ML20031E366
| ML20031E366 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 10/09/1981 |
| From: | Hollander T PRESRAY CORP. (SUBS. OF PAWLING RUBBER CORP.) |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE) |
| References | |
| REF-PT21-81-499-000 PT21-81-499, PT21-81-499-000, NUDOCS 8110150426 | |
| Download: ML20031E366 (1) | |
Text
(
3 PRESRAY g/ g DAWLING, NE'N YORK 12564 g
g (914) 855-1220
'h
,o,)
04
\\
DJ
~
October 9, 1981
,t 00TI41997 g
Nm%"* h}
Director Office of Inspection and Enforcement
'j/
U.S.
Nuclear Regulatory Core 11ssion N
Wasnington, DC 20555
Subject:
Catawba Nuclear Station Unit 1 Fuel Pool Gates Gentlemen:
It has been determined by us that defective welds on fuel pool gates manufactured by us for Catawba Unit 1 ray be a potentially reportable item under the requirements of Part 21 of title 10, chapter 1, CFR.
Corrective action, replacement of the welded structural items, has been recommended to the purchaser of the gates, Duke Power Company.
Sincerely, PRESRAY
.:Qghu l6 '
'k'fieodore C.
Ioll ander,
P.
Vice President e
TCH:alv cc:
S.B. Hager, Chief Engineer Civil / Environmental Division Duke Power Company THE PRESRAY CORPORATION / suassolARY OF PAWLtNG RUSDER CORPORATIGN 5
iin )
8110150426 011009
- S 1-PDR ADOCK 05000413 i
S PDR/