Discusses Surveillance & Reinsp Program Under Implementation for Plant.Nrc Understands Initial Program Would Be Adjusted in Hanger & Electrical Areas Based on June 1982 Insp Results & That 100% Reinsp of Pipe Suspension Sys Would Continue
ML20028E975
Person / Time
Site: Zimmer
Issue date: 01/24/1983
From: Warnick R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
Shared Package
ML20028E976 List:
References
NUDOCS 8301280312
Download: ML20028E975 (2)


Text

_ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _

/

UNITED $TATES f,

NUCLEAR REGULATORY COMMISSION i

nEGION lit o

795 MOOSEVELT MOAD Y

GLEN ELLYN. 8LLINO85 40137 g

g

'JAN 2 4 g Docket No. 50-358 Cincinnati Gas and Electric Company ATTN:

Mr. Earl A. Borgmann Senior Vice President Engineering Services and Electric Production 139 East 4th Street Cincinnati, OH 45201 Gentlemen:

This letter refers to your August 4, 1982 (QA 1916) letter confirming your understanding of the CG&E surveillance and reinspection program being implemented for the Wm. H. Zimmer nuclear station as described in your letters dated March 24 (QA 1621) and April 29, 1982 (QA 1729) and IE Inspection Report 50-358/82-07.

As stated in our August 3, 1982 letter and your August 4, 1982 (QA 1916) letter, the initial program would be adjusted in the hanger and electrical i

areas based on the previous inspection results (June 1982) and would continue, as described, in the future.

It was also our understanding that the "100's reinspection of the installed safety-related pipe suspen-sion system components" referred to contractor inspections resulting from previous inspection findings by the NRC.and commitments made by CG&E would continue.

4 l

l l

l 8301200312 830124 fl:0f PDR ADOCK 05000359 l

0 PDR t

]

JAN 2 4 19g.-

Cincia.nati Gas and Electric 2

Company

}

i 4

Your cooperation with us is appreciated.

i Sincerely,

" Original sis ad L/

P.. F. Wa rn i ck" R. F. Warnick, Acting Director i

Office of Special Cases cc:

J. R. Schott, Plant Superintendent q

~

J. D. Flynn, Manager, Licensing Environmental Affairs Department jl cc w/1tr dtd 8/4/82:

DMB/ Document Control Desk (RIDS)

Resident Inspector, RIII q

Harold W. Kohn, Power Siting Commission Citizens Against a Radioactive Environment Helen W. Evans, State of Ohio l

Robert M. Quillin, Ohio Department of Health Thomas Applegate Thomas Devine, Associate Director, Institute for Policy Studies Dave Martin, Office of l

Attorney General Mark Wetterhahn, Esq.

i I

Jerome A. Vennemann, Esq.

Gretchen Hummel, Ohio Consumers' Counsel James R. Williams, State l

Liaison Officer, Ohio l

Disaster Services Agency l

l RIII, d g) RIII RI RIII RIII WN

^thf DtW/

2R0 Schweibinz/jp in ter Danielson War ic 1/6/83

)

f / t./f3-

/ pf yg

.