ML20032D461

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 9154,Revision 0,for Model 858
ML20032D461
Person / Time
Site: 07109154
Issue date: 11/04/1981
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20032D458 List:
References
NUDOCS 8111170035
Download: ML20032D461 (2)


Text

.

e 4.

For-NRC-618 U.S. NUCLE AR REGULATORY toMMISSloN th2[R CERTIFICATE OF COMPLIANCE -

1 For Radioactive Materials Packages 1.4 1 Certificate Number 1.(b) Revision No.

1.(c) Packace identificatio N.

1.(d) Pages No. 1.(e) Total No. Pages 9154 0

USA /9154/B 1

-2 2_ DRE AMBLE 2.lal This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Se:tions 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.tb)

The pachging and contents described in item 5 besow, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regutations, Part 71, " Packaging of Radioactive Materiats for Transport and Transportation of Radioactive Material Under Certain Conditions."

t 2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation ot other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.lal Pre Technical dared by (,Name and address):

3.(b)TechnicaTentification pf report [nc.plicatioIication dated Title and v r ap perations, Inc.

Operations, app Northwest Industrial Park October 27, 1981.

Burlington, MA 01803 H4M 3.(ci oocket No.

4 CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

gf Pa k ging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

5 eser (1) Model No.: 858 (2) ~ Description A steel encased, uranium shielded Gamma Ray Projector.

Primary components consist of an outer steel shell '(21" x.12" x 14.62"), internal bracing, polyurethane potting material, depleted uranium shield (4.0" min. thickness),

and a zircalloy "S" tube (0.467" OD x 0.385" ID). The contents are securely positioned in the zircalloy "S" tube by a source cable locking device and shipping plug. Tamper-proof seals are provided on the packaging and a 1/4-inch thick steel shipping plate is bolted over the source locking mechanism for additional protection during transport.

The total weight of the package is approximately 502' pounds.

(3)

Drawings The packaging is constructed in accordance with the following Technical Operations,.Inc. Drawing Nos.:

85890, Sheets 1, 2, 3, 4, 5, and 6 of 6, Rev. 0 66025, Sheets 2 and 3 of 3, Rev. A.

gg 8111170035 81110T PDR ADOCK 07109154 C

PDR 1

Page 2 - Certificate No. 9154 - Revision No. 0 - Docket No. 71-9154' 5.

(b), Contents (1) Type and form of material Cobalt-60 as sealed sources which meet the requirements of special formasdefinedin10CFR571.4(o).

(2) Maximum quantity of material per package 110 curies 6.

The source must be secured in the shielded position of the packaging by the shipping plug, source assembly, and locking device.

The shipping plug, source assembly'used must be fabricated of materials capable of resisting a 1475'F fire environment for one-half hour and maintaining their positioning function. The ball stop of the source assembly must engage the locking device. The flexible cable of the source assembly and shipping plug must be of sufficient length and diameter to provide positive positioning of the source in the shielded position.

7.

The' nameplates must be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.

i t

8.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

9.

Expiration date:

November 30, 1986.

REFERENCE Technical Operations, inc. application dated October 29, 1981.

FOR THE V.S. NUCLEAR REGULATORY COMMISSION

[b Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date: NOV 0 41931 6