ML20030C200

From kanterella
Jump to navigation Jump to search
Advises That Details Re 800602 RO Concerning Concentrated Boric Acid Storage Tank Pump Inadvertently Removed from Svc Will Be Submitted No Later than 800711
ML20030C200
Person / Time
Site: Oconee 
Issue date: 06/26/1980
From: Parker W
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8108250510
Download: ML20030C200 (1)


Text

Op;,.y'M1. c p oE DUKE POWER COMPANY PowEn BUILDINJJSNRC P.EG ' '

422 Socru CnUncu Crazzi,CnInbrh

.b.iaa42 June 26, 1980'3 JV[ g Pl: 3b muaw o. s>4a ara. sa.

~

TELEp*cNE. Anta 7c4 Vict Pats 3ct%v Svtau Paconvios.

3?3-4;63 iiD!, /

.j.

g Mr. James P. O'Reilly, Director d

g g, (.h y.

U. S. Nuclear Regulatory Commission f8 Region II 101 Marietta Street, Suite 3100 1-ejJ[o

/,

D

[Q*

f Atlanta, Georgia 30303

,.~g l}/

(

Re: Oconee Unit 1 Docket Na ~

9 Daar Mr. O'Reilly:

On June 2, 1980 your office was informed that a concentrated boric acid storage tank (CBAST) pump was removed from service for preventive maintenance, which constitutes operation in a degraded mode.. Reportable Occurrence Report RO-269/80-17, providing details of the incident, was to have been submitted by June 27, 1980. However, investigation of the incident is not complete.

It is anticipated that the report will be submitted no later than July 11, 1980.

.1 Ver, truly yours,

/

' A$e u ([. /ztc h

/ William O. Parker, Jr.

FTP:ses

-rE-w n108250510 800626 PDR ADOCK 05000269

,.' 3.').

- PY p.oR o

,-