. _

)

BEFORE THE UNITED STATES NUCLEAR Rt'?ULATORY C0f1 MISSION i

l In the Matter of

)

j OMAHA PUBLIC POWER DISTRICT

)

Docket No. 50-285 (FortCalhounStation,

)

Unit No.1)

)

APPLICATION FOR AMENDMENT 0F GPERATING LICENSE Pursuant to Section 50.90 of the regulations of the U. S. Nuclear Regulatory Commission ("the Commission"), Omaha Public Power District, i

holder of Facility Operating License No. DPR-40, herewith requests that Sections 2.2.1(9) and 2.2.1(10) of the Technical Specifications set j

forth in Appendix A to that License be amended to revise the minimum temperature for conducting secondary side hydrostatic testing and leak 0

0 testing from 82 F to 73 F.

1 The proposed changes in Technical Specifications are set forth in Attachment A to this Application.

A discussion, which demonstrates that the proposed changes do not involve significant hazards considerations, i

is appended in Attachment B.

The proposed Amendment is deemed to be Class III Amendment, within the meaning of Section 170.22 of the regulations of the U. S. Nuclear Regulatory Commission. Accordingly, a check for j

the appropriate fee, $4,000.00, accompanies this Application. Jus ti fi-i cation for classification of the Amendment pursuant to 10 CFR 5170.22 is included in Attachment C to this Application. The proposed changes in specifications would not authorize any change in the types or any increase in the amounts of effluents or any change in the authorized 4.

power level of the facility.

l 8301050237 830104 PDR ADOCK 05000285 I

P PDR

j

~

l.

WHEREFORF, Applicant respectfully requests that Sections 2.2.1(9) and 2.2.1(10) of Appendix A to Facility Operating License No. DPR-40 be amended in the form attached hereto as Attachment A.

s OMAHA PUBLIC POWER DISTRICT 4

By ADE C W.C.Jopss Division, Manager Production Operations Subscribed and sworn to before me this 3 u[

day of January,1983.

l.

n e A.,!

=

/,// Notary Public aumm astur-Sieie d ****u J.T. GLEASON isy team. bg kh 23,1986 a