I'/t I[

.DocketNo.$0-206 f

f, 3I

j. Bulletin No.481-02 Southern California $dison Company

$6 klO BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD. CALIFORNI A 91770 J. G. H AYN E S '

October 15,-1981 TEdmoNE

^ AN AGE R CP NUCLE AR OPE R ATIONS E2 3 3),fil 74$ -

M (b

5

'*ff_

' el :

A n

y

- ISLJ

, 4, j

p E.1 -

L 4

L

.e a

g:d OCT2 019818+

E'

~

%g E

w s.,,,cune4Am rxamsw s

\\

~

?[R g,

U. S. Nuclear Regulatory Commission Attention:

R.,H. Engelken, Director Office of Inspection and Enforcement Region V q

Suite 202, Walnut Creek Plaza 1990 North California Boulevard Walnut Creek, California 94596" Gentlemen:

Subject:

Docket No. 50-206 IE Bulletin No. 81-02, Supplement 1

. San Onofre Nuclear Generating Station Unit l' Reference.is made to your correspondencs of August 18, 1981,-

forwarding the subject IE Bulletin Supplement.

Identified therein were inquiries concerning the possible failures of motWoperated valves'to clase.

under design pressure. Specifically, the subject. IE Bulletin Supplement extended the concern to any Westinghouse Electro-Mechanical Division (W-EMD) manufactured motor-operated gate valves larger than the 3-and 4-inch-valves which were the subject of the original IE Bulletin -

You requested that we ascertain whether any W_-EMD manufactured valves have been installed or are maintained as' spares for ins.tallation in safety-related systems, and if so,Everify their aoility to close under the current-and/or intended se.rvice conditions. Based on our review, no W-EMD manufactured motor-operated gate valves, other than those reported in response to the original IE Bulletin dated May 18, 1981, are installed or maintained as spares. for installation at San Onofre Unit -1.

T&Y s

/6

. 8110300156 811015

PDR ADOCK osooo206 '

9 FDR...

.. =

Mr. R. H. Engelken Should you have any questi ns on the above, please contact me.

Subscribed on this

/b day of d

, 1981.

Veiy truly yours, SOUTHERN CALIFORNIA EDIS0N COMPANY

^

(W dh By J. G. Haynes Manager of Nuclear Operations Subscribed and Sworn to b fore me on

..--gg

}

this /SM day of

, 1981 y M AGNES CRABTREE I I

Norm ruouc-caurome i i

omsentomcr m i

i LOS ANGELESCOUNTY My Comnussa Esp. Aug.27,1982{lj

...cw-r- - - _ 7 r- <c :

&W i

NotaryfPublic in and for the County of Lo% Angeles, State of California cc: Director, Office of Inspection and Enforcement

.-. -.