r October 6, 1994 Mr. D. L. Farrar Manager, Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III, Suite 500 1400 OPUS Place Downers Grove, IL 60515
SUBJECT:
SAFETY EVALUATION OF STEAM GENERATOR GIRTH WELD INSPECTION RESULTS ZION NUCLEAR POWER STATION, UNITS 1 AND 2 (TAC NOS. M89181 AND M89182)
Dear Mr. Farrar:
In a letter dated March 16, 1994, Commonwealth Edison Company (Comed or the licensee) reported its disposition of indications found in girth welds between the upner shell to transition cone of the steam generators of Zion Nuclear Power Station, Units 1 and 2.
Using the acceptance criteria of the ASME Code,Section XI, and fracture mechanics, the licensee dispositioned as acceptable all indications found during the dual unit outage examinations.
In letters dated May 26, 1994, and August 2,1994, the licensee submitted additional information in response to the staff's questions related to the girth weld inspections.
As stated in the attached safety evaluation, the staff concluded that the steam generators at Zion Nuclear Power Station, Units 1 and 2, are acceptable for continued service because the licensee has satisfactorily dispositioned flaws found in the upper shell to transition cone girth welds in the steam generators.
Sincerely, Original Signed By:
Clyde Y. Shiraki, Project Manager Project Directorate III-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-295, 50-304
Enclosure:
Safety Evaluation cc w/ encl:
See next page DlSTRIBUTION:
Docket File" PUBLIC PDIII-2 r/f OGC R. Capra C. Moore J. Roe C. Shiraki ACRS (10)
L. Miller, RIII DOCUMENT NAME: ZI89181.LTR To receive a cp6y'9 ttjs document, indicate in the box: "C" - Copy without enclusares "E" = Copy with enclosures *N"
= No copy f
0FFICE
!LA:#D111-2 l td-PM:PDIII-2 l6 D:PDIll-2 lE l
l NAME CM00RE CSHIRAKI:japf RCAPRA e DATE l10/6 /94 10/3-/94 10/G /94 1 10/
/94 10/ /94 0FFICIAL RECORD COPY
]6,
9410110263 941006 b!
PDR ADOCK 05000295 P
PDR I
'e October 6,1994 Mr. D. L. Farrar Manager, Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III, Suite 500 1400 OPUS Place Downers Grove, IL 60515
SUBJECT:
SAFETY EVALUATION OF STEAM GENERATOR GIRTH WELD INSPECTION RESULTS ZION NUCLEAR POWER STATION, UNITS 1 AND 2 (TAC NOS. M89181 AND M89182)
Dear Mr. Farrar:
In a letter dated March 16, 1994, Commonwealth Edison Company (Comed or the licensee) reported its disposition of indications found in girth welds between the upper shell to transition cone of the steam generators of Zion Nuclear Power Station, Units 1 and 2.
Using the acceptance criteria of the ASME Code,Section XI, and fracture mechanics, the licensee dispositioned as acceptable all indications found during the dual unit outage examinations.
In letters dated May 26, 1994, and August 2, 1994, the licensee submitted additional information in response to the staff's questions related to the girth weld inspections.
As stated in the attached safety evaluation, the staff concluded that the steam generators at Zion Nuclear Power Station, Units 1 and 2, are acceptable for continued service because the licensee has satisfactorily dispotitioned flaws found in the upper shell to transition cone girth welds in the steam generators.
Sincerely, OriginalStoned By:
Clyde Y. Shiraki, Project Manager Project Directorate 111-2 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation Docket Nos. 50-295, 50-304
Enclosure:
Safety Evaluation cc w/ encl:
See next page DISTRIBUTION:
Docket File PUBLIC PDIll-2 r/f J. Roe OGC R. Capra C. Moore C. Shiraki ACRS (10)
L. Miller, Rlll DOCUMENT NAME: 2189181.LTR To receive e copy of trys document indicate in the box: *C" a Copy without encloSJees *E" = Copy with enclosures *N" = No copy 0FFICE iLA:50141-2 l6 PM:PDill-2 16 D:PDill-2 lE l
l NAME CM00RE CSHIRAKI:japf
'RCAPRA v
. DATE 10/d /94 10/5 /94 10/re/94 10/ /94 10/ /94 0FFICIAL RECORD COPY
l l
L Mr. D. L. Farrar Zion Nuclear Power Station Commonwealth Edison Company Unit Nos. I and 2 l
cc:
Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60603 l
i Dr. Cecil Lue-Hing.
Director of Research and Development Metropolitan Sanitary District
)
of Greater Chicago 100 East Erie Street Chicago, Illinois 60611 l
Phillip Steptoe, Esquire i
Sidley and Austin One First National Plaza l
l Chicago, Illinois 60603 i
Mayor of Zion Zion, Illinois 60099 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 U.S. Nuclear Regulatory Commission Zion Resident Inspectors Office 105 Shiloh Blvd.
Zion, Illinois 60099 Regional Administrator U.S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 Station Manager Zion Nuclear Power Station 101 Shiloh Blvd.
Zion Illinois 60099-2797 4
i
.. m
_. ~,,.,
,