05000346/LER-1978-045-03, /03L-1:on 780503,first Reactor Vessel Stud Detensioned,Placing Unit Into Mode 6,requiring Audible Indication of Neutron Flux in Containment.Cause Was Procedure Error.Audible Indication Was Installed

From kanterella
(Redirected from ML20027A457)
Jump to navigation Jump to search
/03L-1:on 780503,first Reactor Vessel Stud Detensioned,Placing Unit Into Mode 6,requiring Audible Indication of Neutron Flux in Containment.Cause Was Procedure Error.Audible Indication Was Installed
ML20027A457
Person / Time
Site: Davis Besse 
Issue date: 05/30/1978
From: Hartigan J
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20027A454 List:
References
LER-78-045-03L, LER-78-45-3L, NP-33-78-55, NUDOCS 7812050162
Download: ML20027A457 (2)


LER-1978-045, /03L-1:on 780503,first Reactor Vessel Stud Detensioned,Placing Unit Into Mode 6,requiring Audible Indication of Neutron Flux in Containment.Cause Was Procedure Error.Audible Indication Was Installed
Event date:
Report date:
3461978045R03 - NRC Website

text

_

i U.S. NUCLEAR REGULATCRY COMMISSION

{

1 NRC EC.9M t$6 "

(7 77)

LICENSEE EVENT REPORT CONTROL SLOCK: l l

l l

l l

lh IPLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI f

l l@

l lo lil l 0l Hl Dl 3l Sl 1l@l 0l 0l -l Ol Ol Nl Pl Fl -l 0l 3l@l 4 l ll il II 1l@l 25 26 UCENSE TYPE 40 67 CAT $8 uCENsE NuMSER 7

8 9 UCENsEE CooE 14 15 IOi1i ERca dl 015101-10(314l6@l015 10 13 17 18 }@l0l5l3l0 CON'T 74 75 REPORT o ATE 80 68 69 EVENT oATE s

ooCKET NvMSER 60 61 EVENT DESCRIPTION AND PRCBABLE CONSEQUENCES h l

7 3

[T}T} l On 5/3/78, the first reactor vessel stud was detensioned in preparation for reactor It was not realized until 5/5/78 that this first stud detensioning l

ryry} l head removal.

This placed the unit in the Action Statement of T. S.

[

g l placed the. unit into Mode 6.

g ; 3.9.2 which requires audible indication of neutron flux in the containme i

Neutron flux indication j Room while in Mode 6.

Ne core alterations were in progress.

[TTiG l (NP-33-78-55)

[

p l was available with. two redundant source range neutron flux monitors.

l 60 lo te l I sveS"o*o's sN$e 7

8 9

  • T "c^o$E sveSe ceuPoNENTecoE lC l Ajg yg l ZlQ lV lE lS lS lE lL (g lZ lg g g cc 18 le 20 o 9 7

8 9

10 11 f2 IJ REV8sloN OCCURRENCE REPORT sEcuENTIAL CooE TYPE No

@ asg,o 17181 l.--J 101415l y

10 is l lLl

[]

g REPORT No.

EVENT YEAR LER R a;

,,,,2 5 22 23 24 26 27 28 29 30 31 32 K N ACT oN -

o PtA T ME Hours 22 s8 i FoR S.

svPPt E MANuPAC RER LGJ@l x i@

W@

W@

18I8181 I

lY Jg l42N [g l43N lg lZ lZ lZ lZ lg 44 47 3J 34 34 36 37 40 41 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Audible indication was installed l

gi;ogl The cause of this occurrence is procedure error.

h Spec g,,33 l on May 6, 1978, which removed the unit from the Action Statement of Tec

(

A modification was submitted to SP 1504.02 to insure personnel are

[

g l 3.9.2.

l aware that entry into Mode 6 begins with the first reactor vessel stud detensioning j

iti3l l

L.i.j,4j I oTutRsTATus @oiEc*oEv' oiscovERv oEscRiPTioN h l

'sT4IE NPowsR 11151 J@ l 0 l 010 l@l NA l

l A l@l NA tocaTioN oP RetsAse @

a,y co'OEw AucuNTcP AcTmTv @ l 7

l J

Retsasso oP REteAst l NA l NA li Is I LZj @ [ Z,J@Oss erscRiPTioN @

l PsRsoNNetexPos NuMe R TvPs li1711 01 01 Ol@lZl@lNA PtRsoNNe'u'iN;u'litsetscRiPTioN@

l uuvstR li j a l l 01 01 01@] NA so 7

8 9 11 12

'$i's * *" Es^c"'PTlo'N *'"" @

]

ltio1IZl@lNA 80 7

8 9 10 d

of CRiPTioN I

IIfffII!II Iili

[.ZJ.o.] dggg61 NA ig 68 69 60 5 IO'l 8 'l 2 0 5 D 1rbbrei::an 419-259-5000 txe. 230 7

8 9

,,c y,;

"5 Ta n79

1 i

l TOLEDO EDISON COMPANY DAVIS-BESSE UNIT ONE NUCLEAR POWER STATION SUPPLEMENTAL INFORMATION FOR LER NP-33-78-84 DATE OF EVENT: June 19, 1978 FACILITY: Davis-Besse Unit 1 IDENTIFICATION OF OCCURRENCE: Borated Water Storage Tank (BWST) low level trip setpoint out of tolerance Conditions Prior to Occurrence: The unit was in Mode 6, with Power (MWT) = 0, and Load (MNE) = 0.

Descriotion of occurrence: During performance of Surveillance Test ST 5031.01,

" Safety Features Actuation System (SFAS) Monthly Test" on June 19, 1978, at 1130 hours0.0131 days <br />0.314 hours <br />0.00187 weeks <br />4.29965e-4 months <br />, the BWST low level trio setooint for SFAS Channel 1 was found to have been out of tolerance.

Technical Specification 3.3'.2.1 requires the operability of four BWST low level instrument strings (one in each SFAS channel) in Modes 1, 2 and 3.

Since the unit was in Mode 6 at the time of the occurrence, Action Statement 9 was not applicable. This occurrence is being reported as documentation of component failure.

Designation of Aeoarent Cause of Occurrence: The cause of the occurrence is attributed to a component failure of the level trip module. The setpoint on 1

level switch LSL-1525A had apparently drif ted.

L Analysis of Occurrence: There was no danger to the health and safety of the public or to unit personnel. The BWST level instrument strings for SFAS Channels 2, 3 and 4 were operable during the, period that indication for Channel 1 was inoperable.

The unit was in Mode 6 at the time of the occurrence.

Corrective Action

The level trip module was replaced with a new module under Maintenance Work Order IC 386-78. After the module was bench tested and Surveil-lance-Test ST 5031.01 was successfully performed, BWST level indication for SFAS Channel 1 was declared operable at 1535 hours0.0178 days <br />0.426 hours <br />0.00254 weeks <br />5.840675e-4 months <br /> on June 19, 1978.

Failure Data: BWST level indication was previously reported to have been inopera-ble in Licensee Event Reports NP-33-77-107 and NP-33-78-01 due to frozen sensing lines. BWST level indication was previously reported to have been inoperable in Licensee Event Report NP-33-78-73 due to component failure other than instru=ent drift.

LER #78-070 e

8 t