_.

..-;,:.st:n o. c.:u:;

3 3 is J., :,..* j DEC 1 '. 3 78 FE!'03 A!!DUM F0D.:

L.D. Crocker, Technical Assistant i

Division of Project Management r

F",C" :

V. S. '!ocaan, Chief, Engineering ' ranch Division of Operating Reactors

3. K. Grires, Assistant director for Engineering &nd Projptse ThRU:

"i ision cf Operating Peactors

,m g t./

S'.'E.: EC T :

CS ?ICLIST 000 S'J""20.Y OF C0" E"SER ATE. I ALS FOR GPERATI:13 PLA'lTS T.EE :

f s

At the request of tne ACRS, the Engineering Branch, Division of Operating Reactors, has put t:gether a list of condenser tube materi als for cperating P'.2's.

This list is given in attachment 1.

The majority of the infomation was taken from stean generator operating history questionnaires supplied by utilities owning operating PWR's in response to a December 9,1977, generic NRC request for such infomation. Sixteen copies of each utility's comoleted questionnaires have also been fonvarded to-the ACRS.

Data for a few of the plants was taken from a paper presented at the June 12-16,1977, ANS 23rd Annual Meeting entitled, " Update of Operations With Westinghouse Steam Generators," by D. D.

Malinowski and u. D. Fletcher of Westinghouse. In some cases the tube material was taken from FSAR's. The tube material for the Robinson 2 condenser was taken from BNL-NUREG-50778, entitled,

" Denting of Inconel Steam Generator Tubes in Pressurized Water Reactors," Final Report, by Daniel Van Rooyen and John R. Weeks of BNL, published January,1978. For Three Mile Island 2, the utility supplied the infomation to us over the phone since it was not available in the FSAR.

-),

Vin ~ centi.Noonan, Chief Engineering Branch Division of Operating Reactors

Contact:

R. LaGrance

~

49-28060 cc:

V. Stello B. Grimes D. Ei senhut B. D. Li aw J. D. Neighbors J. Strosnider F. Almeter R. LaGrange 7812200307

s.

ATTACHMEtiT 1 5

Condenser Tube Materials for Operating Plants (PWR)

December,1978 f

I.

I

E Baaver Valley 1 Stainless Steel Cool.1 Cu and Stainiess Steel Ccok 2 Cu and Stainless Steel Farley 1 Titanium Ginna Admiralty and Stainless Steel Haddam Neck Admiralty and Stainless Steel Indian Point 2 Admiralty Indiari Point 3 Admiralty Kewaunee Adnicalty brass North Anna 1 & 2 Stainless Steel t

Point Beach 1 Admiralty Point Beach 2 Admiralty Prairie Island 1 Stainless Steel Prairie Island 2 Stainless Steel Robinson 2 90-10 Cu-Ni Salem 1 90-10 Cu-Ni San Onofre 1 90-10 Cu-Ni and Titanium (l)Surry1 90-10 Cu-Ni (I)Surry 2 90-10 Cu-Ni Trojan Admiralty brass and 70-30 Cu-Ni (I) Turkey Point 3 Al-brass (I)TurkeyPoint4

.Al-brass Yankee-Rowe Admiralty and Stainless Steel Zion 1 Stainless Steel Zion 2 Stainless Steel CE Arkansas 2 90-10 Cu-Ni Calvert Cliffs 1 70-30 Cu-Ni Calvert Cliffs 2 70-30 Cu-Ni Fort Calhoun 1 Stainless Steel Maine Yankee Al-brass and 70-30 Cu-Ni 4

.m c.'

1 l

t!SS:

PLA:;T CC:iDE!!SER VE;-^J tlAME TUBE l'ATERIAL (2) !!illstone 2 70-30 Cu-fli (3) Palisades 1 90-10 Cu-ili St. Lucie 1 Al-brass S 1'.I Aru nsas 1 Adairal ty Crystal River 3 70-30 Cu-iti Davis Besse 1 Stainless Stral 0:enee 1 Stainless Steel Oconee 2 Stainless Steel Oconee 3 Stainless Steel Rancho Seco 1 Stainless Steel Three Mile Island 1 Stainless Steel Three Mile Island 2 Stainles's Steel tiotes:

(1) Retubing condenser with Titanium.

(2) Was Al-brass up to 5/77.

(3) Previously Admiralty.

e

_. _ _ _ _ _