Forwards Updated LER 82-013/03L-1
Date released: 02/11/2020 Download: ML20028E101


Updated LER 82-013/03L-1:on 820121,while Attempting to Open HPCI Sys Steam Supply Outboard PCIV,1-E41-F003,valve Motor Tripped on Magnetics.Caused by Failure of Armature Windings. Motor Rewound & Reinstalled
ML20028E104
Person / Time
Site: Brunswick 
Issue date: 01/14/1983
From: Pastva M
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20028E104 (2)
Forwards Updated LER 82-013/03L-1
ML20028E100
Person / Time
Site: Brunswick 
Issue date: 01/14/1983
From: Dietz C
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20028E100 (1)