_

PHILADELPHIA ELECTRIC COMPANY 23O1 M ARKET STREET P.O. DOX 8699 1881 -1981 PHILADELPHI A. PA.19101 1215)841-4502 VKE PRESIDE pet

.............m.......<

nov 04198%

g lQ

[d/

r f[ k'f),

Q, Mr. Darrell G. Eisenhut, Director Division of Licensing

' b,< k,,1 g

U. S. Nuclear Regulatory Commission

). NOVO 61981>I Washington, DC 20555 4

u.a. m ani n G QIE so % uPS

,.-6

Subject:

Limerick Generating Station, Units 1 6 2 b.

ff Dockets No. 50-352 and 50-553

/,

g

Dear Mr. Eisenhut:

Philadelphia Elcetric Company has reviewed the Limerick Generating Station Units 1 0 2 coolant pressure boundary piping and fitting material, including wel metal, to determine conformance with the material selection and process guidelines set forth in NUREG-0313, Revision 1, dated July, 1980 and transmitted bv ur 1ctter of February 26, 1981.

Our review covered the following systems:

1.

Residual !! cat Removal 2.

Low Pressure Coolant Injection 3.

Core Spray 4.

Reactor Recirculation k

5.

Reactor hater Cleanup S

These systems meet the requirements of NUREG-0313, Revision 1 with the following exceptions:

1.

Type 304 stainicss steel has been used between outboatd and inboard isolation valves on the RIIR, LPCI, and Core Spray Systems.

2.

Valve FOOD on the RilR Shutdown Cooling Suction Line is made of forged type 316 stainicss steel.

In these cases the temperature during normal operations is below the threshold temperature for IGSCC occurrence.

3 Valve F065 on the LPCI System and Valve F007 on the Core Spray System are made of forged type 316 stainless steel.

c 81110906'2 811104 d

PDR ADOCK 05000352 r

PDR QO A

s n i

7.-

A o These valves hr.vc had type 3161 safe ends installed by use of a IIcat Sink h'elding Prccess to mitigat e IGSCC.

In the event that you have any questions or comments, please do not hesitate to contact us.

Sincercly, 9(r$ V/L h

/

/