Notification of 821103 Meeting W/Utils & Franklin Research Ctr in Bethesda,Md to Discuss Design (IE Bulletin 80-11) & Use of Energy Balance Technique & Arching Theory
ML20027D709
Person / Time
Site: Millstone, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Oconee, Palisades, Saint Lucie, Oyster Creek, Brunswick, Turkey Point, Vermont Yankee, Haddam Neck, Ginna, Duane Arnold, Maine Yankee, Quad Cities, 05000000
Issue date: 10/07/1982
From: Trammell C
NRC
To:
NRC
Shared Package
ML20027C596 List:
References
IEB-80-11, NUDOCS 8211080271
Download: ML20027D709 (4)


Text

. - _ - _ _

OCT 7 1982 Docket Nos: 50-331 50-219 50-346 50-237/249 DlkliLUMIIDi, hh 50-348/364 50-254/265 dlach5. FIT 5s.

50-263 50-269/270/287 3RGR '

50-277/278 50-335 L PDR 50-250/251 50-245 NSIC 50-325/324 50-271 ORB #3 Rdg 50-317/318 50-309 '

CTrammell 50-336 50-244 RAClark 50-255 50-213-ACRS-10 a

OELD~

FACILITIES:

Duane Arnold Oyster Creek 1 ELJordan Davis-Besse#1 Dresden 2/3 JMTaylor Farley 1/2 Qecd Cities 1/2 Monticello Oconee 1/2/3 Peach Bottom 2/3

.St. Lucie 1 Turkey Point 3/4 Millstone 1 Brunswick 1/2 Vermont Yankee 1 Calvert Cliffs 1/2 Maine Yankee Millstone 2 Ginna Palisades Haddam Neck LICENSEES:

Iowa Electric Power & Light GPU Nuclear Toledo Edison Commonwealth Edison Alabama Power Duke Power Northern States Power Vermont Yankee Nuclear Power Philadelphia Electric Maine Yankee Atomic Power Florida Power & Light Rochester Gas & Electric Carolina Power & Light Connecticut Yankee Atomic Power Baltimore Gas & Electric Northeast Nuclear Energy Consumers Power NOTICE OF MEETING RE: MASONRY WALL DESIGN (IE BULLETIN 85-11) - USE OF "ENERCY BALANCE TECHNIQUE" AND " ARCHING THEORY" DATE AND TIME: Wednesday, November 3, 1982.

9:00 a.m.

LOCATION:

Room P-118, Phillips Building, 7920 Norfolk Ave., Bethesda, Md.

ATTENDEES:

Interested licensees referencing the " energy balance technique" and/or

" arching theory" in responses to IEB 80-11, plus those listed below:

NRC Franklin Research Center (FRC)

Franz Schauer Vu Con James Kr.ight David Jeng Other Nilesh Chokshi Dr. Ahmad Hamid Charles Trammell Dr. Harry Harris K. C. Leu (Drexel University-consultants to FRC)

DESIG' ORIGIITAL

$k !a! O Q

Certified B, qfhhu CDA44t.

Background:

All plants / licensees listed above have made use of the

" energy balance technique" and/or " arching theory" in response to IEB 80-11, " Masonry Wall Design." Those plants referencing these techniques and their respective A/Es are identified in Attachments 1 and 2.

Technical reports on the applicability of these techniques to masonry wall construction are attached for information.

See Attachments 3 and 4.

The NRC s'taff and its consultants have reviewed these techniques and have concluded that they must be substantiated by appropriate testing in order to be accepted by NRC.

This approach of conducting relevant testing to confirm design adequacy for masonry construction has been previously adopted in masonry wall evaluations for Trojan, San Onofre 1, and Clinton 1.

PURPOSE OF MEETING:

The purpose of the meeting is to encourage the formation of an owners group to conduct appropriate testing which is needed to substantiate the validity of these techniques so that masonry wall evaluations for the identified plants can be concluded.

17 licensees (involving 29 plants) have used one or both of these analytical techniques. Substan-tial progress in resolving masonry wall design issues would result.

NRC/FRC and consultants will explain why these techniques cannot be accepted without further substantiation, and also discuss generally the types of tests needed.

Licensees would be able to explore commonality or uniqueness of design involved in the masonry construction of affected plants.

The meeting room has been reserved all day and will be available for licensees' use following the NRC presentation if desired.

COMMUNICATIONS:

Interested licensees are requested to contact either of the below NRC personnel if attendance is planned or if current attendance information is desired:

I Nilesh Chokshi 301-492-8973 Charles Trammell 301-492-7389 b

>M mad Charles M. Trammell Lead Engineer Masonry Wall Design Attachments:

1.

Plants using Energy Balance Technique 2.

Plants using Arching Theory 3.

Technical Report-Energy Balance Technique 4.

Technical Report-Arching Theory t

ENERGY RA1.ANCE TECHNIOUE PLANT

'A/E 1)

Duane Arnold.

Bechtel

2) Davis Besse 1, Bechtel 3)

Farley 1 & 2 Bechtel

  • 4)

F*enticello Bechtel 5)

Peach Bottom 2/3 Bechtel

  • 6)

Turkey Point 3 & 4 Bechtel

  • 7)

Brunswick 1 & 2 linited Engineers.

  • 8)

Calvert Cliffs 1 & 2 Bechtel

  • 9)

Millstone 2 Bechtel

  • 10) Palisades Bechtel
  • 11) Oyster Creek Bechtel
  • 12)

Dresden 2 & 3 Bechtel

  • 13)

Quad Cities 1 & 2 Bechtel l

l

  • These plants also use the " Arching Theory."

l l

4 ARCHING THEORY PLANT A/E

1) Oconee 1, 2 & 3 Be chtel
  • 2) Turkey Point,3 & 4 Bechtel 3)

St. Lucie 1 Ebasco.

  • 4) Brunswick 1 & 2 Ilnited Engineers 5)

Millstone 1 Ebasco

  • 6)

Millstone 2 Bechtel

  • 7)

Monticello Bechtel

  • 8)

Calvert Cliffs 1 & 2 Bechtel

  • 9) Palisades Bechtel 10)

Vermont Yankee Ebasco'

11) Maine Yankee S&W
  • 12)

Oyster Creek Bechtel 13)

Ginna Gilbert

  • 14)

Dresden 2 & 3 Be chtel

  • 15) Quad Cities 1 & 2 Bechtel
16) Haddam Neck S&W
  • These plants also use the " Energy Balance Technique."