q CFE Log # TXX-90149 File # 10010. 903.9', 910.4-10110-nlELECTRIC -

j*** * ***

.!R 89-30 IR 89-304 wm6.m J. c.hm, Jr..

April 12'. 1990 Executive Ykr hesMmt U. S. Nuclear Regulatory Commission' Attn: Document Control Desk-Washington, D. C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NO. 50-445

'l BORG WARNER / INTERNATIONAL PUMP INC.,

. CHECK VALVE SWING ARMS REF:

1) TU Electric letter TXX 90139 from William J. Cahill,'Jr..

'i to the NRC dated April 9, 1990-

2) APTECH Report, " Failure Analysis and Service Suitability of.

Check Valve Swing Arms," December 1989 Gentlemen:

i As a result of recent discussions between TV Electric and the NRC: staff, the following information regarding Borg Warner / International Pump..Inc. (BW/IP),

check valve swing arms is submitted. This letter provides additional.

information on the material specifications and inspections for the new BW/IP swing arms (investment cast type) which have been. installed in CPSES Unit l' The commitments discussed in Reference 1 remain unchanged.

Reference 2 recommended that replacement swing arms should include appropriate'-

I specifications to ensure high quality.

It was recommended that Grade CB7CU1

. i investment cast arms should.be fabricated from 17-4 PH stainless steel per ASTM 747 specification with Supplements S6 (material certification). S14 '

(tension test), S26 (homogenization heat treatment), and S27 (marking / identification). The procurement documents for the replacement. swing arms invoked this ASTM material specification and the recommended supplements-stated above.

Note that Reference 2 incorrectly identified Supplement S11 for material certification.

During the fabrication of investment cast swing arms.

TV Electric OA/0C personnel were'present at the manufacturer's facilities to verify conformance to the procurement documents.

9004230015 900412 4

PDR ADOCK 05000445-P PNU ON SD

. m..s,_,

m si

1. _ m m

Q 4

TXX 90149 April 12, 1990 Page 2 of 2 Records supporting this information are available at the site for your review..

Sincerely, SY Mh*

h; William J. Cahill Jr.

WA h-

- A' By: