__
gay 011575 b
Mr. C. Eiche1dinger, Manager Kuclear Safety Department U.stinF ouse Electric Corporation h
P. O. Box 355 Pit t sburgh, Pennsylvania 15230
Dear Mr. Eiche1dinger:
'Ihe NRC staf f has completed it s review of the following Westinghouse Electric Corporation reports:
1.
WCAP-7709-L (Proprietary) and WCAP-7820 (Non-proprietary) entitled.
Electrical Hydrogen Recombiner for kater Reactor Containments '
2.
WCAP-7709-L Suppleeent 1 (Proprietary) and WCAP-7820 Supplement 1 (Non-proprietary) entitled. ' Electric Hydrogen Recombiner for PWR Contaireents,'
3.
WCAF-7709-L Supplement 2 (Proprietary) and WCAP-7820 Supplement 2 (Non proprietary) entitled, " Electric Hydrogen Recombiner for PWR l
l Containments Equipment Qualification Report,"
4.
WCAP-7709-L Supplement 3 (Proprietary) and WCAP-7820 Supplement 3 (Non-proprietary) entitled, " Elect ric Bydrogen Recombiner for PWR Cont ainment s Long Term Tests,
5.
WCAP-7709-L Supplement 4 (Proprietary) and WCAP-7820 Supplement 4 (Non-proprietary) entitled, "R1ectric Hydrogen Recombiner for PWR
(
Con t a inmen t s.
A summary of our evali;.ation is enclosed.
i e
8110140000 811009 PDR ADOCK 05000466 T
pon
3.
US5 br. C. Eicheldinger
-?-
Espott WCAP-7709-L as supplemented, satisfies. the criteria of our
- Elerents of the Regulatory Statt 1opical ReporY Feview Progras' dated August 26, 1974 and thus is considered a topical report. We consider WCAP-7820. as supplemented, an acceptable non-proprietary version of WCAP-7709-L, as supplemented. Whee either of these reports is used as a reference, both the proprietary report and its non-proprietary version sust be referenced.
As a result of our review, we have concluded that WCAP-7709-L, as supplemented, describes en acceptable design and environmental and seismic qualification for the prototype and production models of the West inghouse elect ric hydrogen recombiner.
Therefore, WCAP-7709-L.
as supplemented, nay be referenced in license applications as an accepted topical report when used to support this conclusion. We note, however, that for plant s that are required to perform environ-Pental cualification in accordance with IETE Std. 323-1974, we shall require that the electric hydrogen recombiner also be qualified to this standard.
he do not intend to repeat our review of WCAP-7709-L and its supplements and WCAP-7820 and its supplements when they appear as references in.a particular license application, except to assure that the material presen t ed in these reports is applicable to the specific plant involved.
In accordance w!.th established procedure, we request that within three months of receiving this letter, you issad revised versions of UCAP-7709-L and its suppleednts and WCAP-76:0 and its supplements to include this acceptance letter.
If you have any questions about our evaluation of this report, please contact us.
Sincerely, Original signed by D, B.Vassallo D. D. Vassallo, Chief Light Water Reactors Project Branch 1-1 Division of Reactor Licensing
Enclosures:
Topical Report Evaluation I
e
~,,,.
.,e--.
.---,e-,---
-