Responds to Re Violations Noted in Insp Rept 50-336/89-13.NRC Does Not Agree That Licensee Complying W/ Intent of Generic Ltr 82-12 Re Hours of Overtime Worked by One Individual.W/Excerpts of Util Records & Inspector Notes
ML20034C021
Person / Time
Site: Millstone 
Issue date: 04/19/1990
From: Hodges M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mroczka E
NORTHEAST NUCLEAR ENERGY CO.
References
GL-82-12, NUDOCS 9005010322
Download: ML20034C021 (15)


See also: IR 05000336/1989013

Text

r. ,. V

.;

.

_

.

.'

APR 191990

l

i

I

Docket No. 50-336

Northeast Nuc1 car Energy Company

ATTN: Mr. E. J. Mroczka

Senior Vice President - Nuclear

l

Engineering and Operations Group

l

P. O. Box 270

Hartford, Connecticut 06141-0270

Gentlemen:

Subject:

Response to Inspection Report 50-336/89-13

This letter is in response to your letter, dated December 8,1989, reference

No. A08300, which responded to Inspection Report 50-336/89-13. We have reviewed.

your actions regarding the Notice of Violation and, with one exception discussed

below, consider them appropriate based on your response.

The acceptability of

your corrective actions will be confirmed at a future inspection. We acknowledge

i

your actions to strengthen the employees concern program and encourage your

I

continued efforts in this area.

With regard to your response to Violation E, we do not agree that you are

complying with the intent of Generic Letter 82-12. The intent of the letter

is to limit the hours of overtime worked by a individual during any successive

I

l

period. The psychological and physiological effects of long hours do not

recognize artificial boundaries imposed by your current policy for. controlling -

i

l

overtime. The effects of working more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in any 48-hour period are-

I

not accounted for in your current practice of controlling only-the consecutive

48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> periods. The Generic Letter is very explicit in requiring controls

spanning any 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> period and the violation is consistent with previous

Office of Nuclear Reactor Regulation positions on this matter; therefore, the

violation stands as cited.

We acknowledge the lack of specificity of the violation, but, considering the

extent to which your records reflect the cited foregoing condition, we believe

it should be easily identifiable from your review. The enclosures to this

letter contain some excerpts-from your records and the inspector's notes that

,

l.

will provide examples of the bases for the violation.

If further examples areL

L

necessary, they are available upon request.

Your cooperation in this matter is appreciated.

Sincerely,

Orichcl 0;ad By:

Marvia W. Ibges

l

l

Marvin W. Hodges, Director

'

Division of Reactor Safety

Enclosures: As stated

0FFICIAL RECORD COPY

R50-333/89-13 - 0001.0.0

g(

04/18/90

9005010322 900419

PDR

ADOCK 05000336

t_ COI

. Q ..

_.

PDC

u

,

.

.

APR 101990

o

,

,

.'

Northeast Nuclear Energy Co.

2

,

cc w/ enc 1:

W. D. Romberg, Vice President, Nuclear Operations

S. E. Scace, Station Superintendent

D. O. Nordquist, Director of Quality Services

R. M. Kacich, Manager, Generation Facilities Licensing

>

D. B. Miller, Station Superintendent, Haddam Neck

Gerald Garfield, Esquire

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of Connecticut

bec w/ enc 1:

Region I Docket Room (with concurrences)

.

R. Bellamy, DRSS

DRP Section Chief

J. Shediosky, SRI, Haddam Neck

W. Raymond, SRI, Millstone 3

D. Jaffe, LPM, NRR

J. Dyer, EDO

.

.

sh

hhhy

RI:DRS

RI:0RS T

I:DRS

Durr

Blumberg

Hodges

4//4 /90

4//h/90

4//f/90

0FFICIAL RECORD COPY

R50-333/89-13 - 0002.0.0

04/13/90

m

'

.

.

.

'

'

.

.

4

'

MILLSTONE UNIT 2

OVERTIME AUDIT OF MAINTENANCE

i

Tardif

26 1/2 on 2/6-7/89

2/8-2/9 overtime approval signed on 2/10/89

Gardner

24 1/2 on 2/9-10

!

Fowler

24 1/2 on 2/14-15

Thoma

25 1/2 on 2/20-21

!

'

Buscetto

25 1/2 on 2/27-28, approval for 2/26-27

i

Shepard

26 1/2 on 2/27/28, approval for 2/26-27

Tardif

25 on 4/12-13 and 26 on 4/11-12, approval for

.

4/13-14

i

l

Saulter

IMF overtime approved 2 and 9 on 5/2-3, however,

worked 9 and 4 on 5/3-4

Bagos

31 1/2 on 5/7-13

,

F

,

b

-

. _ _ .

.

.

..

.

4

.

.

.

.

._

\\E

R

4

'

R

R

E

4

'

'

8

%

9

N

-

N

K

l&

d

%

<a

h

.

o

s w )

m

n

m

~

s

\\E E WlR %%?T % 4 4 t "e U 4

4 R T t "$ 4 4 *0!M RT 4 T

R "st N1

1 % 2

1 4

,=

1

1

n

't

4 4

ET m > N > N V > N 4 4V

1 N

4 N T m % N T

M s % % h

$ 4 \\q N @ '** w Ts % > N N

% W Y s h .N N

M TV % %

% % N wm W > T * *W4 1

N N T * * T 'T

k VTT T

l9N wW T N m x T N w W V > m W

% d % > M M M

% % % %W

B1 4

e4 4 N >v n M MwdNT

w 9 e

W W >

% % %% %

$R MW :: 1

M M R R R 3

E

R

%

-t T e "JPs = 2 T

_

5

8

E

e

n

9

5

9

-

,

ti

C4 6

.

.

!

ND k$ 1 V "5 W 4 4 WTN

b M 4 W i: ts "d1

"# n Gt;

'

Rv N

h

w

NE

h

ew qwAe

T ::t

.

y

ma.ws

m e o

b

%'

,s

1

, 1'

9

n

se

c

~x <

%

-,

w

s

.

.

R Q 4 .s

'

,N

s

e

-

s

.s

m

s

.

tBW R 2 5 t S = 4 2 4 t;$ t e- *

R R "5 % 'Q 2W

t# tM U ( 3

e

d

? R R 4

4 R 4 2 6

N

? ? T 5 5 ? R

T RT T d k

"$ t d

4 4 R a w E3 9 e

a RT d ,'n e R

.0 ::- .M :8 M d.

f"9% >2 e- ::: 2 6

We O S

d

2

R R R T

M

W N T E 4 4 R R R

'E :- Q 49 8

x

kSi

T d 4

W 6 1 %

4 7 E ?W3 1dt W R ? T dTT U

4M e-

-

x

.

$

4

e

e

,5

&

.

.

.

.

.i

5

a

a

a

i

e

i

.;

i

s

a

$'

"

4

a

a

a

e

=.

.

.

.

.

.

e.

g$y,1

~

a

=

e

a

.:

~

a

S

a

a

g

-

a

g

a

.

.

.

.

.

.

.

kk!! ! I I $ l $ $ i k l'l $ 3 i $ $ I I l I

l

x

a

s

s

g'e y ,j~~

Page 9

.,

,,

.

T2GURE 7.2

' AUTHORIZATION TO EXCT.ED ESTABLISED OVERTIE LIMITS

'

-

.

.

--

_

_

Unit (Departrent) 7bSM-2 IMMM

'

l

.

- - -

PERSONNEL

MA)

M

,M

971

JD&uXMb

L j7CJt' M 4 )5

-

(f

s

..

l

t /4// f

Approved from s/S/8f

to

//

(date)

/ / (date)

The above listed personnel are authorized to (check applicable conditions):

Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> stra'ight (excluding shift relief / turnover time).

l

D

,

D Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (excluding shift relief / turnover

l

time).

Work without a break of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> between work periods (including shif t relief /

O

turnover time).

APPROVED

'

i

First Level Supervisor

(Date)

Work more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a 48-hour perio (excluding shift relief / turnover

-

'

APPROVED

o

j

,h

.-R -/- 8'9

-

rs}-Level Sup~ervisor

(Date)

APPROVED

Nu

/U, m

?/k/F/

fecond-Level Spervisor

/(Date)

D Vork more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in a 7-day period (excluding shift relief / turnover

time).

APPROVED

'

First-Level Supervisor

(Date)

APPROVED

Second-Level Supervisor

(Date)

APPROVED

>

-

Director / Station Superintendent

(Date)

_

REASON

Gibu f A W

s }& <~ ~ w <<..us s / I? e u h e eu.1 case ~My

8

'

.

-

A COPY OF THIS FORM MLST BE SENT TO TE STATION SUPERINTENDENT AND DIRECTOR,

1

AS APPLICABLE

NED 1.09

Rev.

1

Date': 10/10/86

.

Page 7.2-1 of 1

'

- - - -

,

. _ . .

. _ _ _

-

-

,

TIGURE 7.2

, ' ,

AITTHORIZATION TO EXCEED ESTABUSHED OVERTIME LIMITS

,,

'

.

-

- (Departrent) YhY d$}')O2YmmY

'unst

.-

PERSONhT.L

a/A A

VI

Ada fc2db

x.s.-e

/ A L z & n 0 s) '

whsJGs)

/dt A~A (un) 2

71/M4Aas)

?

J

Ym

fc2 d

NUYA l'

/

A pro

from 4h /P 9

A l7f??

to

P

//

(date)

/ /

(date)

.

The above listed personnel are authorized to (check applicable conditions):

Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight (excluding shift relief / turnover time).

l

~

C

Cl Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (excluding shift relief / turnover

l

time).

Work without a break of B hours between work periods (including shift relief /

0

turnover time).

APPROVED

First-Level Supervisor

(Date)

'

[ Vork more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a 48-hour perio (excluding shift relief / turnover

d -P -['f

APPRO\\

m

4_,n.

,

d. /

APPROVED

o-

46'cond-Level Sugrvisor

(Date)

'

Vork more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in a 7-day period (excluding shif t relief / turnover

D

,

-

time).

l

APPRo\\T.D

First-Level Supervisor

(Date)

APPROVED

Second-Level Supervisor

(Date)

APPRo\\T.D

Director / Station Superintendent

(Date)

,

t

l

!

REASON

G-:hul

Pcnh

reacive

cLuur>.sdol,, / s/d

istm wrw s

N

.

1

.

!

A COPY OF THIS FORM MUST BE SENT TO THE STATION SUPERIhTENDENT AND DIRECTOR,

'

1

1

AS APPLICABLE

NED 1.09

Rev.

1

(

Date: 10/10/86

.

Page 7.2-1 of 1

,

,

I

i

,

i

new, c

..

,

FIGURI 7.2

,

.

AUD10RIZATION TO EXCIID ESTABIJSHED OVERTRME LIMITS

-

' Unit (Departrent) 7M cf 'P2/uM

--

PERSONhT.L

,.

.

.Y

u.-l>-

(AS$

ud

(dS

A

-d J L a <>v2

t% A~adawo

v

'

M M (a d

L d%2(as%)

S'S

Y lAL (dV

.

a/fr

4, P [# 9

to

Approved from

//

(date)

// (date)

The above listed personnel are authorized to (check applicable conditions):

l

Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight (excluding shift relief / turnover time).

O

Vork more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (excluding shift relief / turnover

l

D

time).

Work without a break of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> between work periods (including shif t relief /

O

turnover time).

APPROVED

First-Level Supervisor

(Date)

shift relief / turnover

'

[ Vork more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a 48-hour period (excludin

.

W,6&

APPROVED Y $ h >3 0

~

'2-flo/W)

  1. /(Dpte

Tirs4.-Lev 1 S ervisor

APPROVED %4'

/

(Date)

goIFd-Level 96pervisor

Vork more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in ahday period (excluding shift relief / turnover

D

time).

APPROVED

First-Level Supervisor

(Date)

APPROVED

(Date)

'

Second-Level Supervisor

l

-

APPK0VED _

__

l

Director / Station Superintendent

(Date)

'

1

(

REASON

I

__

'

_

A COPY OF THIS FORM MUST BL SENT TO THE STATION SUPERINTENDENT AND D

AS APPLICABLE

Rev.

1

NEO 1.09

10/10/86

Date:

.

Page 7.2-1 of 1

-

'

t

_

_

. _ . .

. ,.

_

_

.

.-

'

. . .

, . .

TIGURL 7.2

I

ALM 10{22ATION TO EXCEID ESTABLISED OVERTIME LIMITS

.

,

(Departrect) 7 2 E k d

paMM

i

~

Unit

__

$'ERSONNEL

,

  • $)1s

fAu

>-

J8~ A W d )

>/A ru A

a J

L Aw

"'

+buh

444J h "

eda LA

.

Approved frca

7/ 4 / f'

to

7 / a l' f

[

I

'

.

/ /

(date)

/ /

(dt.te )

The above listed personnel are authorized to (check applicable conditions):

Vork more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight (ex' eluding shift relief / turnover time).

l

O

Vork more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (excluding shift relief / turnover

l

,

0

time).

Verk without a break of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> between work periods (including shift relief /

O

,

turnover time).

'

APPROVED

'

First-Level Supervisor

(Date)

l

O Work more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a 48-hour period (excludin's shift relief / turnover /\\

,.

Q2

time).

APPROVED Tilst-Level Supervisor

(Date)

APTROVED

l

Second-Level Supervisor

(Date)

,

/ Vork more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in a 7- a p iod (excluding shift relief / turnover

time).

/

l

APPROVED F h.

dW

?////h

irst-L

/ f(Date)

APPROVED ((1 6 [ beg Supervisor

e /// M _

'

,

l

7/1,/6

APPROVED

r

c-

i

lAire c t o rf5Ea tionS up e rin t e n d en t

(Date)

REASON

l

'krat/2,r Pr.s cest% lrl-, - c e i k e d p a f l1

_

i

l

(E)

Di e 1 < /

c, e n e n /v <

w <-v k , f k e Lie cJ in, med -

,

,

c

l

-

A COPY OF THIS FORM MUST BE SENT TO THE STATION SUPERINTENDENT AND DIRECTOR,

1

AS APPLICABLE

NEO 1.09

Rev.

1

Date: 10/10/86

-

Page 7.2-1 of 1

.

w

y. , -

m.-

-

w

. ._

. . .

.-

_ __

.

D

\\.

'

'

e

E

.

(

-)

.

l

.

l

.

%4

'

^'

i

mg

2

e

9 a

.-

g

.

H

-g*g

w

% -

.

_y

-

,

e

P

,c

'

1:. y

.

,

.

+

,

k

!

,

.

Vj.[ [.$

,

s

t t + y y f f y

7 y

7

,r

p

y

ge-

p

j

7

'

-

,

. g l,. g.g

g

m e t t- + + -j- t t -l-

7

a-

+

r

r

p 7 7 7

,

,

g

+

.e

.p #

3

,..

.. + 7

.+

..

.

_-

,

. c, .

,

,

.

y

..

,

,

.

.

.

6

-

,-s

+

..

-

...

-.

..

3+

g

..

. - . .

.

-m

.

,.

,

q.

g

.

..

__

.

. . _ _

_

. . . -

_

._

_

,

e

g

-

s

s.

-

g

,-

y

g

,

, .-

,

E

,

-l:81 Q

N,

-

-

-

%

-

.

(_

pg-

-

.n

%Q .

.

p .

.

m-

.~

p -%

-

-

-O

I

gg-g

g

Q q Q

p

9

vd 'N

_

r

m

-

.

m

e m

c e

c

e

m

,

,

N

N

%

N

%

s

g

%

N

N

%

%

T

)

N

t$ N

  • %

T N

M

N

@ %

4

N '::t-

9 %

%

l

g

l9 %

>

d m

x x

x

w

l

8E 4

x

w w

w w

w

w

k fhiR

R

R

'$

T R R

g

3

_

..

.

_

,

._

_.

.

..

.

-,-

-

esg

.

_

_

.

..

+

7 .7

.,

,

_

.

. . .

_

.

-

. . -

_.

.

.

,

s.

..-;

.

%,

g

. . .

,

. 2

-j

a

---

.

s

4

-

.

"' g

_.

.

.

,

,

'

g

q,_.

_

.

s

.

y

4

.,

__

.,

y

y

~

+4 .f

,

,

'

!

x

e

. - ,

e.

g

..

'.

4

.

.i

.)

,

,

V

.

.

g

..,

f

_.4

. . , .

..

s

,

,

,

_

_ . .

. . _

,

_

_

-

,

,

H E

y

a

5

S

S

d h' f

'

d d

4

i

.

M' d

i

.

.

.

.

.

d

d j i

5

4

E

,-

g

'

2

8 * '

s

.

.

J

g

.

.

-

.

.

.

i

E 3 3 g i i u! a

  • *

t

S

e 8' l" -]a

7

a g

g'

J

g

5

.5

g

f,

,

,

- e

o

- o

.

a n 8 5

sl' ! g. j g. ,

8 j

g

i s

a e f

.

a 8 8 e a s

a

u

8

c

e,a

e

e t a s

c

.

v

o

' ' -

, . . . ,

9

Il .'

ACF.1.lo

Face.o,

5

-

>

>..,.-

,

ev. -

- pT;;c

,-

-g

r

..

.

.

..

&yJt

,

.: FIGURE 7.2 ,

.

'

4

>

r

-

,.

W59'

fJV

AUTHORIZATION TO EXCEED ESTABLISHED OVERTIME LItiITS

-

,

.-

, - J.,a c-

'

, .

>

,.

..

,

'b

'S

Unit (Departrent) $/}f h

' W hjg

16

c,

J.

>

N: '

"

.

w, .n

.

i

'3

<

, PERSONNEL

,c

l

4i

>

,

,

2SN

f

a.

f,fyjp$ a

'

m r g g/ellf =

'T

N

N

.ie

D s/

'

'

..,I

, g,

f

'

m-

rwwnu

,

,,

2.S

, ? I';( ,a;

,

_

_

l

.l'

'

.

,

x

~ 3i&%5%.1

fhh

.- ,,.yQL ',,)

'

'

Approved iros S h /[f

h k-s

to-

M

'

-

+;f.

(date)

-(date):

p.

n;weMNW ] [ %

!

.

g

.

The above listed personnel ate authorized to (check applicable conditions):'i . , ' , _ [

'

+

r

-

-f.

,D

Work ore than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight (excluding shift relief / turnover time);. W

,.

[

Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (excluding shift relief / turnover

l

[

time).

1

,

,,

O Work without a break of B hours 'between work periods (including s.hift relief / .

,

turnover time).

'

,

APPROVED

-i

i

'

'

(

first-Level Supervisor

(Date)

'

} l

,

,

drk more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a 48-hour period (excluding shift relief /turnbEr

-

APPROVED

M

M/d

'

.

. , .x -

.-

.

1

erv'sor-

-

=

t

" " * * - - -

APPRO

/c

'

Sfcond-LevelSupervisor

' (Dtte)

D Work more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in a 7-day period (excluding shift relief / turnover L

i

.

time).

APPROVED

l

(Date);jg&

First-Level Supervisor,

'

,

APPROVED

'

,

&

.,

(Date) Z T

Second-Level Supervisor

-

'g

_ - eWw M O' M,pp

_

APPROVED

-

-

-

- -

-

-

--

- -

Director /Sta tion ' Superintendent m y (Date {fghy*jg y

'

Ma

, 3: ' ' n c .

'

,

.

- Y

REASON

'

,

, . .

..

. ..

o

.

b27A::VJ W/A.iC

0/2/V/e:'?/- ffYh

hk/7d~ N k,~,Y ;, * Y

-

'

s v,:y

f f M 3:ff M ,cf/tf.

6 f f )y?

<r

r

,

i

. %

./

<

,

, , NM ;y&; ^

.

+

,. *qq,

he

+.]

-

,

tU

t "

_ *

-

%'

,

'

r ,

A COPY OF THIS FORM HUST EE SENT TO THE STATION SUPERINTENDENT AND DIRECTOR,5 y%%:

-

'

-

w,

1

~

~ ~ '

AS APPLICABLE

,

NEO 1.09

/

Rev. 1

,

Date: 10/10/86

p

.Page 7.2-1 of 1

i

l

, . -

ACF.1.::=

Pace 9 '

  1. I

..

-

Rev.-2

4

-

.

,

,

~

i

TIGURE ' 7.i

.

a

G,.

_

' AUniORIZATION TO EXCZED ISTABLISED OVERTIME LIMITS-

.

.

,

"

-

,

,

,

i.

.-

.,

,

-

-

-

.

.

..

.lg.. Unit'(Departrent) j/

f- b M/.f;dwaoD

'

,

'i.

PERSONhT.L

!

);.f m

zd

- Aid %s

"

.

I-

p.Apfjg,] .a

y

];),fg

jej%

l

c

IM WML#"E

-

- *

'

-

-

.

7'Q

'

.m_-

a m .;m , ,

,

,g

w

,.

",

,

"

s;

Approved fros'

to

L*'

'

'

(date)

(date)

, .

,

,

The above list'ed personnel ~are authorized to (check applicable conditions):

!

O Vork more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight (excludinF shift relief / turnover time).

l

,,

D Vork more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (excluding shift relief / turnover

l

time).

O Vork without a break of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> between work periods (including s.hif t relief /

i:

turnover time).

APPROVED

7

(

First.-Level Supervisor

(Date)

.,

1%.

/ Vork more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a 48-baur period (excluding shift relief / turnover

'-

APPROVED j f f k &

f//.?///

m ..

. , , .

, .

'

on

APPROVED

segond-Level Supefvisor

(Date)

.

O Vork more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in a 7-day period (excluding . shift relief / turnover

time).

APPROVED

First-Level Supervisor _

(Date).

'

(APPE0VED

'

<

?3

Second-Level Supervisor.

(Date)

-

[

J'

.

APPROVED

' <

.

'

l' t

. Director / Station Superintencent .

(Date)

.

,

=q

..

a"

s

& spsg & &i 'pE?7ahf h>9;/k /ffArdf3/C

^'

eM

Ab'N.sumWy:

er7pm pbcc:

A so drewexr'

. , _

.r

< .

+' .

' '

'

~

"

peop/r

sf M6dMT,

-

^

,

!

..

A COPY OF TEIS FORM HUST E SENT TO TE STATION SUFF.RINTF.NDENT AND DIRECTOR,

"

AS APPLICABLE

~

E0 1.09

/

Rev. 1

I

.

Date: 10/10/86

j

'

Page 7.,2-1 of I

l

'

-

t

.

I

!

I.

.I

.

rr

. . - .

.-

- _ . . - _ - - - . _

_

-

_.

. .

'.

9y y-

n

'

.s.....

, ,

Rev.-2.

r

.

U,

,

.

.T3GUPI?7 d j

cfX

.

...

.

AUTHORIZATION TO D:rrrn ESTABLISED,0VE.RTIME LIMITS

,

y

,

Unit (Departrent)

/

2. E d4 Y$#tcu A

l+:

-

t

.

__ _. ._ _ __

~ ,

..

9

.s

-

j

gg t;

, . , '

'e

'

4

,

"

gg)

ShM

Q

s y': ' 2 C

J'

Q, MLJx

i

A.

ufL

y;fFAxx r 4

-

g.2/n

.

As;

Q&gh . A

"

~

19[ .

1

p. Ana

x

awwm 9,,,

+

.

Approved from

U

f

//

h

'l

m W ' (date) : .

J

, ' w,-

+;) .-

'(da te ) ,

%w

-

,

TheabovelisYedpersonnelareauthorizedjto(checkapplicableconditions):

.

'

n

Vork more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight (excludin shift relief /tt.uover time). H:

l'

.

,

D Vork more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (excluding shift relief / turnover

l

'

time). .

4

Vork without a break of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> between work periods (including s.hift relief /

0

APPROVED

h

M f//7

'

, p ?! '.

first-MelSupervisor

'(Date)

p p

,

Nrk more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a'48-hour perio'dl(excluding' shift relief / turnover

~

  1. /#f[

/

,, APPROVED

p

'

' " -

-

sor-

,

fcond-Level 96pervisor

/U)tte)

l

I

D Vork more than 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />'s in a 7-day period-(excluding shift relief / turnover

j

time).

'm

'

'

!

APPROVED

_ First-Level Supervisor

(Date).t

'

'

APPROVED

O

2

'

. Second-Level Supervisor

(Date)-

!

-

l

APPROVED

^

& T./

.

Director / S ta tion ; Superintendent . (Date).

'

REASON @+

'

.- y%-

. >

//A5 rMPA & 8

A/Mt.J

<Skk;?S ') b2

/Z

,

s

.,

,

fjof3mggf,,;

th. ~ %

'

_

/-

vQ M

y ! > :g. p.

,

,,

y

<

,

/e

,(M.f

,

. .

s.

y a,

--..

, , .

_

s.

. g 7 , r;

V

A COPY OF THIS FORM MUST BE SENT TO THE STATION SUPERlhTE.NDENT AND DIRECTOR,

_

~

l

,

l

AS APPLICABLE

E0 1.09

,/

Rev. 1

/

Date: 10/10/86

.

'

f

-

  • Page 1.2-1 of 1

1

, .

'l

.

.

.

J

'

~

-

(

.

,

-

.

R

1

.

l

g

'

'

-

.

o

.

p

1

.

-

.

,

3

sy,

'

.

I

s

s

,

,

"

y

,

y

y

o

,

y

r

-

g

y

c.

e

.

.

,

! , _ I g.

4

o

di

l Mit 0 4 4 V 1s t w C2Nc

'

4

'

-

'

'

R R N a n

R t

W

M

'

'

..

$&

E y m d m V 4 s v. T V4

L

.

,

3 %

p q w N m y > > w g > y

g n

4 9 % w s > OA

i

'd Q

>

l

gl sT N m VM % % TYY

) l w '

8g n

4

T w>

w >

J (

'

-

p

l,g

e y

y

-

-

a;:}

49

.

,

,, #.

,...

.

l

Nu

A

v

~

g

qq

3

n

+

-

L

g

J 2

1

J

m

.

s .s

m

.

U

._? JN

'

3

'

i

Nn

% N

,

Ie

s 3m

_

_

N t

~

RR

  • -

-

.

'

NN 's b a ts' O c M a *WT .s t Y

A 4

'

>

g g

-

o

ce e 4 4

e4

+

=3 1

a

-

.

,,

Ar

2jds

18 R N R M

R R

V ?

1#

{ Q

2

L)E)R = .R .st 41 4

Ef 4 4 T 2 2 4

x-

-

V

W m

nji

d B

-

>

.

% e o 9j

sp ie @R .e4 g ::! gt

u% .R :e e m

? 7( Q -

"

e

-

.

,

D

49 4 14 : R R 'Q G 4

'$ R Q Q R R R

M A

~

'

'

wp u me e a v a a e v % t t t

kg

'

bi

-

R *

R MN 4 4 % R Q4

-R R 4

'y %

l

.

d

.I

3

.

n

.i

-

[,

'

u.

i

,;

c

n

. g,

,

,

s

m,

a

.

,

.

.

.

.

.

.

l

$

s' .

R

U

%

y

Y

3

.I

c_

D

-

N

.

3

[

' l

.

.

.

Vv, ,s ,

~'

,1

p

-

ty

'O

Y

4

?

s'

i

.I h

[ [ [ ]

f'

j' [

f [f .

.[

.

-

,

'

6o

%n

1

7

.

i.

-

, , ,

.

.

..

~

.

. . . .

. _______-__ _

. ..

'-w-

e

Rov. 2

,

t.

.

'

.. .:'d_

4

.d

W FIGURE 7.2

,

'

AUTHORIZATION To EICEED ESTABLISHED OVERTIE I.IMITS.

<

.

.a

..

.

- %;q p

{

.

jt

,

m.

2

'

unit (Departrent) UM d'77)dM

'

o

1

-

%

PERSONNEL

&

. ._

~MM)enJ1 A.

- s.Pa44Mehe

  1. aAwred

.

f

l

'

'

'h}f

.-

'

'

-

'h

' ik.QMS$MM@W[ ' i

?-

",

.

,

q,

"

,

Pf

Y'

,

' '~

YY Y

'

to- 4

!

'

'

/ - / - :(date)

-

<b.

" -

Ap roved from ~f. : f o.g

-(date) -

]

The above listed personnel are authorised to (check ~ applicable conditions):-

,.

l

g

a

Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> stra'ight (ea'cluding shift relief / turnover time).'$

.j

"

Q

l

Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (excluding shift relief / turnover

Q

time).

'

k of 8'. hours between work periods (inSluding shift relief /

~

'

D Work without a.br

turnover time).

.

.

APPROVED

(Date)

l

Tirst-Level Supenisor

s

s

f

riod (excluding shift relief / turnover

,

2

al Work more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />? n a 48 o

4//lh9

. .

i

'

time). ~ -

,._ .

.

'a ' e

.

' APPROVED-

Arn0VEDMIN

"#*

yd

  • '

(Date)

gfecond-Levelj5upervisor

Work more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in a 7-day period (excluding shift relief / turnover

D

time).

,

APPROVED

(Dateh

[first-LevelSupervisor

-

APPROVED'

(Date)'

>[

"

,'

' L:vi ..qll;;Second Level Supervisor

C

(Date)i ,

{4-Q

4

'

.

d ? APPROVED? f" Director / Station Superintendent-

.

'

g

.-

M e,i'

1:

.

$.

'

,

4

mumanemummma

REASON,

-

YYoC<wL Clu>rwrf

'

h RedaeFA NbeAhv':eww en

@ W6prt % vkn M UGA/n1/IR%k runw$

'

..

e

-. '

t: y jp; f'

.,

_c .

.,

,

RECTOR,

A COPY OF THIS FCRM HUST BE SENT 70 THE STATION SUP

~

'

Rev. 1

AS APPLICABLE

NEO 1.09

10/10/86

Date:

h

f

Page 7.2-1 of I

.

j

.

'

-

s

-

.

.--

- --

.._. - _.--

_ --.

..

.

.

.

'=w-

-

J

,

. . . .

R2v. 2

.

.X,J-gl

.

'

vL

% m/-

M' U

FIGWtEL 7.2 -

4l~4 %fgg@H

Atml0RIZI. TION To EXCEED ESTA8LI*wrn OVERTI)G" LIMITS

-

p* Qy!

,'

-

,.

e-J

.

^'& ,, ' h.

.y

.

h3 .

- [$ . +g8 6. ]

Unit (Departrent)' G / M , 2 DM

M Nf/y.1 P .

$hk N ']?

8

-

,.

-

FERS010tEL

-

'

"l"R$h.~ ~

.h

'

A.~L.??$U & W W

.

.2g Z

j'

&

.

ylW2 @

7

,

.

.

.

,'

A yg; 0's,.w;:;

j

4

.,!j 7 'u:,

}.i'

i

.

.

.

Wi

" ? d?b4

,.

+)<

'

'

4 >

.

'

%$W J':

'

!

hh"

k

.,

k

to

*P@W.?[;,{Qh

M-

x

/-

/ (date)

Approved from

,

'

'

/,./

(date)

l-

..

j[p[.9[/-

)i p ..

!

The above listed personnel are authorized to (check applicable conditiona

i __

.m

Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight (ex'cluding shift relief / turnover ti

f 1%.[

g :. 3

,

.

.

v

.: iF

,.

,

O

-

.

c Work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24-hour period (escluding shift relief / t

t:

i

1

l

-

I-

time).

.

/S ,[l 1$

Work without a break of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> between w

t

.

"JQ

Y

(

'

Q

turnovertime).

i

APPROVED

(Date),

s

i

first-Level Supervisor

- ;, #: - mj

,

'

[riod (escludin8 shift relief / turnover

@&

'

r

a Work more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a 48-b ur

j c) : M Q2

.

.

4!/$t87

4

time).

(g*Iff9**'i**'

',ff"hhil.y$G.

,,

+

aPaoVED

-c_-

(Data)

f

, , , ,

'

ecood-Levelpupervisor

.

,

,gL. .

--

Work more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in a 7-day period (escluding shift reltaf/ turno

<{F

.,

c

l

, ,

,

O

-o

'

time).

_

.;

APPROVED

(Date)j

,

4

,

first-Level Supervisor

C5 , ,

a

L'

-

-

' Second Level Supervisor

W j;j MI

,j

APPROVED

(Date)j.

J

(Date) 4;[!m

'

.

d

APPROVED

g

Director /8tation Superintendent,

'

>

~ , EN 33

h

.

'

) 'M

SS

M^^ m

c*/oit<M %ssa$hfh

= = = = = = = = = -

REASON

,

l

. iw

frenuvi 2-cl-

//

-

3m

an~c

/

.

,

1

,

$

e

-- _

.h"

-

- ,.

,. ..

_

i

.

.

NT AND pinCTOR,

~A COPY Of THIS' FORM !!UST BE SENT To THE SIATION S

?4

/

Rev. 110/10/86

.j

AS APPLICABIE.

NEO 1.09

Date:

'i

l

Page 7.2 1 of 2

f

/

.

.

-

I

s

i

i

. - . .

.

. , . .

. _ _ . . , , _ . _ _ . , _ _ - . _

_ _ _ _ . _ _ _ . _ . . - . _ _ _ - . , .

.. -

.

.

. - . . . .

.

.. s

.

.

. . .

. . . - .

.-.

.

.----_-_-_,________--_____-_-_-_----_-----_;

1

.+

. _ . . .'-

,3--

-

.

g

June 15,1982

'

-

.

,

70 ALL LICDISEES OF OPERATIM PUWT5. APPLICANTS FOR AN

OPERAT!M LICENSE. AND HDLDERS OF CONSTRUCTION PERMIT 5

Gentlemen * '

i

I

.

.NUQ. EAR POWER PLANT STAFF WORKING HOURS

-

I

ci

SUBJECT:

lm.

v

-

,

u MGeneric Letter.No.1: 8212)-

=W'

-

t

4

.

'

-

,e

m .e .

w.gw , y

y

,

.

5

on February 8.S1982.'we forwarded to you a copy of 'a policy statement -

,

I

issued by the Counission' entitled 9olicy @ Factors Caustag Fatigue ;

'

,

E

of Operating personnel,et nuclear Reactors? 1 hat policy statement

.

!

has now been sitehtly revised and.the revised version is attached to:

' this letter.E The forwarding letter (Generic Letter 82 02) stated that

~

j

actions were underway to incorporate the Caission policy on working

l

!

hours into Regulatory Gutde 1.33 and into WREG-0737 (Itam I.A.I.3).

I

Publication of Regulatory Guide 1.33 ts neu anticipated in June 1982

,

following release of ANS 3.2. Revised pages of NUREG-0737 that incor-

'

l

porate the Cosnission policy on working hours are enclosed.

'

'

!

Our letter of February 8.1982 requested that you.take action as-

necessary to revise the shinistrative section of your technical spect.

i

l

,

f1 cat 1ons to assure that your plant administrative procedures. follow-

'

the revised working hour guideltaes. including a provision for docu--

j

sentation of authertaed deviations which shou .d be available for NRC ~

I

review.uYou should revier, pour pet nettons to assure that they are,

'

,

.

.

consistent with the attached revised policy statement. Note that the-

,

'

revised guidelines are to be incorporeted by October 1.1982.-

'

Stacerely.

,

.

i

Darrull G. Eisenhut. Director

'

~ Divtston of Licensing

'

Office of Nuclear Reactor Regulation

-

h

'

Attachments

.

.

-

-

Raviston to Item 1.A.I.3

d

of WREG-0737

M06160341

-l

1

i ih A.l}

0A}

TcWW/UUJY! ]W'

.

'

.. _ _ __ . _ _ _ _

_

_ _ _ _

__

_

-

_ _ __ _ _.

_ _ _ . _ _ _

.

. *

.

.

,

.

.

'

_

l

.

.

'

[

1.A.1.3 SHIFT MAHING

,

.

Pages 1.A.1.3-1 through 1.A.1.3-3 are replaced in their entirety by the following. "

A bar in the margin indicates changes from the material originally included en%

these pages.

f

  • '

,1

-'

J

Position

, N, dI'2 4D.3f&Us),y

,

<

~: .] l }:

l

e

?

This position defines shift manning requirements for normal: operation.j;The11etterN .

.

.

.

'of July 31,1980.from D. G.:Eisenhut to all power reactorilicenseestandLapplicantsW

'

- _ -

.y y :w j ygygg:4.yy

,

(copy attached) sets forth' the interia criteria for' shift: staffing.(to_ beLeffective T '

m

.

..

<

yg

,

.,

l

pending general . criteria that will be' the subject of future .rulemaking).c OvertimeL

'

spt

.

l

restrictions were also included in *he July 31,19ft letter.

1

'

'

I

,

o

Changes to Previous Requirements and Guidance'

i

'

Errors were discovered in the last column of the table attached to the letter of

July 31,1980. A corrected table is enclosed; a bar in the margin indicates the

correction.

(See p.1. A.1.3-4.)

!

The overtime requirements have been rewritten to incorporate'the* provisions?of f" "

^

s

Comission policy statement on working hours and operator fatigue.

~

i

t

I

Clarification

r

l

Licensees of operating plants and applicants for operating licenses shall inclu'de

5' .s

-

!

9;

&

l

in their ahinistrative procedures (required by license conditions) provisions? \\ *

.

...

,

'

,

,

governing required shift staffing and movement of key individuals ' bpt.the! plant /p } m J

a

~

,' y

~ -

...

.

.x

These provisions are required to assure that qualified plant perso'anel to man the;

O

<

.,%

in

operational shif ts are readily available in the event of an abnormal;or., emergency 6 'k' f

e

J

'

.

.

>

,

P

,

51 tua tion.

-

'

f;

-

..

'

'

n . .-

.

.

<

,

~

.

'

..f .-

..

?

?

i.

.

,

-i

- . - - - - . . - - - - - - - - . - - - - -

-

- -

. - . -

. . . - _ . - _ . . _ - . - , - - . . , , . , _ .

. . . . . ,

,, , . , , , . , - . . . . ., , , , . ,

,-,,w

, , , , . , ,

,,

-

.

-

. _ _ -

. ..-

.

.

-

l.

.

  1. ..,

,u

,.

3

b l

'

t=

\\

.:

=

,

.l

.

.

.-- ,

These seministrative procedures shall also set forth a policy, the objective of

which is to prevent' situations where fatigue could reduce the ability of operating

i-

i!

y

personnel to keep the reactor in'a safe condition. 'The controls established

jj

-

-

should assure that, to the extent practicable, personnel are not assigned to.

[

e

at

ik ,

n

,-m,

shift duties while in a fatigued condition:that could significantly reduce.thef r

f>

.

-

f .y.

_

7f-

.

x, g _ , ; .

,

-

ggg( ;q 6 mentaljalertness or' their. decision'aaking ' ability. ? The _ controls: shall apply to'

-

-

,

.

,: :

.

.

..

..

. , -

.

c ;.

-

.

.-

.

% .g "

,

.

3 the p1' ant staff who' perforu safety related functions (e.g., senior reactor

<

,

,

-

operators, reactor operatorsi auxiliary operators, health physicists, and key

y

maintenance personnel).

-

IE Circular No. 80 02, ' Nuclear power plant, Staff Work Hours", dated February 1,

l

1980 (copy attached) discusses the concern of overtime work for members of the

plant staff who perfom safety.related functions. The guidance ~ contained in

"

g

IE Circular No. 80 02 was amended by the July 31. 1980 letter. -In ' turn, the

overtime guidance of the July 31. 1980 letter was-revised in Section I.A.1.3

. . of NURG-0737.; The NRCi has issued a policy statement (attached) which further

.

._

revises the overttee guidance as stated in WUREG-0737. This guidance is as

.

follows:

,

.

Enough plant operating personnel should be employed to maintain adequate shift

coverage without routine heavy use of overttee.: The objective is to have operating

J.

,

jg

personnel work a normal 8-hour day.;40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br />. week while the plant. ip operating.

'

,

However, in the event that. unforeseen problems require substantial amounts of

overtime-to be use'di or during extended periods of shutdown for refueling, major -

>

i

4., ,

maintenance or major plant modifications, on a temporary basis, the following

guidelines shall be followed:-

-

~

.

.

!

l

l

'

.

,

i

i

- , . - -

.

,,,

,

e.--

.,,-.s-.

. . . . - ,

--.,ew,.--.-e--a,-.-~w

a-,,,,

. - . _ , . ,,n-,-

- . . . , - -

-w...--e,,-

>- , , , .

_

-

.

-

.+

.i

. ., : . .

g

,

.

3

"I

1

.

,

'

._

'

-

.

.

.

,

'

.;,?

,

a.

An individual should not be permitted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> st'raight.

fl

'

.

!

(excluding' shift-turnover time).'

..K]

1'

m

>

,

<

h

b.

An individual should not be permitted'to work'more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in any

  • 4:

<a

!

24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> partod, nor more than 24~ hours';in any 48-hour partod,-nor more-

11

1

. .

.. . . .

.

4

\\

. 2% .

. :

!

.

then.72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in any:. seven day periodi(all,;enchidin . W

@1%

...

n.

, ..

. . -

..

, p

M AM2 PlMfpRh% bQF , lg shift' turnoveri,ime .%

t

e

i

A break lof attleastielght*h@ours:

.

M;_'W QMi%n@'1shouldtbet@ allowed bet

',

m

!

c.4

.

.

4

h

T

(i ncludi ng j shi f t ' turnoveg time)@.g@jMW in p~

i et

TM

1

^

'

l

'e 33g #-

N wf.

y

%

s

-

.

- ; _.

. m

, ..

d.'

Except during extendad.shutdow(periods.ithe,' u. sse of overtime ~ should be -

.

.

m

i

,

considered on an individual. bast' and not' for the entire staff on'shif th ,

~

s-

4

,

!

Recogntzing that very unusual circumstances. may arise requiring deviation from

.

.

'

the above guidelines, such deviation shall be authorized by the plant manager

6

l

- ..

.

s.

w

or his deputy, or higher levels %f management. The paramount consideration in

.

suchauthorization.shallbethatsiinificantfreductionsintheeffectiveness'of-

'

,

,

operating personnel would[be hlghlylun1'ikely.? Authorized deviations'.to':the

'

~

!

.

i

working hour guidelines shall be documented and'available for NRC re~viewi

"

m - v os ,,.+ ~

~

.,

I

'

In addition, procedures are encouraged that.would allow Itcensed operators at

the controls to be periodic'allyTrelieve'd and assigned to other duties away from

'

,

.

,

the control board during their tours of. duty.r.

e ,.;m

ywwplpggg

-

'

"

QM ' '

tyt;? e

kip

',

, ~... n . ;

'

yae

a,*,

Operating license applicanttishal1}cosplete these' ? administrative procedure's .

't

,

,. ~

,

'

.W6M&WM

.M

before fuel loading. Developmentrand;ispleme}CE J .

.

ntation of the.edninfstrative?

. , ' .

l

, espy %%M .

m

e

L

procedures at operating plants'will 335ti;prp

berreviewed,bg the Office ~ of Inspection

yi x 2 HMMW *f

and Enforcement beginning Oct.TIQ1982.% L.

/

-

.

. . .

>

s

J

t

9

7

<

4

4 ,,

-

,

,

,

,

. DI6 .g

'

y,.

r

+

,

.

l

ip.y .y

<

+

.

V

1,

,

,.

. ;,

4 7 ' -' -

Js /

,

4

1

4

4

i

!

'

-

l

.

..

k

_

. .

. .

t

'

.

.

.

- . .

- - - - - - - -

- - - - - - - - - - - -

.

.

. ..

.

.

1

.

.

'

'

a (

'._ .

'

~

&!

.

,

1i

.

<

'

!

4'.

.

,

=

1 !

See Section !!!.A.1.2 for sintaus staffing and augment capabilities .for

emergencies.

f

a

.

.

I

Applicability

-

,

This requirement; applies to all Itcensees of operating reactors 1and. applicants

w,s- .

>

.

,

'; ;

'

';

?.

.

,

g;

y

  • g,

,\\

,

.

.

,

,_

_

for operating licenses.

T2

"'

,

,

.

Implementation-

4

'

t

(1) Overtime administrative procedures shall be established for operating

i

.,

reactors by Oct.1,1982 and by fuel loading for applicants for operating

Itcense.

-

(2) Staffing requirements shall be completed by July 1.1982 for operating

j'

reactors and by fuel load for operating license applicants.

),

!

Type of Review

1)

.

o.

.

4

A post-implementation review will be perfoigned on operating reactors.

i

-

Appitcants for operating licenses will be reviewed prior to implementation. ,

j

Documentation Required

i

,

The documentation required is as noted in the letter of July 31,1980.

'

l

-

,

Technical Specifteation Changes Required

i

Changes to Technical Specifications will be required for overtime a*dministrative

procedure and staffing requirements.'

.

h

4

l

l

s

_

f

g

i

.

.

.

.

.. . . . '

2

1

,;

-

-

_.g

>

-.

.

.

-

.

$.

.

.

References

.

.

q

.

NUREG-0660-

,

.

.

IE .Cirevlar, No.;;80 02. " Nuclear. Power. Plant Staff WorkJhours.* February 1.1980.

'

!

. . . . ,

.

.

.

7.

..

>lLettertfrom D.';G;f tisenhutF, x ' s;:v. ,

,

.

..

.

y

. x m w ,:.

-

. NRCi to A

. .

an

.,n_e, _y , g m,e ,ll Pow,er Reactor Licensees. , July-31.1980( ~

. , .

..

.

+.

.

n s v.y

-

,

. . .

.y:n .

y . 13

7.,

. y . . ,- : .q

g ;

.

-

y . . ,, .

.;

.

. , ,. ; 5 ;, -,

,g,

v _

Policy (on Factors; Causing Fatigu,;,e of10per,attag Personnel,at Nuclear Reactorsk

4

-

.

j.

.y,,

. p ;.u

-

,

,

+

'

s , .,

. . x:_

n r.

m,,

.

w .,y;.p

y<

n.

- :

s .

n,

.

-

p.

.r

s. -

y .

.

,

,

. v

,

-

_

7

1

,.d'

1

)

>

eso. -w

('

'

'

e

4

i

1

t

e

-

9

..

s

A:

b

d sN-

'

4

-

z

-

s

)

'

,*$$

,

.s

'

3

.

,

,.

'

$.

'

..

,

<

>

>

,

e

,

.%,

,

?

.h

.*

y

.

4

e

-

ti +

-

e

s

3

.

=

_

/

!

=

n

i

-

r

$

s

-

-

-

l

.

.

N,'.'

,

, yl

{!

'

-

,

9

-

.

-

'

,

,

,_

POLICY ON FACTORS CAU$15 FATIGUE OF CPERATING

-

~

PER$0 0EL AT NUCLEAR REACTOR $4

,

'.

-

_

.

Licensees of operating plants and applicants for operatteg licenses shalli.

establish controls to prevent situations where fatigue could reduce the: ability:

of operating personnel to keep the reactor in a safe condition.- The controls

should focus on shift staffing and the ese of overtime.. key job-related factors)

1

r

that tafluence fatigue. -

+7

gggggg

j>:

a wmew

.

-

The objective of the contrS1s would be to' assure that, fatigued lcondittenttha

m

_ .

..

to'.the:eatent practicableb

'

1

personnel are not assigned to: shift duties whileiin a<

could significantly reduce their aantal alertness ors.their, decision?making

m

,

f

"

capability.' The controls shall apply to the plant staff,who perforOsafety

7

'[

"

related functions (e.g.

physicists, auxiliary op.- senior reactor operators.? reactor operators.'healthu

p;

7

-

erators, and key maintenance personnel)?

' ' W$%

~

,1

a

.

(;

-

Enough plant operating personnel should be employed to malatain ~adequateishifti <

.is

.

coverage without rout'ne heavy use of overtime. The objective is.to haver

"

i

operating personnel work a normal 8. hour day,40. hour week'while the plant is-

'

operating. However in the event that unforeseen problems require substantial

,

amounts of overttaa to be used, or during extended periods of shutdown for.

i

'

refueling. major salatenance or major plant modifications - on a.tamporary' basis.-

-.

the following guidelines shall be followed:-

e

>.

,

An individual should not be permitted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />

a.

straight (eacluding shift turnover time).

+

b.

An individual should not be permitted to work more than 16'hohrs

..

[p

in any 24-hour period, nor more than to hours in any 48. hour:

."

period. nor more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> la anF seven day period;(all "*N ""V

-

excluding shift turnover time).

.

f

..

.".

.

,

A break of at least eight hours should be allowed between work-

c.

periods (including shift turnover time).

.

,;

d.

Except during eatended shutdown periods, the use of overtfae

~

should be considered on an individual basis and not for the

entire staff on a shift.

.

. W"

'

Recognizing that very unusual circumstances may arise requiring deviation;from -

'

.

the above guidelines, such deviation shall be authorized by the plant manager:

i -

or his deputy, or higher levels of management. The paramount consideration:

in such authorization shall be that significant. reductions in the' effectiveness

of operating personnel would be highly unlikely.

l,

-

-

l

In addition procedures are encouraged that would allow licensed operators at. the

j

.

,

controls to be periodically relieved and assigned to other duties away from.the.

'

>

,

control board during their tour of duty.

,

,

,

4y

.

.

y

!

!!

f

,

.. 4

.~., c.;,_ 3 ;_;

_s y __ .3

.;

w

.

.

,,_

_,3,.

_

_.

,,

.

r

.,w

_ _ _ _ _

_

.

.

,

_

. :.

-.

'

.

,

'

.;,.

.

,

.

tb'

,_

_

-)~

,,

.

-

..

~

,

,

JAN 2 81980

,

,

!

MEMORANDUM FOR:

B. H. Grier, Director,. Region 1

J. P. O'Reilly, Director,, Region II

- J. G. Keppler, Director.. Region !!!

ii

.

K. V. Seyfrit. Director, Region IV

'

a

,

R. H. Engelken, Director, Region ~ V

.

t

1

j'

FROM: .

Norman C<Moseley, Director, Olvision of Reactor Operations.

Inspection,.IE.

SUBJECT:

-

IE CIRCULAR NO. 80-d*, NUCLEAR POWER PLANT STAFF WORK HOURS

'

,

The subiect Circular is transmitted 'for issuance on February 1,1980.

The

l

Circular should be issued to all holders of Reactor. Operating Licenses, including

research and test reactors, and Construction Permits.

.

- A draf t copy of the transmittal letter is also enclosed..

.I

. ran C. Mose ey, Director

uivision of Reactor Operations-

L

Inspection

Office'of Inspection and Enforcement-

.

Enclosures:

'

'

l.

Oraft Transmittal Letter

-

2.

Circular No. 80-4 3

.

-

'

CONTACT:

J. C. Stone, IE

49 28019

l

,

'

s

-

h~lA.)d[l3U/ V / )

)D ' Q A 9 I h ^-)

'

If'

-

.

.

_

..

.

.

-.

.-

U

. - .

,

.

. ab

.

-

,

s

~., : .

.

5

WV ', , :.

k

- s-

.w

.:

.

. . ,

-

+,

.y

%, ,, _ fa g

.

9

]

.

,

,

4

.-

'

,.

7

,

,

,

<

-

.

_

,:

.;

.

.,

.

.

n

(Transalttal' letter for Circular 80-k to each holder of an NRC Operating-

.I

License and Construction, Permit)

j.,

. ,

IE Circular No. 80 8 A

14

r.:.

-

,

4

.

.

.

1

'

4

Addressee:.

tc

.

l.'

<

-

+

!.

,

-

x.

3

.

.

,3,.

-

.

.

The enclosed Circ 01M80-Af ts7 forwarded:to' you; forfinformatioi.M 1f.lthere'are-

.

.

any questions'.91. ..

-i;!) ' Qts . . ~

Q .s I,. f t

7

,

,.

.

,

. . ,

related'to:yourqunderstanding 'of '.the ~, suggested actions;;piease .

.

. !i

e

+m

. .

' gh . W q.:.y, o. q e- wiu . ,

- .c

. .

, +.

,

l2n.~.Tp- *

w

,

contact this-office. M :g i j *g)sg'

7. ( y ,y

yp

l

'

-

t.

' f eg

. .m: , ;t 'y

pJ'

.

l3. g .

x

,

,;.

3

qtOf

+

. . ;e. 3:s%s . .w : .-, w.. / u W - s T>

'

"

-

-

net

"w;;;

v.

-

.

-

,

,

,1

a<

v.s.

,

. ... -

. .-

-

O 0. .,

V; _'

.

l*

-j-

M . * ) l)'g ? *u} ' _y}t - .l f f q , .. t : 'V . ' -. . . . . , . , '

s

e'n a m.. ,, , g , e e , ,; 'hl i ' }r. < - ! ' y "~ t: .. ,

  • '

" . , , , , + . . . ~ .i Signature ' _(Regional Director) l Enclosures: , , 1. IE Circular No." 80-e> ' 2. List of IE Circulars -- i4 Recently Issued i' , e ' t ' g g3ty _ ,_y 99I--lN '4 iff .3 4 '/ *.'s p-(lh 4 4.'h 5 - ', ( i p ,y'- 4& +4' f - -.

  • * '

, . ,, % 4 t , s . O }' _ # s s r $gio . . 4e f ) II . , . - ,. U

4' ,y ,j' g , r. I, 7 ,.r ; - + . i- 4 " 3 l , < > < , . , % 4 ' l' }; ,

. ') ' . .{ [ # 'f 'b

e - .j g 4 l: --i. - ;f. . + - ,, " !') }'+*

. - . , , <

y e!> ~' y ,; ~ b k 9 0 e e I / o V t 4 I f .

r , . . n. , . nr . ... . -;~ ;; ;. . , ; .- _ g. . _- 3 . .. , .ggg . .; . g; _ ;. ; ; . ._ , _ }/ e.-

_ __- - . .. .. .. .. . . . . . . .. . . ... . . .. , , .( .. .

  • a

- , , > ' r, ) b ? [ V f, . S$!NS No.:f 6830? " .j . ? ~ Accession:No':1 .a 1: ., ' ' UNITED STATES- . 7912190657 f 1 NUCLEAR. REGULATORY COMMISSION' y' , 0FFICE OF INSPECTION AND ENFORCEMENT , < ai 1rASHINGTON, D.C. 20555- ' ' ' .ce j; , . . , February 1. 1980 - ' -l , , ' IE Circular No. 80 6 J ~ . , . , 4 [ NUCLEAR POWER PLANT ST/.FF WORK H0URS k: ' y 4,

t . - . - .. 7 p ,; , . .

tDescription'of Circumstances:~ Pd , " N

' ' ' . ~ , _ ,9 c' @ q Studies indicate that with..fatigueFespecially because of loss of sleep, anU,, ;> ;p

- - individual's detection of visual signals deteriorates markedly, the. time ith j! ' - takes for a person to make' a decision increases and acre errors are made, and ' <' reading rates decrease. Other studies show that fatigue results in personnel . .{ -ignoring sbee signals because they develop their own subjective. standards'est ' ,- to what is important, and as they become more fatigued they ignore more signals.m ? Inspections of personnel performance and training since the accident at' Three Mile Island, have shown that in certain situations facility personnel-are' , either required or allowed to remain on duty for extended periods-of time. ' Also, complaints have been received free some' licensed nuclear power plant operators concerning the number of continuous hours they have been on duty. Licensee management is responsible for providing a sufficient number of trained personnel who are in the proper physical condition to operate and - , maintain the plant. Licensee management should review their. administrative procedures covering the working hours of nuclear power plant staff. These ' ^ ~ procedures should estabitsh a-sound policy covering working hours for plant., v,4

s staff who perfore safety' related functions (e.g. , senior reactor operators,- - reactor operators, health physicists - auxiliary operators, !&C technicians, . key maintenance personnel, etc.) , ' ! Subcommittee ANS-3 is currently developing criteria to address the subject of - 1 operator work hours. These guidelines will become a part of ANSI N18.7. The -- ! NRC is also considering issuing requirements for administrative procedures that would control staff overtime.: Until either the ANSl~ Standard is issued and endorsed by NRC (via a Regulatory Guide) or separate requirements are:- issued by NRC, it is recommended that the following guidance be used. The guidance should be applied to all personne1~ performing a safety related

, function:

- q ,_ 1. Scheduled work should be limited to the following maximum work hours: . . a. An individual should not be' permitted to work more than 12 hours straight. ' {{ - ' . , , ! W e { / // d . . . .. . t . . . . . V

_ _ ._ _ _ _ . _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ . _ . ___ __ __ . _ . _ _ _ _ _ . _ _ _ __ .- . g ., . 9 . . - .: ,. .!E Circular No. 80-d2 February 1, 1980 ~ . _ Page 2 of,2 > > . , I , , - b. There should be' at least a 12-hour break 'between all work periods. 1 c. An individual ~should not work more than 72-hours in.any-7-day period. i i > d. An ladividual!should not' work more than 14 consecutive days without having 2 consecutive. days- off.-y W . _

tz

l 9 . ,, X. - .

y '. . ' ' , , .

' ~ 'rn -n . ~: i ' . . .. , . ! S; . ' ~ 2. In the" event that'.special circuss'tances'ariseithat require! eviation from' ! d the above, such deviations)should be authorized by,theeStation1 Manager } ' 1 .xv with appropriate documentation of the cause. -71 ants should'be~ staf fed: ! 's > 'and schedules developed to operate such that exceptions'are not required. ' !. 3. If an operator is required to work in excess of 12 continuous hours, his dutie'il should be carefully selected. It is preferable that he not be assigred any task that affects core reactivity or could pssibly endanger , the safe operation of the plant. No written response to this Circular is required. If you desire additional information'regarding this satter, contact the Director of the appropriate NRC i , Regional Office. , l l ' l , ' z % .s I "* . , I % e , ! l.- . i ' , W / I

l a . I . i -

-- __. .. . _ . . . _ . . , . - . . . , . . , _. . _ , , .. . . _ , . . . . . . . , , - - - . . }}