e-DUKE POWER GOMPANY 1'
P.O. ISOx 33189 CHAMLOTTE, N.C. 28242 II AL 15. TIJCKEH (704) 373-45:M TELEPHONE
,- }
vwm e.r mew
.; jJ p muu...amnw.
Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region ii 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 Re:
Catawba Nuclear Station Units I and 2 Docket Nos. 50-413 and 50-414
Dear Mr. O'Reilly:
Pursuant to 10 CFR 50.55e, please find attached a Supplemental Response to Significant Deficiency Report SD 413-414/82-18.
Very truly yours, C
y
.r4 /nkfc tw.
Hal B. Tucker RWO/php Attachment cc:
Director Mr. Robert Guild, Esq.
Office of Inspection & Enforcement Attorney-at-Law U. S. Nuclear Regulatory Commission P. O. Box 12097 Washington, D. C. 20555 Charleston, South Carolina 29412 Mr. P. K. Van Doorn Palmetto Allian.
NRC Resident inspector 2135b Devine Street Catawba Nuclear Station Columbia, South Carolina 29205 OPFICIAL COPY 9301200301 83o11o PDR ADOCK 05000413 I88-7 S
g
- ,N DUKE POWER COMPANY CATAWBA NUCLEAR STATION SIGNIFICANT DEFICIENCY Report Number: SD 413-414/82-18 This report is submitted to revise corrective action stated in our October 1, 1982 report.
Revise to read as follows:
CORRECTIVE ACTION Teledyne-McKay contends that their reading of SFA 5.20 is correct. To support this position, Teledyne-McKay has requested a Code interpretation from ASME. Pending the outcome of the Code interpretation, Teledyne-McKay will be removed from our Approved Vendor's List. All parties receiving the list will be notified by January 15, 1983