ML20032B151

From kanterella
Jump to navigation Jump to search

Responds to Providing Info Re Implementation of Unresolved Safety Issue A-10,BWR Nozzle Cracking.Nrc Concurs W/Util Performing Analysis of Existing Feedwater Low Flow Controller Per Generic Ltr 81-11
ML20032B151
Person / Time
Site: Hatch  
Issue date: 10/20/1981
From: Stolz J
Office of Nuclear Reactor Regulation
To: Beckham J
GEORGIA POWER CO.
References
REF-GTECI-A-10, REF-GTECI-RV, TASK-A-10, TASK-OR GL-81-11, TAC-46706, TAC-46707, NUDOCS 8111040640
Download: ML20032B151 (1)


Text

..

OTOBER 2o DISTRIBUTI0ii:

'iSI C Docket File-2 RJohnson ORB #4 Rdg NRandall NRC PDR DEisenhut L.PDR RK1ecker I

b JStolz FClenenson

.N,

. f 1

/

TERA MFai rtile N[T OELD 5

Dockets flos. 50-321 RIngram -

AEOD JL and 50-3CG RSnaider KKniel RSIO OCTP.2 1981m..8

~ ~

NAnderson Gray File-2.

K ud* % 7

!!r. J. T. Beckham, Jr.

Y Q

" ' ~ ~

b

. _.E g Vice Pmsident - Engineering Georgia Power Corpany P. O. Box 4545 Atlanta, Georgia 30302

Dear !!r. Beckham:

SUBJECT:

IMPLEliENTATION OF UNRESOLVED SAFETY, ISSUE A-10, BUR fiOZZLE CRACKING By letter dated September 1,1981 you provided the infomation requested in our letter dated July 15, 1981 regarding the.above subject at the Edwin I.

Itatch !{uclear Plant, Units 1 and 2..Specifically, you provided:.. (1) infor-mation regarding your plans for plant-specific analysis of the existing feed-water low flow controllers, and.(2) additional infonnation concerning opera-tion of the control rod drive hydraulic system.

We concur in your perfoming the analysis.of the existing feedwater low flo.1 controller as provided by the NRC Generic Letter 81-11 dated February 20, 1981.

We will myiew this analysis when it is submitted in accordance with the guidance of NUREG-0619.

With regard to the control rod drive. hydraulic system modifications, we concur in your assessment that the modifications as described, supplemented by your comitnents regarding testing and in-service inspection, do satisfy the guidance of Section 8.2(2) of NUREG-0619.

No further correspondence is necessary on the subject of A-10 implenentation except your submittal of the analysis discussed above. Should you have any questions, or should problens arise, pl ase do not hesitate to contact your Project flanager.

Sincerely, 80RIGILL 31ggp 37 3 % ?.STOLZs

.. John F. Stolz, Chief Operating Reactors Branch f4 l

Division of Licensing i

cc: See next page 8111040640 811020 PDR ADOCK 05000321

/., t P

PDR j U l

4 0R8#5:DL C 0 B#4:DL AD-

[,,

ORB #w:........ g..

RSnaider J S<tb....... f.

o,,,e,,

TN k

..M.Fa i. ti.e.g.. g p. y -..

3g gf suan m >

unc ronu sia 0o-8o3 nacu om OFFICIAL RECORD COPY usceo: isai-awm