Attcch23nt 2 PY-CEI/NRR-ll57 L Page l

of Iy OM18:

PDB-F001 Pages i

Rev.: 0 PLANT DATA BOOK ENTRY SUBMITTAL SHEET TITLE:

Unit 1 Core Operating Limits Report Perry Nuclear Power falant Cycle 2 (Reload 1)

PDB -

F001

/Rev. O EFFECTIVE DATE:

MPL J11 SCOPE OF CHANGE:

N/A

' A & EE Mlilf O 1 i

REFERENCE:

PY-CEI/NRR-1104 L i

PY-CEI/NRR-1157 L PREPARED BY:

P. V. Bordley REVIEVED BY:

i I

PORC MEETING NO.:

Date APPROVED BY:

Director - Perry Plant Date Technical Department 9004130144 900330 i

PDR ADOCK 05000440 1

P PDC

)

Attachrent 2

+

PY-CEI/NRR-11$7 L OM18: PDB-F001 Pagr _A of fy PAGE: 1 Rev.: 0 i

)

UNIT 1 CORE OPERATING LIMITS REPORT l

INDEX i

Specification Pag _e INTRODUCTION AND REFERENCES 2

AVERAGE PLANAR LINEAR HEAT GENERATION RATE 3

(CORRESPONDS TO TS 3.2.1)

Figure 3.2.1-1 Flov Dependent MAPLEGR Factor (MAPFAC )

4 f

Figure 3.2.1-2 Power Dependent MAPLHGR Factor (MAPFAC )

5 p

Figure 3.2.1-3 MAPLHGR Versus Average Planar Exposure, 6

Fuel Type BP85RB219 Figure 3.2.1-4 MAPLHGR Versus Average Planar Exposure, 7

Fuel Type BP85RB176 Figure 3.2.1-5 MAPLHGR Versus Average Planar Exposure, 8

Fuel Type BS301E l

i Figure 3.2.1-6 MAPLHGR Versus Average Planar Exposure, 9

Fuel Type BS301F MINIMUM CRITICAL POVER RATIO (CORRESPONDS TO TS 3.2.2) 10 Figure 3.2.2-1 Flow Dependent MCPR Factor (MCPR )

11 f

l Figure 3.2.2-2 Power Dependent MCPR Factor (MCPR )

12 p

LINEAR HEAT GENERATION RATE (CORRESPONDS TO TS 3.2.3) 13 SCOPE OF REVISION Affected Revision Summary of Changes Date 0

Original Issue 5/15/90 5

i CORE OPERATING PERRY - UNIT 1 LIMITS REPORT

r j

Attoch=snt 2 PY-CEI/NRR-1157 L OM18: PDB-P001 Page 3

of _ ly Page: 2 Rev.: 0 INTRODUCTION AND REFERENCES INTRODUCTION This Core Operating Limits Report for PNPP Unit 1 Cycle 2 is prepared in accordance with the requirements of PNPP Technical Specification 6.9.1.9.

The 9

core operating limits presented here vere developed using NRC-approved methods (Reference 2).

Results from the reload analyses for the General Electric fuel in PNPP Unit 1 Cycle 2 are documented in References 3 and 4.

The cycle-specific core operating limits for the following PNPP Unit 1 Technical Specifications are included in this report 1.

Average Planar Linear Heat Generation Rate (APLHGR) Limits for each fuel / lattice type, including the power and flow dependent MAPPAC curves.

(Technical Specification 3/4.2.1) 2.

Minimum Critical Power Ratio Operating Limit including the power and flow dependent MCPR curves. (Technical Specification 3/4.2.2) 3.

Linear Heat Generation Rate (LHGR) Limit for each fuel / lattice type.

(Technical Specification 3/4.2.3)

SMAPLE l

REFERENCES 1.

USNRC Generic Letter 88-16, " Removal of Cycle-Specific Parameter Limits from Technical Specifications," October 4, 1988.

2.

" General Electric Standard Application for Reactor Puel-GESTAR II,"

NEDE-24011-P-A (latest approved revision) and NEDE-24011-P-A-US (US Supplement - latest approved revision).

3.

" Supplemental Reload Licensing Submittal for the Perry Nuclear Power Plant Unit 1, Reload 1, Cycle 2," GE Document 23A5948 Rev. 1. (November 1988).

4.

" Supplement 1 to the Supplemental Reload Licensing Submittal for the Perry Nuclear Power Plant Unit 1, Reload 1, Cycle 2," GE Document 23A5948AA Rev. O. (October 1988).

CORE OPERATING l

PERRY - UNIT 1 LIMITS REPORT

.m

l OM18: PDB-F001 l

PY-CEI/NRR-ll57 L Page: 3 Page 4 of /V Rev.: 0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (TS 3.2.1) i All AVERAGE PLANAR LINEAR HEAT GENERATION RATES (APLHGRs) shall not exceed the result obtained from multiplying the applicable MAPLHGR values

  • by the smaller of either the flow dependent MAPLHGR factor (MAPFAC,) Figure 3.2.1-1, or the power dependent MAPLHGR factor (MAPFAC ) Figure 3.2.1-2.

p

  • These applicable MAPLHGR values ares i
1. Those that have been approved for the respective fuel and lattice type l

l as a function of the average planar exposure (as described by the NRC

(

approved methodology described in GESTAR-II) l or,

2. When hand calculations are required, the MAPLHGR as a function of the average planar exposure for the most limiting lattice (excluding natural uranium) shown in Figures 3.2.1-3 through Figure 3.2.1-6 for the applicable type of fuel.

CORE OPERATING PERRY UNIT - 1 LIMITS REPORT 7

i OM18 : PDB-F001 PY-CEI/NRR-il57 L Page : 4 Page C of_/y Rev. : 0 i

1 4

MPP No. 8767 Rev. 3/90 1.1 iiii IIII IIII IIII IIII IIIi IIII IIII IIII I E E I 1.0 -

r siii 4

Jr IIII F

IIII 2

e II II J'

IIII Jr IIII F

IIII s

IIII J

IIl l JF IIi1 0.9 -

.r iiii 5

IIII J'

III1

F IIII

.F IIf1 J

A IIII g4 J

IIII y

JP IIII 1

E I,,..mme!

1 N-um_

i a

S 0.8 = " -----------------------

I P_

i.msn.

g.

J 2

q 6

p_

l

,, lp j

.3 l

,, _s

,,,,,...s i

i_ _________

__sug,,

0.7 _

2F 11II v

i iiil i

J' I

1iiI 4

JF lIII F

11II e

IIII i

r Ii l l i

JF 1

1Ii1 l

2r t

u r

MAPFACg = MIN (1.0, 0.4574

.e. 0.006758F) 0.6 -

a s

\\

i i

0.5 1

I

\\

\\.

\\

\\

1 0

20 40 60 80 100 120 1

j CORE FLOW (% RATED), F j

FLOW DEPENDENT MAPLHGR FACTOR j

(MAPFAC )

f i

1 4

i 4

FIGURE 3.2.1-1 i

CORE OPERATING j

PERRY - UtlIT I LIMITS REPORT t

OH18: PDB-F001 PY-CEI/NRR-ll57 L Pages 5 Page 4 of /V Rev.: O Pl@P leo 8768 fiev. 3/90 1.1

,1 b

P 1.0 -

r r

J J'

JV AV JV 2,

2r 0.9 =

2r

.i c

t

l. l g

i d

l is, IE_

d l

l L_.

,,..i f

,b )__.LI. _.

.sE,..s d

n si,.,

2 o,

p g<

.r a-0.8 -

s 24 s

a w

J' r

O.7 J'

f ;

MAPFACp = 1.0 + 0.0052 (P-100) l 2r u.

for f

( 40% < P f 100% ; All core flows i

r' r 25% 1 P 1 40%

Core' flow'F 1 50%

1 a

ar ar 0.6 -

.dr' ph MA*FACp = 0.6 + 0.002 (P-40) w h

for 25% 1 P f 40% ; Core flow F > 50%

i 0.5 -

i i

i, i

1 0

20 40 60 80 100 120 CORE THERMAL POWER (% RATED), P POWER DEPENDENT MAPLHGR FACTOR (MAPFAC )

p t

FIGURE 3.2.1-2 CORE OPERATING PERRY - UNIT 1 LIMITS REPORT

l t

+

" * " * ~ "

~

13.5 M

EXPOSURE MAPLMGR

'i

<m (mwd /t)

(kWIft)

W g :i 13.0 y

0.0 11.9 g

3s j b

12.5 1.0 12.0 32,1 32.2 22.3 I

M4 12.o

, g2.1 BP8 SRB 219 C

<m; 12.0 p, 5.0 12.1 k

d16 10.0 12.2 H

ag 11.5 15.0 12.3

{.2 A.

11.0 9

20.0 12.1 i

g<

10.5--

-PERMISSIBLE 25.0 11.6 y,>

= * < "

mW REGION OF 30.0 11.2 g4g

>m 10,0-OPERATION 4$:

35.0 10.6 8i l

40.0 9.9 h g f 9.5 o

E1w i

2<

9.0 0

5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 k

$i ie 2

n AVERAGE PLANAR EXPOSURE (mwd /t)

CO MAXIMUM AVERAGE PLANAR LINEAR BEAT Enlm:

Intermediate MAFLEGE so w g

]h GENERATION RATE (MAPLEGR) VERSUS values are obtained

$E-0' M to AVERAGE PLANAR EXPOSURE,BP828R by linear interpolation tn M between adjacent points.

"~~

"h

'"O o

FUEL TYPE BP85RB219 o.,

Hs FIGURE 3.2.1-3

.t, G

B o

-. -... ~. _. _.. _ -. _

t 7

i

~

m W

l 13.5 t

[ ^I,I EXPOSURE MAPLHGR 12 9 12.,

(mwd /t)

(kW/ft) i M

Z 3

l13.0 f

g 0.0 12.0 12.

12.s 1

\\

C W

BP8 SRB 176 2

2

% F: 12.04 5.0 12.7

}

12.0 10.0 12.9 H

g W; 11.5

\\

~

2!

15.0 12.9 m02! 11.0

< E-'

ho.s 20.0 12.6 l

M <I:

X

[

m Wj 10.5--

PERMISSIBLE 25.0 11.7

>W-REGION OF d.2 30.0 10.8 73R

<Z 10.0--

OPERATION 2$':

35.0 10.2 EEE I

g hyI 40 0 9.6 9.0 EE i

Q W ;i

{

o a 4

O 5000 10000 15000 20000 25000 30000 35000 40000 45000 56000

'E" I

g

~$

i i

l ta O

i j

CO AVERAGE PLANAR EXPOSURE (mwd /t) gM O

MAXIMUM AVERAGE PLANAR LINEAR BEA Ents:

Intermediate MAPlaGR Mm GENERATION RATE (MAPLBGE) VERSUS values are obtained yy AVERAGE PLANAR EXPOSURE, BP8x8R by linear interpolation E

j between adjacent points.

e =

OH I

y FUEL TYPE BP8 SRB 176 d O:

FIGURE 3.2.1-4 i

y 4

3 i

8 j

1 k

}

p ar-l r --

e

13.5

  • e 13.2 /

EXPOSURE MAPLHGR i

f5 f

(

(MNdit)

(kN/ft)

N 13.0 jb.s

\\

12.5

~

0.0 12.4

  1. g 12.5 (9 2.4 1.0 12.4 i

8 c:

12.0 5.0 12.8 3

Z M

\\

7.0 Q

< m i11.5 l

mD 8.0 13.2

~

Z L

l' 3

10.0 13.5 I

11.0 N

  • 10.5 12.5 13.5

<m 10.4,

ZHi 20.0 12.5

)g M

25.0 m

9*5

- ^

I7#

35.0 10.4

<H 9.0

,,1 45.0 8.9 e e >-

l M<

" emes a ?;;

50.0 6.9

$$;8.5

\\

apg PERMISSIBLE

_M,

\\

,a s 5

< Z 8.0 REGION OF m-OPERATION n

2o gs E1" CO D H. 7.5 EE E d.

kd5 k

~E y lI:.

j o

7.0 4

M rn 2

6.5 mM N>

hd 6.0

[

1

~4 %

0 5000 10000 15000 20000 25000 30000-35000 40000 45000 50000 se o o l

k.

IE5 AVERAGE PLANAR EXPOSURE (MWdit)

", [

  • l 1

MAXIMUM AVERAGE PLANAR LINEAR BEAT Estas: 1. Intermediate MAPLEGE values O * **

GENERATION RATE (MAPLEGR) YERSUS are obtained b linear E

AVERAGE PLANAR EXPOSURE, GE8x8EB erpo

$!ts.

, en I

PUEL TYPE BS301E

2. This curve is a composite of the most limiting enriched fuel i

lattices. For lattice specific 1

-I lesent 1 FIGURE 3.2.1-5 valuesconsultSuhReload to the Supplement Licensiog Subm1ttal.

]j s

1

~

13.5 EXPOSURE MAPt.HGR n.2 L

NU WN 13 0 N

0.0 12.6 12.9 1 2. 5, 12.6

.12.5 1.0 I

8 c

W 7 L11.s 5.0 12.9 12*0 i

y X

7.0 13.2 t

11.5 mk.:

Z 8.0 H

U g 11.0

~

10.0 13.5 M

'10.5 12.5 13.5 l

<m y

zg 1o.4 l

20.0 12.5

< <.10.0 ag 25.0 11.8 p.

jq 9.5 35.0 10.A g <;

9.0 yg

,,,7 45.0 8.9 mM

(

-1

'~'

( g 8.5 PERMISSIBLE j 3 g1 1

7QR

_g 5

m uJ REGION OF l aus o

O"h.

O 8.0 OPERATION i

1 g

n F,

l

-l

\\

~ss ta o X<

7.5 i

kN k$

l M

o7" f

trs 7.0 w

i g

,,, i,

y@

~

6.5

+e l

4 trs s l

o%

6.0

$2 0

5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 O

AVERAGE PLANAR EXPOSURE (mwd /t)

,,,, o

  • E5 MAXIMUM AVERAGE PLANAR LINEAR NEAT Estas: 1. Interar-diate MAPLEGR values

}

GENERATION RATE (MAPLBGE) VERSUS are obtained b linear j

--~

AVERAGE PLANAR EXPOSURE, GE8x8EB

{

ts.

C*@

l FUEL TYPE BS301F

2. This curve is a composite of T'

the most limiting enriched fuel 3

lattices. For lattice specific o

i values consult Supplement 1

~

FIGURE 3.2.1-6 to the Supplemental Reload l

Licensing Submittal.

s..,

,--e

,a,.

.___,_...-_.---___________--_-._,-L

PY-CEI/NRR-ll57 L OM18: PDB-F001 Page il of ly Page 10 Rev.: 0 MININUN CRITICAL POWER RATIO (TS 3.2.2)

The MINIMUM CRITICAL POVER RATIO (MCPR) shall be equal to or greater than both the MCPR and MCPR limits at the indicated core flow, THERMAL POVER, i

deltaT*and$oreaveraEeexposurecomparedtotheEndofCycleExposure (EOCE)** as specified in Figures 3.2.2-1 and 3.2.2-2.

t SAMPLE t

ThisdeltaTreferstotheplannedreductionofratedfeegvater i

temperature from nominal rated feedvater temperature (420 F), such as j

prolonged removal of feedvater heater (s) from service.

l l

End of Cycle Exposure (E0CE) is defined as 1) the core average exposures at which there is no longer sufficient reactivity to achieve RATED THERMAL POWER with rated core flow, all control rods withdrawn, all feedvater heaters in service and equilibrium Xenon, or 2) as specified by

{

t j

the fuel vendor.

j l'

i CORE OPERATING PERRY - UNIT 1 LIMITS REPORT j

l

\\

i

~-..

i 1

OM18 :

PDB-F001 PY-CEI/NRR-1157 L Page :

11 Page 1 of /4 Rev.

O 1

w e em %.

mo d

I I I I I I a 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I E i

i lMCPR g = (1.8134 - 0.006948F) * [1.0 + 0.0032 (40 - F)]

l for r s 40s iI

' L"...

El1II 2P 1.7 _-

1111 JF mi i i r

IR I I JF

] RI I

.S' 1 IR I AV d

Ii11

.dF i

i II RU ar d

i Illi JP IllR AS' l

111 In 1.6 =

llll' i I

III i 1,

J II1l L

111 I 1

r iIII

'L

~

IIII B

IIII lt iiii

=

MCPRg= MAX (1.18, 1.8134 - 0.006948F) l III

'k 1.5 _

IIII 1L OF iiii t

F > 40s 111 I e

IIII

'k

'J' g

iiIi lL F

j g

Illi 1

J 5

III I

'L F

g j

iIII

'k Jr E

IIII 1,

f i

IIII 4

Jr III I

'L N

'i 1.4 -

iii i w

a f

Ill1 1

A L

musEunn'4 i

r

_______i",..

PERMISSIBLE in p

r REGION OF g

_p.

l.

i l

OPERATION r_______

g 1,3

..a m

ame j

g,,,,a g

l 11II L

l IIi

'k l II I i.

1II1 h

IIII L

1II i 1'

iiii RATE 0 OPERATING i

1*2 -

lll' LIMIT MCPR = 1.18 t

iIII III i 1.15 -

l l

L 0

20 40 60 80 100 120 1

i CORE FLOW (% RATED), F l

FLOW DEPENDENT MCPR FACTOR (MCPR )

f FIGURE 3.2.2-1 t-CORE OPERATING PERRY - UNIT 1 LIMITS REPORT

+

OM18 : PDB-F001 PY-CEI/NRR-ll57 L Page :

12 Page_13 of ;y Rev. : 0 2.3 iii,i,iiii,iiiiiiiiii;iiiiiii,i THERMAL POWER 255 f P f 405 2.2 CORE FLOW > 505 l

s r

l l

2.1 =

THERMAL POWER 255 f P f 405 a

-' -I-CORE FLOW f 505 2.0 =

n 1,

1.9 -

~

l PERMISSIBLE i

REGION OF 1.8 =

l g 1.7 =

Eo THERMAL POWER 405 < P f 705 3

^

2 ' l.6 -

i

,,n -

c

-- 1,

/

l i

i

. r w

m.

m I

k

'hJ P

b

_WF hm Q

' 'Q i

--" ' ~

THERMAL POWER P > 705 l

l 1.4 -

s l

2" BEFORE AND AT END OF CYCLE:

f u

All core average exposures

'u-l 1.3 =

and 0 f AT f 100*F and Core flow f 1055

- AFTER END OF CYCLE:

t 1.2 = ::

Core average exposure 'a EOCE b

and 0 f AT f 170*F and 1.1 -

Core flow < 1055 1.0 g

0 20 40 60 80 100 120 CORE THERMAL POWER (% RATED), P POWER DEPENDENT MCPR FACTOR (MCPR )

p FIGURE 3.2.2-2 CORE OPERATING PERRY - UNIT 1 LIMITS REPORT

a

~

PY-CEI/NRR-Il57 L O

Page A of _ f y.

LINEAR HRAT GENERATION RATE (TS 3.2.3) l The LINEAR HEAT GENERATION RATE (LHGR) shall not exceed:

i i

a.

13.4 kv/ft for the following fuel types:

1.

BP85RB219 2.

BP8 SRB 176 b.

14.4 kv/ft for the following fuel types 1.

BS301E l

2.

BS301F

~

i CORE OPERATING PERRY - UNIT 1 LIMITS REPORT l

>