. UNITED 5TATES NUCLEAR REGULATORY COMMISSION N
,I REClON IV Qx f-ett RYAN FLAZA l., RIVE, SUITE IW AR LINGTON, TEXAS 76011 ugust'18, 1981 Gentlemen:
The enclosed IE Bulletin supplement is fontarded for action.
A written response is required. To assist NRC ir evaluating the value/ impact of each bulletin and supplement on licensees, it would be helpful if you would provide an estimate of the manpower expended in the review and preparation of the report (s) required by j
the bulletin supplement.
Please estimate separately the manpower associated with corrective actions necessary following identification of problems through the bulletin supplement.
If you need additional infonnation regarding this matter, please contact this office.
Sincerely, k
mS TL
{
arl V. Seyfri Director
Enclosures:
1.
IE Bulletin 81-02, Supplement 1 2.
List of Recently Issued IE Bulletins 3
Ib o w m w a w#ei 7 /- &
G
IE BULLETIN N0. 81-02 Licensee Facility / Docket Number _
g, Arkansas Power and Light Conpany Arkansas Nuclear One,' Unit 1 & 2 Little Rock, Arkansas 50-313; 50-368
~
Nebraska Public Power District Cooper Nuclear Station Columbus, Nebraska 50-298 0maha Public Power District Fort Calhoun Station Naha, Nebraska 50-285 Public Service Company of Colorado Fort St. Vrain Generating Station Denver, Colorado 50-267 Gulf States Utilities River Bend Beaumont, Texas
~0-458; 50-459 Houston Lighting & Power Company South Texas Project Houston, Texas 50-498; 50-499 Kansas Gas & Electric Company Wolf Creek Wichita, Kansas STN 50-482 Louisiana Power & Light Company Waterford-3 New Orleans, Louisiana 50-382 Texas Utilities Generating Company Comanche Peak Steam Electric Station Dallas, Texas 50-445; 50-446
<2
-'[ (kkD
\\9 3 $87
[u
%gt 1ai s
i
//
_ /-/-R t
s SSIN No. 6820 Accession No.:
8011040283 IEB 81-02, Supp. 1 UNITED STATES NUCLEAR REGULATORY COMMISSION OF' ICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 IE Bulletin No. 81-02 August 18, 1981 Page 1 of 4 FAILURE OF GATE TYPE VALVES TO CLOSE AGAINST DIFFERENTIAL PRESSURE Description of Circunstances:
IE Bulletin No. 81-02, " Failure of Gate Type Valves to Close Against Differential Pressure," identified several gate type valves that had been shown by tests and/or analyses by Westinghouse to have a potential for not closing against differential pressure.
As a part of its ongoing analysis program, Westinghouse Electro-Mechanical Division (W-EMD) has applied the analytical methods developed for valves discussed in IE Bulletin 81-02 to the remaining motor operated gate valves that they manufacture.
These analyses predict that closure problems could also be anticipated with 6, 8, 10, 12, 14, 16, and 18-inch nominal size valves in addition to 3-and 4-inch low pressure valves.
Thus, the entire line of W-EMD manufactured motor-operated gate valves has the potential for not closing against differential pressure.
Westinghouse has indicated to NRC that they have notified all of their domestic nuclear customers of this problem.
When the valves were provided as original scope of supply, they also identified the recommended corrective action necessary to assure valve closure under the system service conditions that their records show the valves will experience.
Where the valves were provided as spares or replacements, they indicated the threshold differential pressure across the valvts above which closure could not be assured under the utility order equip-ment specification conditions.
l A list of power reactor facilities that Westinghouse believes to have the potentially affected valves is given in Table 1.
However, this list, as well as Westinghouse's notifications, does not take into consideration the fact that the valves may have been tra..sterred between facilities.
In addition, the Westinghouse determinations of operability and corrective action do not take into consideration the fact that the valves may have been transferred between systems or that the systerr service conditions may have changed through design evolution.
IEB 81-02, Supp. 1 s
August 18, 1931 Page 2 of 4 It is therefore essential that all facilities verify the presence or absence of W-EMD manufactured motor-operated gate valves and also verify their ability to close under the current and/or intended service conditions.
Actions To Be Taken by Licensees:
1.
Within 30 days of the issuance date of this bulletin supple:nent, ascertain whether any W-EMD manufactured motor-operated gate valves have been installed, or are maintained as spares for installation, in safety related systems where they are required to close against a differential pressure.
2.
If no valves, other than those reported in response to IE Bulletin 81-02, are identified, report this to be the case.
No further action is required.
3.
If any valves are identified as being installed, verify that they are capable of closing under their current limiting normal and post accident service conditions.
If such cannot be shown, take corrective action on these affected valves and evaluate the effect that failure to close under any condition requiring closure would have on system (s) operability pursuant to the facility Technical Specifications for continued operation.
4.
If any valves are identified as spares, verify that they are capable of closing under their intended limiting normal and post accident service conditions.
If such cannot be shown, either modify thi affected valves so that they are qualified for the intended service or 30tain qualified replacements prior to installation.
5.
Within 45 days of the issuance date of this bulletin supplement, submit a report to NRC listing the affected valves identified in safety-related systems, their service or planned service, and the maximum differential pressure at which they would be required to close, the safety consequences of the valves failing to close, the corrective action taken or planned, and the schedule for completing the corrective action.
Actions To Be Taken by Construction Permit Holders:
1.
Ascertain whether any W-EMD manufactured motor-operated gates valves are or will be installed, or maintained as spares for installation, in safety-related systems where they are required to close against a differential pressure.
2.
If no valves, other than those reported in response to IE Bulletin 81-02, are identified, report this to be the case.
No further action is required.
3.
If any valves are identified, verify that they are capable of closing under their intended limiting normal and post accident service conditions.
If such cannot be shown, either modify the affected valves so that they are qualified for the intended service or obtain qualified replacements prior to startup.
IEB 81-02, Supp. 1 August 18, 1981 Page 3 of 4 4.
Within 90 days of the issuance date of this bulletin supplement, submit a report to NRC listing the affectea valves identified for use in safety-related systems, their planned service, the maximum differential pressure at which they would be required to close, the safety consequences of the valves failing to close, the corrective action taken or planned, and the schedule for completing the corrective action.
For those cases in which reports have already been submitted in accordance with the Technical Specification, 10 CFR Parts 21 and/or 50.55(e), this information need not be resubmitted.
Rather, licensees or construction permit holders should reference this earlier report and submit only the additional information requested above.
Reports, signed under oath or affirmation under the provisions of Section 182a of the Atomic Energy Act of 1954, shall be submitted to the Director of the appropriate NRC Regional Office and a copy shall be forwarded to the Director of the NRC Office of Inspection and Enforcement, Washington, D.C.
20555.
If you need additional information regarding this matter, please contact the appropriate NRC Regional Office.
This request for information was approved by OMB under blanket clearance number 3150-0012 that expires December 31, 1981.
Comments on burden and duplication should be directed to the Office of Management and Budget, Reports Management Room 3208, New Executive Office Building, Washington, D.C.
20503.
Attachment:
Table 1, Partial List of Plants With Valves Manufactured by W-EMD
7 1
IEB 81-02, Supp. 1 August 18, 1981 TABLE 1.
PARTIAL LIST OF PLANTS WITH VALVES MANUFACTURED BY W-EMD Valves Supplied as Valves Supplied as Spares or Replacements Original Scope of Supply Arkansas Nuclear One 1 Beaver Valley 2 Beaver Valley 1 Braidwood 1, 2 Callaway 1, 2 Byron 1, 2 Catawba 1, 2 Callaway 1, 2 Diablo Canyon Comanche Peak 1, 2 Farley Shearon Harris 1, 2, 3 Indian Point 2 Marble Hill 1, 2 Midland 1, 2 Seabrook 1, 2 Oyster Creek South Texas 1, 2 Prairie Island 1, 2 Summer 1 St. Lucie 2 Vogtle 1, 2 San Onofre 1, 2, 3 Watts Bar 1, 2 Summer 1 Wolf Creek 1 Surry 2 Wolf Creek 1 i
l l
I l
l
IE Bulletin No. 81-02, supp. 1 August 18, 1981 RECENTLY ISSUED IE BULLETINS Bulletin Subject Date Issued Issued To No.
80-24 Preventie of Damage 11/21/80 All power reactor facilities Due te
. ;r Leakage with Operating license (0L)
Inside containment or Construction Permit (CP)
(October 17, 1980 Indian Point 2 Event)
Sup. 4 Failure of Control Rods 12/18/80 To specified BWRs with Bulletin to Insert During A Scram an Operating License (OL) 80-17 at a BWR and All BWRs with a Construction Permit (CP) 80-25 Operating Problems with 12/19/80 All BWR facilities with Target Rock Safety-Relief Operating License (OL)
Valves at BWRs and specified near term Operating License (0L)
BWR facilities and all BWRs with a Construction Permit (CP) 81-01 Surveillance of 1/27/81 All power reactor Mechanical Snubbers facilities with an Operating License (OL) and to specified facilities with Construction Permit (CP) 80-17, Failure to Control Rods 2/13/81 All BWR facilities Sup. 5 to Insert During a Scram with Operating License (OL) or Construction Permit (CP) 81-01 Surveillance of Mechanical 3/4/81 All power reactor facilities Rev. 1 Snubbers with an Operating License (OL) and specified facilities with a Construction Permit (CP) 81-02 Failure of Gate Type Valves 3/9/81 All power reactor faclities to Close Against Differential with an Operating License (0L)
Pressure or Construction Permit (CP) 81-03 Flow Blockage of Cooling 4/10/81 All nuclear power Water to Safety System facilities with Components by Corbicula an Operating License (OL)
Sp. (Asiatic Clam) and or Construction Permit (CP)
Mytilus Sp. (Mussel)
Enclosure