Forwards LER 82-031/03L-0
Date released: 02/10/2020 Download: ML20027B751


LER 82-031/03L-0:on 820826,main Feed Regulating Valve FCV-FW-498 for C Steam Generator Found Leaking Excessively When Shut.Caused by Improper Seating of Seat Assembly Into Valve Body.Maint Procedure Revised
ML20027B752
Person / Time
Site: Beaver Valley
Issue date: 09/17/1982
From: Lacey W
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20027B752 (2)
Forwards LER 82-031/03L-0
ML20027B750
Person / Time
Site: Beaver Valley
Issue date: 09/16/1982
From: Williams H
DUQUESNE LIGHT CO.
To: HAYNES R C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20027B750 (2)