.t October 22, 1981 Docket No. 50-320 g

v O

U u. CT2 9 IS8lk b'2-Mr. John J. Barton Acting Director of TMI-2 Metropolitan Edison Company Q

cD @ ma p P. O. Box 480 V-8 Middletown, PA 17057 N

Dear Mr. Barton:

This is in response to Mr. Hovey's letter LL2-81-0214 of September ll,1931, concerning the use of EPICOR-II for SDS effluent polishing, which included Metropolitan Edison's plans for EPICOR-II liner radioisotope loading and disposal.

In that letter, Met-Ed proposed to load the EPICOR-II liners to a maximum concentration of 1 uc/cc of isotopes with half lives greater than five years and dispose of the liners (with resins in a dewatered, but unsolidi-fled fom) at the bottom of a disposal trench (approximately 10 meters deep).

Even though not specifically stated, we understand that Met-Ed is proposing to dispose of the EPICOR-II liners at an arid disposal facility.

Prior to final promulgation of Part 61, your praposal would be allowable under current NRC regulations. Subsequent to final promulgation of 10 CFR 61, the remaining waste covered by your proposal would require 'in exception to the Sr90 concentration limit (0.04 uc/cc) in Table 1 for Clars A waste if the regulation is approved as proposed by the staff.

The NRC staff has performed an evaluation of the waste and disposal conditions proposed by Met-Ed.

The evaluation indicates that the proposed conditions would be acceptable for the waste to be considered a Class A unstabilized waste under 10 CFR 61, provided all other requirements of the proposed 10 CFR 61 for Class A wastes were met (e.g., the waste is segregated from Class B and C stabilized wastes and disposed of in a separate trench).

d.

= the existing commercial disposal sites are regulated by the individual St 6es, acceptability of the waste form and disposal conditions would rest with them. However, it is our position that we would recomend acceptance of your proposal.

e111ocogg, g,g......

sunsaur)

PDRADOCK05cohhfo PDR omp

..[.

.g.

Lune row us. io so, uncu c24o OFFICIAL RECORD COPY

_ _ _ _ _ __ _g

T

!!r. John J. Barton OCT 2 2 1981 It is requested that you continue your careful analytical prograta to detertaine the content of these isotopes in the various waste containers to ensure conformance with the disposal criteria discussed above.

Sincerely, Bernard J. Snyder, Prograa Director TifI Progra.a Office Office of Nuclear Reactor Regulation cc: See Service Distribution List Distribution:

Docket No. 50-320 PDR LPDR TERA TMI R/F TMI Site R/F BJSnyder LBarrett AFasano RConte LChandler IE (3)

ACRS (16)

Olynch RWeller HRDenton Service List (43) i I

orncr>

TM P l

'5"""'"')

B. fpro,er si o.u )

10/J M 1 l nac romu 3is,io 80, naco 02' OFFICIAL RECORD COPY

ar. Galt asset notregelttas tessen Causesy s

nr. J. J. Barten Three Nile Islane Alert. lac.

23 5esta.21st street f.*g

"'a"eo "

-r-

. a i7=

eeios.n.,4 iro 7

  • e. J. f. Larsan g g Swcervisor. ;nt t4 UCeasieg CaessavtMe. Pa 19320 SPU MuClear Carmoretten P.3. los '80
m. taren Snelsen sicalatoun 74 {70$7 snelems, normen, aetsman a votes 172S I Street. 2.W.. Setts $06 unnetectes. 3C 20006 e.1. G. Wa,llace Pts Ltcasets manager GPU seretta carcaretten gerg 3. msffama 100 tatersece P8rMF 3eumate Caunty Camenstemer Partisee8y nJ 07054 3mmente Cassty Courtantsee Fremt see parest Street
e. J. 8. Ltherema. Enest*e

.earrestery. 74 17101 tertest. Israels. Literuna 26 Greamsy gaseremmet Putlicattens $esties ese vert. NT 1024 State of Lthrery of Pennsylvente tem 1808 testattem Sutletag nr. S. F. fremertega. Esentre narr9seurg. PA 17127 Shas. Pitisme. Petts & Treuertege less N Street. 2.W.

Or, tamare 0. herta mesatsgems. OC 20036 teare of Sumeressers tessusescry famosate 3r. Welter e. JereEA -

179 H Geyert Chrta Read 301 W. Outer Ortoe stealetems. 74 17067 Qet 4189e. IE 378 31 G. 5. (mtrematal Smtection Agency Dr. Lines W. Little angten III Office 504 nerettage 3rtve ATTE: 115 Caereteeter saletgn. nC 27512 Curtis Sutletag (Stata Meer) 64a ame usinut Streets tario d. Carter, tsentre Pettaselseta. PA 19106 SOS Esecutive nesse P. 3. Ses 2357 tanssia causty Offica tamegency marresamtg. P4 17f20 s

Court nouse. neun 7 mammresia Mars Ceams Prest ame Marest Streets lit E.3 mets Caettst Outistag meretseurg. PA 17101 narrtseorg. 74 t7t20 h of Emternematal teneurtes (11re metes, tsguere AT7Et Otrector. Office of Skoleum narums. Aetsman & instss asetetsgical nacith 172S I Street. e.u.. Sette 506 P. 4. Den 20s3 unentestem. GC toons morressurg. 74 17108 nr. Steves C.18mily Essesmer's Office of stata 30s 1. perset Street plaaming one Osweleemmat mesamescsourg. M 17 TBS Afftt Caeretnatar. Pennsylmete Clonet aganuse P. O. Sem 1323 nr. Dumas seresay serens of tastation Protecties norressurg, Ps 17120 P. G. Sea 2363 marresserg. M 17120 mre. Rhoes 0. Care laN merene Orive nr. marvee I. Lests morresenry. M 17109 6504 8esafere Terrace P4tlaeolpata. PA Igleg ur. Atchsre asserts fles Petrtet 412 perust $treet ns..ane Lee

t. 3. 3. asa 2521 geresseorg. 74 1710$

(tters. Pa 17319 nr. anaert B. Sersum amarern a yttcss ualter s. Camen. Cassemer advocata muslaar Passe Generation 01risten Damertment of Jestfee Seite 420. T73$ 014 Georgete.m nesee Stremascry $mence, tota Fleer marriseurt. Pa 17127 totasses. "O 20014 (vem e. Estts. (sestro senart L. Enues. (soutre Atent s 5afety an$ Litsesteg 15tre assistant 144tCitar W. 5. Euslese sessiatory cams sstee samme ano anerous essaingten. 3C 20$55 P. 4. 8es. P 407 m. Front Street aammet Safety ane Licenstag Seere Ptaal marrisaur1. PA 17100 W. S. 9usteer seculatory Causta sten Jane (, stantca. Chatreersen maastagene. 3C 20544 3ausate Ca. Sesre of Camissteners Sensata Caunty Caurtneune Frost and Partet 5treets atsmec Safety ans Llcamstag assest Penel narrtsourg. 74 17101 W. 5. megleer segolatory Commission easategten. 3C.'C55$

.aos,t 3.,enare Chesassea Energy aillaate Catastine and Service Segtten U

I. E'.Elter leggiatory Camassstes 303t,unteet.ter Street p

u.mge n. OC 20.

s.re. 0 nm C,

s e, osfore Jussta n. sessinetse tat teatrossental Casittien en anstleer Peser

g;,e,',;;1,s.,

-..want,a 5ta to..

,1 t, T

1 v.cmy are. -, e ve... -

an. Fr een 8erryotII. 3etreerson stegiate 5eutmre. Chatreme e

Casittien for escieer *euse 81aat Cititans 'se a safe Envoconsent Posteenesent 264 set tee Street 2810 Grensen Grove Lampyne Pa 17043 et tsington. :( 19408 e

asily $. seca aatt.esclear Grows leerssenting fers 245 s. ratlassionia Street fors pa 1Teos

onn Leven. (sevire e ansylvania Pvette utt11 ties Casetsstem s

P. 3. Ses 225$

earettausg. 74 17120 Jeroen 0. Conneagnaa. Esestre j

res. Farr ans C netagnan 2320 4 Secone street

=are sTK)o pa 17110

s 1

Acceptability for Disposal of Unstabilized TMI-2 Dewatered Resin Wastes Having Sr Concentrations Greater than 0.04 uc/cc

Purpose:

The purpose of this evaluation is to determine the acceptabiggty of disposing of unstabilized TMI-2 dewatered resin wastes hayfngSr concentrations greater than 0.04 ue/ce, the upper limit for Sr concentrations for Class A wastes specified in the proposed 10 CFR 61.

References:

1.

Proposed rule, 10 CFR 61, Licensing Requirements for Land Disposal of Radioactive Waste, Federal Register, Vol. 46, No.142, July 24, 1981, pp. 38081 - 38105.

2.

Draft Environmental Impact Statement on 10 CFR 61 " Licensing Require-ments for Land Disposal of Radioactive Waste," NUREG-0782, Appendix G.

3.

INVERSI code run, June 12, 1981.

90 Results:

Disposal of TMI-2 dewatered resin wastes having Sr concentrations less than 24 uc/cc would be acceptable for disposal in an unstabilized condition at depths greater than 5 meters at an arid disposal site.

If other isotopes listed in Table 1 of the proposed 10 CFR 61 are also present, these isotopes would also need to be accounted for using the concentration ratio factor identified in Table 1.

Evaluation:

The proposed rule for low-level waste management, 10 CFR 61, includes a waste classification system (Reference 1).

The upper coggentration limit for the disposal of unstabilized wastes (Class A) for Sr is given as 0.04 uc/cc.

This limit was determined by evaluating the effects of intruder pathways et a reference disposal facility.

The intruder pathways included construction and agricultural cases.

The i

2 draft environmental impact statement for 10 CFR 61 (Reference 2) provides a detailed description of these pathways.

The allowable concentrations for the intruder pathway evaluations in the waste calssification system are based on a performance objective that the intruder receives an annual dose to the whole body of less than 500 mrem.

The waste classification system in Reference i requires that wastes buried at normal depths (includes diggosal at less than 3 meters) at either humid or arid sites having Sr concentrations greater than 0.04 uc/cc be stabilized. However,10 CFR 61 does provide for exemptions if the specific disposal conditions provide assurance that the performance objectives are met.

In evaluating certain options which could provide the assurance that the performance objectives are met, several 90 alternatives could be considered for unstabilized, wastes with Sr concentrations greater than 0.04 uc/ce.

These alternatives include:

burial at depths greater than 5 meters (that is, with an intruder barrier), burial at an arid site, or a combination of these.

Because the proposed waste would be unstabili ed, the wastes would be disposed of in a trench containing Class A wastes.

Class A wastes would be segregated from the stabilized Class B and C wastes.

The basic assumptions in the Class A waste scenarios for normal depths and deeper depths (greater than 5 meters) are as follows:

1.

The reference disposal site is located in a humid Southeastern site.

2.

Inadvertent intrusion is made af ter institutional control is lost following an active control period o2 100 years.

3.

At the time of intrusion the wastes have degraded to the extent that they are unrecognizable as waste and undistinguishable from soil.

4.

The waste degradation takes place at a rate independent of site location.

That is, the degradation is the same for an arid and a humid site.

5.

Agricultural activities occur only in wastes located less than 3 meters below grade.

This is based on the construction of a residence with a basement excavated to 3 meters.

The soils l

3 removed for the building are graded about the residence and foods arc grown in the excavated soils.

6.

Construction events normally take place at depths less than 3 meters.

7.

When deep disposal is assumed, it is judged less likely that significant construction will take place at these depths (high rise building construction, for example).

For wastes thus disposed, it is assumed that only 10 percent of the wastes are contacted and become available for dispersion into the air and subsequent inhalation by humans.

Further, potential direct gamma exposures from working on homogeneously contaminated ground are assumed to be reduced by a factor equal to one meter of soil shielding (1/1200).

90 With these basic assuaptior.s the allowable Sr concentrations for the stated options were et mputed using the INVERSI code which was also used to determine the limiting radionuclide concentrations for the 10 CFR 61 waste classification system (Reference 3).

The results are provided in Table 1.

Table 1 90 Allowable Sr Concentrations for Unstablized Wastes Allowable Concentration, Allowable Concentration, Construction Scenario, Agricultural Scenario, Option uc/cc uc/cc Unstabilized waste, regular disporal 2.0 0.04 (normal depths)

Unstabilized waste, burial at depths greater than 5 meters 24 NA

  • Agricultural activities are not assumed to take place for wastes disposed at depths greater than 5 meters.

'e

.4 Since the disposal effects for an arid and a humid site are assumed to be the same, the allowable concentrations would be the 5 ace.

However, the 9

above evaluation has considered only the isotope Sr and has not 14 evgguated {gg effects of other limiting long-lived isotopes such as C Tc

, or I which might be present in a waste of this nature.

These isotopes have high migration potentials at humid sites but are generally not specifically measured at power plants due to low concentrations and analytic complexity.

Allowing disposal of higher activity unstabilized wastes at humid disposal sites could result in increased groundwater migration of such limiting long-lived mobile isotopes as well as increased post operational maintenance costs.

Since it is possible that TMI-2 wastes might also contain some of these longer-lived isotopes in concentrations near their Class A limits, it is judged to be prudent to dispose of such higher activity unstabilized wastes at an arid site where it can be assumed that migration is not a significant pathway.

This evaluation, therefore, coneggdes that disposal of unstabilized TMI-2 dewatered resin wastes having Sr concentrations up to 24 ue/cc would be acceptable provided the wastes were buried at depths greate.r than 5 meters at an arid disposal site.

Other isotopes listed in Table 1 of Reference 1, of. course, would need to be accounted for using the concentration ratio factor identified in Table 1.

Evaluation perfor=ed by /

F Date /N-8 /

1, Chec CDate /0 h p/

/

/

p Approved byc

't Date l