Submits Results of Engineering Review of Plant Records to Address Issues in NRC Bulletin 90-001,Suppl 1, Loss of Fill Oil in Transmitters Mfg by Rosemount. Actions for Unit 1 Completed & Reporting Requirements Met
ML20034D721
Person / Time
Site: Comanche Peak  
Issue date: 02/19/1993
From: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-90-001, IEB-90-1, TXX-93090, NUDOCS 9302240006
Download: ML20034D721 (3)


Text

..

5bllll =j=

Log- # TXX-93090 File # 10119 8B3 Ref. # NRCB 90-01 Supplement 1 TUELECTRIC February 19, 1993 i

Wimam J. Cahill, Jr.

Gramp Vocc hwdmr U. S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET N05. 50-445 AND 50-446 NRC BULLETIN 90-01 SUPPLEMENT 1,

  • LOSS OF FILL-0IL IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT" Gentlemen:

On December 22, 1992, the NRC issued Bulletin 90-01, Supplement 1.

  • LOSS OF FILL-Olt IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT.* By TV Electric Letter logged TXX-93015 from William J. Cahill, Jr. to the NRC dated January 15, 1993. TU Electric provided a response to Supplement 1 for i

Unit 2.

In response to the bulletin, TV Electric provides that CPSES-Unit 1 has completed the requested actions of Bulletin 90-01, Supplement 1, as described beluw:

As requested by the supplement, an engineering review of plant records was performed to identify any Rosemount Model 1153 Series B. Model 1153 Series D, and Model 1154 transmitters manufactured before July 11, 1989, that are used or may be used in the future in either safety-related systems, or systems installed in accordance with 10CFR50.62 (the ATWS rule).

CPSES Unit I does not have Rosemount transmitters in the Engineered Safety Feature Actuation System (ESFAS), Reactor Protection System (RPS), or Anticipated Transient Without Scram (ATWS) Mitigation System Actuation Circuitry (AMSAC).

The engineering review revealed that, CPSES Unit 1 has fifty-six such safety related transmitters in other applications.

For these transmitters, TV Electric has taken the following actions:

1)

The nine in high pressure (greater than 1500 psi) applications have been included in the Unit 1 Rosemount Transmitter Monitoring Program with a requirement for quarterly surveillance on each transmitter until the transmitter is replaced.

12 200E,0 hl ggg22g0g 7,gggg,,

O.

PDR 400 N. Onve Street LB. E ! Da!!as, Texas 75201

-j

TXX-93090 page 2 of 2 l

2)

The twenty-two in medium pressure (greater than 500 and less than or equal to 1500 psi) applications have been included in the Unit 1 Rosemount Transmitter Monitoring Program with a requirement for monitoring on a refueling basis (not to exceed 24 months) until the transmitter has met the Rosemount psi-month threshold criterion for a mature transmitter.

Existing plant procedures can detect failures of these transmitters caused by a loss of fill oil.

3)

The twenty-five in low pressure (less than or equal to 500 psi) applications need not be included in the monitoring program.

Existing plant procedures can detect f ailures of these transmitters caused by a loss of fill oil.

i The CPSES Unit 1 Rosemount Transmitter Monitoring Program trends data t

obtained using calibrated test equipment during the normal calibration surveillance cycle. The data gathered has an accuracy and resolution consistent with that needed for comparison with manufacturer drift data criteria for determining degradation caused by a loss of fill oil.

i i

As described above, the actions requested by this supplement for CPSES Unit I have been completed and, via this letter, the reporting requirements of this supplement for CPSES Unit I have been met.

In addition, TU Electric intends to maintain the program described above for as long as the subject transmitters are in use.

TV Electric intends to replace the nine transmitters in high pressure application in a timely and appropriate l

manner.

j If you have any questions please contact J. D. Rodriguez at (214) 812-8674.

I Sincerely,

{

/'

William J. Cahill, Jr.

I JDR/

l Attachment c-Mr. J. L. Milhoan, Region IV Resident Inspectors, CPSES (2)

Mr. T. A. Bergman, NRR Mr. B. E. Holian, NRR i

5

t Attachment to TXX-93090 Page 1 of 1 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION i

In the Matter of

)

)

Texas utilities Electric Company

)

Docket Nos. 50-445

)

50-446 (Comanche Peak Steam Electric

)

Station, Units 1 & 2)

)

AFFIDAVIT I, William J. Cahill..Jr. being duly sworn, hereby deposes and says that I am Group Vice President, Nuclear Production for TV Electric, the licensee herein; that I have full authority to execute this oath; that I have read the foregoing response to NRC BULLETIN 90-01 SUPPLEMENT 1:

  • LOSS OF FILL-0IL IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT" and know the contents thereof; and that to the best of my knowledge, information, and belief the statements made in it are true.

ff )

/

/

c Wil l i am 'J. Ca t(/Il, J r.

- //

- n' t.

x UA

,7

,5 Group Vice President, Nuclear Production 7q _

m.

s.

< o pdTATE OF TEXAS

)

)

COUNTY OF DALLAS )

Subscribed and sworn to before me. on this 14t h day of Februarv

, 1992.

,\\

/

J Nota //Public I

-.