l y-..
OCT 0 6 E Docket No. 99900047/81-01 Westinghouse Electric Corporation Nuclear Components Division ATEN: Mt. T. D. Miller Product Assurance Manager P. O. Box 19218 Tampa, FL.33686 Gentlemen:
Thank you for your letter of August 7,1981, in response to our letter datdd July 7,1981. As a result of our review, we find that additional infomation is needed. Specifically, for Item A:
(1) please provide the basis for your statement that welders JA and BL performed bead tenter repair-s, with both using 1/8" and 3/32" incoesi electrodes, when the weld material / welder log showed that JA was issued only 3/32" electrodes and BL was issued only 1/8" electrodes; (2) please provide the basis for your conclusion that welder FG did not use the 5/32",9018 electrodes for pressure boondary welding, and indicate if the applicable Quality Contrn1 Weld Log (QCWL) was corrected to reflect that conclusion; (3) please provide the basis for your conclusion that welder HN did not utilize the 3/32" Inconel electrodes for pressure boundary welding, and indicate if the QCWL was corrected to reflect that conclusion; and (4) please provide the basis for your conclusion that welder SD did not use 3/16",9018 electrodes for pressure boundary welding.
Please provide this additional information within 25 days from the date of this letter in order that we may complete our review.
Sincerely, hg signed bD povs*
Uldis Potapovs, Chief Vendor Inspection Branch 8112010514 811127 PDR GA999 EMWEST 99900047 PDR I
)
" ' " > RI.V...Y
...........,N............... [3..
D:I&EST smq CI:RI 7 SC:RIS BC:VIB N/\\'
f' UPotapovs-JEGagli p'
J 1 ins-tEETim e aW
/r$.IB'arnes"
- 1.0/..\\. /.8.1..10hp/.81.,,,,,
10 _./81
- > 10/.1/al.
W..l..L8)..
sac ronu ma no soi nacu 0240 OFFICIAL RECORD COPY
"" "*-32m'