Forwards Application for Amend to License DPR-66,modifying Heatup & Cooldown Curves to Reflect Methodology Provided in Reg Guide 1.99,Rev 2.Westinghouse Rept, ...Reactor Vessel Heatup & Cooldown Limit Curves for Normal Operation Encl
ML20034B932
Person / Time
Site: Beaver Valley
Issue date: 04/19/1990
From: Sieber J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20034B933 List:
References
RTR-REGGD-01.099, RTR-REGGD-1.099 NUDOCS 9005010183
Download: ML20034B932 (1)


Text

.

~

t

  • s' i

4 Be vst V:1tsy Powtr Str. tion Shippmgport, PA 15077 0004 l

\\

6c[ Pre )n Nuchar Group April 19, 1990 H

U. S.. Nuclear Regulatory Commission L

Attn:

Document Control Desk 4

l Washington, DC 20555

Reference:

Beaver Valley Power Station, Unit No. 1 Docket'No. 50-334, License No. DPR-66 f

Proposed Operating' License Change Request No, 177

[

Gentlemen:

Enclosed are:

l.

Application for Amendment' to the above operating license to modify the heatup and cooldown curves: to reflect the methodology l

provided in Regulatory Guide 1.99 Revision 2.-

The NRC'has l

previously approved the proposed pressure / temperature limits of the reactor coolant system by letter dated November-24,'1989.

..e This change has been reviewed. by. the OSC= and ORC and was determined -to be safe and does not involve an unreviewed safety.

question.

2.

Documents designated Attachments A,

B, C and D which set forth the change in Technical Specifications, the-safety analysis and no significant hazard evaluation, applicable-UFSAR changes,,and a Westinghouse report entitled " Beaver Valley Unit.11 Reactor Vessel Heatup and Cooldown Limit Curves for Normal' Operation."

Very truly yours, D

eber-hVicePresident Nuclear Group cc:

Mr. J. Beall, Sr. Resident. Inspector.

Mr. T. T. Martin, NRC Region I Administrator l

Mr. P. Tam, Sr. Project Manager l

Mr.-T. M. Gerusky, Director BRP/ DER Mr. R. Janati, BRP/ DER 1 '.

Mr. R. Saunders (VEPCO) 1 900DG10183 900419 A/

PDR ADOCK 05000334 M[2V /

P PDC f/

4 l l (,

.-