Revised Final Deficiency Rept Re Inability to Readily Retrieve Info from Valve Tag Number.Initially Reported on 801212.All Drawings to Be Revised by 831130 & Kept Current
ML20024E926
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 08/30/1983
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8309070245
Download: ML20024E926 (2)


Text

,--

c

.
. ~~.:__

? TENNESSEE YALLEY AUTHORITY-

. (jg 1

P,.

. CHATTANOOGA. TENNESSEE 374ot 7

e400 Chestnut Street Tower:II

. ' August30,-19_83-kAj SQRD-50-328/81 050

  • 8 U.S. Nuclear Regulatory Commission Region.II Attn: Mr. James P.' 0'Reilly, Regional. Administrator

-101 Marietta Street, NW," Suite'2900-Atlanta,._ Georgia 30303

Dear Mr. O'Reilly:

]

SEQUOYAH NUCLEAR PLANT UNIT 2 - RETRIEVABLE INFORMATION FROM YALVE TAG NUMBER - SQRD-50-328/81 REVISED FINAL REPORT The subject deficiency was initially report)d to NRC-0IE Inspector M. Thomas on December 12,.1980 in'accordance with 10 CFR 50.55(e) as NCR.SQN CEB 8035. Interia reports were submitted on January 12, March 2, April 2, June 11, and September 22,1981; April 7 and November 30, 1982 and April 12, 1983 Enclosed is a revised final report that was discussed with Linda Watson of your staff on August 24, 1983

- If you have any questions, please get in touch with R. H. Shell at FTS 858-2688.-

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Licensing Enclosure cc:: Mr. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Coinnission i

Washington, D.C.

20555 Records Center (Enclosure)

Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 OFI'ICIAL COW

$37@$'oESh llI 1983-TVA SOrH ANNIVERSARY An Equal Opportunity Employer L

ENCLOSURE SEQUOYAH NUCLEAR PLANT UNIT 2 RETRIEVABLE INFORMATION FROM VALVE TAG NUMBERS'

-NCR SQN CEB 8035.

SQRD-50-328/81-05 10 CFR 50.55(e)

REVISED FINAL REPORT Description of Deficiency Manufacturer's valve drawings which include pertinent engineering data used in piping analysis and other design calculations cannot be readily retrieved through any TVA documentation system as required by 10 CFR 50, Appendix B.

Proper identification of valves should be maintained by part number, serial number, or other appropriate means on the valve bodies and cross-referenced on all associated drawings and permanent records. This identification is used for the retrieval of records and is designed to prevent the use of incorrect parts and components in piping systems.

Safety Implications Without these controls, a piping analysis may utilize an incorrect valve weight which could invalidate the seismic analysis of various safety-related systems. This could lead to pipe failure during a seismic event and reduced safety injection system (SIS) coolant flow rate to the core, which could adversely affect the safety of the plant.

Corrective Action Engineering change notice L-5680 has been issued in order to revise TVA drawing series 47A365, 47A366 and 47B601 to cross reference the manufacturer's valve drawing numbers for 'all QA valves. These drawings will be revised by November 30, 1983, and will be kept current each time a new valve is added to the system.

The new schedule is necessary to allow revision of the 47B601 series drawings which include the control and motor operated valves.