Forwards IE Bulletin 81-02,Suppl 1, Failure of Gate Type Valves to Close Against Differential Pressure. Written Response Required
ML20030C067
Person / Time
Site: Humboldt Bay, San Onofre
Issue date: 08/18/1981
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Papay L
SOUTHERN CALIFORNIA EDISON CO.
Shared Package
ML20030C047 List:
References
NUDOCS 8108250363
Download: ML20030C067 (1)


Text

pe cuc

'o UNITED STATES

[ )*m },

NUCLEAR REGULATORY COMMISSION

r REGION V k

'[

1990 N. CALIFORNIA BOULEVARD d'

SUITE 202. WALNUT CREEK PLAZA e,,,e WALNUT CREEK, CALIFORNIA 94596 August 18, 1981 Docket Nos. 50-361, 50-362 Southern California Edison Company P. O. Box 800 2244 Walnut Grove Avenue Rosemead, California 91770 Attention:

Dr. L. T. Papay, Vice President Advanced Engineering Gentlemen:

The enclosed bulletin supplement is forwarded for action. A written response is required.

To assist NRC in evaluating the value/ impact of each bulletin and supplement on licensees, it would be helpful if you would provide an estimate of the manpower expended in the review and preparation of the report (s) required by the bulletin supplement.

Please estimate separately the manpower associated with corrective actions necessary following identification of problems through the bulletin supplement.

If you need additional information regarding this matter, please contact this office.

Sincerely, CO~

A R. H. Engelken Director

Enclosures:

1.

IE Bulletin No. 81-02, Supplement 1 2.

List of Recently Issued IE Bulletins cc w/ enclosures:

R. Dietch, SCE i

8108250363 810828 PDR ADOCK 05000133 PDR I

1 SSIN No. 6820 Accession No.:

S 11

  • 028 1-IEB 81-02, Supp. 1 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 18, 1981 IE BULLETIN N0. 81-02 SUPPLEMENT: FAILURE OF GATE TYPE VALVES TO CLOSE AGAINST DIFFERENTIAL PRESSURE Description of Circumstances:

IE Bulletin No. 81-02, " Failure of Gate Type Valves to Close Against Differential Pressure," identified several gate type valves that had been shown by tests and/or analyses by Westinghouse to have a potential for not closing against differential pressure.

As a part of its ongoing analysis program, Westinghouse Electro-Mechanical Division Q-EMD) has applied the analytical methods developed for valves discussed in IE Bulletin 81-02 to the remaining motor operated gate valves that they manufacture.

These analyses predict that closure problems could i

Liso be anticipated with 6, 8, 10, 12, 14, 16, and 18-inch nominal size valves in addition to 3-and 4-inch low-pressure valves.

Thus, the entire line of 4

W-EMD manufactured motor-operated gate valves has the potential for not closing against differential pressure.

l i

Westinghouse has indicated to NRC that they have notified all of their domestic nuclear customers of this problem. When the valves were provided as original j

scope of supply, they also identified the recommended corrective action necessary to assure valve closure under the system service conditions that their records show the valves will experience. Where the valves were provided as spares or replacements, they indicated the threshold differential pressure across the valves above which closure could not be assured under the utility order equip-ment specification conditions, e list of power reactor facilities that Westinghouse believes to have the potentially affected valves is given in Table 1.

However, this list, as well as Westinghouse's notifications, does not take into consideration the fact that the valves may have been transferred between facilities.

In addition, the Westinghouse detenninations of operability and corrective action do not take into consideration the fact that the valves may have been transferred between systems or that the system service conditions may have changed through design evolution.

It is therefore essential that all facilities verify the presence or absence of W-EMD manufactured motor-operated gate valves and also verify their ability to close under the current and/or intended service conditions.

Actions To Be Taken by Licensees:

1.

Within 30 days of the issuance date of this bulletin supplement, ascertain whether any }l-EMD manufactured motor-operated gate valves have been 1

IEB 81-02. Supp. 1 August 18, 1981 Page 2 of 4 installed, or are maintained as spares for installation, in safety-related systems where they are required to close against a differential pressure.

2.

If no valves, other than those reported in response to IE Bulletin 81-02, are identified, report this to be the case. No further action is required.

3.

If any valves are identified as being installed, verify that they are capable of closing under their current limiting normal and post accident service conditions.

If such cannot be shown, take corrective action on these affected valves and evaluate the effect that failure to close under any condition requiring closure would have on system (s) operability pursuant to the facility technical specifications for continued operation.

4.

If any valves are identified as spares, verify that ti:ey are capable of closing under their intended limiting nomal and post accident service condi tions.

If such cannot be shown, either modify the affected valves so that they are qualified for the intended service or obtain qualified replacements prior to installation.

5.

Within 45 days of the issuance date of this bulletin supplement, submit a report to NRC listing the affected valves identified in safety-related systems, their service or planned service, and the maximum differential pressure at which they would be required to close, the safety consequences of the valves failing to close, the corrective action taken or planned, and the schedule for completing the corrective action.

Actions To Be Taken by Construction Permit Holders:

1.

Ascertain whether any W-EMD manufactured motor-operated gates valves are or will be installed, or maintained as spares for installation, in safety-related systems where they are required to close against a differential pressure.

2.

If no valves, other than those reported in response to IE Bulletin 81-02, are identified, report this to be the case.

No further action is required.

3.

If any valves are identified, verify that they are capable of closing under their intended limiting normal and post accident service conditions.

If such cannot be shown, either modify the affected valves so that they are qualified for the intended service or obtain qualified replacements prior to startup.

4.

Within 90 days of the issuance date of this bulletin supplement, submit a report to NRC listing the affected valves identified for use in safety-related systems, their planned service, the maximum differential pressure at which they would be required to close, the safety consequences of the valves failing to close, the corrective action taken or planned, and the schedule for nmpleting the corrective action.

For those cases in K

'h reports have already been submitted in accordance with the Technical Specific.

Sn,10 CFR Parts 21 and/or 50.55(e), this infomation need not be resubmitted.

Rather, licensees or construction permit holders should reference this ear '" report and submit only the additional infomation requested above.

.i 1

IEB 81-02, Supp. 1 August 18, 1981 4

Page 3 of 4 l

}

Reports, signed under oath or affirmation under the provisions of Section 182a 3

of the Atomic Energy Act of 1954, shall be submitted to the Director of the appropriate NRC Regional Office and a copy shall be forwarded to the Director j

of the NRC Office of Inspection and Enforcement Washington, D.C.

20555.

1 If you need additional information regarding this matter, please contact the

{

appropriate NRC Regional Office.

This request for information was approved by OMB under blanket clearance number 3150-0012 that expires December 31, 1981.

4 Comments on burden and duplication should be directed to the Office of Management l

and Budget, Reports Management Room 3208, New Executive Office Building, Washington, D.C.

20503.

i Attachments:

1.

Table 1, Partial List of Plants With Valves Manufactured by W-EMD 4

2.

Recently issued IE BulletTns 4

t 1

l i

l i

IEB 81-02, Supp. 1 August 18, 1981 TABLE 1.

PARTIAL LIST OF PLANTS WITH VALVES MANUFACTURED BY }i-EMD Valves Supplied as Valves Supplied as Spares or Replacements Original Scope of Supply Arkansas Nuclear One 1 Beaver Valley 2 Beaver Valley 1 Braidwood 1, 2 Callaway 1, 2 Byron 1, 2 Catawba 1, 2 Callaway 1, 2 Diablo Canyon Comanche Peak 1, 2 Farley Shearon Harris 1, 2, 3 Indian Point 2 Marble Hill 1, 2 Midland 1, 2 Seabrook 1, 2 Oyster Creek South Texas 1, 2 Prairie Island 1, 2 Summer 1 St. Lucie 2 Vogtle 1, 2 San Onofre 1, 2, 3 Watts Bar 1, 2 Summer 1 Wolf Creek 1 Surry 2 Wolf Creek 1

IEB 81-02, Supp. 1 August 18, 1981 RECENTLY ISSUED IE BULLETINS

~

Bulletin No.

Subject Date Issued Issued'To 81-03 Flow Blockage of Cooling 4/10/81 All nuclear power Water to Safety System facilities with Components by Corbicula an OL or CP Sp. (Asiatic Clam) and Mytilus Sp. (Mussel)

_v 81-02 Failure of Gate Type Valves 3/9/81 All power reacLir to Close Against Differential facilities with an Pressure OL or CP 81-01 Surveillance of Mechanical 3/5/81 All power reactor Rev. 1 Snubbers facilities with an OL & specified facilities with CP j

80-17, Failure of Contrei Rods 2/13/81 All BWR facilities Supplement 5 to Insert During a Scram with OL or CP i

81-01 Surveillance of 1/27/81 All power reactor Mechanical Snubbers facilities with OL

& to specified facilities with CP 80-25 Operating Problems with 12/19/80 All BWR facilities Target Rock Safety-Relief with OL & specified l

Valves at BWRs near-term OL BWR facilities & all BWRs with a CP Supplement 4 Failure of Control Rods 12/18/80 To specified BWRs to 80-17 to Insert During a Scram with an OL & All at a BWR BWRs with a CP 80-24 Prevention of Damage 11/21/80 All power reactor Due to Water Leakage facilities with Inside Containment OL or CP (October 17, 1980 Indian Point 2 Event) 80-23 Failures of Solenoid 11/14/80 All power reactor Valve: Manufactured by facilities with Valcor Engineering OL or CP Corporation OL = Operating License CP = Construction Permit

,.-