gg(
e YANKEE ATOMIC ELECTRIC COMPANY IIbWE, MASSACHUSETTS EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT 1
JANUARY JUNE 1977 8110070022 770630 PDR ADOCK 05000029 R
~
~
YANKEE ATOMIC liLECTI'(C COMPANY, R0WE,' MASS.
EFFLUENT AND WASTE DISI'OSAL QUARTERLY REPORT (1977)
GASEOUS EFFLUENTS - SUMMATION ALL RELEASES TABLE 1A (I
UNIT January Februan March Seconds during Period Secs. 2.16E06 2.42E06 l 3.02E6 l7.60E6 l Fission 6 Activation Gases Tota 1 Re1 ease Ci 5.11E00 3.17E00 6.36E00 1.46E01 Average Release Rate For Per.
pCi/Sc :2. 37E00 1.31E00 2.10E00 1.92E00 1 cati n i 1
,1.69E-01 1.10E-01, 1.63E-01 1.47E-01 l
~
Total Iodine-131 Ci 3.81E-07 1.41E-06 4.22E-07 2.21E-06 Ave. Release Rate for Period uCi/Sc<:1.76E-07 5.83E-07 1.40E-07 2.91E-07 ficatic Li 1
1.21E-02 3.99E-02 9.97E-03 2.02E-02 Particulates Total Gross ( 8. y )
ci i 1.70E-07 1.27E-07 l 3.18E-06 3.48E-06 Particulates h'ith lialf-Lives >R Das s Ci 2.08E-07 8.76E-08 1.91E-07 4.86E-07 Ave. Rc1 case Rate for Period
- pCi/ Sci:9.61E-08 3.62E-08 6.33E-08 6. W nR Percent of Technical Specification Limit i
1.97E-03 1.79E-03 1.94E-03 1.64E-03 Gross Alpha Radioactivity Ci
<1.47E-08 <5.80E-0F 2.69E-09 2.69E-09 l Tritium Total Release Ci 1.36E-01 8.57E-01 5.53E-01 1.55E00 Ave. RcIcase Rate for Period UCi/Sc< 6.30E-02 3.54E-01 1.83E-01 2.04E-01 Percent of Technical 3.09E-03 1.73E-02 9.34E-03 1.02E-02 Specification Limit hhximum Gross Radioactivity Release Rate:
January 7, 1977 (1050) 6.94E02 uc/sec
'Februay 22, 1977 (0945) 2.31E03 uc/sec March 11, 1977 (0710) 8.80E01 uc/sec
- Applies to particulates with half-lives > 8 days.
'*5 2_L$&&
A M 1*hN
' YANKEE ATOMIC ELECTRIC COMPANY, ROWH, MASS. - TABLE IB EFFLUENT AND WASTE DISPOSAL GASEOUS EFFLUENTS
- TOTAL RELEASES (1st) 1977 Nuclides Released Unit January Februnry W rch Quarter l
Fission Gases l
Krpton-85 Ci 6.07E-02 7.42E-03 1.47E-02 8.28E-02 Krpton-8SM Ci 4.11p n9 3.18E-02 6.05E-02 1.33E-01 Ci 2.09E-02 1.81E-02 3.57E-02 7.47F-02 Krpton-87 Krpton-88 Ci 5.26E-02 4.60E-02 8.43E-02 1.83E-01 Xenon-133 Ci 3.70E00 2.18E00 4.75E00 1.06E+01 Xenon-135 Ci 6.31E-01 4.84E-01 7.23E-01 1.84E-00 Aenon-inM L.1 3.44E-01 1.89E-01 3.04E-01 8.37E-01 9.95E-04 3.41E-03 4.24E-03 8.64E-03 Ci Xenon-138 v.u x.-u 4 Others(Specify)X4" Ci 8.80E-02 1.12E-03 1.14E-03 Xenon-133M Ci 6.47E-02 3.74E-02 8.13E-02 1.83E-01 Argon-37 C1 1.88E-02 1.41E-02 3.76E-02
/.05E-02 Argon-41 Ci 5'.54E-02 3.34E-02 8.91E-02 1.78E-01 Carbon-14 Ci 9.29E-04 5.88E-04 2.22E-03 3.74E-03 Rubidium-88 Ci 2.98E-02 1.22E-01 1.72E-01 3.24E-01
'In iden t i fied Ci Total for Period Ci 5.11E00 3.17E00 6.36E00 1.46E01 l
Iodines l
Iodine-131 ci 3.81E-07 1.41E-06 4.22E-07 2.21F.0A Iodine-133 Ci 8.29E-06 3.64E-06 1.10E-05 2.29E-05
~
lodine-135 Ci 9.53E-06 4.16E-06 1.25E-05 2.62E-05 Total for Period Ci 1.82E-05 9.21E-06 2.39E-05 5.13E-05 l
Tritium l Ci l1.36E-01 l 8.57E-01 l 5. 53E-01 l 1.55E00 l
l Particulates I
btrontium-89 l Ci cl.88E-08
<2.11E-08 2.53E-08
<6.52E-08
~.50E-08 1
4.51h-09 5.06E-09 6.07E-09 Strontium-90 Ci Cesium-134 Ci
< 2.7 5E-08
<2.80E-08
- 2.85E-08
< 8.10E 09 rn e s i,m _ i n c;
4.80E-08 8.25E-08 8.71E-08 2.18E-07 Barium-l.anthanium-140 Ci
< 8. 86E-08
<8.29E-08
- 8.55E-08
< 2. 57E-07 Others (Specity)
Ci Cobalt-58 Ci
< 2. 40E-08
<2.60E-08
< 2.65E-08
< 7.65E-08 Cobalt-60 Ci
< 3.14E-08
<3.60E-03
< 4. 34b-08
< 1.11E-07 Iron-59 Ci 1.55E-07
<5.85E-03
< 5. 31E- 08 1.55E-07 Chromium-51 Ci
<1.84E-07
<1.8CE-07
< 1. 92E- 07
< 5.56E-07 Zirconium-Niobium 95 Ci
< 5.16E-08
<3 4VL-U6
< 5. 37E-08
< 1.58E-07 Scienium-75 C1
< 2. 54E-08
< ?. 50E-08
<2.65E-03
< 7.69E-08 Silver-110M Ci
< 3. 97E-08
< 3. 0E-08 4.33E-08 4.33E-08 Antimony-124 Ci
<4.32E-08
<4.25E-08 5.49E-OS
- 5. 4 '.lE- 08 maganese-u ci
- 2.49E-08 42.62E-08
- 2.77b-08
< 7.68E-08 Unidentified Ci
~~
~~
~~
~~
2.08E-07 8.76E-08 1.91E-07 4.86E-07 Tota 1 (or_Pcrind Ci.
~
. ~
(
YANKEE ATOMIC ELECTRIC COMPANY, ROWE, MASS.
EFFLUENT AND WASTE DISPOSAL QUARTERLY REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES TABLE 2A-1st 8
Unit January February March Quarter Fission and activation products Tetal releare (not including tritium, gases, alpha)
C1 8.97E-04 4.73E-04 2.59E-03 3.96E-03 Av ge i u ed concentration 4.25E-11 2.24E-11 9.83E-11 5.78E-11 Ci/m3 4
PIrcent of Applicable Limit t
4.14E-04 2.66E-04 3.56E-03 1.58E-03 Tritium Total Release Ci 1.07E01 3.83E00 3.20E01 4.65E01 Average diluted concentration during period Ci/ml 5.07E-07 1.82E-07 1.21E-06 6.78E-07 Percent of applicable limit 1.69E-02 6.05E-03 4.04E-02 2.26E-02 Dissolved and entrained gases Total Release Ci 3.67E-03 9.57E-04 6.99E-02 7.46E-02 Average diluted concentration during period UCi/ml 1.74E-10 4.54E-11 2.65E-09 1.09E-09 Percent of applicable limit 5.80E-03 1.51E-03 8.83E-02 3.62E-02 Gross Alpha radioactivity l Total Release Ci
<3.36E-08 <2.07E-08 (8.58E-08 <1.40E-07 Alpha Average Concentration uCi/ml< 1.'59E-15 <9.81E-16 c3.25E-15 <2,04E-15 Volume of waste released (prior to dilution)
Liters 1.32E06 1.27E06 2.47E06 5.06E06 Volume of dilution water
_ (used during period) liters 2.11E10 2.11E10 2.64E10 6.86E10 i
Maximum Concentration ( 8,y ) Released To Unrestricted Area
~
Jan. - 17 Jan. 77
@ 1105 - 1.27E-10:uCi/ml i
F%
- O_7 Feb 9 1120 - 7.73E-11 uCi/ml Mar. - 27 Mar 77
/7 9 1650 - 5.08E-10 uct/ml
. ~.
[
I
. i.
YANKEE AlUt:C ELECI'RIC CCNPANY-ROWE, MASS.
EFFWENT AND WASTE DISPOSAL QUARTERLY REPORT 7
TOTAL LIQUID EFFWENTS
[
[ '.,.
f[. ~.
' TABLE 2B t
1977 Nuclides Released Unit January February March Quarter (1) s Strontium-89 Ci
< 1.02E-05
<5.80E-06
<2. 62E-o t;
< d 7?F-nt; Strontium-90 Ci
< 8.16E-07
<4.1QF-07
<2.02E-06
< 3.26E-06 r ii n-1 u r;
3.10E-06 1.13E-06 3.76E-05 4.18E-05 Cesium-137 Ci 4.57E-06 2.50E-06 7.94E-05 R 6t;F-09 Iodine-131 Ci 4.83E-06 2.97E-06 2.13E-04 2.21E-04 Cobalt-58 Ci 3.29E-07 8.09E-08 1.14E-07 5.24E-07 Cobalt-60 Ci 6.14E-07 8.95E-07 5.05E-06 6.56E-06 Iron-59 Ci 3.14E-07
< 3. 00E-07 3.71E-07 6.85E-07 Zinc-65 Ci
< 8. 32E-07 3.07E-07 2.26E-07 5.33E-07 ri.
5.68E-08 7.61E-08 1.08E-07 2.41E-07 Manenne<:e-54 Chromium-51 Ci 6.57E-07 1.02E-06 3.87E-06 5.55E-06 Zirconium-Niobium-95 Ci
< 8. 88E-07 2.00E-07 5.99E-06 6.19E-06 Molybdenum-99 Ci 3.81E-07 2.18E-06
<1.03E-05 2.56E-06 Technetinm-99M Ci 1.09E-08
<1.26E-07 1.16E-07 1.27E-07 Barium-Lanthanum-140 Ci
<1.17E-06
< 7. 36E-07
<6.44E-06
<8.35E-06 Cerium-141 Ci
<5.53E-07
< 2.1 ?E-07 3.17E-07 3.17E-07 Other(Specify)
Ci Iodine-133 Ci
< 7. 87E-07 4.74E-07
- 6. 34F-06 6.81E-06 Scieniin-75 Ci
< 6. 21E-07
< 2. 57E-07
<2.54E-06
<3.42E-06 Silver-110'1 Ci 5.74E-08 6.20E-07 3.90E-07 1.07E-06 Antimony-124 Ci 2.31E-08 2.81E-08
<1.81E-06 5.1?F-OR Carbon-14 Ci 8.76E-04 4.56E-04 2 22E-03 3.55E-03 Ceritzn-144 Ci
< 2.13E-06
< R. 96E- 07 1.41E-06 1.41E-06 Unidentified Ci 6.24E-06 4.15E-06 1.95E-05 '
2.99E-05 Total for Period (above) Ci 8.97E-04 4.73E-04 2.59E-03 3.96E-03 Xenon-133 Ci 3.66E-03 9.49E-04 6.97E-02 7.43E-02 Xenon-135 Ci 1.28E-05 8.44E-06 2.66E-04 2.87E-04 Trititun Ci 1.07E01 3.83E00 3.20E01 4.65E01
_______________nn__
YAN1GE ATO4IC ElIERIC COMPANY-ROWE, MASS.
~
[
SOLID WASTE SHIPMENT HEPORT 1977 Evaporator Bottoms January Febmary March Quarter (1) ft.3 1.76E02 1.76E02 Ci 5.87E-02 5.87E-02 1977 Dry Compressible Waste January February March Quarter (1) ft.3 3.36E02 3.36E02 Ci 1.00E-05 1.00E-05 Decontamination' Soln.
Quarter ( )
ft.3 Ci Other:
Quarter ( )
ft.3 Ci Solid Waste Disposition
_No. of Shipments Dates Trans. Mode Destination 1
12 Jan. 1977 Tmck Barnvell, S. C.
I
\\
' a. e 1r eys
-w
,ea
~
YANKEE ATOMIC liLECTI 8C COMPANY, R0Wii, NASS.
EFFLUENT AND WASTE DISL OSAL QUARTERLY REPORT (1977)-
GASEOUS EFFLUENTS - SUMMATION ALL RELEASES TABLE 1A UNIT April May June QUARTER Seconds during Period Secs.
2.42E06 3.02E06 l2.42E06l7.86E06 l Fission f. Activation Gases Total Release Ci 2.41E00 4.59E00 1.69E01 2.39E01 Average Release Rate For Per. pCi/Sc.: 9.95E-01 1.52E00 6.99E00 3.04E00 Percent of Technical Specification Limit t
9.05E-02 1.47E-01 1.59E-01 1.38E-01 Iodines Total lodine-131 Ci
<8.95E-0j6.88E-07 2.53E-05 2.60E-05 Ave. Release Rate for Period uCi/Sec< 3. 70E-07 2.28E-07 1.04E-05 3.31E-06 Percent of Tecitnical Specification Limit 1
<2.55E-02 1.64E-02 4.37E-01 1.92E-01 Particulates Total gross f8.Y )
ci 1.26E-Of 3.09E-07 3.93E-06 5.506-00 Particulates With lialf-Lives >R Das s Ci 1.15E-07 6.76E-08 1.37F-07 T 19F-07 Ave. Release Rate for Period uCi/Sec4.77E-08 2.24E-08 5.46E-08 4.01E-08 Percent of Technical Specification Limit 1
2.17E-03 1.42E-03 3.50E-03 2.50E-03 Gross Alpha Radioactivity Ci l 2.66E-09 <5.37E-03 1.82E-08 2.09E-08 Trititrn j
' Total Release I Ci 5.49E-02 5.21E-02 1.07E-01 2.14E-01 Ave. Release Rate for Period UCi/Sec 2.27E-02 1.72E-02 4.42E-02 2.72E-02 Parcent of Tecimical Specification Limit Ci 1.12E-03 8.86E-04
- 1. 32E-03 1.13E-03 Maximum Gross Radioactivity Release Rate:
April 27, 1977 (1030) - 9.21E02 uCi/sec May 23,1977 (1030) -
3.82E02 uCi/sec June 14,1977 (1400) -
1.51E03 uCi/sec l
I l
Applies to particulates-with half-lives > 8 days.-
M'
- g w'
~
T
' YANKEE ATOMIC ELECTRIC COMPANY, R0hli, MASS.
TABLE IB EFFLUENT AND WASTE DISPOSAL GASEOUS EFFLUENTS
- IUTAL RELEASE 1977 Nuclides Released Unit APRIL MAY JINE Ouarterr?)
[
Fission Gases l
Krpton-85 Ci 1.01E-01 6.83E-03 9.21E-01 1.03E00 Krpton-85M Ci 3.27E-02 5.03E-02 2.61E-02 1.09E-01 Krpton-87 Ci 2.07E-02 3.02E-02 4.42E-02 9.51E-02 Krpton-88 Ci 5.00E-02 6.92E-02 2.16E-02 1.41E-01 Xenon-133 Ci 1.36E00 3.02E00 1.43E+01 1.87E+01 Xenon-135 Ci 4.00E-01 6.78E-01 3.28E-01 1.41E00 Aenon-i m L1 1.21E-01 3:29E-01 9.40E-02 5.44E-01 Xenon-138 Ci 4.02E-03 1.55E-02 4.43E-03 2.40E-02 Others(Specifvfel31M Ci 4.34E-02 2.78E-02 4.92E-02 1.20E-01 Xenon-133M Ci 1.69E-02 4.24E-02 4.75E-02 1.07E-01 Argon-37 Ci t otp-n?
7 07F-n?
7_R9F-01 R 9dF-01 Argon-41 Ci 8'. 26E-02 8.48E-02 4.73E-02 2.15E-01 Carbon-14 Ci
- 4. 29E-02 1.12E-03 1.84E-01 2.28E-01 Rubidium-88 Ci 9.25E-02 2.08E-01 5.94E-02 3.60E-01 Unidentified Ci Total for Period Ci 2.41F00 4.59E00 1.69E01 2.39E01 lodines l
ci
< 8.95E-07 6.88E-07 2.53E-05 2.60E-05 Iodine-131 lodine-133 Ci
< 7. 56E-06
< 8. 57E-06
< 7.09E-06
< 2. 32E-05 Iodine-135 Ci
< 7.18E-06
< 9.94E-06 e6.88E-06
< 2. 40E-05 Total for Period Ci
< 1.56E-05 6.88E-07 2.53E-05 2.60E-05 Tritium l Ci l 5.49E-02 l5.21E-02 l 1.07E-01 l2.14E-01 l
l Particulates l
l j
atrontium-89 Ci
<3.74E-08
<4.47E-08
<6.16E-08
<1.44E-07 i
Strontium-90 Ci
<5.61E-08
<6.70E-08
<9.23E-08
<t12F-07 Cesium-134 Ci
< 2.79E-08
< 1. 84E-08
< 8.05E-08
< 1. 27E-07 coc iivm-1 T 7 ri 7.53E-08 6.76E-08
< 8. 55E-08 1.43E-07 Barium-Lanthanium-140 Ci
< 8.95E-08
< 5. 84E-08
< 2. 48E-0 7
< 3.96 E-07 Others (Specify)
Ci Cobalt-58 Ci
< 2. 61E- 03
< 1. 71E-08
< 7.10E-08
< 1.14E-07 Cobalt-60 Ci
< 3.11E-08
< 2. 50E-08
< 1.19E-0 7
< 1. 75E-07 Iron-59 Ci
< 5. 52E-08
< 3. 70E-08
< 1. 40E-07
< 2. 32E-07 Chromium-51 Ci
< 1. 90E-07
< 1. 28E-07
< 4.85E-07
< 8.0 3E-07 Zirconium-Niobium 95 Ci eq zap.ng et onn-ng
-1 con-n,
<, son nv Scienium-75 Ci
< 2. 70E-08
< 1. 73E-08
< 7.19E-08
<1.16E-07 Silver-110M Ci 4.02E-08
<2.80E-08 1.32E-07 1.72E-07 Antimony-124 Ci
< 3. 99E-08
< 2. 74E-08
<1.42E-07
< 2. 09E-07 C1 Manennese-;a
< 2. 53E-08
< 1. 8 3E-08
<7.60E-08 1.20E-07 Unidentified Ci Total for Period Ci 1.15E- 07 6.76E-08 1.32E-07 3.15E-07
YANKEE ATOMIC ELECTRIC COMPANY, ROWE, MASS.
EFFLUENT AND WASTE DISPOSAL QUhRTERLY REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES TABLE 2A Quberf2:
l Unit April May June
- ission and activation products retal release (not including tritium, gases., alpha)
Ci 2.82E-03 3.17E-03 1.82E-03 7.81E-03 Average diluted concentration during period pCi/m1 1.25E-10 1.40E-10 3.87E-10 1.56E-10 Percent of Applicable Limit 1.80E-03 4.47E-03 8.56E-03 3.64E-03 Tritium Total Release Ci 2.62E01 2.29E01 5.81E00 5.49E01 Average diluted concentration 1.16E-06 1.01E-06 1.23E-0(
1.10E-06 during period pCi/ml Percent of applicable limit 3.87E-02 3.36E-02 4.10E-0:
3.67E-02 Dissolved and entrained gases Total Release Ci 6.43E-02 1.67E-01
- 1. 58 E- 0.' 2.33E-01
(
Average diluted concentration l
during period UCi/m1 2.84E-09 7.39E-09 3.35E-10 4.67E-09 l
Parcent of applicable limit 9.47E-02 2.46E-01 1.12E-02 1.56E-01 Gross Alpha radioactivity l
Total Release Ci
<8.15E-0E <8.84E-08 <5.22E-08 <2.22E-07 Alpha Average Concentration uCi/ml <3.61E-15<3.91E-15 <1.11E-14 <4.45E-15 Volume of waste released (prior to dilution)
Liters 1.85E06 1.90E06 1.29E06 5.04E06 l
Volume of dilution water (used during period) liters 2.26E10 2.26E10 4.71E09 4.99E10 i
Maximum Concentration ( 8,y ) Released To Unrestricted Area April - 05 April 77 0 1520 - 3.13E-10 uCi/ml May - 13 May 77 e 1455 - 6.49E-10 uCi/ml June - 20 June 77 0 1920 - 9.6!in-9 uCi/ml
\\
m
YANKEE A10ilC ELECIRIC CCNPANY-ROWE, MASS.
EFFWENT AND WAbTE DISPOSAL QUARTERLY REFORT TOTAL LIQUID EFFLUENTS TABLE 2B 1977 Nuclides Released Unit April May June Quarter (2)
Strontitsn-89 Ci
<4.85E-05
<5.36E-05
<3.64E-05
<1.38E-04 Strontium-90 Ci
<9.57E-06
<1.04E-05
<6.34E-06
<7 6tF-05 ex iiiiii-i u r;
3.92E-05 2.89E-05
_1.97E-05 8.78E-05 Cesium-137 Ci 7.32E-05 3 1-0 C 2.55E-05 1.32E-04
_ lodine-131 Ci 9.04E-05 2.74E-04 1.01E-04 4.65E-04 Cobalt-58 Ci 7.08E-07 6.76E-07 6.72E-07 2.06E-06 i
Cobalt-60 Ci 2.13E-05 1.39E-05
?.50E-06 3.77E-05 Iron-59 Ci 3.69E-07 5.12E-07 1.05E-06 1.93E-06 2inc-65 Ci 1.07E-06 2.50E-07 6.10E-07 1.93E-06 Ubnnnnese-54 ci 6.73E-08 1.76E-06 4.84E-07 2.31E-06 Chromium-51 Ci 3.49E-06 1.21E-06 1,81p-06 6.91F-06 Zirconium-Niobium-95 Ci 1.56E-06 7.98E-06 4.11E-06 1.36E-05 Molybdenum-99 Ci
< 8.75E-06 1.41F-06 9.86E-07 2.40E-06 Technetium-99M Ci
< 9. 09E-07
<9.64E-07
<7.07E-07
<?.GRF-06 Barium-Lanthanum-140 Ci
< 5. ?RF-06
<a.7TF-07
<(R1F-06
<9.51E-06 i
Cerium-141 Ci 2.61E-07 1.98E-08 1.08E-06 1.36E-06 Other(Specify)
Ci l
Iodine-133 Ci 3.39E-06 2.68E-07 4.55E-07 4.11E-06 Scienium-75 Ci 2.26E-07
<1.82E-06
<1.35E-06 2.26E-07 Silver-110M Ci 1.16E-06 6.44E-07 4.72E-07 2.2RF-06 Antimony-124 Ci 1.80E-07 2.16E-08
<1.25E-06 2.02E-07 Carbon-14 Ci 2.58E-03 2.80E-03 1.66E-03 7.04E-03 Cerium-144 Ci 5.63E-07 9.28E-07 1.08E-06 2.57E-06 Unidentified Ci
<4.07E-06
<3.40E-06
<2.68E-06
<1.01E-05 Total for Period (above) Ci 2.82E-03 3.17E-03 1.82E-03 7.81E-03 Xenon-133 Ci 6.42E-02 1.67E-01 1.57E-03 2.33E-01 Xenon-135 Ci 7.18E-05 3.77E-05 8.15E-06 1.18E-04 Tritium Ci 2.62E01
'2.29E01 5.81EC0 5.49E01
-w,am--we,ww.
w,-,--..e*r:--c.,1
,,,.-e-,
,.,-wc.mw,w..-.--,=,w--__---w,--w-m,
---s e
=--
7__
~
]
YANKEE KlUilC ELECrillC COS'ANY-10WE, MASS.
>l SOLID WASTE SillIMNT REPORT 1977 Evaporator Bottoms April May June Quarter (2) ft.3 None None 4.63E02 4.63E02 Ci 5.10E-01 5.10E-01 Dry Conpressible Naste April May
' June Quarter (2) ft.3 None None 1.28E02 1.28E02 Ci 6.9E-03 6.9E-03 Decontamination Soln.
April May June Quarter (2)
~
ft.
None Ci Quarter (2)
Other:
April May June ft.3 None Ci Solid Waste Disposition
_No. of Ship:nents Dates
'frans. Mode Destination 1
June 10 Truck Barnwell, S. C.
l 4
e e
---rw
+~rvw=e-w - - - -
,,,v+
-***'+*r-
'- =*