ATTACHMENT 1 Consumers Power Company.

Big Rock Point Plant Docket 50-155 i

i BIG ROCK POINT IGSCC INSPECTION PROGRAM REVISION 2 April'25, 1990 l

l-i i

i 8 Pages OC040'. 0002-NLO4 9005010152 900425 PDR ADOCK 05000155 Q

PDC

[^

L 4

t 1

BIG ROCK POINT ICSCC INSPECTION PROGRAM I.

Scope and Schedule A.

1992 Refueling Outage (end of second ICI interval)

1) Twelve welds previously unexamined for IGSCC are listed as only.

accessible during the. reactor vessel mechanized inspection.

Although these welds will-be examined using standard UT methods, to our knowledge no ICSCC inspection techniques and associated qualified procedures / examiners are available to permit-inspection at this time.

Should the techniques and services become available Consumers Power Company wi11' consider inclusion of these exams in.

the mechanized inspections..

2) Perform ICSCC examination of the accessible portions of'the two 20" recirculation nozzles.

B.

Third Inspection Interval (1992 - 2002) l

1) Examination of one-half (34) of the normally accessible welds i

during the first period (approx.1992 to 1995).

[

2) Examination of one-half (35) of the normally accessible welds during the second period (approx. 1995 to 1998).

i 3) a.

Standard UT examination of the 12 reactor vessel welds accessible only during reactor vessel mechanized examination.

As described above, should the techniques and services become available, Consucers Power Company v111' consider inclusion of the IGSCC exams during these inspections.

b.

Perform IGSCC examination of the accessible portions of the two 20" recirculation nozzles.

II., Revision of Scope and Schedule A.

If IGSCC is detected during an inspection, the number-of welds to-be examined will escalate per the requirements of ASME Boiler and I

Pressure Vessel Code,Section XI, Subsection IWB-2430, 1977 Edition i

through Summer 1978 Addenda.

B.

If IGSCC indications are detected, indications will be evaluated per ASME Boiler and Pressure Vessel Code,Section XI, Subsection.IWB-3500,.

j 1977 Edition through Summer 1978 Addenda.

IC0390-0137A-NLO4

.j

2'

T5 C.

If an indication is unacceptable, repair will be by-weld overlay-reinforcement, partial weld replacement or full-weld replacement.

All flaw repair (s) will be handled on a' case by case basis. Other repair methods may be used if appropriate materials and processes are available that offer the repaired. veld sufficient resistance to-ICSCC.

D.

Indications may be analyzed per ASME' Boiler and Pressure Vessel-Code,Section XI. Subsection IWB-3600, 1977 Edition through Summer 1978 Addenda.

E.

This program will be amended at the end of the second : Inservice -

Inspection interval to reflect code updates as required by 10 CFR.

III. Qualification of Examinations A.

All IGSCC examinations will incorporateI ualified examiners'and-1 q

procedures in accordance with IE Bulletin 83-02.

IV.

Summary To date Big Rock Point has performed 89 examinations for IGSCC on 71 of the 90 accessible welds (7 of the accessible welds were unable to be examined due to configuration). For detailed information on these examinations and a history of correspondence on ICSCC'at Big Rock Point refer to the Reference Section.

V.

References 1.

Generic Letter 81-04 2.

Responses from Consumers Power Company to Generic Letter 81-04 l

dated f'30/81 and 6/22/83 j

3.

IE'Bulletin 83-02 4.

Consumers Power Company's response to IE Bulletin 85-02 dated-5/4/83 and 5/12/83 5.

NRC Inspection Report 50-2155/83-010 6.

Generic Letter 84-11 l

7.

Consumers Power Company's response to Generic Letter 84-11 dated 5/25/84 and 7/2/85 I

i 8.

NRC Inspection Report 50-155/85-018 i

9.

NRC evaluation of Consumers Power Company's response to Generic-Letter 84-11 dated 10/28/86

- IC0390-0137A-NLO4 l

ljg;g{f'-

s mi.

. - -3'

.:. r: '

s

10. Letter f rom Consumers Power > Company tof NRC:'on additional IGSCC :

inspections for Generic Letter 84-11' dated 10/13/86'

'11.

Letter from1NRCEto Consumers Power Compar.y on Generic' Letter 84 dated.10/28/86?

12.; NRC Inspection Report: 50-155/87-003 13.. NRC Inspection Report _ 50-155/87-021-

'14 7 Letter from Consumers' Power Company to NRC on Generic Letter l84-11?

dated"11/13/871 15~.. NRCLrequest for' additional?information on' Generic Letter 88-011 dated.4 /18/89 16.- Letter from Consumers-Power Company to.NRC'on'Generie: Letter 88-01o dated 6/23/89'

{

1 d

v f

I il 7

l' IC0390-0137A-NLO4

..l

T*

' BIG ROCK POINT IGSCC ' SUSCEPTIBLE WEIJ) LIST.

ki Field Previous 11GSCC{

. Comments /PreviousL Weld ID

. Weld:

Exams Routine ISI Exams

-1.

4-MRS-141-1 Yes lISI 2-6?

f1SI 1-3L 2..

4-MRS-141-2

'No I SI-. 2-4

'ISI-1-3

3. : 4-MRS-141-31 No

'ISI 2-4

'ISI 1-3~

4..

4-MRS-141-4 No ISI-2-4 IISI[1-1

5. ~4-MRS-141-5' No ISI'2-6.

ISI:1-1 6.

4-MRS-141-6 No ISI 2-3;i-2 LISI l-1 7.

4 -MRS-141 -7 No ISI 2-3L 2-4

'ISI l-1 8.

4-MRS-141-8 No ISI 2-4 ISI'l-2 No[IGSCC. exam duefto. configuration

9. MRS-141-9 No ai 10.4-MRS-141-10 No

'ISI 2-4 ISI l-2 11.

4-MRS-141-ll Yes No. IGSCC exam due: to configuration

12. 4-RDC-101-1 Yes ISI 2-5'

-ISI'l-4

13. 4-RDC-101-2 Yes

'ISI 2-5 ISI l-4 14, 4-RDC-101-3 Yes ISI 2-6 ISI 1-1, 1-2,71-3,f1-4 15.

4-RDC-101-30 Yes ISI 2-6 16, 4-RDC-101-31 Yes-

ISI 1-9,_

tio IGSCC exam due to configuration-e-

17.

5-MRS-131-1 Yes ISI 2-5 18.

5-MRS-131-2 No ISI 2-5

~

19.

5-MRS-131-3 No ISI 2-5

]

20.

5-MRS-131-4 Yes ISI 2-5 ISI 1-7.

)
21. 5-MRS-131-5 Yes ISI 2-6

- ]

22.

5-MRS-131-6 No ISI 2-6 1

23. 5-MRS-131-7 No ISI 2-3 ISI 1-7 24.

5-MRS-131-8 No ISI 2-6

i 25.

5-MRS-131-9 Yes ISI 2-6 J

q l

MIO290-0091A-NLO4 Revision 2

\\Y+-

-BIG ROCK POINT IGSCC NUSCEPTIBLE' WELD LIST

.5l v ~,, -

Field Previous ICSCC

. Comments / Previous-Weld ID Weld Exams Routine'ISI Exams 26, 5-MRS-132-1 Yes ISI 2 ----

27. 5-MRS-132-2

~No ISI 2-4 28.

5-MRS-132-3'

-No-ISI 2-3, 2 ISI 1-3

29. 5-MRS-132-4 Ye s -

IST-2-4 151 1-3

~30, 5-MRS-132-6'-

llo :

ISI 2-5 ISI 1-3, 1-6 131. 5-MRS-132-7 No.

'ISI 2-3, 2 ISI;1-3~

32, 5-MRS-132-81 No ISI 2-4

-ISI l,

33. 5-MRS-132-9 No No IGSCC exam due tofconfiguration, NoIGSCCexamduettoconfiguratkon
34. -S-MRS-132-10 No J

35.

5-MRS-132-11 Yes ISI 2-4 ISI 2 Inaccessible l(RR'-A38)c 36.

5-SCS-101-2 37.

5-SCS-101-3.

' Inaccessible-(RR-A38)

IInaccessible (RR-A38)

J 38.

5-SCS-101-4' q

39. 5-SCS-101-5 Inaccessible (RR-A38).

40.

J-SCS-101-6 Inaccessible (RR-A38),

41.

5-SCS-101-7

-Inaccessible-(RR-A38)

42. ~6-SCS-102-22 ISI 2-4 ISI l-3 43, 6-SCS-102-23 ISI 2-4 ISI 1-3 a

-l 44.

6-SCS-102-24 ISI 2-4 ISI 1-3, 2-3

'l 45, 6-SCS-102-25 ISI 2-4 ISI 1-3, 2 '

46, 6-SCS-102-25A ISI 2-4

)i 47, 6-SCS-102-26 ISI 2-3 ISI l-3 48.

795-11F No ISI'l-2, 1-9 Mechanized Nozzle-to-Safe End ISI'l-9 Mechanized 49, 14-MRS-101-1 Yes

50. MRS-101-2 No Inaccessible

- i j

.MIO290-0091A-NLO4 Revision 2c

']

l l

BIG' ROCK' POINT IGSCC SUSCEPTIBLE WELD LIST-6<

Pield Previous IGSCC Comments / Previous Weld ID Weld Exams Routine-ISI Exams 51.

14-MRS-101-3 Yes Inaccessible

$2.

14-MRS-101-4 No Inaccessible 53.

14-MRS-101-5 Yes ISI 2-4 54.

14-MRS-101-6 No ISI 2-4 ISI l-4 55.

795-llE No ISI l-2, 1-9 Mechanized Nozzle-to-Safe End 56.

14-MRS-102-1 Yes ISI 1-9 Mechanized 57.

14-MRS-102-2 No Inaccessible 58.

14-MRS-102-3 No

. Inaccessible 59, 14-MRS-102-4 Yes Inaccessible B

60.

14-MRS-102-5 No Inaccessible 61, 14-MRS-102-6 Yes ISI 1-9,2-3,2-4 ISI l-7 62.

14-MRS-102-7 No ISI l-9,2-4 ISI-1-7 63.

795-llD No ISI l-2, 1-5, 1-9 Mechanized.

1 Nozzle-to-Safe End 64, 14-MRS-103-1 Yes ISI l-9 Mechanized 65, 14-MRS-103-3 No-Inaccessible

.a 66.

14-MRS-103-3 No Inaccessible

,j 67.

14-MRS-103-4 Yes Inaccessible J

68.

14-MRS-103-5 Yes ISI 2-4 69.

14-MRS-103-6 No ISI 2-4 ISI 1-5 70.

795-11C No ISI l-2, 1-5, 1-9 Mechanized Nozzle-to-Safe End 71.

14-MRS-104-1 Yes ISI 1-9 Mechanized

[

72.

14-MRS-104-2 No Inaccessible 73.

14-MRS-104-3 No Inaccessible 74.

14-MRS-104-4 Yes Inaccessible MIO290-0091A-NLO4 Revision 2

7 l BIC ROCK POINT ICSCC' SUSCEPTIBLE WELD LIST 7'

=

i Field Previous ICSCC Comments / Previous Weld'ID Weld-Exams Routine ISI Exams

75. MRS-104-5 Yes 151 2-4 76.

14-MRS-104-6 No ISI 2-5 ISI 1-3, 1-4 1SI11-2, 1-9 Mechanized 77.

795-11B-No Nozzle-to-Safe End ISI l-9 Mechanized 78.

14-MRS-105-1 Yes Inaccessible 79.

14-MRS-105-2 No Inaccessible 80.

14-MRS-105-3 Yes Inaccessible 81.

14-MRS-105-4 No-82.

14-MRS-105-5 Yes ISI 1-9, 2-3 ISI 1-7 83.

14-MRS-105-6 No ISI 2-3 ISI 1-7 84.

795-11A No ISI'l-2, 1-9 Mechanized Nozzle-to-Safe End 85.

14-MRS-106-1 Yes ISI l-9 Mechanized 86.

14-MRS-106-2 No Inaccessible 87.

14-MRS-106-3 Tes Inaccessible 88.

14-MRS-106-4 No Inaccessible-89.

14-MRS-106,5 Yes ISI 1-9, 2-3 90.

14-MRS-106-6 No ISI 1-9 ISI 1-3, 1-4, 1-Bi 2-3 91.

17-MRS-111-1 No ISI 2-5 ISI 1-5 92.

17-MRS-Ill-2 Yes ISI'2-5 93.

17-MRS-111-7 Yes ISI 1-9,2-3,2 IEI 1-4

~

94.

17-MRS-111-7LD-1 No ISI 2-4 ISI 1-4 95.

17-MRS-111-7LD-2 No ISI 2-4 LISI 1 96.

17-MRS-112-1 No ISI 2-5 ISI I-5 97.

17-MRS-112-2 Yes

-ISI 1-9,2-3; ISI 1-8 g

98..

17-MRS-113-1 No-ISI 2-6 ISI 1-7

.l l:

MIO290-0091 A-NLO4 '

Revision'2 h

v iv-

' BIG ROCK POINT ICSCC SUSCEPTIBLE VELD LIST 18

,,g e.

Tleld Previous IGSCC Comments / Previous Weld ID Weld Exams' Routine.ISI Exams 99.

17-MRS-113-2 Yes ISI 2-6

100. 17-MRS-114-1 No ISI 2-6--

ISI~1-3. 1-4 101. 17-MRS-114-2 Yes ISI 1-9 ISI l-8 102. 17-MRS-114-7 Yes ISI l-9.2-3.2-4 ISI 1-1 103, 17-MRS-114-7LD-1 No ISI 2-4 ISI - l-1.

~104. 17-MRS-114-7LD-2.No

-ISI 2-4

'ISI 1-1 105. 796-1A lio Inscessible 106.'20-MRS-121-20 Yes ISI.1 Limited' exam-due to accessibility 107. 20-MRSn121-17/

ISI 1-7 6-SCS-102 No No IGSCC exam due.to configuration 108, 20-MRS-121-17/

s 5-MRS-131 No No ICSCC exam due to configuration 109. 24-MRS-lL'4 1/

5-MRS-131 No ISI 2 -----

110. 796-1B No It: accessible 111. 20-MRS-122-20 Yes ISI 1-9 Limited exam due to accessibility 112, 20-MRS-122-17/

5-MRS-132 No ISI 2-5 ISI 2-3 113. 20-MRS-122-11/

5-MRS-302 No ISI 2-5.

ISI 1-9' 114. 24-MRS-121-1 Yes.

ISI 1-9,2-3,2-4

, ISI 14 -

115. 24-MRS-121-5/

4-MRS-141 No.

ISI 2 ' Limited exam due'to confiRuration 116. 24-MRS-122 Yes' ISI 1-9,2-3,2-4 ISI-1-1 117. 24-MRS-122-5/

4-MRS-141 No ISI 2-5 d

'MIO290-0091A-NLO4'

' Revision.2 l

m lu