Dept.

P. O. Box 1007 Charlotte, NC 28201-1007 Attn:

Mgr., Nuclear Safety i

Duke Power Co.

Nuclear Generation Dept.

J P. O. Box 1007 Charlone, NC 28201-1007 Attn:

W. T. Robertson Vice President, Procurement Duke Power Co.

Purchasing Department P. O. Box 1002 Charlotte, NC 28201-1002 Attn: Mr. R. F. Smith General Manager, Purchases j

Georgia Power Co.

I Plant Vogtle P. O. Box 1295 Birmingham, AL 35201 Attn:

Mr. T. Green Mgr., Engineering and Ucensing i

L n

Prge5

.OOG-9331 February 25,1993 Georgia Power Co.

Plant Vogtle P. O. Box 1600 Waynesboro, GA 38030 Attn: Mr. W. B. Shipman Gen. Mgr.

Manager, Quality Control Gulf States Utilities P. O. Box 220, MA-3 St. Francisville, LA 70775 Attn:

Director Nuclear Ucensing Long Island Ughting Co.

Shoreham Nuclear Power Station North Country Rd.

Wading River, NY 11792 Attn: Mgr. Nuclear Operat.

Support Dept.

Southem Califomia Edison Co.

San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, CA 92672 Attn:

Manager, Nuclear Oversight Div.

Sacramento Municipal Utility District Rancho Seco Nuclear Power Plant 14440 Twin Cities Road Herald, CA 95638 Attn: Vice Pres. & Gen. Manager Tennessee Valley Authority 1101 Market Street, LP 5B Chattanooga, TN 37402 Attn:

Mr. M. J. Fecht 1

Mgr. Nuclear Experience Review Texas Utilities Electric 400 North Olive Street, LB. 81 Dallas, TX 75201 Attn:

W. J. Cahill Group Vice President Washington Public Power Supply i

P. O. Box 460 Richland, WA 99352 Attn:

Mr. L C. Oakes Manager, WNP-1 Engineer cc:

File K5fa22

.