ML20028F038
| ML20028F038 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 01/21/1983 |
| From: | Snyder B Office of Nuclear Reactor Regulation |
| To: | Kanga B GENERAL PUBLIC UTILITIES CORP. |
| References | |
| NUDOCS 8301280499 | |
| Download: ML20028F038 (3) | |
Text
.
g' Distribution:
g DocketJNeKSC320a NRC PDR January 21, 1983 Local POR DCS TMI HQ R/F TMI Site R/F BJSnyder.
Docket No. 50-320 LBarrett TPoindexter MMasnik RWeller RBellamy (TMI Site)
AF6sano (TMI Site)
JWeibe (TMI Site)
LChandler, ELD Mr. B. K. Kanga. Director ACRS (16)
Three Mile Island Unit 2 HRDenton GPU Nuclear Corporation I&E (3)
P.O. Box 480 Route 441 South Middletown, PA 17057
Dear Mr. Kanga:
SUBJECT:
GENERAL PROJECT DESIGN CRITERIA, REVISIONS 2 AND 3
REFERENCE:
GPU letter from Kanga to Barrett. 4410-82-L-0046, dated November 11, 1982 We have reviewed your Revisions 2 and 3 of the General Project Design Criteria (GPDC) as forwarded in the referenced letter. These comments-should be resolved before Revision 3 is made effective.
Sincerely,
/s/
Bernard J. Snyder, Program Director Three Mile Island Program Office Office of Nuclear Reactor Regulation
Enclosures:
NRC Comments on General Design Criteria, Rei. 2&3 cc:
J. Barton L. King J. Byrne Service List (see attached) 8301200499 830121 PDR ADOCK 05000320 P
PDR TMI 0; R TMIP0:NRR TMIP0:NRR c........
OFFICE )
M......s..j..i.y.d....t..e..r.;..b.H...R..AW..e l..l..e..r
..B..J..S..n.X.d..e..r.......
ty sunuma>
..1.E.f.l!.3...........ll8R#3.....
..ll....laa........
om)
OFFIClAL. RECORD COPY usaro: mi_m.m une ronu sia cio ao) nacu o24o
4 NRC COMMENTS ON GENERAL PROJECT DESIGN CRITERIA REVISIONS 2 and 3 Section Comment 2.5 Safety-related should not be limited to permanent plant features. The Mini-Decay Heat Removal System has operability requirements in the Proposed Tech Specs and should be it.terpreted as being safety related. Also,
future systems may be installed that are not permanent but are safety related. Delete the word permanent.
2.6 Items that assure the integrity of the reactor coolant pressure boundary but are not required to maintain the plant in a safe shutdown condition should be item "d."
Examples would be the Standby Pressure Control System and SDS when in the RCS processing mode.
3.2.7 It was agreed per your Documentation of Verbal Communication Form dated August 31,1982 (Byrne to Lynch) that words should be added to this section stating that the river flow rate for assessing actual releases from TMI-2 should be obtained exclusively from the USGS gaging station at Harrisburg, PA.
This requirement should be added as paragraph 3.2.8.
3.4.1 (L)
The Appendix R criteria should be retained.
Exemption has not to date been granted and even when approved, it will apply only to certain requirements of Appendix R.
Table 1 Item 3 Justify the deletion of. Reg. Guide 1.26 (Quality Group Classifications).
Item 4 Justify the deletion of Reg. Guide 1.29 (Seismic Design Classification).
Item 7 Justify the deletion of Reg. Guide 1.63 (Electrical Pene-tration Assemblies in Containment.....).
Item 10 Justify the deletion of Reg. Guida 1.111 (Methods for Estimating Atmospheric Transport and Dispersion of Gaseour Ef fl uents...... ).
l
J RONALD C. MAYMES WILL1% B1X8V. SITE MANAGER REGIONAL AOMINISTRATOR. RESION I U,5. GEPARTMENT OF ENEASY U.S. NUCLEAR RESULATORY COMMIS$10M P.O. SOE 88 631 PAtt AVE.
MIDDLETONN. PA 17957-4311 RING OF PRUS$1A. PA. 19406 DAVID J. MCSOFF
{
J0MN F. WOLP. ESO., CHAIRMAN.
O! VISION OF TMAEE MILE ISLANS PROSa AMS ADMINISTRATIVE JUSSE NE-23 3409 SNEPHERO ST.
U.S. OEPARTMENT OF ENERSY CHEVY CHA3Ee MO.
20015 WASNINGTON. OC. 20545 OR. OSCAR N. PARIS WILLIAM LOCNSTET I
AOMINISTRATIVE JUSSE 194 OAVEY LA50eATORY-ATOMIC SAFETY ANO LICENSING PENNSYLVANIA STATE UM1VERSITY BOABO PANEL UNIVERSITY PARE. PA 16802 U.S. NUCLEAR RESULATORY COMMISSION KASHIMSTON. O.C. 20555
)
THE PATRIOT OR. FRE0ERICE J. SHOW 412 MARKET ST.
j ADMINISTRATIVE JUO6E MARRISSUSE. PA 17tOS ATOMIC SAFETY AMO LIC1NSING l
80ARO PANEL l
U.S. NUCLEAR RESULATORY COMMISSION ROBERT 3. 30RSUM KASNINGTON. O.C.
20SSS BASCDCE & WILCOX 1
NUCLEAR PONER SENERAT10N O! VISION RARIN W.
CASTER SUITE 229 f
ASSISTANT ATTORMEY SENERAL 7919 WOOOMONT AVE.
l SOS EXECUTIVE NOUSE BETMSSOA. MO.
28814 I
P.O. 802 2357 MARRIS3URSe PA 17120 JustTN A. 000SEY 1315 WALNUT STREET l
OR. JUO1TH W.
J0MMSAUD SUITE 1632 ENVIRONMENTAL COALITION ON PHILADELPNIA. PA 19107 NUCLEAR POWER 435 GeLANDO AVE.
LINGA W. LITTLE STATE COLLESE. PA 16801 S000 NERMITASE OR.
SALEISNe NC 27612 GEOBSE P.
TROW 50!OSE. ESS.
SMAW. PITTMAN. POTTS AND MARV!M 1. LEWIS TROWORIOGE 6504 SSADFORD TERRACE KASHINGTON. OC 20036 PHILABELPNEA. PA 19149 ISOS M.
St.
NW.
JANE LEE ATOMIC SAFETY AND LICENSIMS 90 Ate PANEL 183 VALLEY RO.
U.S. NUCLEAR RESULATORY COMMISSION ETTERS. PA 17319 WASHINGTON. OC 20555 J.S. LIBERMAN. ESSUIRE ATOMIC SAFETY ANO LICENSING APPEAL PANEL SEALACE. ISRAELS. LIBERMAN
)
U.S. NUCLEAR RESULATORY COMMISSION 26 SSOADNAY KASNINGTON. OC 20$$5 NEW YORK. NY 19804
}
SECRETARY WALTER W. COMEN. CONSUMER ADVOCATE U.S. NUCLEA8 RESULATORY COMMISSION DEPARTMENT OF JUSTICE l
ATTPs CMIEF. 00CKETING & SERVICE BRANCN STRAWSERRY SOUAst. 14TH FLOOR WASHINGTON. OC 20555 NAARISSUeS. PA 17t27 I
E0WARO O. SWARTZ l
BOARO OP SUPERVIS005 MR. LAERY NOCNENDONER OAUPHIN CCUNTY COMMISSIONER LONDONDERRY TOWNSNIP RF0 et SEYERS CNutCN B0.
j P.O.
BOX 8295 MARRISBURS. PA 17108-1295 MIDDLETOWN. PA 17097 JOHN t. MINNICN. CNAIRPERSON.
ECOERT L. EMUPP. ESOU1RE DAUPN1H COUNTY 80ARO OF COMMISSIONERS ASSISTANT *0LICITOR EMUPP AMO AMOSEWS DAUPHIN COUNTY COURTMOUSE P.O.
BOX P FRONT AND MARKET STREETS 407 N.
FRONT ST.
NARE!$5URS. PA 17101 MARRISSURS. PA 17108 OAUPMEN COUNTY OFFICE OF EMERSENCY J0MN LEvtN. ESOUIRE PREPAREONESS PENNSYLVANIA PUBLIC UTILITIES COMM.
COURT MOUSE. ROOM 7 P.O.
BOX 3265 FRONT & MARKET STREETS MARRISSURS. PA 17t20 MARRISBURS. PA 17101 U.S.
(NVIRONMENTAL PROTECTION AGENCY MONORASLE MARK COMEN Sl2 E-E MAIN CAPITOL SUILO!PS REGION !!! 0FFICE MAaRISauRS. PA 17t20 ATTNt EIS COOR0!NATOR CURTIS SUILOING ($1XTN PLOOR) 6TM & WALNUT STREETS PHILADELPMIA. PA 19106 TNOMAS M. SERUSKY DIRECTOR SUREAU OF RAOIATION PROTECTION DEPARTMENT OF ENVIRONMENTAL RESOURCES P.O.
BOX 2063 NARRISBURS. PA 17120 DAVIO MESS OFFICE OF ENVIRONMENTAL PLANNING DEPARTMFMT OF ENVIRONMENTAL RESOURCES P.O. 80X 2063
__ _,_MARR$QCISES. PA._17120
.