ML20033C816

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 810916-1015
ML20033C816
Person / Time
Site: Waterford 
Issue date: 11/17/1981
From: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20033C815 List:
References
50-382-81-25, NUDOCS 8112040326
Download: ML20033C816 (2)


Text

,

DESIGNATED ORIGI3ATJ APPENDIX A certified By, M#'

NOTICE OF VIOLATION Louisiana Power and Light Company Docket No. 50-382 CPPR-103 Based on the results of an NRC inspection conducted during the period of September 16-October 15, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980), the following violations were identified:

Criterion V of 10 CFR 50, Appendix B, states that activities affecting quality shall be prescribed by instructions, procedures or drawings of a type appropriate to the circumstances and that these activities shall be accomplished in accordance with these instructions, procedures or drawings.

Ebasco Care and Maintenance Instructions (CMI) for the safety-related equipment require that heaters be energized, equipment be protected from damage, dust covers be provided, and valve openings be protected until piping is ready to be connected.

Contrary to the above, the NRC inspectors observed at various times during the period of September 16-October 15, 1981, that the following conditions existed:

(a) Motor space heaters were not energized as required on safety-related motor operated valves:

2SI-V809A 2SI-V810A 2SI-V154-1A2 2SI-V154-9Al (b) A supplemental heat scurce (wann air blower) was not energized as required for the heater terminals on the underside of the pressurizer.

(c) Temperature detector, TE-CC-7021B, was broken off at Component Cooling Water Pump B.

(d) Component Cooling Water Pump A/B was not being protected.

(1) A li ton load-rated come-a-long was lying on the pump.

s (2) A ladder was placed on the pump's motor.

(e) Terminal covers were not in place to provide protection for safety-related motor operated valves:

2SI-V1539B1 2SI-V811B 2SI-V327A 2SI-V1547-B3 8112040326 811117 PDR ADOCK 05000382 G

PDR t

2 (f) Dust covers were missing from openings on:

Generators A and B of the Emergency Diesel Generators Emergency Diesel Generator Control Panel 3B-S Low Pressure Safety Injection Pump B (g) Protective covers for open ends were missing from safety-related valves:

3CC-V625 2MS-V1505 2MS-V1510 2MS-V1511 This is a Severity Level V Violation (Supplement II.E).

Pursuant to the provisions of 10 CFR 2.201, Louisiana Power and Light Company is hereby required to submit to this office within 30 days of the date of this Notice, a written statement or explanation in reply, including:

(1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further items of noncompliance; and (3) the date when full compliance will be achieved.

Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation.

Consideration may be given to extending your response time for good cause shown.

The responses directed by this Notice are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

M Dated November 17. 1981 e

'G. L. Madsen, Chief R. actor Projects Branch i

l l

l

!