b

' ].

MAR 2 01990!

MEMORANDUMFORi Jack E. Rosenthal. Chief Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data THRU: ~

George F. Lanik, Chief l-Reactor Systems Section GE and CE

. Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation

'of-Operational Data FROM:

Theodore C. Cintula, Reactor Systems Section Reactor Systems Section GE and CE Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data

SUBJECT:

REVERSE (BACKWARD) ACTING VALVE MANUAL HANDWHEELS This technical review report completes rqy investigation of reverse acting valve manual handwheels at nuclear power plants. The investigation was initiated by-the unsuspected reversed rotation of some atmospheric' dump valve i

manual handwheels that further complicated an ongoing transient at Palo Verde Unit 3.

A NUDOCS search found only two other events of confusion with the direction of' manual handwheel rotation at the nuclear power plants.

Neither of these events had potential to significantly complicate plant operations, so it would not appear that industry action-is appropriate.

@dMlY Theodore C. Cintula, Reactor Systems Section Reactor Systems Section GE'and CE Reactor Operations Analysis Branch Division of Safety Programs.

Office for Analysis and Evaluation l'

of Operational Data i

L g nclosure:

E

-.. D As stated i

Eh 8' Distribution:

i g PDR GLanik LSpessard RSavio, ACRS JWheelock, INP0 L

i u CastFiliFilib JRosenthal SRubin MTaylor, EDO DQueener,NOAC eg ROAB R/F EJordan GZech KRaglin, TTC

}/

tn>l DSP R/F Dross MWilliams PBaranowsky, NRR 5

TCintula TNovak KBlack HFaulkner, IP

)

i{\\

l ROAhD iAE0D R0 P:AE00

DSP:AE00 d]

TCintula:as GL nik JRosenthal l

12/n /89-Of/6/(0 g/gy/89 lSC FS.E CENTER CM

--