ML20027E407

From kanterella
Jump to navigation Jump to search
Submits Daily Highlight Re Crack in Fuel Element Face Discovered During 820426 post-irradiation Exam Insp of Elements Removed During 810701 Second Refueling.Second Crack Noted During Recent Hot Cell Exams.Evaluation Continuing
ML20027E407
Person / Time
Site: Fort Saint Vrain 
Issue date: 07/08/1982
From: Kuzmycz G
Office of Nuclear Reactor Regulation
To: Carter J, Harold Denton, Eisenhut D
NRC
Shared Package
ML20027E400 List:
References
FOIA-82-428 NUDOCS 8211150180
Download: ML20027E407 (1)


Text

-

. ~ _ -

]b

A tea

o

  • UNITED STATES I'

E WASHINGTON, D. C. 20S$5 (M h"h e

NUCLEAR' REGULATORY COMMISSION

[

July 8, 1982

+

3 wb 4

M f

MEMORANDUM FOR:

H. Denton J. Carter

'D. Eisenhut R. Purple DL Assistant Director S. Hanauer R. Vollmer_,

pls9

'A. Mattson d

H. Thompson

.G

/.

J. Sniezek T. Ippolite C. J. Heltemes, AEOD I

yN THRU:

Robert A. Clark, Chief 4

7 Operating Reactors Brarich #3, DL FROM:

George Kuzmycz, Project Manager Operating Reactors Branc!) #3, DL

[

SUBJECT:

DAILY HIGHLIGHT Fort St. Vrain s

On April 26, 1982, while performing a Post' Irradiation Examination inspection of fuel elements that had been removed during the second refueling at Fort St. Vrain, one fuel element was found to have a crack on one face. The-l crack extended across the minimum cross-section between a coolant hole and one face of the block (%.5"), vertically down the full length of the

. block (31.2"), and terminated at the lower exit of the coolant hole.

The element was placed in the initial core on January 4, 1974 into Region 8 Column 5, Layer 6, where it remained until removed during the second refueling

.on July 1, 1981. The element accumulated a burnup of 19,497.15 MWD per i

initial metric ton of uranium plus thorium.

During recent hot cell examinations at General Atomic's facilities the crack was found to extend to the dowel pin. Also, the fuel element block, beneath l

the block where the crack was originally found, contained a crack. This second crack is on the same face and in the same orientation as the crack

~in the first block.

Further analyses and examinations are being performed to evaluate L'oth cracks.

George Kuzmycz, Project Manager Operating Reactors Branch #3 Division of Licensing

?

/ 8211150180 821008 f PDR FOIA AUDINO2-428 PDR

.