Amend 38 to License NPF-42,revising Tech Spec 4.6.2.3.a.2 by Reducing Min Cooling Water Flow Rate to Each Containment Fan Cooler Group from 2200 Gpm to 1850 Gpm During Normal Operations
ML20034A060
Person / Time
Site: Wolf Creek 
Issue date: 04/02/1990
From: Hebdon F
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20034A061 List:
References
NUDOCS 9004190245
Download: ML20034A060 (5)


Text

!

3 ca.

j cf '.

'o, UNITED STATES

  • 8 NUCLEAR REGULATORY COMMISSION n

t r,,

\\...+ };

wasHiNotow, o. c. 20sss I

WOLF CREEK NUCLEAR 0PERATING; CORP _ RAT _ ION 0

WOLF. CREEK CENERATING. STATION DOCKET NO. 50-482 Al.'E NDME NT. TO. F AC I L I TY. 0 PE R ATI NG. L I C E NS E

[

i Amendment No. 38~

License No. NPF-42 l

i 1.

The Nuclear Regulatory Cornission (the Consnission) has found that:

l A.

The application for amendnient to-the Wolf Creek Generating Station 1

(the fccility) Facility Operating License No. NPF-42 filed by the Volf Creek Nuclear Operating Corporation (the Corporation),

dated February 7,1990, con. plies with the star.dards and requirements of the Atomic Energy Act of 1954, as airended (the Act), and the Cearission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will crerate in conformity with the application, as an,enced, the provisions of tbc Act, and the rules and rf.gulations of the Conrissicn; C.

There is reasorable assurance: -(1) that the activit.ies authorized 1

by this aundr..ent can be conducted without t.ndar.gering the benith and safety of the public, and (ii).that such activities will be ccrducted in ecmpliance. with the Cormission's' ngulations; D.

The issuance of this license amendment will nct be inimical to the corron defense and security or to the health and safety of the public; i

and E.

The issuance of this eniendment is in accordance with 10 CFR Part 51 I

l of the Corcission's regulations and all applicable requirements have been satisfied.

i P

e

~.

  • 2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this-license arnendment and Paragraph 2.C.(2) of facility Operating License No. NPF-42 is hereby amended to read as follows:

2.

Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendinent No. 38, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto, are hereby incorporated in the license. The Corporation shall operate the facility in accordance with the Technical Specifications and the Environnental Protection Plan.

3.

The license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY C0ttilSSION rHY..

~

Frederick J. Hebdon, Director Project Directorate IV Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: April 2,1990

ATT A C HMENT_Tp,,L,1,CE),S,E,,A), Eppy,E!g, p,0,., } 8_

4 FACILITY OPERATING LICENSE NO. NPF-42 I

DOCKET l{0.,50-482 Revise Appendix A Technical Specifications by removing the page identified below and inserting the enclosed page. The revised page is identified by amendnent number and contains a marginal line indicating the area of change.

The corresponding overleaf page is also provided to maintain docunent completeness.

REMOVE PAGE INSERT PAGE 3/4 6-15 3/4 6-15 5

k e

4 CONTAINMENT SYSTEMS CONTAINMENT COOLING SYSTEM LIMITING CONDITION FOR OPERATION 3.6.2.3 Two independent groups of containment cooling fans shall be OPERABLE with two fan systems to each group.

APPLICABILITY:

MODES 1, 2, 3, and 4.

ACTION:

a.

With one group of the above required containment cooling fans inoperable and both Conto nment Spray Systems OPERABLE, restore the inoperable group of cooling fan <. ts OPERABLE status within 7 days or be in at least HOT STANDBY witlan i.he next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, b.

With two groups of the above required containment cooling fans inoperable and both Containment Spray Systems OPERABLE, restore at least one group of cooling fans to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

Restore both above required groups of cooling fans to OPERABLE status within 7 days of initial loss or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, With one group of the above required containment cooling fans c.

inoperable and one Containment Spray System inoperable, restore the inoperable Containment Spray System to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next.6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

Restore the inoperable group of containment cooling fans to OPERABLE status within 7 days of ini-tial loss or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.2.3 Each group of containment cooling fans shall be demonstrated OPERABLE:

a.

At least once per 31 days by:

1)

Starting each non-operating fan group from the control room, and verifying that each fan group operates for at least 15 minutes, and 2)

Verifying a cooling water flow rate of greater than or equal to-1850 gpm to each cooler group.

I b.

At least once per 18 moc 'as by verifying.that on a Safety Injection test signal, the fans start in slow speed or, if operating,. shift-to slow speed and the cooling water flow rate increases to at least 4000 gpm to each cooler group.

WOLF CREEK - UNIT 1 3/4 6-15 Amendment No. 38 l

i I

i CONTAINMENT SYSTEMS 3/t.6.3 CONTAINMENT 150LATION VALVES LIMITING CONDITION FOR OPERATION l

3.6.3 The containment:isolstion valves specified in Table 3.6-1 shall be OPERABLE with isolation times

  • as shown in Table 3.6-1.

l APPLICABILITY: MODES 1, 2, 3, and 4.

ACTION:

With one or more of the containment isolation valve (s) specified in Table 3.6-1 inoperable, maintain at least one isolation valve OPERABLE in each affected penetration that is open and:

Restore the inoperable valve (s) to' OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, a.

or b.

Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least t

one deactivated automatic valve secured in the isolation position, or Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least c.

one closed manual valve or blind flange, or Be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD d.

SHUT 00WN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.3.1 The containment isolation valves specified in Table 3.6-1 shall be demonstrated OPERABLE prior to returning the valve to service after maintenance, repair or replacement work is performed on the valve or its associated actuator, control or power circuit by performance of a cycling test, and verification of l

isolation time.

+

I:-

i i-

  • For vehes with excessive leakage, refer to Technical Specification.3.6.1.2.

WOLF CREEK - UNIT 1 3/4 6-16 Amendment No.33

. -... -