ML20033D024
| ML20033D024 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 11/24/1981 |
| From: | Koester G KANSAS GAS & ELECTRIC CO. |
| To: | Madsen G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| 10CFR-050.55E, 10CFR-50.55E, KMLNRC-81-140, NUDOCS 8112040601 | |
| Download: ML20033D024 (1) | |
Text
KANSAS GAS AND ELECTRIC COMPANY THE ELECTAC COMPANY GLENN L MOESTER WFCE P9E$lDENT. NvCLEam November 24, 1981 Mr. G.L. Madsen, Chief Reactor Projects Branch U.S. Nuclear Regulatory Commission
>b
' ' /,/\\
f 4' //'
fjf N..
Region IV L6
/
C, 611 Ryan Plaza Drive, Suite 1000 y
Q O{g3 (g
Arlington, Texas 76011 c
C^
U s.
jQ
'3
" ort KMLNRC 81-140 g*
Re:
NRC Docket No.30-482 l , -
g Ref: Interim Report dated June 29, 1981 transmitted h e~ T 9.gi GLKoester (KMLNRC 81-093) to GLMadsen, NRC g3 Subj : Final 10CFR 50.55(e) Report - Nonconforming Welds in Main Control Panels
Dear Mr. Madsen:
The purpose of this letter is to close out the concerns regarding weld discrepancies in the Main Control Panels and Auxiliary Relay Racks fur-nished to Wolf Creek Generating Station, Unit No. 1 by Comsip Customline Corporation.
The Architect / Engineer's evaluations of the seismic testing program and the results of the inspection program of the as-welded panels at the Wolf Creek site, as indicated in the Referenced Report, have been completed.
The conclusion of the Architect / Engineer and Comsip is that the as-built welds can withstand at least twice the stress levels calculated to occur i
during a safe shutdown earthquake (SSE).
This conclusion was reached through a combination of inspections, tests and analyses.
The final disposition of the weld discrepancies found in the Comsip panels indicates that no significant defects or deficiencies exist which would adversely affect the safety of the plant. Therefore, we have concluded that this matter is not reportable under Regulation 10CFR50.55(e). The test results and analyses are documented in a report which is available for your review.
1 If you require any additional information, please contact us.
Yours very truly, GLK:bb N
cc:Tvandel, NRC Site Inspector 8112040601 811124 j V PDR ADOCK 05000482 S /
S PDR
/
ji O 201 N. Market - Wichita, Kansas - Mail Address: PO. Box 208 I Nchita, Kansas 67201 - Telephcne: Area Code.316) 261-6451
-