SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION t
RELATED TO AMENDMENT NO.
47 TO FACILITY OPERATING LICENSE NO. NPF-62 f
ILLINDIS P_0WER COMPANY, ET AL.
CLINTON POWER STATION, UNIT NO. 1 DOCKET NO. 50-461
1.0 INTRODUCTION
By letter dated February 5,1988 Illinois Power Company, et al., (the licensee) requested several changes to the Technical Specifications for the Clinton Power Station.
Package number 5 of that submittal requested a change that would remove the isolation requirement for the Containment Monitoring (CM) ano Process Sampling (PS) systems upon a Containment Exhaust Duct High Rad s',gnal from Section 3.4.3-2, the Containment and Reactor Vessel Isolation Control System (CRVICS).
The proposed change would also revise the list of containment isola-tion valves in Section 3.6.4 to delete the Containment Exhaust Luct High Rad trip from the list of isolation signals for the affected CM and PS valves.
2.0 EVALUATION Clinton Technical Specifications (TS Tables 3.3.2-1, 3.3.2-2, 3.3.2-3, and 4.3.2-1) list the operability requirements, the setpoints, the response times, and the surveillance requirements for the Containment and Reactor Vessel Isolation Control System channels.
Item 1.h in the aforementioned tables is the Containment Building Exhaust Radiation - High trip and includes as sub-systems:
i 1)
Containment Bldg. HVAC (VR) and Drywell Purge (VQ) 2)
ContainmentMonitoring(CM)andProcessSampling(PS)
Currently the TS regulre that the CM and PS systems automatically isolate upon receiving a Containment Building Exhaust High Radiation signal.
However, the CM and PS systems are designed to be operable at high radiction levels.
The Hydrogen and Oxygen monitoring function of the CM system and the Post Accident Sampling System function of the PS system are functions normally used during post-accident conditions.
The Cli and PS systems have small diameter (3/4-inch) lines, are normally closed loops and, therefore, are unlikely to have their integrity challenged by a condition which generates high containment radiation without associated increases in pressure and/or temperature.
The isolation l
of the CM and PS valves initiated by high pressure and/or temperature would be unaffected by this change. The only isolation proposed to be deleted is the Containment Building Exhaust High Radiation signal. The required isolation i
on a Loss of Coolant Accident (LOCA) signal is unaffected by this change. The l
proposed change to the CRVICS tables, deleting the CM and PS isolation require-ment upon a Containment Building Exhaust Radiation - High signal, is consistent with containment isolation requirements and, therefore, is acceptable.
1 l
9010040260 900925 l-PDR ADOCK 05000461 P
PNV l
j I
2 i
o i
The proposed change to delete the reference in Table 3.6.4-1 to the Containment i
Building Exhaust Radiation - High signal as a trip for the affected CM and PS valves is necessary to remain consistent with the previous change and is, therefore, acceptable. The administrative change to delete.the specific reference to the VR and VQ systems as subsystems under Containment Building Exhaust Radiation - High in Tables 3. 3. 2-1, 3. 3. 2-2, 3.1. 2-3, and 4. 3. 2-1 i s acceptable since no other subsystems will now have indieidual requirements
}
under that trip and the appropriate valves are still listed in Table 3.6.4-1,
3.0 ENVIRONMENTAL CONSIDERATION
Pursuant to 10 CFR 51.21, 51.32, and 51.35, an environmental assessment and i
finding of no significant impact has been prepared and published in the Federal i
Register on August 14,1990 (55 FR 33192).
Accordingly, based upon the environmental assessment, the Commission has determined that the issuance of this amendment will not have a significant effect on the quality of the human i
environment.
4.0 CONCLUSION
The staff has concluded, based on the considerations discussed above, that:
(1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner; and (2) such activities will be conducted in compliance with the Commission's regulations and the issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public.
Principal Contributor:
[
Dated: September 25, 1990' i
. - -