a. ;
g,yy 4
7
.J,E' P.00M
!:-l
- ,' A UNITED STATES OF AMERICA
'A'
'4h "s yr.
A 6 NUCLEAR REGULATORY COMMISSION 7.d f,s *. '.n, p,. -
.p k. k '?"
d
'h.
%'.V EF' ORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPATI
)
Docket No. 50-2 75-OL
)
Docket No. 50-323-OL Units 1 and 2
)
)
Diablo Canyon Site
)
)
REPLIES OF PACIFIC GAS AND ELECTRIC COMPATI TO INTERVENORF' INTERROGATORIES DATED SEPTEMBER 27, 1978 October 17, 1978 762 ~'.01 o o 3 9 (v-x
a t-Interrogatory No. 1:
For each of the contentions relating to the adequacy of the seismic design of the Diablo Canyon Nuclear Power Plant, identify
-each witness the Applicant intends to call in the licensing hearing.
Recly:
Witnesses testifying on the contentions relating to the adequacy of the seismic design of the Diablo Canyon Nuclear Power Plant were identified in a letter filed with the Board on August 28, 1978,' along with the areas of expertise to which they will address their testimony.
The outlines of the testimony have developed further since that date and the following additional names should be added to the witness list:
Name Affiliation Area of Testimonu John A. McLauglin PGandE Structural Oscar A. Rocha
.PGandE Structural M. E.
Lee PGandE Structural T. N. Crawford PGandE Electrical R. M.
Laverty PGandE Mechanical Robert Lawson Harding-Lawson Structural T. Udaka Harding-Lawson Structural David Williams URS Structural As we have done in the past licensing hearings, we will divide our testimony into sections; each section of testimony will be sponsored by one or two principal authors.
During the hearing, a summary on each section will be given by one of the authors of written testimony.
We will make additional witnesses available or 1
~
.o s
Reply to Interroaatorv No. 1 continued:
a panel at the time of cross-examination on each section of testimony to assure that we can provide both general and specialized information on each subject.
The list of titles of testimony sectiona and authors is shown below.
We have al'so attached to this answer, as requested in Interrogatory No. 2 (d) and (e), a summary of the educational back-ground and professional employment for each witness' named on our original witness list as well as for those added in this answer.
Title of Testimony Authors Establishment of Seismic Events R. V. Bettinger for Which Plant is Designed J. B. Hoch Characteristics of Faults R. Jahns D. Hamilton Characteristics of Earthquakes S. Smith Characteristics of Ground Motion at Site J. A. Blume Establishment of the Ability.of the Plant to Withstand the Design Seismic Events-J. B. Hoch Containment Structure V. J. Chio L. Malik Auxiliary Building V. J. Ghio L. Malik Intake Structure V. J. Ghio D. Lang Turbine Building V. J. Ghio D.
Lang Outdoor Tanks V.
J. Chio
+
D. Jhaveri 2uried Tanks a Piping Systcmc J. A. :-:cLau lin R. T. Lawsc" 2
,m.--
7
., - - - - =
-c
.-e.
e
-e
- e
.?
h Repiv to Interrogatory No. 1 continued:
Title of Testimony Authors Introduction & Evaluation of Plant System H. J. Gormly Systems & Functions Required
- W. C. Gangloff-Reactor & Reactor Coolant System T. Esselman Auxiliary Mechanical Equipment T. Esselman P. G. Antiochos Other Class I Piping Systems T. Esselman R. E. Bacher Electrical Equipment & Instrumentation T. Esselman R. A. Young Interrocatorv No. 2:
For each and every person identified in response to interrogatory number (1) above, identify the following:
a) the substance of the facts and opinions to which the witness is expected to testify; b) the grounds for each opinion; c) all documents, and portions thereof, to which i
each expert will refer or upon which he will rely in the licensing hearing.
If reference is made to the SER or FSAR and any amendments thereof, identify the specific section upon which each witness will rely; d) each witnesses' educational background; e) any professional employment or other work experience relating to the area of expertise upon which each witness will rely; i
i f) all articles, books, scientific papers or abstracts, studies, analysis authored by the witnesses and re-lating to the area of expertise upon which each witness will rely.
i i
1 3
.~.-s
--,,-,w y
.y c......y.
.m.
m r,w
r 8
Reply:
- As de, scribed in Reply to Interrogatory No. 1, the witnesses are divided into three categories:
(1) Those presenting direct testimony; (2) those available on panels for cross-examination of the direct testimony; and (3) those who may be used for rebuttal and will be available for answers to " detail" questions, specifics of which may not be fully known to direct testimony or panel witnesses.
As testimony is due to be in the hands of all parties on November 15, 1978, none of it has been written as of the date of -these answers.
The opinions and supporting facts of the listed witnesses are how-ever, available in the FSAR, amendments thereto and testimony before the ACRS full and subcommittees.
As the. testimony has not been written, it is impossible to identify with specificity sections of
}
the FSAR, abstracts, analysis, etc., relied upon.
That information will be provided as available pursuant to the applicable rules of-discovery.
Direct testimony supplied on November 15 will contain
- detailed bibliographies or references.
t e
i 4
1 1
,-r
--n
-,---y-m- ~ -
--,,c-..
- -. ~, -, - - ~. - -
-e
-v-,
e N.
3 (a) :
Interrogatory o
Does the Applicant know what a three dimensional soil structure interaction analysis is?
Reoly:
Yes.
Interrocatorv No. 3 fb) :
Describe a three dimensional soil structure interaction analysis.
Recly:
A three dimensional soil structure interaction analysis is a procedure that evaluates the effect of earth motions of various types and directions on a foundation, and the effect of the response of the foundation on the surrounding soil.
The motions are considered in three dimensions.
Models, idealizations, and assumptions can be used according to the importance of the various aspects in the over-all results.
The significance of these assumptions vary over a wide range in various applications ranging from design to research.
Interrocatorv No. 3 (c):
Has the Applicant or any of its consultants performed a three dimensional soil structure interaction analysis on the Diablo Canyon Nuclear Power Plant?
Recly:
Yes.
Interrocatory No. 3 (d) :
If so, please describe the results of that analysis and identify all documents that contain the results of such analysis.
Reciv:
Results are described in Ecctions 3.7 End 3.3 cf tha
~2'~
in chapters 3 and 4 and Appendix D of the report titled " Seismic 5
Reply to Interrogatory No. 3 (d) continued:
Evaluation for Postulated 7.5 M Hosgri Earthquake. "
Interrocatory No. 3 (e) :
If the Applicant has not performed such analysis, state why they have not.
Reoly:
Not applicable.
Interrocatorv No. 3 ( f) :
To the Applicant's knowledge, has the Staff or any of its consultants performed a three dimensional soil structure interaction analysis on the Diablo Canyon Nuclear Power Plant?
Reoly_:
No.
Inte_rrocatorv No. 3 (a):
If so, has the Applicant had the opportunity to review the results of that analysis?
If the Applicant has reviewed the results of such analysis, summarize those results.
Identify any documents that contain the results of such analysis.
Recly:
Not applicable.
Interrocatorv No. 3 (h) :
Has the Applicant ever discussed with the Staff the need to perform a three dimensional soil structure interaction analysis on the Diablo Canyon Nuclear Power Plant?
If so, please summarize those discussions.
Identify any rules or memorandum relating to such discussions.
Reply:
Yes.
A meeting with Staff February 4, 1977 covered the methods of analysis, including the use of fixed base models in accordance with the NRC Standard Review Plan.
The Staff has 6
Reply to Interrocatory No. 3 Ch) continued:
concurred with.the fixed base analysis.
This conclusion is stated in SER Supplement No. 7, Sec. 3.8.5.3 (4).
Interrogatorv No. 3 (i) :
Is the Applicant aware of any person who has performed or has allegedly performed a three dimensional soil structure inter-action analysis on the Diable Canyon Nuclear Power Plant?
If so, please identify each person.
Reply:
No, other than Applicant and its consultants.
Interrocatorv No. 4:
Identify all documents upon which the Applicant will rely for estimating peak parameters of a 7.5 magnitude earthquake at short distances.
If Ehe SER or FSAR is cited, please provide the section number.
Reolv:
Seismic Evaluation for Postulated 7.5 M Hosgri Earthquake -
Chapter 3, and references contained therein.
Interrocatorv No. 5:
Identify all documents upon which the Applicant will rely to support the reduction of the peak acceleration as measured in the free field to an " effective acceleration."
If the SER or FSAR is cited, please provide the section number.
Reo(E:
Same as reply to Interrogatory No. 4.
1.errocatorv No. 6:
Identify all documents upon which the Applicant will rely to support use of a tau effect to reduce by varying amounts the de-sign response ' spectra for those structures of the Diablo Canyon Nuclear Power Plant having foundations extending over large areas.
If the SER or FSAR is cited, please provide the section number.
2 Ecrli:
Same as reply to Interrogatory No. 4.
7
s s
Interrogatory No. 7:
Identify all documents upon which the Applicant will rely for the selection of peak acceleration, velocity, duration and dis-placement parameters that describe the safe shutdown earthquake' for the Diablo Canyon Nuclear Power _ Plant.
please provide the section number.
Reolv:
Chapters 2 and 3, FSAR, and Chapters 2 and 3 of Seismic Evaluation for Postulated 7.5 M Hosgri Earthquake.
Interrocatory No. 8:
Identify any documents, including notes, letters and memorandum, that describe, summarize or report any meetings between Staff consultant, Dr. Nathan Newmark, and Applicant employees or consultants during the course of reanalysis.
Reference is made to the meeting of March 13, 1978, as well as any other meeting.
Reniv:
Criteria for reanalysis were set February 2, 1977.
There-were no meetings subsequent to that date with Dr. Newmark other than the meeting on March 15, 1978.
Applicant does not have any documents regarding that meeting other than the notice of same which has already been produced.
Interrocatorv No. 9:
Identify all documents, notes, memorandum and reports relating to, or reporting on, or issuing from the Diablo Canyon Seismic Research Program (SRP).
See Attachment 1.
Reely:
Documents responsive to this Interrogatory will be available in' Room 767, 215 Market Street, San Francisco, commencing October 20, 1978.
As there are numerous documents covering a time period from early 1977 to the date of the recuest it will take the Applicant 8
i Reply to Interrocatory No. 9 continued:
somewhat longer to provide an index, but it is anticipated that the index will be available on October 27, 1978 and will be furnished to Intervenors.
We declare under penalty of perjury the foregoing Replies To Interrogatories are true and correct to the best of our information, knowledge, and belief.
(
.f &
's
/1 f( '
Bruce Norton Ph ip A. Crane, Jr.
$6L/ W D A Malcolm H. Furbush i
Dated:
October 17, 1978 9
i_
l UNITED STATES Gr AMEnICA g
NUCLEAR REGULATORY COMMISSION BEPORC T!!E ATO"IC SAFCT2 AMD LICZMSING BOARD In the b. tter of
}
}
Docket Nos. f0-275 0.L.
PACIFIC GAS AND ELECTRIC CCMPANY
)
50-323 0.L.
)
(Diablo Canycn Nuclear Pouer
)
Plant, Units No.1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFCTY ::3ARI::GS Name:
Panos G. Antioches Title or Position:
Mechanical Engineer Degrecs:
_B.S. in Mechanical and Electrical Engineering; National T:chnical University, Athens, Greece (1964)
M.S.,
University of California, 1969 3
Profaccional E ?erience:
?.egistered Professional Engineer (::echanical) i State of California.
Employed at PGandE since 1969.
1969-1974 - Systs:s Engineer, Diablo Canyon 1975-1973 - Involved with seismic cualifications of i
1 mechanical ecuipment for Diablo Canycn.
The first five years of my involvement l
with Dia;lo Canyon I spent as Systems o
t Engineer.in the area cf Turbine-Generator I
and associated systems, and the Circulating I
Water System.
I also have been Responsible l
Engineer for two safety-related sys'tems:
Emergency Diesel Enginc-Generators and i
l Auxiliary Saltwater System.
Major areas I
of technical involvement for the above are:
l Heat Transfer, Fluid Flew, Stress Analysis, t
1 i
-1 Panos G. Antiochos Page Two The last.four years I have spent almost exclusively in the seismic qualification of mechanical equipment for Diablo Canyon.
I have performed dynamic analyses of'.various ccmponents (pumps, heat exchangers, tanks, valves, etc. ), using a verified 4
computer code (STRUDL) and in accordance with applicable US:iRC Regulatory Guides as well as ASME III, IEEE-344, AISC'and AWS codes.
I have specified seismic test procedures and have parti-I cipated in in-place as well as shaker-table testing of vital Diablo Canyon equipment and components.
~
4 D
J
~
UNITED STATES OF AMERICA NUCLEAR REGULATORY CCMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
l RESUME OF QUALIFICATIONS FOR SAFETY HEARING 3 Name:
Richard E.
Bacher Title or Position:
Senior Mechanical Engineer Degrees:
B.S.,
Mechanical Engineering, 1968 (San Jose State College)
Professional Experience:
Employed at PGandE since 1963.
I have
'ceen performing and supervising work in piping design in the Department of Mechanical a'nd Nuclear Engineering.
At the present time, I am a Senior Mechanical Engineer and supervise four engineers on a regular basis in addition to defining and reviewing the work of several.
consulting firms.
The work of my group consists of dynamic piping analysis, dead load analysis and cede compliance work.
These tasks include stress analysis of pipe and pipe supports for nuclear and other pcwer plant designs.
4
s UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 O.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Richard V.
Bettinger Title or Position:
Chief Civil Engineer Degrees:
B.S.
in Civil Engineering, University of California 1947.
Professional Experience:
Employed at PGandE since 1947.
1963 -
Supervising Civil Engineer for Civil-Structural Design.
1971-1973 - Chief Civil Engineer.
Major projects in which he has participated include Cresta Powerhouse; San Mateo 230 kv Tower Line Crossing; Pit No. 4 Powerhoase; Units 5, 6& 7, Pittsburg Pcwer Plant; all of the Geysers Power Plant Units; Units 3 & 4, Morro Bay Power Plant: Units 6 & 7, Centra Costa Power Plant; Unit No. 3, Potrero Power Plant; Units 6 & 7, Moss La,nding Power Plant; and Units 1 _ 2, Diablo Canyon Nuclear Pcwer Plant.
Mr. Bettinger is chairman of the American Nuclear Society Committee ANS 2 on site evaluation.
Es is a member of the American Society of Civil Engineers. Task Cc==ittee on Nuclear Standards and served as a member of the joint American Cen-crete Institute--American Society of Mechanical Engineers Code Cemmittee which produced Division 2 of Section III of the ASME Code for Concrete for Nuclear Service.
..__a
-UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.-
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS I
l Name:
James C. Carroll Supervising Engineer, Title or Position:
Department of Steam Generation Degrees: Bachelor of Science Degree in Chemical Engineering 1952, University of California, 2erkeley.
Completed graduate level courses relating to nuclear cower technology.
Professional Experience:
Continuously employed since 1952 in the Company's Department of Steam Generation.
Assigned to the startup of Vallecitos boiling water reactor in 1957 Subsequent experience has involved the startup of the Dresden Nuclear Pcwer Station of Commonwealth Edison and startup of PGandE's Humboldt Bay nuclear unit.
Participacion in PGandE's Bodega Bay, Mendocino, Diabic Canyon and Stanislaus projects.
Member American Nuclear Society and have been actively involved in the Sccietl's standard writing activities relating to nuclear power plant operations.
Member and past chairman of Edison Electric Institute Nuclear Power Plant Design & Cperations Task Force, presdntly called Nuclear Pcwer Subecmmittee.
UNITED STATES OC' AMERICA NUCLEAR REGULATORY COMMISSION BEFORE TI!E ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
}
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC' COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units.No. 1 and 2)
)
RESUME OF QUT.LIFICATIONS FOR SAFETY HEARINGS Name:
ne: as :r. Craoferd Title or Position:
Mechanien1 Eneineer Degrees:
Bachelor of Science. Mechanical Enoineering, University 'cf California 1971, 1 year pest graduate werk, University cf California a
ProfeOSional E%pericnce:
Centinuously employed by cccpany since 1371, starting.
as a Designer in the Design Drafting Departnent and transferring to Mechanical and Nuclear Engineering in 1972. Werked en Diatic Canyon Nuclear Power Plant since 1971 dcing design, specificatien, and testing of instrumentatien systems and ccmpenents. Registered Mechanical Engineer,, State of~ California. Registered Centrol.5ystens Engineer, State cf California. Me:ter, nstrunent Society of Anerica.
b i
r i
t.NITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE T!!E ATCMIC SAFETY AND LICENSING ECARD
^
In the Matter of
)
}
Docket Nos. S0-27S 0.L.
PACIFIC CAS AND ELECTRIC COMPANY
)
S0-323 0.L.
(Diablo Canyon Nuclear Power
}
)
Plant, Units No. 1 and 2)
}
RESUME OF QUALIFICATIONS.
FOR SAFETY HEARINGS Name:
Bryan A. Dettman Title or Position:
Security Supervisor Degrees:
B.A. Police Administration,-Sacramento State University, Sacramento, CA M.A. Public Administration, Golden Gate Unviersity, San Francisco, CA Professional Experience:
1.
Walnut Creek Calif. Police Dept. - 1967 Patrolman, Dectective, Sergeant, investigau ve vivision w aanuer.
2.
Bay Area ? acid ransit District Police - 1971 Police Lieutenant, Bureau Cormiancer.
3.
PGandE - ?!uclear Plant Security - 1975 to cresent.
Humboldt Bay Power Plant ano Diaolo t.anyon rower riant, securuy aggervisor.
,4. 1974 - Bechtel Coro. - Consultant on Af roort Security - Honolulu International Airport.
NOTE: As part of 'lo. 3 above, have visited and ooserved security programs at i
the folicwing nuclear plants:
1.
Browns Ferry 2.
Zion
- 3..Donaid C. Cook A.
Seabrook 5.
Rancho Seco 6.
San Onofre O
UNITED STATES-OF 1.MERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
}
}
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
James T.
Doudiet Title or Position:
Treasurer Degrees:
City College of San Francisco, A.A.
1965 University of California (Berkeley), B.S. Mechanical Engineering, 1967 University of California (Berkeley),
M.3.A. Finance 1969 Profescional Experience:
1966 Pacific Gas and Electric Company; Engineering Trainee, Steam Generation; Econcmics & Statistics (part-time) 1969 - Financial Analyst 1971 - Manacer of Financial Planning and Analysis 1974 (Jan.) - Assistant Treasurer and Manager or Einanclai Planning and Analysis 1926 (Jan.
- Treasurer
_M"--
9 l
T w
UNITED STATCS OF A1 ERICA llUCLCAlt REGULATORY col 1P.ICSIO!1 DEFORC Tl!P. A'TGliTC SAFET'l At1D LICE!! SING BOARD In the !!atter of
)
)
Docket Nos. 50-275 O.L.
PACIFIC GAS AND CLECTRIC CCl:PANY
)
50-323 0.L.
)'
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
.RESUI!E OP OUALIFICATIC:;S FOR SAFETY !! EARINGS llame :
Vincent J.*Chio Titic or Position:
Senior Civil Eneinen Dcgrocs-Bachelor of Science. t'niversity of c3H formin 1o50 - conti ui se Educationcoursesandorofessionalconferencesrelatehtostructural
'nalvsis, design and croject management.
a Professional E):perience:
continuous 1v emnleved since 1959 in the cc~'an e's Engineerin'g Decartment with increasing levels of resconsib'ility for i
structural design of Fossil and :uclear fuelad power plants. Invcived w15h structural design coordination, supervision, and review for the Diablo Canyon Nuclear Power Plant structures since 1970. Registered Civil Engineer, California. Membpr.Americ'an Society of Civil Engineers.
O I
b f
i
(
i l
,.~,m.
.,r
._ _=__
O
~
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos.- 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
4 Plant, Units No. 1 and 2)
)
i s
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
John M. Giscion Title or Position:
Maaior Pewer Production Encineer Degrees:
B. S '. - Mechanical Encineerine, University of Nevada, 1961.
4 Professional Experience:
Registered Nuclear Engineer -
California Diablo Canyon Plant Staff - Power Production /
Senior Power Production Engineer - Pacific Gas and Electric Company, 9 years.
Plant Systems Engineer j
Westinghouse Electric Corporation, Naval Reactors l
Facility, 16 months.
Power Production Engineer on j
Humboldt Bay Power Plant Staff, Pacific Gas and Electric Company, 2 years.
l r
~ _ _ _. _.,...
e UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS 4
Name:
H. Jamea,Gormiv Title or Position:
Supervising Mechanical Encineer Degrees:
B. A.
Physics, San Francisco State (1960)
M.S. Mechanical Engineeringr San Jose State-(1966)
Professional' Experience:
Registered Mechanical & Nuclear Engineer, California.
Employed with PGandE 23 years.
Senior Mechanical Engineer. 1968-1976.
Supervising Mechanical Engineer, 1977.
For the past five years, I have been the' Chief Mechan'ical and Nuclear Engineer assigned to the Diablo Canyon Project.
i k
= _ _..
Ut!ITCD STATCS OF A!!CllICA 110CLCAlt 11CGULATO;'.Y COMP.ISSIO:1 BCPORC T1!C ATO:iTC SAPCTY At:0 LICF. : sit:G P.CAllD J
In the !!atter of
)
~
)
Doc):et Moc. 50-275 0.L.
PACIFIC CAS A!!D CLCCTRIC CO: IPA!!Y
)
50-323 0.L.
)*
(Diablo-Canyon Nuclear Power
)
P3 ant, Units No. 1 and 2)
)
RESUMC OF QUALIFICATIO:IS FOR SAFETY llEARIt:GS
)
llame:
Stanlev A. Manusiak t
Title or Position:
Civil Engineer Degrees:
Graduated from Cracow Technical t'niversitv in Poland with* 3SCE (1953) and MSCE (1955) najoring in St.ructures. Centinuing education courses andprofessionalconferencesrelatedtostructuralmechanics, dynamic l
and seismic analysis, design of r.uclear pcuer structures.
, Profeccional Experience:
Twenty-fivs years of structural engineerine er.cerience incfudin: 16 vears of e :perience related to secs = and nuclear gewer plant design with Pacific Cas and Electric Ccapany. Also:
One year with T.aiser Engineers in Oakland. California.
(design of cemene plant structures).
Two years at Penns.ylvanid Gisss Send Corporatien,*..*est Virginia.
(mineral processing facilitids).
Five years at Ministry of Construction Materials in Poland.
(design of cement pl nt stru.tures).
P.E. registered in California (Civil' Engineer and Structural Engineer) and West Virginia (Structural Engineer).
Member of ASCE.
l e
4
,--.-,c-w n,
w-,,
-r p.
n--,
n r.
UNITED STATES OF M! ERICA NUCLEAR REGULATORY CC:.NISSION BEFORE THE ATO!!IC SAFETY AND LICENSI'NG BCARD In the Matter of
)
)
Docket l'oc. 50-275 0.E.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Pouer
)
Plant, Units No.1 and 2)
)
RESUME OF QUALIFIC.\\TIONS FOR SAFETY HEARINGS Name:
John F.
Helms Title or Position:
Manager, Financial Planning and Analysis Degrees:
University of Washincton, B.A. Business Adminstf3*ian. loc:
University of California (Berkelev),
M.B.A.
1960 Professional Experience: 1960 IBM Corporation, Oakland, Sales Rec.
1962 General Electric Comoanv, San Jose, Financial Management Training Program 1966 Memorex Corporation, Santa Clara. Senior Svste.s Analys:
1961 Pacific Gas Ond Electric Company, San Francisco, Financial Analyst a976
- Manager of Einancial Planning and Analysis 6
e e
p e
e e
G
,o o
y-
~
e
-y
-m-e g
,7-
UNITED STATCS Or *MERICA
)
)
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo' Canyon Nuclear Power
)
Plant, Units l'o.1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFCTY UZAR.!NGS Name:
Julius Erich Herbst Title or Position:
Encineer Degrecs:
Incenieur fuer Elek.trotechnik.
(Electrical Engineer)
Ingenieur-Schule-Polytechnikum Giessen Germany (1950).
Professicnal E::perience:
'1950-59 Lahneye'r Frankfurt, Germany, Surveying and DesLqn of Trans=Ession Lines 1959-61 Western Knapp Engineering Co.
San Francisco Design cf Or Seneficiaticn Plants 1
1961-Present PGhE Design of Transmission and Distribution Substations (7 years)
Cesign for Steam Pcwer Plants (10 yearsl O
=
UNITED STATES CF AtERICA NUCLEAR RECTJLATCRY CO.2.IISSICN BETODE
- pre ATOJIC SAFETV AND EICETST'IG 90ACD In the Matter of
)
)
Docket Nos. 50-275 C.L.
PACIFIC GAS A'D ELECTRIC CC.t?AlIY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
neeC'.<=. a L+.Lr : r. u-.:..=s~,e v.
FCR SAFEZY EEA?.DIOS Nane:
John 3. '3cch ritle er ?csitien:
F m 'ect Enrineer Degrees:
?S 'lechanical Engineer #ne. Un# rersit-r ef !!she. Ic50
-Grsduate Stut
" C. ?erkeley Cc11ere f Enrinserinr.1C61 - 1062 Professional E.rperience:
Peristerad Mechanie91 D r#naer, Sts a of Califonia
?ard et= red "ueleer 7.rf neer. Stste of Calif --is 7 ule r=d b r ?GarlE since 105?. Tr er'enee es f0lle is-Ic53 - 1061
?cwer Finnt Enr#near et ?cn.ra C sta =r.d Pi.tsturr Power Plants. Start-up Engineer at Pitts:urgh ?crer
?lann.
1962 - 1969 "echanical P gineer. Ferf:rned nechanical design for f:ssil and nuclear prcJeces.
i 1970 - 1973 Mechanical Engineer. Perferned pre!#
=-y design and licensing for Mendccino ::uelear ?:~:Je t.
June 1973 -
Senior Mechanical Engineer. Licensing Engineer f:r Janua:/ 1977 the Diablo Canyon PrcJect.
l Janua:/1977 -
Project Engineer for the Diabic Cany n FrcJeet.
Present t
r t
l.
I I
=
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1.and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Ross M.
Laverty Title or Position:
Senior Mechanical Engineer Degrees:
Bachelor of Science Degree in Mechanical Engineering from College of Engineering, University of California, Berkeley 1954 Professional Experience:
Continuously employed in the Comoany's Mechanical and Nuclear Encineerine Department since 1957.
Involved in the design of mechanical systems and cemec-nents for fossil and geothermal power plants.. Presently
. responsible for seeing that the design of mechanical components and systems which are a part of or related to the nuclear steam supply system meet all the require-ments placed on them at the Diablo Canyon Project.
Member American Society of Mechanical Inqineers.
Registered Professional Engineers in California in both the fields of Mechanical Engineering and of Nuclear Engineering.
n.
e,.,
c e
,e m
U!IITED STATCS OF A:CRACA NUCLEAR REGULATORY CO!1MISSIO:1 BCPORC Tl!C 10!iTC SAFETY A!!D LICC:: sit!G BOARD In the Matter of
)
)
Docket Nos. 50-275 O.L.
PACIFIC GAS AND I?LE. aIC COMPANY
)
50-323 0.L.
)^
~
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIO:1S FOR SitPETY HEARINGS Name:
Mine E. ree
~
Title or Position:
c5,m v,g-n.y AA n grne_-ar-hitectural Eneineerine **echnolopt Degrees:
e City Collece of Stn Francisco 1961 BSCE, Heald Engineering College 1972 ProfcSSional Experience:
All with Pacific Gas & Electric Company
,orse_3o d e 73. na s.-- naa - Dr9frine penartment-orecared desien calculations & drawines for cover plant facilities.
L971-1972: Siting Deoartment-oerformed sit'e studies and orcoared olent layouts for orcspective new sites.
1972-present: Civil Enginee'r, Civil Engineering Department In Charge of:
- 1) The design of the circulating water system and plant utilities for Diablo Canyon Pr: ject.
- 2) The design of equipment foundations, under-groung piping syste=s and recentica ponds of the vaste treat:acnt systems at ten power plants.
6
~ -..
e-.
- f..
UNITCD STATCS OF A:1CRICA NUCLCAR RCGULATCnY col 1MISSIO:1 BEFORE T!!C ATO!!IC SAFETY A!!D LICE!! SING DOARD In the Matter of
)
)
Docket Nos. 50-275 0.L.
PACIFIC GAS AND CLCCTRIC CO:1PANY
)
50-323 0.L.
)'
(Diablo Canyon Nuclear Power
)
Plant, Units !!o. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY !!CARINGS Name:
Chung M. Li Title or Position:
Civil Engineer Dogrees:
Bachelor of Science degree - 1953, National Taiwan University, Taiwan, China Master of Science degree - 1959, University of Tennessee, Tennessee Professional Experience:
1968 - Prese*nt Pacific Cas and Electric Co.. San Francisco CA Diablo Canyon Nuclear Power Plants 1966'- 1968 C. F. Braun, Alhambra, CA Refinery 1964 - 1966 3echtsl Corporatient, San Francisco, CA Nuclear Po'ver Plant (Tarapur, India project) 1959 - 1964 Rust Engineering Co., Bir-ingham, AL Diversified industrial building (steel mills, chemical plants, paper mills).
1958 - 1959 University of Tennessee Part-time job chile studying for M.S.; verked for Professor Walker 1953 - 1957-Silos, harbor work, etc.
Taiwan, Q ina 7
en,-
i-
,--,w-.,
~
,y-----. _,., -,.
,_s-
,---.,,.--w,
,,<mt
.n
~
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canycn Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
John A.
McLaughlin Title or Position:
Senior Civil Engineer Degrees:
Bachelor of Science Degree in Civil Engineering, Healds Engineering College of San Francisco 1957 Profassional Experience:
Twenty-one years of engineering in Power Plant Site development, yard utilit-ies, and cooling water design.
My experience in nuclear power began in 1967 when I was assigned to the Diablo Canyon project and have devoted essentially half my time to the project.
Since 1974, I have been involved in the nuclear standards effort and am currently in four work. groups under sub-5 committee ANS-2, Site Evaluation, of the American Nuclear Society Standards Committee.
I am a member of the American Society of Civil Engineers and am currently chairman of the local ASCE Section's technical group on power and energy.
9 E
M r-,
--n n
.q
UNITED STATCS OP AMcnIcA NUCLEAR REGULATORY CCUMISSION BEFORE TUC ATC1IC SAFETY AUD LICENSING BOARD In the Matter of
)
} O.L.
PACIFIC GAS A!!D ELECTRIC COMPANY
.)
50-324 0.L.
(Diablo Canyon ::uclear Power Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIC::S FOR SAFCTY ::EAn;;;gs Name:
Alfred W. Medcalf Title or Position:
Senior Steam Generation Engineer Degrees:
B.E.E., University of Louisville, 1956 M.S., Physics, University of Louisville, 1961 a y, unnery Orficer Profecsional Z::Pericnce-and Instructor 1960-1964 - Pile Physicist, General Electric Company
Richland, Washingten
_1964-1966 - Nuclear Physicist, USAEC, Berkeley, Ca#--,4=
1966-1970 - Shift Supervisc, LFTR, UniversityofCaih$rhla, m:vermore, Caliternia i
1971-Present - Steam Generation Engineer, Electric Ocerations' Pacific Gas and Electric Company e
I s
e o
e G
- ~, -, -
,--m,
UNITCD STATCS OC AMCnICA NUCLEAR REGULATORY CC;;HIUSION GEFORE TIIE ATOMIC SACCTY AUD LICENSING BCARD In the Matter of
)
}
Dochet Nos. 50-275 O L PACIFIC GAS AMD ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units t o.1 and 2)
).
RCSUNE OF QUALIFICATIONS FOR SAFOTY U3ARINGS Name:
Donald Nielsen Title or Position:
Senior Electrical Engineer Degrees:
B.S.,
U.C. Berkeley, Electrical Engineering f
Profecsional Experience:
l.
Substation Engineer - PGandE, San Joaquin Division 2.
Electrical Engineer - FGandE, General Office 3.
Senior Electrical Engineer - General Office General Office experience was in the field of electrical desica of metrc'politan substations and thermal pcwer plants, including nuclear and fossil fueled.
Aisc had experience en distribution engineering in distribution equipment speci:1ca-tions and tests.
I am a registered electrical engineer in the State of California.
e t
d k
p,
-r
~
~.
UNITCD STATUS OF A:CRICA NUCLEAlt REGULATOl',Y COMMICSION I1CFORE T!!C ATCl;IC SAFET'I A!!D LICr.:: SING !! CARD In the 14atter of
)
)
Docket Nos. 50-275 O.L.
PACIFIC GAS AND CLECTRIC C0!!PANY
)
~50-323 0.L.
)^
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
~
-RESUME OF QUALIFICATIONS FOR SAFETY llCARINGS Name:
Oscar A. Rocha" Title or Position:
Civil Engineer Degrees:
BSCE,'!ational University of Nicaragua: Registered Profes'ional Engineer, s
California; member of.berican Society of Civil Engineers; =e=ber of American Cencrete Institute Cc==ittee 307.
Professional Experience:
Fif teen vears of exnerience in the desi2n of tanks.
stacks. ducts and utilities for Fossil and Nuclear Power Pla'nts for~
Pacific Gas and Electric Connanv.
9 O
O e
C-UNITCD STATES OF A". ERICA NUCLSAR REGULATORY COI:MISSICN DEFCRE T!!E ATOl!IC SA."ET*t A:iD LICENSING SOARD
-In the Matter of
)
l
)
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
, )
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No.1 and 2)
)
RESUME OF CUALIFICATIONS FOR SAFCTY USARINGS Name:
James David Shiffer Title or Position:
Power Plant Engineer (Diablo Canyon Power Plant)
Degrecs:
B.S., Chemical Encineerine, Stanford -(1960)
M.S., Nuclear Enoineerine, Stanford (1961)
Prof acsiona.1 E:tperiance:
Registered Engineer (California) in Mechanical and Nuclear Engineering 1962-1970 - Staff Nuclear Engineer at Humboldt Bay Pcwe; Plant 1970-Present - Power Plant Engineer at Diablo Canyon Pcwer Plann O
e a
e G
l..
UNITCD STATUS OF A: CRICA HUCLCAlt RCCULATCn? CC:!".ICSIO:t BEFORE T!!E ATO!!IC SAFETY A::D LICE:: SING BOARD In the !!atter of.
)
)
' Docket Noc. 50-275 0.L.
~
PACIFIC GAS AND ELECTRIC CO!!PI.MY
)
50-323 0.L.
)
4 (Diablo Canyon Muclear Potter
)
Plant, Units No. 1 and 2)
)
~
RESU:!C OF QUALIFICATIC: S FOR SAFETY iiEARINGS Name:
Igor Sokoloff a
Title or Position:
Civil Engineer 1-Degrees:
Bachelor of Science Degree, Heald Entineering College. 1968 continuing education courses related to analysis and design of structures.
' Professional Experience:
Continuousiv encloved since 1969 in the Coreanv's Engineering? Department with responsibility for analysis and' desi::n of Auxiliary 3uildin; of the Diabic Cany:n ':ucient Power Plant. T.cgistered Civil and Nuclear Engineer, California; neeber of American Society of Civil Engineers; American !iuclear Society.
9 g
+
I 6
1 1
e l
f I
.i me p
-qw
+ + -,
-p
,3m.
yq-
-.m,-
,w-+
y-
,-r
--r-- -, -
r
-w
e 1
UNITED STATCS OF AMERICA NUCLEAR REGULATORY CO:: MISSION BEFORE T!!E ATO1IC SAFETY AND LICENSING 3 CARD In the Matter of
)
)
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME CF QUALIFICATIONS FOR SAFOTY.:SARINGS Name:
Steven E. Traisman Title or Position:
Mechanical Engineer Degrees:
B.S., Engineering Mechanics, University of Wisconsin, 1969 M.S., Engineering Mechanics, University of Wisconsin, 1969 M.S., Environmental Engineering, John Hopkins University, 1974 Profacsional Experience:
Registered Professional Engineer - Calif., Wis.
1971-1974 - Instructor, U.S. Naval Nuclear Power School 1975-Present - Mechanical Engineer, PGandE.
Involved in
. fire protection for Humboldt Bay Power Plant 43 and Diablo Canyon from 1976 to the present.
n e
e
UNITED STATES OP AMERICA NUCLEAR REGULATORY CCI; MISSION BEFORE T!!E ATOMIC SAFETY AUD LICENSING BOARD In the Pattar of
)
)
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Thomas G. de Uriarte Title or Position:
Senior Engineer Dagrees:
B.S.
Civil Eneineerine, U.C.
Berkeley, 1967 Professional Civil Engineer Professional cuality Engineer Profeccional E::perience':
1967-Present - PGandE
__4-1/2 years - General Construction (3 years - Pittsburg Power Plant 47) 7 years - Cuality Assurance (Primarily related to Diablo Canyon)
O 4
9 e
e e
n m
e UNITED STATES OF AMERIFA NUCLOAR REGULATORY COMMISSION GEFORE TIIE ATCMIC SAFFTY AND LICE" SING BOARD In the Matter of
)
)
Docket Nos. 50-275 0.L.
PACIFIC GAS A"D. ELECTRIC CCMPANY
)
50-323 0.L.
)
(Diablo Canyon "uclear Power
)
Plant, Units "o. 1 and 2)
)
+
RESUME OF QUALIFICATICMS FOR SAFETY USARIUGS I
Name.
Michael V. Williamson l
. Title or Position:
Civil Engineer (Licensing Engineer for Diablo Canyon) 19'70, California State University, Los Angeles, Degrecs:
B.S.,
Engineering i
I 1970-Present
- Registerec Civil Engineer, Profeccional E::perience:
1970-1972 -
Pacific Gas'and Electric Company Junior Engineering Designer working on structural desien for Diablo 1972-Present
- Various assignments, IncAucing Aeacccan-Muclear Prcject, Stanislaus Nuclear Pro]ect anc DiacAo canyon.
D;acAo canyon ang;neef~
since February 1977.
g Titles and Chronolocy:
I July 1970 - Se'ptember 1972 - Junior Engineering Designer 1
I Septenber 1972 - Octccer 1973 - Engineer l
October 1973 - Presen: - Civil Engineer i
e 6
9 e
e-e, UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
. Docket Hos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Russell P. '41schew Title or Position: Director of Quality Assurance Degrees:
Ph.D.
Vanderbilt Universitv 1958 M.S.
North Dakota State University 1952 B.S.
North Dakota State University 1951 Professional Experience:
1976 - Present: PGandE Director, Cuality Assurance 1970 - 1976: President. Nuclear Audie and Testing Co. and vice President, E. R. Johnson Assoc.. Inc., 'lianna. vir2 inia 1967 - 1970:
Director, Division of Nuclear Material Safetuards.
U. S. Atortic Energy Ceccission 1965 - 1967:
Assistant General Manager, Nuclear Fuel Services, Rockville, Maryland and ' Jest Valley, New York 1963 - 1965:
Supervisor, Nuclear Division, Martin Mariatta Corp.,
3altimore, Maryland 19'61 - 1963: Senior Research Chemis't, Callery Che=ical Co., Callery, PA 1952 - 1961:
Group' Leader, Oak Ridge National Laboratory, Oak Ridge, TN (Scholastic Leave of. Absence 1956 - 1958) b r
r
~..
o UNITED STATES OF M1 ERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Robert Allyn Young Title or Position:
Electrical Engineer Degrees:
Bachelor Science, Electrical Engineering, University of California 19.61 Professional Experience:
5 1/2 years Industrial Control Manufac-turing; 2 years Power Plant & Mining Facilities Design i
(Bechter Corp. ) ; 9 1/2 years Design Engineering Diablo Canyon (PGandE); Registered Professional Engineer (California No. 7102) in 1969.
~
l l
-w - --
al- - w w,
. www=as, y=
www-m - w w sw w w - -= - -
l l
UNITED STATES OF~ AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matcer of
)
)
PACIFIC GAS AND ELECTRIC CCMPANY
)
Docket Nos. 50-275 O.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Norman L.
Ziomek Name:
Title or Position:
Mechanical Engineer Degrees:
Bachelor of Mechanical Engineering, University of Santa Clara 1960 Professional Experience:
Continuousiv emoloved in the Comeanv's Mechanical and Nuclear Encineerine Decartment since 1969.
Involved' in systems and ecuipment ancineerinc for Diablo Canyon Power Plant mechanical systems.
Precared and directed conceptual and final designs, engineering calculations, specifications, and administered centracts with ecuipment suppliers.
Assistant to the project engineer for planning, scheduling and coordinating engineering and design for future nuclear, generating plants.
Professional Mechanical Engineer, State of California.
v -
,s_
,y
,e--
g-w-
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD' In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canycn Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Thomas C. Esselman Manager, Support Structures Design, Title or Position:
Equipment Engineering for Westinghouse Degrees:
B.S. Case Western Reserve University, Mechanical Engineering M.S. Case Western Reserve University, Mechanical Engineering Ph.D. Case Western Reserve University, Mechanical Engineering Professional Experience:
In my current position, I am responsible for the design and analysis of Class I ccmponent supports to withstand postulated seismic ahd blowdown conditions.
My duties also include the design, analysis, and development of criteria for equipment and piping supplied by Westinghouse to assure its capability to withstand normal operating ccnditions and abnormal conditions such as earthquake and postulated pipe ruptures.
During the past five years, I have been involved with studies and analyses of the seismic and blowdown qualification of Diablo Canyon.
I have had lead responsibility for the qualification of all equipmen supplied by Westinghouse, which includes piping, components, and auxiliary and electrical equipment.
I am a member of the ASME and have served as a consultant to a task force investigating ASME faulted condition limits.
I have also served with the ANSI-N45 Ccmmittee as a task force member in the preparst on of a methodology for assuring pump operability.
w UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of ~
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. I and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Wilmer C.
Gangloff Title or Position: Project Manager for Westinghouse Degrees:
B.S.
in Physics, Ohio State University 1964 Professional experience: During my employment with Westinghcuse, I have held positions of responsibility in the areas of reliability analysis of control and protection systems
' performance for various postulated normal and accident conditions.
I have also had lead responsibility for reviewing conformance of safety and licensing standards in the areas of control.and electrical systems, core designs, and postulated accidents.
Prior to my current position, I was one of those responsible for the devel-opment of safety criteria and standards for Westinghouse i
pressurized water reactor plants.
l e+m ee,-
y
, - - + -
-.-py 9
y -
p-,
c.
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION-BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Chi-Win Lin Title or Position:
Fellow Engineer for Westinghouse Degrees:
B.S., Civil Engineering, Taiwan Proc. Cheng-Kunc University AsoA M.S.,
Engineering Mechanics & Sciences, University of Florida i,o, Ph.D., Engineering Mechanics & Sciences, Georgia Institute
- Ci recanology usoo Professional Experience:
I joined Westinghouse Electric Corporation in October 1969 as a senior engineer in the Auxiliary Equipment group of the Pressurized Water Reactor Systems
~
Division.
My responsibility was a. lead engineer respcn-sible for the development of the methods and the analysis of the' auxiliary mechanical equipment.
In February 1974, I was promoted to Fellow Engineer and working for the Structural Technology group in the same Division.
I was i
responsible for the development of the seismic methods and criteria for systems and components, and was responsible for the auxiliary mechanical equipment analysis for special projects.
On October 1,'1978, I was transferred to the Plant Structural Engineering group and assumed the present responsibility.
.--y y
4 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD i
In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALI?ICATIONS FOR SAFETY HEARINGS Name:
Bruce A.
Bolt Title or Position:
Prosessor of Seismology Degrees:
Ph.D. University of Sydney, Aust. 1959 D.Sc. University of Sydney,. Aust. 1972 Professional Experience:
Consultine Board for Earthcuake Analvsis, Dept. of Water Resources 1967 to cresent: Veterans Administration, Earthcuake and W_nd Forces Committee 1971-1975; California Seismic Safety Commission 1979 to present; Member Office of Emergency Sorvices Advisory Panel on Earthquake Prediction 1976- ; Chairman Panel on~ Seismographic Networks, National Academy of Sciences 1978; Member National Academy of Engineering; Regisrered Geologist and Geophysicist (California).,
4
,w
- - - -,,, ~ -. - + ~, -.. - -
a.
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC 57EETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. I and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Dr.
C.
Allin Cornell Consultant and Prof. of Civil Engineering Title or Position:
M.I.T.,
Cambridge, MA.02139 Degrees:
A.B.. Architecture, 1960, Stanford University M.S. Civil Engineering, 1961, Stanford University Ph.D. Civil Engineering, 1964, Stanford University Professional Experience:
Research,. teaching and consulting-in earthquake engineering with special emphasis on proba-bilistic approaches to seismic hazard definitions.
Dr. Cornell has acted as consultant on seismic design criteria and risk analys:.s for several nuclear power plants in the U.S.,
on air-craf t crash risk analysis for nuclear power plants, on seismic risk analysis and ground motion for major dam projects, on wind-loading design specification..fer high buildings,, en probabilisric fire safety analysis; etc.
The consulting services were rendered to U.S.
government agencies, to utilities, to engineers / architects companies, and to special engineering consultant firms.
The book by J.R.
Benjamin and C.A. Cornell " Probability, l
Statistics and Decision for Civil Engineers", McGraw-I Hill Book Co., New York 1970, can be regarded as the standard text book n this field.
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of~
)
).
PACIFIC' GAS AND ELECTRIC COMPANY
- )
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
b, - ',
1
'l RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Richard H. Jahns s
6 Consultant (Prof. of Geology and Dean, School Title or Position:
of Earth Sciences, Stanford University)
Deg ees:
B.S/ Caltech, 1935; M.S. Northwestern, 1937; y
w '- -
Ph.D. Caltech, 1.943..All degrees in Geology.
4 s
s,,
i 3
Professional Experience:
Excerience in cetroloav, mineralocv, sg and economic, ancineerine, glacial, and structural
.s geology during past 42 years of work with U.S. Geclegiral d'
Survey and at Caltech, Penn State, and Stanford.
Much s
a< > of this experience was in California,', including several m
n m
- p' arts of the coastal region.
Publications cc= prise
-' several monographs and niore than 100, scientific papers.
Edited and contributed to " Geology of Southern California",
p J
g-(.
published in 1954 as Bulletin of 170 'of. California i
i w
Division of Mines.
,s S
N
-5 e 'ga T
3 O
s e
qt.
O-m 4
'-W s
.s.*,
}'
,J3.
w- - -. --
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD-In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos.- 50-275 0.L.
-)'
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Dr.
H.
Bolton Seed Professor of Civil Engineering, Geotechnical Title or Position:
Engineering, Department of Civil Engineering, University of California, Berkeley Degrees:
B.S. Kincs College, London University 1944 S.M.
Harvard University 1947 Ph.D. Kings College, London University 1948 Professional Experience:
Dr.
H.
Bolton Seed is a member of the faculty of the Department of Civil Engineering,.tniversity of California, Berkeley, since 1950 and has been engaged in research and instruction in soil mechanics, seismic ground motion, soil liquefaction under seismic excitation, soil-structure interaction analyses for seismic response, seismic design of large civil engineering structures, e::.
Dr. Seed has been Chairman of the Department of Civil Engineering, U.C. Berkeley, during 1965-1,971.
Dr. Seed has acted as consultant on soil mechanics and seismic design problems to:
U.S. Nuclear Regulatory Commission; Atomic Energy Organization of Iran; U.S. Army Corps of Engineers; U.S. Bureau cf Reclamation; U.S.
I Department of the Interior; U.S. Geological Survey; U.S.
Navy; U.S. National Aeronautics and Space Division; State (contd)
.4 e
Professional Experience:
contd.
of California Department of Water Resources, Division of J
i Highways, Division of Mines and Geology; Pacific Gas and Electric Company; Los Angeles Department of Water and Power, Oak Ridge National Laboratory;. Westinghouse-Hanford Company, etc.
Dr. Seed is further acting as special consultant of solid mechanics and seismic design problems to several Engineers / Architects and Consulting Engineers Companies.
e b
?
v, -,.
a i
~
UNITCD STATCS OF AMERICA NUCLCAR REGULATORY COliMIOUION DEPORE T!!C ATCMTC SAFCTY AMD LICCl! SING ROARD In the !!atter of
}
)
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COliPANY
)
50-323 0.L.
).
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUMC OF QUALIFICATIC:1S FOR SAFETY iiEARING3 Narae:
Robert T.
Lawson Title or Position:
Executive Vice President Degrees:
3.
S.,
Civil Encineerine. University of Washincton, 1943
' Professional Experience:
lotR-5n - Dames & !! core-Junior Encineer to Project Encineer Marine Corps - Infantry Officer 1950 U.S.
1952 Dames & Moore - Various levels of increasing responsibility to Partner ia the S.F. office 19 6- Pres ent - Harding-Lcuse;.-Associates Er.ecutive Vice-Pret. dent, consulting engineer
~
4
4 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME CF QUALIFICATICNS FOR SAFETY HEARINGS Name:
John Lysmer Title or Position:
Professer of civil sneine.r+-e Degrees:
M.Sc., '"echnical Univers i t'r o f Da-Pa rk, toca Ph.D., University of 'tichican, 1965 Professional Experience:
1965-78 Professor of civi ? Enci-a.ri n e Univernty of California, Berkelev, and Censultant to numerous creanizatiens in the areas of soil dynamics and eartheuake encineerina.
1962-65 Fesearch Assistant and Lecturer Uni.versity of Michigan 1961-62 Instructor and Fasearch Ingineer University of Florida 1955-61 Civil Engineer Ove Arup and Partners j
I4ndon U.K. and Lagos, Nigeria 1954-55 Civil Engineer Preben Sch/nning, Cepenhagen, Denmark I
l
-p,e
e UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC 3AFETY AND LICENSING BOARD In the Matter of
)
}
Docket Nos.. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No.1 and 2)
)
RESUME OF QUALIFICATIONS FCR SAFETY HEARINGS Name:
Stewart it. Smith Title or Position:
ProfessorandC*iairman,CraduatePrograminCe5 physics n ersity of WasMngton, SeacLe, WA 6 Degrees:
1954 S.3. Coology and Geoohysics, Massachusetts Institute of Technology 1957 M.S Ceopiwsics, California Institute of Technolog -
1061 Ph.D Cecchysics and Mathematics, California Inst. of Tech.
Professional Experience:
Ceophysicist, Shell 011 Company 1954-1957 Assistant Prof. of Ceophysics, Caltech 1961-1964 Associate trot. o r oeo p ay nc.s. vai - c u..
.,,-..U'
, - s m, 4 -,,
e,-4._, g.< e., g Ja chington 1970-nresent p,c m,
r-sm-e-s.,-
,,1-,,,,
4.,,. 4.,o lo r,. Iq66-oresent Registered Professional Geophysic.tst, State of California
~.
.:_---.-~~.-
-r a*
l i
U!!ITCD STATCS OF AMCRICA NUCLCAR RCGULAToiFl COMMICSION BEFORC Tl!C ATOMIC SAFETY A!!D LICCl! SING BOARD In the !!atter of
}
)
Dochet 1:os. 50-275 0.L.
PACIFIC GisS AND ELCCTRIC COMPANY
)
50-323-0.L.
. )'
-(Diablo Canyon Nuclear Power
)
~
~
Plant, Units llo. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Takekazu Udaha Title or Position:. Manager, Soil Dynamics and Earthquake En'gineering Degrees:
Ph.D. Civil Encineerine (Earthquake Engineering)*,
U.C.,
Berkeley M.S.
Civil Engineering (Soil Mechanics),
U.C., S'erkeley B:S. Civil Engineering '(Soil Mechanics), Kyoto Univ.,' Japan
~
' Professional Experience:
Dr. Udaka has participated in the development and application of analytical procedures for the seismic analysi:.
of soil deposits, earth structures, and soil-structure systems.
He 'is the author or co-author of the finite element computer programs FLUSH, LUSH, TRIP and TRAVEL.
Dr. Udaka specializes in soil dynamics,.especially in the analysis of soil-structure interaction problems.
Representative projects he has worked on include:
traveli'ng wave seismic analysis of Fcrt Peck Cam, Montana; soil-structure interaction analyses for Fast Flu::
Testing Facility, Washington; soil-structure interaction analys:.
for South Texas Nuclear Project; seismic stability analyses of ccoling ponds at X24-X25' Nuclear Plant Site, Mississippi; soil-structure interaction studies fbr the General Electric Company Standard Nuclear Plant; site-dependent response spectra study for WPPSS-Hanford Nuclear Power Plant; pipeline displacerent study for Southwest Ocean Outfall Project', California (SWCOP);
soil-structure interaction studies of underground stcrage tanks at Diablo Canyon Nuclear Power Plant, California: Seismic, Qualification Studics for underground pipeline using triveling seismic waves at Diablo Canyon Nuclear Power Plant.
m. * = = +
=
=.
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos'. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)-
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
yown A.
91--.
Title or Position:
President, URS/Blume 1971-oresent Degrees:
S*inford University, Ph.D. S tructural/Earthauake Engineering, 1967 Stanford University, Encinser, Structural Engineering, 1935 Stanford Universitv, B.A. Civil Engineering, 1933 Professional Experience:
UFS / John A.
Blume & Associates, Engineers, San 4
Francisco, California, President and Director, 1971-oresent: John A. Blume & Associates, Engineers, President, 1957-1971; John A.
Blume, S tructural Engineer, Owner, 1945-1957 H. J.
Brunnier, San Francisco, California, Engineer in Charge of Design, 1940-1945 Standard Oil Company of California, San Francisco, Engineer, 1936-1940 State of California, Division of Highways, Engineer, 1935-1936 U.S. Coast and Geodetic Survey, Seismological Division, San Francisco, California,Research Engineer, 1934-1935
-,v
= -
-+
,-f
--%r-
-->w---,y,yi-ee
!--n--
John A. Blume 2-Stanford University, Stanford, California, Research-Assistant, 1933-1934 Dr. Blume participates in and directs special projects 4
and research operations for the firm.
He is an authority on earthquake engineering and structural dynamics and pioneered the development and application of.new concepts of seismic design and analysis ~.
He has served for several years as' principal' consultant for studies of structural response to underground nuclear explosions for the U.S. Department of Energy Nevada Operations Office.
He is also an active consultant on the earthquake aspects of nuclear power plant licensing, seismic criteria, and design for both the federal government and private industry.
He is an advisor to the national Science Foundation on research policy and earthquake engineering.
Dr.Blune was Chairman of the Management Conmittee for the design of all structures and site work for the S114-million Stanford Linear Accelerator Center.
The John A. Blume Earthquake Engineering Center-at Stanford University is named for htm.
n-
?? -.- -- -
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)-
Docket Nos. 50-275 0.L.
)
50-323'O.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATICNS FOR SAFETY HEARINGS Name:
ni34 7 o_
33,,,
4 Title or Position: Vice President, URS/ John A.
Blume & Associates, Engineers.
Degrees: ry n i. m r -4 *.r of Michican, Ph.D. Civil Encineerinc, 1967 University of Michigan, M.S.E. Civil Engineering, 1963 Guiarat University, India, B.E.
Civil Engineering, 1961 Professional Experience:
rg4-oors. sar Francisec, cpsyr-u-a n 1..-o e
- =ecc4,-oy.
e
-California, Vice President, 1977-present; Project Encineer. 1969-oresent; Structural Dvnamics Encineer, 1967-1969 University of Michigan, Department of Civil Engineering, Research Associate, 1963-1966 N.
N. Purandare, Consulting Engineer, Bombay, India, Assistant Design Engineer, 1961-1962 Dr. Jhaveri has extensive experience in structural engineering, including ecmputer-aided structural analyses, and soil-structure dynamics studies.
Projects i
a r
Dilip P. Jhaveri-. have included seismic' analyses of high-rise buildings, piping and equipment, buried structures, and other special structures.
He has worked on several projects involving both linear and -nonlinear dynamic analysis under earthquake loading.
Dr. Jhaveri has also been responsible in various capacities for seismic analyses of structures for nuclear power plants, including Kewaunee in Wisconsin, Indian Point Units 1 and 2 in New York, and Diablo Canyon in California.
He has provided technical consultation on all analyses involving very high
~
g-level seismic inputs for Diablo Canyon. EHe has also been in charge of a study to improve the seismic resistance capability of General Electric's BWR/6 Mark III standard
~
plant and a generic review of the seismic design adequacy of the High-Temperature Gas-Cooled Reactor core and internals performed for the U.S. Nuclear Regulatory Commission.
He has been in charge of soil-structure interaction research-conducted for the Electric Pcwer Research Institute and for I
the Pacific ~ Gas & Electric Company's Diablo'Canycn Nuclear Power Plant.
He has performed statistical analysis of ground motion records to observe the influence of local soil ccnditions and has been responsible for development of analytical techniques and cceputer programs for two-and three-dimensional static and dynamic analysis of -high-rise structures.
a a
Dilip P. Jhaveri Dr. Jhaferi has directed linear and nonlinear seismic analyses of. buried radioactive waste tanks and-other waste-processing facilities at the Savannah River Plant in South Carolina
.and the Hanford Atomic Reservation in Washington.
He has f
also been in charge of analysis and seismic design of several high-rise buildings such as the One Embarcadero Center office building and the Hyatt Regency Hotel in San Francisco and the Bonaventure Hotel in Los Angeles.
S e
I UNITED STATES OF AMERICA NUCLEAR :.EGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICE'ISING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear' Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Lincoln Edgar Malik Senior Engineer, URS/ John A. Blume &
Title or Position:
Associates, Engineers Degrees:
University of California, Berkeley, Ph.D. Civil engineering, 19/o Stanford University, Degree of Engineer, 1970 stan: ora University, M.o.
Giv11 Engineering, 19o9 University of California, Berkeley, B.S. Civil Engineering, aso4 Professional Experience:
URS/ John A.
Blume & Associates, Engineers, San Francisco, California, Senior Engineer,'1976-present University of California, Berkeley, Department of Civil Engineering, Research Assistant, 1971-1976 i
Sargent and Lundy Consulting Engineers, Chicago, Illinois, Design Engineer,. 1965-1968 Westenhoff and Novak Consulting Engineers, Chicago, :llinois, i
Design Engineer, 1964 i
4 e
e m*
O l
l
a Lincoln Edgar Malik -
Dr. Malik has worked on concrete and steel design of conventional and nuclear power plants.
He has been leader of the group responsible for designing the radiation waste building, service building, and turbine building of Quad Cities Nuclear Power Plant.
He has participated in the design of several buildings of the Kincaid Power Plant and in the seismic analyses of structures and in licensing meetings before the U.S. Nuclear Regulatory Commission staff for the Diablo Canyon Nuclear Power Plant.
Dr. Malik has also done research on the response of the Olive View Medical Center in Los Angeles to the 1971 San Fernando earthquake, performing static and dynamic computer analyses, and has investigated the contribution of floor systems to the dynamic characteristics of buildings, while working as a research assistant at the ';niversity of California.
,m
UNITED. STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC ~ SAFETY AND LICENSING BOARD In the Matter.of
')
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
David Williams Senior Research Engineer, URS/
Title or Position:
John A.
Blume & Associates, Engineers I
Degrees:
University of Canterbury, New Zealand, Ph.D. Structural /
cngineering, idet University of Canterbury, New Zealand, B.E.
(Honors) cav11 Engineering, asos Professional Experience:
CRS/ John A.
Blume & Associates, Encineers, San Francisco, California, Senior Research Encineer, 1977-oresent University of California, San Dieco, Censultant Associate, 1976-1977 University of California, Berkeley, Department of Civil Engineering and Earrhquake Engineering Research Center, Assistant Research Engineer, 1972-1976 Christchurch Technical Institute, New ealand, Departmen-of Civil Engineering, Lecturer, 1970-1971 University of Canterbury, New Zealand, Department of Structural Engineering, Teaching Assistant,- 1969-1971 i
+-
David Williams Dr. Williams has been~ responsible for management of a research effort to determine the effects of wind loading on high-rise buildings and to compare these with the effects of ground motion.
This has involved both experi-mental and analytical considerations and their correlation.
l Response predictions based on both deterministic-and nondeterministic analyses have been undertaken.
He has also been. responsible for evaluating the. response of existing structures to postulated future earthquakes.
His experience has included analysis and design of structural systems subjected to dynamic loads, including assessment of the reliability of fixed offshore platforms.
7 Dr. Williams has implemented the experimental phase of a comprehensive research project concerned with seismic response and design of modern highway bridges, a program sponsored by the U.S. Department of Transportation following i
the damaging San Fernando earthquake of 1971.
This inves-tigation has included a model study and detailed tests l
using a shaking table.
In addition to feasibility studies, l
design, organization,'and supervisien of the experimental l-program frcm its conceptual stage,'the project.has included linear ~and nonlinear theoretical response prediction and its correlation with measured response.
Dr. Williams:has also conducted analytical and experimental research related to seismic-resistant design of masenry structural systems and has served as a consultant in this field.
m.m.______,_____
O' e
UNITED STATES OF AMERICA
' NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICE'ISING BOARD
'In the Mattar of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
- Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATICNS FOR SAFETY HEARINGS Name:
Ahmad F.
Kabir Senior Engineer, URS/ John A. Blume Title or Position:
and Associates, Engineers Degrees:
University of California, Berkeley, Ph.D. Structural Engineering, isto University of Waterloo, Canada, M.A.Sc. Structural cagineering, Aa,v University of Engineering and Technology, Bangladesh, o.oc. Liv 1A sngineering, 13oo Professional Experience:
URS/7ohn A.
91eme c Asscciates. Encinaars. gan F-,ncisco, Senior Encineer, 1976-cresent University of California, Berkeley, Department of Civil Engineering, Research Assistant, 1971-1976 University of Waterloo, Ontario, Canada, Departncnt of Civil Engineering, Teaching Assistant, 1968-1970 University of Engineering and Technology, Dacca, Bangladesh, Department of Civil Engineering, Lecturer, 1965 Government of Pakistan, Department of Telegraph and Telephones, Dacca, Bangladesh, Consultant, 1967-1968 Cmarsons, Ltd., Dacca, Bangladesh, Assistant Engineer, 1967 i
w g
-e-V
Ahmad F.
Kabir 2-Dr. Kabir has worked on numerous structural design and analysia projects, including the prestressed concrete folded-plate roof of the multipurpose arena of Hong Kong University, the aerial superstructure of the Metropolitan Atlanta Rapid Transit Authority, a ramp bridge at the Taiwan airport,.the Djakarta sports pavillion in Indonesia, and the San Jose Auditorium.
He has also participated in the design of an offshore platform, industrial buildings, and several box girder bridges.
He has worked on seismic studies for the Diablo Canyon Nuclear Power Plant and participated at licensing meetings before the U.S. Nuclear-Regulatory Commission staff.
Other assignments include work on soil-structure interaction studies for the Electric Power Research Institute.
I Dr. Kabir has done research on the behavior of various types of reinforced concroce structures subjected to creep, shrinkage, temperature changes, and'other time-dependent effects while at the University of California, Berkeley.
c
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
~)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo' Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATICNS FOR SAFETY HEARINGS Name:
Andrew B.
cunnincham Senior Engineering Geologist, URS/
Title or Position: Jnhn A.
Blume and Associates, Engineers.
Degrees: University of California, Berkeley, M.A.
Geolocical Sciences, 1955 University of California, Berkelev, B.A.
Geological Sciences, 1951 Professional Experience:
J URS/ John A.
Blume & Associates, Engineers, San Francisco, California, Senior Engineering Geologist, 1967-present Harding Associates, Soil Mechanics Engineers, San Rafael, California, Engineering Geologist, 1963-1967 State of California, Department of Water-Resources, Engineer-ing Geologist, 1960-1963 4
Southern Pacific Cc pany, Western United States, Geologist, 1956-1960 3 ear Creek Mining Company, Utah, Geologist, 1955-1956 University of California, Berkeley, Teaching *and Research Assistant, 1954-1955 Anaconda Copper Mining Ccapany, Death Valley, California Mine Engineer, 1951-1953 l
L t
i I
Andrew B. Cunningham Mr. Cunningham is responsible for geologic and seismologic investigations and evaluations.
He has carried out studies for high-rise buildings, hospitals, industrial plants, nuclear facilities, and other structures at a variety of sites, including desert and offshore sites.
He is experienced in all phases of surface and subsurface geologic investigations and in such geophysical techniques as gravity, 4
magnetic, and seismic measurements.
He has investigated canal and~ tunnel alignments and dam sites for the California aqueduct system and has perforned investigations to determine dyna $1c soil properties at the sites of large commercial buildings such as One Embarcadero Center in San Francisco and high-rise buildings in Iran.
He is also an experienced mine' engineer and mineral exploration geologist.. Mr. Cunningham has-conducted geologic and seismic evaluation studies for nuclear waste treatment plants, waste storage sites, and other nuclear installations throughcut the United States and in various parts of the werld.
He has been in charge of geologic mapping, geophysical exploration, and other studies necessary to establish seismic criteria for the Fast Flux Test Facility at Hanford, Washington.
He has carried out seismic and geologic studies at the Diablo Canyon Nuclear Pcwer 4
Plant site in California; the proposed Verplanck Nuclear Pcwer Plant site in New York; and the U.S.
3-Andrew B. Cunningham Department of Energy Savannah River Plant, South Carolina, and the Oak Ridge and Hanford reservations.
Mr. Cunningham has made numerous presentations before both state and federal government organizations, including the Advisory Committee on Reactor Safeguards, and has participated in reviewing more than 20 preliminary safety analysis reports for nuclear power plants for the Division of Reactor Licensing oof the U.S. Atomic Energy Commission (succeeded by the Nuclear Regulatory Commission).
i
]
---,-e
..n
~, '
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD 4
In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
l RESUME OF QUALIFICATIONS FOR SAFETY EIARINGS 4
Name:
B.
(Chuck) Chakravartula PIPESD Marketing and Technical Representative Title or Position:
for URS/ John A.
Blume & Associates 4
Degrees:
University of California, Berkeley:
M.C.A. Business Administration, 1973.
University of California, Berkeley:
M.S.
Civil Engineering, 1970.
Indian Institute of Tecnnology, Madras, India:
B.
Tecn.
Civil Engineering, 1968 Professional Experience:
URS/ John A.
Blume i Associates, Engineers, San Francisco, California, PIPESD Marketing and-Technical Representative, 1977-present 2
EDS Nuclear, San Francisco, California, Senior Lead Engineer, 1973-1977 University of California, 3erkeley, Teaching Fellow, 1971-1973 University of California, Berkeley, Department of Civil.
Engineering, Graduate Research Assistant, 1963-1971 Mr. Chakravartula has extensive experience in piping analysis of nuclear power plants in technical and administrative capacities, including budgeting, planning and evaluating alternative projects, quality assurance i
B.
(Chuck) Chakravartula -
and documentation, computer programming applications, and client liaison.
As Marketing and Technical' Representative of the PIPESD piping analysis program (pipe structural and dynamic analysis), Mr. Chakravartula has been responsible for supervising.all program development and coordinating worldwide program marketing efforts.
His. duties have included revising the program for code compliance, conducting technical seminars, documenting and maintain-ing quality assurance for program revision, and client t
liaison.
Mr. Chakravartula has also been involved in the Hanger Design Review for Diablo Canyon Nuclear Power Plant, using PIPESD to determine the adequacy of the hanger'under the Mcsgri Spectra loads.
Mr. Chakravartula has participated in stress analysis of piping systems of nuclear power plants for Duke Power Company, with responsibilities in administration and supervisicn of the. engineering staff, production schedule, and cost con:rol data.
He has performed analysis in compliance with the provisions of ASME Boiler and Pressure Vessel Code for McGuire Nuclear Station, Units 1 and 2; Catawba Nuclear Power Plant, 3
Unit 1; and Ccenee Nuclear Power Plant, Unit 1.
The 9
.-r e * - -, e - -
B.
(Chuck) Chakravartula work has involved fatigue evaluation and stress reports - for. class 1 components, stress evaluation of class 2 and 3 components, and postulation of break locations for high' energy piping.
In addition, he has conducted analysis in accordance with ANSI B31.1 for the Tennessee Valley Authority at Sequoyah Nuclear Power Plant, Units 1 and 2, Watts Bar Power Plant, Units 1 and 2, involving analysis of pipe rupture, pipe whip, jet impingement, and develcpment of jet impingement screening criteria.
The project has also involved development and implementation of alternative analysis criteria for small diameter piping.
4
+
F 1
UNIT'ED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of'
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS
-FOR SAFETY ' HEARINGS Name:
Debabrata Ray Title or Position: Senior Engineer, URS/Blume & Associates Degrees: University of California, Berkeley:
Ph.D. Structural Engineering, is,4 sengal Engineering vo12ege, India:
M.E. Civil Engineering, 1967.
Bengal Engineering college, incia:
d.s.
Livia sagaaeerias, 1964.
Professional Experience:
URS/ John A.
Blume & Associates, Engineers, San Francisco, California, Project Engineer, 1976-present; Senior Engineer, 1975-University of California, Berkeley, Structural Engineering and Structural Mechanics D ivision, Assistant Research Engineer, 1974-1975; Research Assistant and Teaching Assistant, 1969-1974 Chemical and Metallurgical Design Company, Ltd., New Delhi, India, Structural Cesign Engineer, 1963 Metal Engineering and Treatment Company, Ltd., Calcutta, India, Structural Design Engineer, 1967-1968 Bridge & Roof Company, Ltd., Calcutta, India, Structural Designer, 1964-1965 t
v.
a Debabrata Ray.
Metal Engineering & Treatment Company, Ltd., Calcutta, It. 'ia, Structural Designer, 1964 Dr. Ray's experience with computer-aided engineering analysis has involved applications of numerical and computational methods.
As P roject Engineer for the PIPESD piping analysis program, he is responsible for developmental work, including incorporation of-new features and capabilities and modification of the program.
Dr. Ray is also. responsible for conducting seminars in the United States and Europe on. piping analysis and the American Society of. Mechanical Engineers (ASME) code in relation to PIPESD.
Most-recently, Dr. Ray has been responsible for the development of the PIPESD/ HEAT program, a thermal transient analyzer that determines temporal and spatial distribution of temperature in pipes for different fluid transient conditions and computes temperature gradients according to Section IV of the ASME Boiler and Pressure vessel Code.
The theory and computer code of PIPESD/ HEAT has been solely developed by Dr. Pay.
Both the PIPESD and PIPESD/ HEAT programs are marketed worldwide through the Control Data Corporation.
o Debabrata Ray.
Through his work on soil-structure interaction analysis for the Diablo Canyon Nuclear Power Plant near San Luis Obispo, California, Dr. Ray has provided testimony at public-hearings of.the Advisory Committee on Reactor Safety.
His work has involved the generation of effective response spectra for translation, torsion, and tilting through a filtering concept for general wave-scattering phenomena arising from the shape, geometry, and rigidity of the foundations.
He has been responsible for the three-dimensional finite-
. e element.eismic analysis of the Diablo Canyon intake 4 ructure, including hydrodynamic effects.
Dr. Ray has been instrumental in writirj the work plan for a soil-structure interaction study for the Electric Power Research Institute.- He.has also been responsible for the seismic analysis of nuclear-power-plant-related structures, including the Unit -1 Containment Building at the Indian Point Nuclear Pcwer Plant in New York.
Other projects have included analysis of buildings and their responses to the San Fernando, California, earthquake of February 1971; 3
evaluation of existing structures to postulated future i
earthquake exposure; and dynamic analysis of equipment i
E 4
-~
s % -
---v
}
- +
Debabrata Ray and other structures.
Dr. Ray has been involved with quasi-static and dynamic experimental' investigation of earthquake resistance. characteristics of inelastic beam-column subassemblages of multistoried steel frames for the Division of Structural Engineering and Structural Mechanics at the University of California, Berkeley.
His earliest experience
. includes four years of work as a structural ~ design engineer-in India, during which time he worked on severalprohects, such as the Ni-Co sulphide refinery plant-in Cuba and multicellular-shell-roof aircraft 5
hangars.
4 E
e
)
J y
B e
h g
I f
i
'l f
+
s l
p.
e
' I
~
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION
~
g
.BEFORE THE ATOMIC' SAFETY AND LICENSING BOARD In the Matter of
)
~
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
i
)
50-323 0.7 (Diablo Canyon Nuclear Power
-)
\\
Tiant, Units No. 1 and 2)
)
}~
m
'\\'
RESUME OF QUALIFICATIONS
~
FOR SAFETY HEARINGS i
Name:
David A.
Lanc s, s s' s
Title or. Position:
Proiect Manacer for URS/Blume L.
, 'N Degrees:
University of California, Berkeley, M.B.A.
Business s
L~
Administration, 1978, in progress d'
Un'iversity of California, Berkeley, M.S. Structural Engineering /Cynamias, 1967 1
University of California, Berkeley, B.S. Civil Engineering, 1966
/
Professional Experience:
1 o
i URS/ John A. Blume & As' socia'tes,sEngineers, San Francisco, 3
,, ~
California, Project Manager,'1975-present: Senior
't
^
i'
~
1967-1971 Engineer, 1971-1975: Engineer, w-k,\\
l
)
~
a,,
Mr. Lang has extensive experience in analysis and design of single and multiscory public and commercial structures, steel and concrete frames, and shear-i wall structures.
He has been responsible for the
!,.V
~
design of all above-grade structures of the planned y
s
- s,*I g'-
'n.
j N, Yerba Buena Center Redevelopment Project in San
'1 y ;-
Francisco and has served.as structural project N.
' engineer for the mcdification~and addition to the 40 x 80-Foot Wind Tunnel at Ames Research Center in
~'
f
- p,.
a s1.
U n.
?
+
w
e David A. Lang California.
His design projects have included a number of research and administrative buildings for Syntex Corporation in Palo Alto, warehouse facilities for the U.S. Navy at the Port of Guam, hospital facilities at Mather Air Force Base in California, and a parking garage for the Bunker Hill complex in Los Angeles.
Mr. lang has participated in the dynamic analysis of high-rise buildings in Las Vegas, Nevada, as part of the underground nuclear testing program for the United States Department of Znergy, which involved monitoring tests and conducting subsequent surveys to ascertain damage to structures.
He has performed dynamic seismic analyses of piping systems for various nuclear power plants, including the Dresden, Tsuruga, Diablo Canyon, and Oyster Creek plants.
He
~
has also analyzed piping systems and related structures for the nuclear Rocket Development Station in. Nevada.
He has served as project manager for the seismic evaluation of the Diablo Canyon Nuclear Power Plant and as project =anager for the seismic analysis of reactor and evaporator buildings at the Savannah River Plant for E.
I.odu Pont de Nemours and Company.
Mr. Lang has also been involved in structural dynamics and analysis of waste treatment and storage facilities
t David A. Lang 2-at the Hanford Atomic Reservation in Wasnington for the Atlantic Richfield Hanford Company and Vitro Engineering.
Mr. Lang has worked on the seismic analysis of a graphite stack for Douglas United Nuclear and a number of structures at Oak Ridge, Tennessee, for the Union Carbide Corporation and has participated in a study cf the effects of Union Carbide Corporation and has participated in a study of the effects of the San Fernando earthquake on various high-rise structures in Los Angeles.
O s
s 4
r-7,-
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME CF QUALIFICATIONS FOR SAFETY HEARINGS Name:
yn7.. o v43,,un,,
Senior Engineer, URS/ John A. Blume & Associates, Title or Position:
4 e.7
-mm.,
Degrees:
c.,, s..a n. 4.,,,, 4.., _ y a c 4.,4 3 4
e,7..
4 7 Sogy University of the Philliccines, B.S.
Civil Encineerine, 1964 r.
Professional Experience:
nec / Tcha s_. 41,m a e asenc4,*am. e ng4-oa-m.
e---c4e-o, caa cali*ornia, Senior encinaar.
Icio.c-= san
- John S.
Bolles & Associates. Architects and Encinears, San Francisco, California, Desien Encineer, 1967-1969 DCCD Engineering Corporation, Consulting Engineers, Makati, Rizal, Philippines, Cesign Engineer, 1964-1966 Philippine Prestressed Concrete Company, Marikina, Rizal, Philippines, Design Engineer, 1964 Mr. Villatuya is responsible for the seismic analysis of structures, equipment, and piping of nuclear plants, high-rise buildings, and other ccmplex structures.
. 4 Roger R. Villatuya For the Diablo Canyon Nuclear Power Plant, he has performed the dynamic seismic analysis of the containment structure (using the axisymmetric finite-element approach), the Auxiliary Building (including torsional modes of vibration),
and the Turbine Building, and has performed the seismic analysis of piping systems.
Mr. Villatuya has also been responsible for the dynamic seismic analysis of the reactor building at the Duane Arnold Energy Center and several buildings at Indian Point Nuclear Power Plant and for the analysis of piping systems for static and seismic loads at the Savannah River Plant and the General Electric Test Reactor.
4 At the Hanford Reservation, Washington, he has made a dynamic seismic analysis of the Purex Process Facility Building, using elastic and. nonlinear analyses procedures, and has made several seismic studies of underground waste storage tanks for dead, live, and thermal loads and earth-quake ground motions.
Mr. Villatuya has also studied damage I
effects of the 1971 San Fernando earthquake on office I
buildings in Southern California and has been involved in a a statistical study of earthquake spectra.
4 1
2
<-~v
~
c.-
y
~,
e.,-
-~m.
e UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
Cocket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No.1 and 2)
)
RESUME OF QUALIFICATICNS FOR SAFETY HEARINGS Name:
RALPH T.
YOK0YAMA Title or Position:
Principal Engineer, URS/Blume Degrees:
B. S., U. C. Be r'e l ev. 1951 Registration: Civil Encinear, State of California Structural Encineer, State of California Professional Experience:
25 years exoerlence in desien, consultation, seismic review and analvsis of all tvoes of structures includine highrise buildines. marine structures, and nuclear olants.
4 0
4 9
-g
-w-v'
a UNITED STATES OF AMERICA-NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In~the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Thomas C. Esselman Manager, Support Structures Design, Title or Position:
Equipment Engineering for Westinghouse Degrees:
B.S. Case Western Reserve University, Mechanical Engineering M.'S.
Case Western Reserve University, Mechanical Engineering Ph.D. Case Western Reserve University, Mechanical Engineerinc Professional Experience:
In my current position, I am responsible for the design and analysis of Class I component supports to withstand postulated seismic and blowdown conditions.
My duties also include the design, analysis, and development of criteria for equipment and piping supplied oy Westinghouse to assure its capability to withstand normal operating conditions and abnor=al conditions such as earthquake and postulated pipe ruptures.
During the past five years, I have been involved with studies and analyses of the seismic and blowdown qualification of Diablo Canyon.
I have had lead responsibility for the qualification of all equipment supplied by Westinghouse, which includes piping, components, and auxiliary and electrical equipment.
I am a member of the ASME and have served as a consultant to a task force investigating ASME faulted condition limits.
I have also served with the ANSI-N45 Ccmmittee as a task fcree member in the preparation of a methodology for assuring pump operability.
UNITED STATES OF l.MERICA NUCLEAR REGULATORY COMMISSION DEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATICNS FOR SAFETY HEARINGS Name:
Chi-Win Lin Title or Position:
Fellow Engineer for Westinghouse Degrees:
B.S.,
Civil Engineering, Taiwan Proc. Cheng-Kung University AsoA M.S.,
Engineering Mechanics & Sciences, University of Florida Af04 Ph.D., Engineering Mechanics & Sciences, Georgia Institute os secanoaogy Asoo
~
Professional Experience:
I joined Westinghouse Electric Corporation in October 1969 as a senior engineer in the Auxiliary Equipment group of the Pressurize'd Water Reactor Systems Division.
My responsibility was a lead engineer respon-sible for the development of the methods and the analysis of the auxiliary mechanical equipment.
In February 1974, I was promoted to Fellow Engineer and working for the Structural Technology group in the same Division.
I was responsible for the development of the seismic methods and criteria for systems and components, and was responsible for the auxiliary mechanical equipment analysis for special projects.
On October 1, 1978, I was transferred to the Plant Structural Engineering group and assumed the present responsibility.
h e e.
e UNITED 5TATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Dccket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon. Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Wilmer C. Gangloff Title or Position: Project Manager for Westinghouse Degrees:
B.S.
in Physics, Ohio State University 1964 Professional Experience: During my employment with Westinghouse, I have held positions of responsibility in the areas of reliability analysis of control a'nd protection systems performance for various postulated normal and accident conditions.
I have also had lead responsibility for reviewing conformance of safety and licensing standards in the areas of control and electrical systems, core designs, and postulated accidents.
Prior to my current position, I was one of those responsible for the devel-opeent of safety criteria and standards for Westinghcuse pressurized water reactor plants.
O r.,
,w
-r
4 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
. PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 O.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)-
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Bruce A.
Bolt Title or Position:
Professor of Seismolocrf
~
Degrees:
Ph.D. University of Sydney, Aust. 1959 D.Sc. University of Sydney,.Aust. 1972 1
Professional E:<perience:
Consultine Board ~for Earthcuake Analysis, Dept. of Water Resources 1967 to ctesent: Veterans Administ' ration, Earthcuaha and Wind Fcrees CO:mittee 1971-1975; California Seismic Safety Cor: mission 1979 to present; Member Office of Emercency Services Advisory Panel on Earthquake Prediction 1976- : Chairman Panel on Seismographic Networks, Nacional Academy of Sciences 1978; Member National Academy of Engineering; Registered Geolcgist and Geophysicisc (California).,
t
.c m-
.c
o-UNITED STATES OF AMERICA.
NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPMIY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Dr.
C.
Allin cornell Consultant and Prof. of Civil Engineering Title or Position:
M.I.T.,
Cambridge, MA 02139 Degrees:
A.B.. Architecture, 1960, Stanford University M.S. Civil Engineering, 1961, Stanford University Ph.D. Civil Engineering, 1964, Stanford University Professional Experience:
Research, teaching and consulting in earthquake engineering with special emphasis on proba-bilistic approaches to seismic hazard definitions.
Dr. Cornell has acted as censultant en seismic design criteria and risk analysis for several nuclear pcwer plants in the U.S.,
on air-craft crash risk analysis for nuclear power plants, on seismic risk analysis and ground motion for major dam projects, en wind-loading design specifications for high buildings, on probabilistic fire safety analysia; etc.
The consulting services were rendered to U.S. government agencies, to utilities, to engineers / architects companies, and to special engineering censultant firms.
The book by J.R. Benjamin and C.A. Cornell " Probability, Statistics and Decision for Civil Engineers", McGraw-Hill Scok'Co., New York 1970, can be regarded as che standard text book in this field.
.y, r
C*
.a UllITCD STATUS OF A:11-:nICA Il0CLCAR RCCULt.TO!!Y CO!!".IOUIC:1
'DCPORE Tl!C ATC!!IC SAPCT'I A:!D LICC::SII C noAnn In the !!atter of
)
)
Docke t 1;o s. 5 0-27 5 0. L.
PACIFIC GAS AND CLUCTRIC COliPA!;Y
)
50-323 0.L.
),
(Diablo Canyon 17acicar Power
)
)
Plant, Unit:i !!o.1 and 2)
. RCSUP.C CF QUALIFICATIO:1S FOR SAPCTY iiCARI!OS 1;ame:
Robert T.
Lawson Title or Position:
Executive Vice Presiden*
DcgrecS:
B.
S.,
Civil Enaineerine, University of Washingttn, 1948
' Profcssional Expericnce:
loaR-?O - dhmes r,ficore-Junior Encineer to Project Engineer
~~
- 19 5 0 U. S. Marine Corn.s - Infantrv. Officer 1955 Danes.& Moore - Various icvels of increasing responsibility to Partner in the S.F. office 1960- Presenti - Harding-Lawso;. Associates Executive Vice-Presidenc, consulting engineer 3
e e
1 e
m s--
-me
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
John Lysmer Title or Position:
Professor of civil e eta ari c Degrees:
M.Sc., Technical University of DamW, loca Ph.D., University of Michican. 1965 Professional Experience:
1965-78 Professor of civil Eneiraa-te.e Uni;crsity of California, Berkelev, a.d Consultant to numerous orcanizaticas in the areas of soil dynamics and eartheuake engineerine.
1962-65 Research Assistant and Lecturer Uni,versity of Michigan 1961-62 Instructor and Research Engineer University of Florida 1955-61 Civil Engineer i
ove Arup and Partners
, London U.K. and Lagos, Nigeria 1954-55 Civil Engineer Preben Schjdening, Cepenhagen, Cenmark
~
w-.
1 UNITED STATES OF AttE".tICA
~
- NUCLEAR REGULATORY CGhMISSION BEFORE THE ATOMIC-SAFETY AND LICENSING ECARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
1 (Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Richard H. Jahns Consultant (Prof. of Geology and Dean, School Title or Position:
of Earth Sciences, Stanford University)
Degrees:
B.S. Caltech, 1935; M.S. Northwestern, 1937; Ph.D. Caltech, 1943.,All degrees in Geology.
i Professional Experience:
Excarience in retroloav, mineralocv, and economic, engineering, glacial, and structural geolocy 'durin past 42 years of work with U.S.
Geological-Survey and at Caltech, Penn State, and Stanford.
Much of this experience was in California, including several parts of the coastal region.
Publications comprise several monographs and more than 100 scientific papers.
Edited and centributed to " Geology of Southern California",
published in 1954.as Bulletin of 170 of California Division of. Mines.
i e
I t
N i -
_,,._m,
_m -; _;_:,,-_--
-, - _. _ ~ _. _,......, - -,
s.
s UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275 0.L.
)
50-323 0.L.
(Diablo Canyon Nuclear Power
)
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
Dr.
H.
Bolton Seed Professor of Civil Engineering, Geotechnical Title or Position:
Engineering, Decartment of Civil Engineering, University of California, Serkeley Degrees:
B.S.
Kinas College, London University 1944 S.M.
Harvard University 1947 Ph.D. Kings Collece, London University 1948 Professional Experience:
Dr.
H. Bolton Seed is a nember of the faculty of the Department of Civil Engineering, Univegsity of California, Berkeley, since 1950 and has been engaged in research and instruccion in soil mechanics, seismic ground motion, soil licuefaction under seismic excitation, soil-structure interaction analyses for seismic response, seismic design of large civil engineering structures, etc.
Dr. Seed has been Chairman of the Department of Civil Engineering, U.C. Eerkeley, during 1965-1971.
Dr. Seed has acted as consultant on soil mechanics and seismic design problems to:
U.S. Nuclear Regulatory Ccmmission; Atemic Energy Organization of Iran; U.S. Army Corps of Engineers; U.S. Bureau of Reclamation; U.S.
Department of the Interior; U.S. Geological Survey; U.S.
Navy; U.S. National Aeronautics and Space Division; State (contd)
.a:
Professional Experience:
contd.
of California Department of Water Resources, Division of Highways, Division of Mines and Geology; Pacific Gas and Electric Company; Los Angeles Department of Water and Power, Oak Ridge National Laboratory; Westinghouse-Hanford Company, etc.
Dr. Seed is further acting as special consultant of solid mechanics and seismic. design problems to several Engineers / Architects and Consulting Engineers Companies.
9 r
1
-.m..
a.,
a.
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
}
}
Docket Nos. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
)
Plant, Units No.1 and 2)
)
RESUME OF QUALIFICATICNS FOR SAFETY HEARINGS I
uane:
S:ewart U. Smith
- 1 le or Position:
Professor and Chairman, Craduate Progra:n in Ce[) physics University of Washington, Seattle, WA 98195 1934 S.B. Ccology and Geophysics, Massachusetts Institute of Technology 1957 M.S C(.ophysics, California Institute of Technolo;;y t.
141 Ph of Tech.
. eof essional Expe.D.. Geoohysics and Mathematics, California Inst.
r rtence:
Ceophysicist, Shell 011 Company 1954-1"57 Assistant Prof. of Geophysics, Caltech 1961-19('4 Associate cro;. ot beupaysw,
m.w..
-.M - ~ '
p.
e,-e, c-,-,,
p 4..
e4r.r af 'J.w M naenn 1970-oresent T - r,. e,so.,, e, - -,,1.,
4.,. i, min,y. lo66-oresent Pccistered-Professional Geophysicist, Scace of California l
l I
i l
i
(
I i,
i a-
l
+
UllITCD STATCS OF A::CI:1CA NUCLCAR REGULATORY CO::MICSION
'I1CFORC Tl!C ATO:1TC SAFCTY A!!D LICCl!SIllG BOARD In the'!!atter of
)
)
Docket Noc. 50-275 0.L.
PACIFIC GAS AND ELECTRIC COliPA!1Y
)
50-323 0.L.
).
(Diablo Canyon Nuclear Power
)
Plant, Units No.1 and-2)
)
RESUME OF QUALIFICATIONS FOR SAFETY llEARINGS 4.
Name:
Takekazu Udaka 7
Title or Position:. Manager, Scil Dynami<is and Earthquake Enhineering Degrces:
Ph.D. Civil Encineering (Earthquake Engineering)*,
U.C.,
BerkeleyL 7
M.S. ' Civil Engineering (Soil Mechanics),
U.C.,
Berkeley l
4 B:S. Civil Engineering '(Soil Mechanics), Kyoto Univ.,' Japan
- Professional Experience:
Dr. Udaka. has participaced in the developmer.:
and application of analytical' procedures for the seismic analyst of soil deposits, carth structures, and soil-structure systems.
He 1s the author or co-author of the finite element ccmputer programs FLUSH, LUS!!, TRIP and TRAVEL.
Dr. Udaka speciali::es in s' oil dynamics,.especially in the analysis of soil-structure interaction problems..
Representative projects he has werked on include:
traveli'ng wave scismic ahalysis of F:r: Pack Cam,-
Montana; soil-structure interaction analyses for Fast Flu:<
Testing Facility, Washington; soil-structure interaction analys for South Texas Nuclear Projcct;. seismic stability analyses of -
ccoling ponds at X24-X25 tuclear Plant' Site, Missiccippi: 3:il-structure interaction studies fbr the Seneral Electric Company Standard Nuclear Plant; site-dependent respense spectra study for WPPSS-Hanford Nuclear Power Plant; pipeline displacement study for Southwest Ocean Outfall Project', California (SWOOP);
soil-structure interaction studies of underground storage tanks at Diablo Canycn Nuclear Power Plant, California: Seismic, Qualification Studies for' underground pipeline using traveling seismic waves at;Diablo Canyon Nuclear Pcwer Plant.
o--
UNITED STATES OF AMERICA 4
NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)
)
Docket Nos. 50-275 0.L.
PACIFIC CAS AND ELECTRIC COMPANY
)
50-323 0.L.
3 (Diablo Canyon Nuclear Power
' )
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
C. RICHARD WILLINGHAM Title or Position:
Geonhysicist, Earth Sciences Associates, Inc.
Degrees:
1966 B. A.
University of California Riverside 1968 M.S.. University of California Riverside Professional Experience:
1966-68 Geophysicist, Texaco, Inc. Work Inv'olved determination of structure and evaluation of hydrocarbon potential of areas in Eastern Santa Barbara Channel in connection with offshore federal lease sales. Princloal assienment was :he interpretation of seismic reflection data, though work often involved acting as II.if son be+ ween weln-Ist nnd weenhysicist anel the correhtfon of ceonhysical and geological data.
1972 Geophysicist, U. S. Earthquake Mechanisms Laboratory. Employment in-volved the development of new techniques for detecting contemporary fault movements and the study of the mechanism of fault craep.
1968-78 Consulting geophysicist. Consulting assignments have involved acting as chief geophysical investigator in projects to determine the structural geology and hydrocarbon potential of major portions of the offshore California borderland.
1973-78 Geophysicist, Earth Sciences Associates, Inc. Work has included gravity, magnette, and high resolution onshore and offshore seismic reflection studies to determine structure and seismic potential of nucicar power plant sites near Diablo Canyon, Humboldt Bay, and Collinsville, California.
1974-78 Assistant Professor of Geophysics and Astr'onomy, Santa Barbara City College, Santa Barbara, California.
4 e
e
. ~
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of
)~
~
)
Docket Nos. 50-275 0.L.
l PACIFIC GAS AND ELECTRIC COMPANY
)
50-323 0.L.
)
(Diablo Canyon Nuclear Power
')
Plant, Units No. 1 and 2)
)
RESUME OF QUALIFICATIONS FOR SAFETY HEARINGS Name:
DOUGLAS H. HAMILTON Engineering geologist; Vice President and Title or Position:
Principal Geologist, Earth Sciences Associates, Inc.
Degrees:
1956 B.S., Stanford University 1962 M.S., Stanford University Professional Experience:
1956 Geolocist, Utah Construction Comnany.
1957-60
_ Air Intellhtence Office, U. S. Navy.
1960 Ge' ologist, Phillios Petroleum Corporation.
1961-69 Fncincerin7 Gaolocist. W. A. Wahler and Associates. Geolocist for enci-neering projects, especially dams, in California and Chile.
1969 Geologic research regarding faulting and landslides in the Central Andes of Chile.
1969-78 Engineering Geologist, Earth Sciences Associates, Inc. Geologist for engineering projects, especially siting studies and geologic hazard assessments for power plants along the California coast. Work has included a siting study for the California coastal region between Point Conception and the Oregon border, and local and regional studies for sites at Diablo Canyon, Moss Landing, Davenport, Collinsville, Point Arena, and Humholdt Bay.
e.
UNITED SThTES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of
)
)
PACIFIC GAS AND ELECTRIC COMPANY
)
Docket Nos. 50-275-OL
)
50-32 3 -OL Units 1 and 2
)
)
Diablo Canyon Site
)
)
CERTIFICATE OF SERVICE The foregoing document (od of Pacific Gas and Electric Company has lhaxxd been served today on the following by deposit in the United States mail, properly stamped and addressed:
lizabe'h S. Bowers, Esq.
Mrs. Sandra A. Silver t
Chairman 1792 Conejo Avenue Atomic Safety and Licensing Board San Luis Obispo, California 93401 U. S. Nuclear Regulatory Commicsion Washington, D. C. 20555 Mr. Gordon Silver 1792 Conejo Avenue Mr. Glenn O. Bright San Luis Obispo, California 93401-Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Brent Rushforth, Esq.
Washington, D. C. 20555 center for Law in the Public Interest 10203 Santa Monica Drive
-Dr. William E. Martin Los Angeles, California 90067 Atomic Safety and Licensing Board Senior Ecologist David F.
Fleischaker, Esq.
Battelle Memorial Institute 1025 15th Street, N.W.
Columbus, Ohio 43201 5th Floor Washington, D. C. 20005
. irs. Elizabeth Apfelberg 1415 Cazadero Arthur C. Gehr, Esq.
San Luis Obispo, California 93401 Snell & Wilmer 3100 Valley Center Janice E. Kerr, Esq.
Phoenix, Arizona 85073 Public Utilities Commission of the State of California Bruce Norton, Esq.
5246 State Building 3216 North Third Street 350 McAllister Street Suite 202 San Francisco, California 94102 Phoenix, Arizona 85012 Mrs. Raye Fleming Chairman 1920 Mattie Road Atomic Safety and Licensing Shell Beach, California 93449 Board Panel U.
S. Nuclear Regulatory Commission Mr. Frederick Eissler Washington, D.
C. 20555-Scenic Shoreline Preservation Conference, Inc.
4622.'!cre ::csa Crive Santa Barbara, California 331 5
t Chairman Atomic Safety and Licensing Appeal Panel U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Secretary U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attn.:
Docketing and Service Section anes R. Tourtellotte, Esq.
Richard J. Goddard, E91 Office of Executive Legal Director BETH 042 U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Paul C. Valentine,.Esq.
321 Lytton Avenue Palo Alto, California 94302 Yale I. Jones, Esq.
100 Van Ness Avenue 19th Floor-San Francisco, California 94102 N.
Richard Hubbard
..dB Associates 366 California Avenue Suite 6 Palo Alto, California 94306 l?
m I,
j f'
l J-
.'ef,'sfM3,t
\\
/
L.
. ( 'e 4
l
. Philip A./ Crane, Jr.
f Attorney Pacific Gas and' Electric Ccmpany Data:
October 17, 1978