TSI -032 CONTAINMENT SYSTEMS

, i.

BRVEILLAEElE@lREEt415 -

4.6.1.3 Each containment air lock shall be demonstrated OPERABLE:

a.

Within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> following each closing, except when the air lock is being used for multiple entries, then at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, by verifying seal leakage is less than 0.01 L as determined by precision a

flow measurements when measured for at least 30 seconds with the volume between the seals at a constant pressure of 37.5 psig; b.

By conducting overall air lock leakage tests at not less than P '

a 37.5 psig, and verifying the overall air lock leakage rate is within-its limit:

1)

At least once per 6 months,* and 2)

Prior to establishing CONTAINMENT INTEGRITY when maintenance has been performed on the air lock that could affect the air lock sealing capability.**

c.

At least once per 6 months by verifying that only one door in each air lock can be opened at a time, d.

By verifying at least once per 7 days that the instrument air pres-sure in the header to the personnel airlock seals is > 90 psig.

e.

By verifying the door seal pneumatic system OPERABLE at least.once per 18 months by conducting a seal pneumatic system leak test and verifying 41st system -prc :ure doc: not dcccy more than 1.5 psi frem 90 prig 4 ir "ithin 21 heur:.

od. of thE Youcultt4G !

13 ThAT s,(ste m PResseat. Does Nor occAT rqone fling- /,S Psi-4 0 0 t1 90 iMG rh tci n u n w M d. M bo0R5 O R.

3 M ThrsT

$45wn PRessuke. Dots Nur Dec AY MoRe.14/w,M Psi bn 90 esiG nenen 4 0 o. 8 hoeas.

  • The provisions of Specification 4.0.2 are not applicable.
    • This represents an exemption to Appendix J, paragraph III.D.2 of 10 CFR Part 50.

SOUTH TEXAS - UNITS 1 & 2 3/4 6-6

.