JULY, 1983 SHEET 1 0F 2
. x om MECHANICAL MAINTENANCE DEPARTMENT LER OR QS NATURE OF OUTAGE 1%LFUNCTION 7g EQUIPMENT MAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION hHEATINGBOILERMODIFICATION CORRECTIVE NA FACILITY CHANGE NA MODIFIED RELIEF VALVE oo MR-0482 73-83-5 PIPING & INSTALLED MANUAL o23 LIFTS FOR RELIEF VALVES eco-WHOLE CODY COUNTER CORRECTIVE NA REQUEST NA MODIFIED DETECTOR ARM MODIFICATION MR-0390 1A SEAL INJECT (SI) WATER CORRECTIVE NA VIBRATION LEAKING LINES REPLACED SUPPLY LINES PLUNGER SUPPLY LINES MR-0452/0489 CATION VALVE #94-22-024 CORRECTIVI NA CRACKED LEAKING REPLACED DIAPHRAGM MR-0515 DIAPHRAGM DIAPHRAGM 1A CONTAINMENT BUILDING AIR CORRECTIVE NA VIBRATION BEARI"G FAILURE REPLACED BLOWER BEARINGS CONDITIONER EAST BLOWER MR-0491 IB SI SUPPLY ORIFICE AND PREVENTIVE OUTAGE NA NA REPLACED GASKETS CONTROL R0D DRIVE MR-0503 83-07 SUPPLY ORIFICE LER 83-07 1A SI SUPPLY ORIFICE CORRECTIVE OUTAGE SI SYSTEM GASKET FAILURE REPLACED GASKET MR-0499 83-07 PRESSURE LER 83-07 TRANSIENT 1A EFFLUENT PUMP PREVENTIVE OUTAGE REGULAR PM NA OVERHAULED PUMP MR-0520 83-08 JOB 1A FORCED CIRCULATION PUMP CORRECTIVE OUTAGE HIGH D/P INCREASED SEAL REPLACED SEALS & ALL (FCP) UPPER SEALS MR-0507 83-08 LEAKAGE O RINGS 1B FCP UPPER SEAL CORRECTIVE OUTAGE HIGH D/P INCREASED SEAL REPLACED SEALS & ALL MR-0525 83-08 LEAKAGE O RINGS 1A FCP LIQUID DRIVE CORRECTIVE &
OUTAGE HIGH VIBRATION POSSIBLE CAUSE REPLACED ALL BEARINGS PREVENTIVE 83-08 0F SEAL WEAR
& 0 RINGS MR-0516
Y JULY, 1983 SHEET 2 DF 2 MECHANICAL MAINTENANCE DEPARTMENT LER OR NATURE OF OUTAGE MALFUNCTION EQUIPMENT MAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION RETENTION TANK PUMP, DECAY CORRECTIVE OUTAGE SEAL INJECT WATER IN OIL CHANGED OIL IN ALL PUMPS HEAT PUMP,1A & B SEAL MR-0496 83-08 ORIFICE INJECT PUMPS, AND 1A & IB LER 83-07 FAILURE FCP BEARING OIL RESERVOIR SEAL INJECT SUPPLY CORRECTIVE OUTAGE WORN SEAT LEAKING THROUGH REPLACED STEM, DISC, DISC VALVE #52-24-216 MR-0504 83-08 NUT, DISC PAD, PACKING &
LAPPED VALVE REACTOR SIGHT GLASS UPPER CORRECTIVE OUTAGE UNKNOWN LEAKING BONNET REPLACED BONNET GASKET ISOLATION VALVE #50-28-025 MR-0408 83-08 GASKET 1B RETENTION RECIRCULATION CORRECTIVE NA HARD PACKING VALVE HARD TO REPACKED VALVE VALVE #54-24-143 MR-0524 OPERATE STEAM TO RECOMBINER VALVE CORRECTIVE OUTAGE HARD PACKING VALVE HARD TO REPACKED VALVE C54-24-097 MR-0431 83-08 OPERATE WASTE WATER VALVE CORRECTIVE NA VIBRATION WORN HANDWHEEL REPLACED HANDWHEEL 054-24-025 MR-0531 0FFGAS B0OSTER FAN CORRECTIVE OUTAGE UNBALANCED FAN HIGH VIBRATION INSTALLED BALANCED FAN MR-0805 83-08 TURdINE BUILDING WEST PREVENTIVE NA FACILITY CHANGE NA INSTALLED TRENCH & GRATING SUMP TRENCH MR-0379/0481 FROM SUMP TO FLOOR DRAIN MAIN AIRLOCK INNER AND CORRECTIVE LER MISALIGNMENT &
D00R FAILURE &
REPLACED 3 CAM FOLLOWERS &
OUTER D0 ORS MR-0474 83-05 GASKET FATIGUE BLOWN GASKET ADJUSTED 2 INSIDE FOLLOWER BLOCKS - OUTER D00R.
REPLACED D0OR GASKET -
INNER DOOR EMERGENCY AIRLOCK CORRECTIVE LER GASKET FATIGUE BLOWN GASKET REPLACED GASKET INNER DOOR MR-0495 83-06