4 Form NRC418 U.S. NUCLE AR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages 1.h)' Certif ate Number 1.(b) Revision No.
1.(c) Package Identification No.
1.(d) Pages No. 1.(e) Total No. Pages 5958 2
USA /5958/B 1
3
- 2. PREAMBLE 2.(at This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations f 49 CFR 170-189 and 14 CFR 103) anr1 Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packagirg and contents dewribed in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of a
- Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**
2.(c). This certiricate does not relie.e the cor: signor from compliance with any requirement of the regulations of the U.S. Department of Trr.nsportation or other applicable regulatory agencies, including the government of any country through or into which the package wili be transported.
- 3. This certificate is issued on the ba,is of a safety a talysis report of the package design or application-3.(a)
Pr:1,ared by (Name and address):
3.(b)
Title and identificatian of report or application:
Allied Chemical Corporatidn Allied Chemical Report 550 Second Street No. ICP-1077, June 1975 Idaho Falls, ID 83401 7.1-5958 3,,
g,,,, y,,
- 4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 be'ow.
5.' Description of Packaging and Authorized Contents, Model Number, Fissile Class Other Conditions, and
References:
(a)
Packaging (1) Model No.:
ICPP Krypton Shipping Container (2) Description Packaging for large quanti The containment vesselisanominal1.5ft}iesofcompressedkryptongas.
compressed gas cylinder meeting the requirement of 00T Specification 3A or 3AA. The primary containnent l
vessel is held within a lead filled shield container which is further held within a phenolic foam filled thermal insulating container. The overall container size is 30 inches in diameter by 83-1/2 inches long.
A tubular steel support frame assembly is welded to the surface of the insulating container. The package gross weight is 5,200 pounds, (3) Drawings The packaging is constructed as shown in Figures 1, 3, and 4 and as specified in Sections III.B and III.C, Allied Chemical Report No. ICP-1077, June 1975; the packaging for the D0T Specification 3AA cylinder is also subject to the modifications shown in Figure A-3 and specified in Sections III.B and III.C, Exxon Report No. ENIC0-1069, January 1981.
0111240089 811112-PDR ADOCK 07105958 C
h.+
w 43 Ms Page 2 - Certificate No. 5958 - Revision 2 - Docket No. 5958 Q
'ps y
(b) Contents
~_
bi 46-(1)
Type and form of material 4
Krypton-85 gas in mixture with other gases.
(2) Maximum quantity of material per packcge Radioactivity not to exceed 74,000 CI. Maximum in'ternal decay heat not to exceed 293 watts. Maximum volume of Krypton-85 gas shall not exceed 1488 7. at S1P (1 atm, 25 C).
6.
The maximum initial fill pressure shall not exceed 35 atu at 25'C.
7.
There are two optional contsinment vessel configurations:
(a) A D0T Specification 3A compressed gas cylinder; equipped with the Kerotest valvc (No. 440X70) specified and assembled in
. accordance with Section III.A of Allied Chemical Report No. ICP-1077, June 1975.
(b) ADOTSpecification3AAcompressedgascylinder;equipphdwith a Nupro bellows valve, Series T, as specified and assembled in accoraance with Section III.A.(2) of Exxon Report No. ENIC0-1059, January 1981.
8.
The DOT Specification 3A or 3AA gas cylinder shall be certified for an operating load of 2015 psig, before first use and at least once every 5 years by testing to 3360 psig.
9.
Each packaging, before first use; and after every third use, or within the 12 months preceding any use, whichever comes first, shall be leak tested using a method capable of demonstrating that the maximum gas leakage rate from the ;)rinary gontainment vessel and closure valve is less than 1 x 10- atm-cm /sec at normal operating conditions (193C,55atminternal).
- 10. Before each use the primary containment vessel and closure valve shall be leak tested using a method capable of demonstrating that the maximum krypton release rate from the primary containment vessel and closure valve is less than 0.278 uCi/sec at normal operating conditions (193*C, 55 atm internal).
- 11. The package authorized by this certificate is hereby approved for use under the general license provisions of Paragraph 71.l?(b) of 10 CFR Part 71.
Page 3 - Certificate No. 5958 - Revision 2 - Docket No. 5958
- 12. Expiration Date: October 31, 1982.
R_EFERENCES E
Allied Chemical Corporation Report No. ICP-1077, June 1975.
. Ex in Nuclear Idaho Company, Inc. Report No. ENIC0-1069, January 1981.
l FOR THE U.S. NUCLEAR REGULATORY C0fEISSION
[b Charles E. MacDonald, Chief i
Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date:,
{
'I I
J f
l I