g EI 1300.02.0 Davis-Besse Nuclear Power Station Unic No. 1 Emergency Plan Implementing Procedure EI 1300.02 Unusual Event Record of Approval and Changes Prepared by C. J. Reed 5/30/80 Date
. Submitted by C. E. Wells 6/13/80 Section Head D te I
4' h M g6 Recommended by Chain 1!ian Date
(
QA Approved 8
Quality Assurance Manager Date Approved.by N
O kh^-=^ 'i
[// &/@
StationSuperintendend Date i
Revision SRB QA Sta. Supt.
No.
Recommendation Date Approved Date Ap roved Date
/ fhf
- W //
Nh W } lk '#l8/
p pa e g Gl>qr y /r v n" - ^ ^ g
,Mh-3 p
_4 l0l,s/h. //ll--
40%"*/&o*n ^-
fW y pg yp p, n u m -i
'N
]
d e
8308090056 830726 PDR ADOCK 05000346 F
~
4 1
EI 1300.02.2 1.
PURPOSE To outline the course of action and protective measures required to mitigate the consequences of a Station emergency at the Unusual Event level to safeguard Station personnel and the general public.
2.
SCOPE Describes the actions and responsibilities of Davis-Besse per-sonnel and offsite support groups. in the event the Shift Super-visor declares an Unusual Event in accordance with the Emergency Plan Activation procedure, EI 1300.01.
3.
REFERENCES 3.1 Davis-Besse Nuclear Power Station Emergency Plan l
3.2 Station Response to Emergencies, EI 1300.00 3.3 Emergency Plan Activation, EI 1300.01 3.4 First Aid' Response, AD 1827.02 3.5 Protective Action Guidelines, AD 1827.12
-s 4.
DEFINITIONS
\\-
4.1 Unusual Events - Event (s) are in progress or which occurred that indicate a potential degradation of the level of safety of DBNPS.
5.'
EMERGENCY MEASURES 5.1 Shift Supervisor The Shift Supervisor, having assumed the role of interim l
Emergency Duty Officer and having classified the emer-l gency as an Unusual Event, shall assure the following i
actions are taken as required (See Attachment 1):
5.1.1 Make the appropriate notifications or sound the appropriate alarm as necessary:
h
- a. Fire i
- b. Containment Evacuation
- c. Initiate Emergency Procedures 2
NOTE:
The station alarm need not be sounded if downgrading from a higher classification.
2
- y. -
I,
+ -
3 EI 1300.02.4 3.
The Shift Supervisor or his designee shall then activate the pagers of the key emergency response personnel as listed in Administrative Memorandum No. 37.
4.
When paged (beeped), those individuals must telephone the Edison Operator who shall connect them with the Telephone Pager thus allowing them to hear the recorded message.
5.
These individuals shall then " call in" or notify additional personnel as required to provide adequate response to the event by using Administrative Memorandum No. 37.
NOTE:
The NRC resident inspector can be telephoned or paged in accordance with AD 1827.17 if necessary.
5.1.4 Notification of the following agencies must occur:
NOTE:
When notifying an outside agency, record the name of the individual contacted and request a return telephone call from the agency to verify notification.
\\
a.
Sheriff's Department, Ottawa County, within 15 minutes of an emergency declaration. This notification can be accomplished by phone using either the commercial number or an unlisted number provided for emergencies (both found in Admin. Memo 37) or by radio through CAS or SAS.
l b.
NRC Region III, Office of Inspection and Enforcement; l,
NRC, NRR, Emergency Incident Response Center, i-Bethesda, Maryland (This is accomplished by the l
NRC Emergency Notification System - Red Phone) within one hour.
5.1.5 Continue in the capacity of interim Emergency Duty Officer until relieved by the assigned Emergency Duty 4
Officer. In the event that the EDO cannot be contacted or does not arrive in a timely manner, the Shift Supervisor must complete those steps performed by the EDO, until relieved.
~
5.1.6 Assess the situation by monitoring Control Room and other plant instrumentation;
- a n
5 EI 1300.02.1 7
5.2.6 Recommend protective actions to the Ottawa County Sheriff if required by assessment results per AD 1827.12, Protective Action Guidelines.
5.3 Shift Operations Personnel 5.3.1 Control Room operators shall maintain safe operations of the Station and minimize the potential hazards to Station personnel and the general public as directed by the Shift Supervisor.
5.3.2 In the event that the Shift Supervisor is incapacitated, his duties and responsibilities indicated in Step 5.1 shall be assumed by the Assistant Shift Supervisor in the Control Room until relieved by a qualified Shift Supervisor.
5.3.3 Equipment and auxiliaries operators shall main-tain safe operations of the Station as directed by the Shift Supervisor.
5.3.4 The Shift Technical Advisor shall provide tech-nical and analytical support in the diagnosis of off-normal events. He shall also advise and assist the Shift Supervisor on matters per-
~7 taining to the safe and proper operation of the s
plant with regards to nuclear safety.
5.4 Shift Chemistry and Radiation Tester (C&RT) 5.4.1 The shift C&RT shall report immediately to the Health Physics Monitoring Room to await instruc-tion from the Shift Supervisor or Chemist and Health Physicist.
5.4.2 The shift C&RT shall provide radiological monitoring for the Fire Brigade in the event of a fire in RACA.
5.4.3 The shift C&RT shall monitor all injured per-1 sonnel before they leave the site. An off-shift C&RT shall accompany or meet the contaminated personnel at the offsite medical facilities.
5.5 Fire Brigade 5.5.1 The Fire Brigade Captain shall respond to any announced fire, evaluate the situation, direct the Fire Brigade, and keep the Shift Supervisor informed of the status of the fire.
,,--,,m-
-,ee--
+, --,, -. -
y
- - p y; ;
~.:
_. s "g
- y
- Nb
.g s
,f' a
~,
~
~
?'
\\
s
w
- w s
m.
.. ~.,
,x.e
~
x,,,
1 s
7 FI 13M. 02.2 l
J c.
s
.~ -
e 5.10.2 The H.B. Magruder Memorial Hospital shall' provide offsite medical treatment for personne.1 a:- required.
c A
+
The Carroll Township Fire Departmed.t'shall providh,i 5.10.3
./ '
primay respuase to fire alarms onsite as required. -
~
l>
a.
The Village of Oak Hgrbor Fire Dephttment shall.* * /
provide alternate response to fire Alarms onsite
'x as re9uired through mutual aid.with Carroll
',e-Township.
q s
a.
~
5.~ 10. 4 >'
Tha,0t'tawa county Sheriff's Department is notified in
^
order that local authoritiya eny be prepared to answer ingdifies generat;d by;r W public. The Sheriff's Departtent,is also'tb2 edin cont.ast for medictl'and x;
fire support agencics 6bo respondeto Davisdessa'(See
~ '
Sections 5j10.1, 5 d0.1,and 5.10.3 abovej.
"'l w
+,
/
'/- c.
6.
TERMINATION
' 74 s
x
,,7 s
s' y
~
6.1 The Emergency D4y Officer and Station Operations Man,ag' r have.
joint responsibility far dererslaint ar.d declaring whgu'the emergency situatiot t* > stable. ",
,, ' /
r+,
.n >
n 6.2 The Emergency Duty,0fficer shall assure notification of all offsite organizations and,TECo personnel that the emergency:has terminated.
g g
y-,
+
7
- ^ 2 -
6.3 A writtea summary, vill follgk'notificas.iAn of termination within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
'7
,r
. N
,, y
~.
a s
r g
r
-g(
Y y
,O w
w i
%.7*=
x
% 1' 27 g.
,,Ne
' pr' m
.7 r
~
[I y
C g
g A ^ '
g g
\\
w 31 k
,\\
s,
,j#
g
)
f,
- ?
s y
4 f.
p 3
s 4
yw rt A
a#
, ~ * '
=,
\\
rg
/
d.
4 4
\\9 b.,
e
.:u k
+.
C-
t 8
EI 1300.02.4 ED0/ SHIFT SUPERVISOR CHECKLIST FOR EMERGENCY EVENT An Unusual Event (UE) was declared on at A.M./P.M.
(Date)
(Time) by due to (Title)
(Cause)
The appropriate announcement was made or alarm sounded at A.M./P.M., by (Time)
(Title)
An Alert was declared on at A.M./P.M., by (Date)
(Time)
(Title) due to (Cause)
The appropriate announcement was made or alarm sounded at A.M./P.M., by (Time)
(Title)
,_s
[
.s A Site Emergency was declared on at A.M./P.M.
(Date)
(Time) by due to (Title)
(Cause)
The appropriate announcement was made or alarm sounded at t
i A.M./P.M. by
(
(Time)
(Title) l A General Emergency (GE) was declared on at A.M./P.M.
i (Date)
(Time)
I by due to l
(Title)
(Cause)
~,
The appropriate announcement was made or alarm sounded at A.M./P.M. by t,
(Time)
(Title)
The declared classification has been confirmed:
Unusual Event by at A.M./P.M.
__N (Title)
(Time) l
)
4 Sheet 1 of 4 I
1
,m 9
EI 1300.02.4 Checklist Alert by at A.M./P.M.
Site by ___
at A.M./P.M.
Gen'l. Emer by at A.M./P.M.
Conduct the necessary notifications to:
UE (Time / Int)
. ALERT SITE GE (Time / Int)
(Time / Int)
(Time / Int) l 1.
Secondary Alarm Station (SAS)
NOTE:
In the event of a fire or medical emergency, the SAS Operator will make calls for emergency support and/or notification of the following agencies or personnel.
a.
Fire Dept.(s) b.
Emer. Medical Service (EMS)
/'..
-s i(
fj c.
Edison Oper.
~
d.
Magruder Hosp.
.,?
e.
St. Charles Hospital f.
Life Flight 2.
Nuclear Security Supervisor l.
3.
Station Supt.
l:
Ii NOTE:
The Ottawa County Sheriff must be notified within 15 minutes of an emergency declaration. The Station Superin,
tendent or his designee is responsible for this notification.
!)
-a.
The Ottawa County Sheriff was notified at A.M./P.M.
by The message was given to (Title)
(Name)
The following information was relayed:
ii li q
ll
'm _ /
1 t,
i!
Sheet 2 of 4 J-li a
4 10 EI 1300.02.4 O)
Checklist
,e (Brief Summary) y UE ALERT SITE GE (Time / Int)
(Time / Int)
(Time / Int)
(Time / Int) 4.
Key Emergency Re-sponse Personnel 5.
NRC (via ENS)
NOTE:
The NRC must be notified within one hour of the declaration of an emerg4acy classification and should be made by Station management.
The initial information given to the NRC was received by:
, and was as follows:
gd, (Brief Summary) hv r
Perform the applicable steps of ECC Checklist
- EI 1300.08 Activated (Center activations'are not required for each classification and l
may be coitted where applicable):
a.
ECC s
b.
TSC c.
OSC j
d.
ESC j.
~
x'j Sheet 3 of 4 4
y
-m 11 EI 1300.02.4 Checklist UE AIIRT SITE GE (Time / Int)
(Time / Int)
(Time / Int)
(Time / Int)
Conduct periodic up-dates for:
a.
TED Personnel b.
NRC c.
. Ottawa County Sheriff / County EOC (REFER TO ATTACHMENT 2)
As the condition is resolved, the classification is downgraded to:
Site Alert at:
A.M./P.M.
A.M./P.M.
/
by:
t, Unusual Event Declassified at:
A.M./P.M.
A.M./P.M.
by:
When the condition is declassified, notify:
a.
TED personnel at A.M./P.M.,by (Time)
(Title) b.
NRC at A.M./P.M.,by (Time)
(Title) c.
Ottawa County Sheriff at A.M./P.M., by (Time)
(Title)
REVIEWED BY FILED BY:
Station Superintendent Emerge.ncy Planning Supervisor w
e r
Sheet 4 of 4
12 EI 1300.02.4 ED0/ SHIFT SUPERVISOR PERIODIC UPDATE RECORD FOR EMERGENCY EVENT Conduct period updates for:
a.
TED personnel at A.M./P.M.:
b.
NRC at A.M./P.M.:
c.
Ottawa County Sheriff / County EOC at A.M./P.M.:
["N Conduct periodic updates for:
(.
i a.
TED personnel at A.M./P.M.:
b.
NRC at A.M./P.M.:
c.
Ottawa County Sheriff / County EOC at A.M./P.M.:
(\\;7 END Sheet 1 of 1 i
i.
EI 1300.03.0 Davis-Besse Nuclear Power Station Unit No. 1 Emergency Plan Implementing Procedure EI 1300.03 Alert Record of Approval and Changes Prepared by G. J. Reed 5/30/80 Date Submitted by C. E. Wells 6/13/80 Section Head Date Recommended by I[8W h/3h SR3 Chairfan
'Dade QA Approved
//
Quality Assurance Manager Date Approved,by N
' -- - i
'O StationSuperintendj(e Date Revision SR3 QA Sta. Supt.
No.
Recommendation Date Approved Dat(
Approved D,ay e.
l anil?gye 9//9 ll8 W""/pd %
y A &-
g S,%ja. yg p w " 3
'I> @ u 3
h to} af t'2 f To" " l~3 / h - f g ;2 V g ' A y 4/ys3 /VN" Yb-M M I'~M i j 1
O 1 EI 1300.03.2 1. PURPOSE To outline the course of action and protective measures required to mitigate the consequences of Station emergency at the Alert level to safeguard Station personnel and the general public. 2. ~ SCOPE Describes tha actions and responsibilities of Davis-Besse per-sonnel and offsite support groups in the event the Shift Supervisor declares an Alert as identified in the Emergency Plan Activation 4 procedure, EI 1300.01. 3. REFERENCES 3.1 Davis-Besse Nuclear Power Station Emergency Plan 3.2 Station Response to Emergencies, EI 1300.00 3.3 Emergency Plan Activation, EI 1300.01 3.4 Protective Action Guidelines, AD 1827.12 4. DEFINITIONS 4.1 Alert - Events are in progress or have occurred which involve an actual or substantial degradation of the level of safety of DBNPS. 5. EMERGENCY MEASURES 3.1 Shift Supervisor The Shift Supervisor, having assumed the role of interim Emergency Duty Officer and having classified the emer- ~ gency as an Alert, shall assure the following' actions are taken as required (See Attachment 1): 5.1.1 Make the appropriate notifications or sound the j appropriate alarm as necessary: l l
- a. Fire i
- b. Containment Evacuation i
O. Initiate Emergency Procedures 2 NOTE: The station alarm need not be sounded if downgrading from a [ higher classification. I s .V i' !1 I
3 EI 1300.03.4 s 3. The Shift Supervisor or his designee shall then activate the pagers of the key emergency response personnel as listed in Administrative Memorandum No. 37. ^ 4. When paged (beeped), those individuals must telephone the Edison Operator who shall connect them with the Telephone Pager thus allowing them to hear the recorded message. 5. Those individuals shall then " call in" or notify additional personnel as required to provide adequate response to the event by using Administrative Memorandum No. 37. NOTE: The NRC resident inspector can be telephoned or paged in accordance with AD 1827.17 if necessary. 5.1.4 Notification of the following agencies must occur: NOTE: When notifying an outside agency, record the name of the individual contacted and request a return telephone call from the agency to verify notification / t a. Shetiff's Department, Ottawa County, within 15 minutes of an emergency declaration. This notification can be accomplished using either the commercial number or an unlisted number provides for emergencias (both found in Admin. Memo 37) or by radio through CAS or SAS. b. NRC Region III, Office of Inspection and Enforcement; NRC, NRR, Emergency Incident Response Center, Bethesda, Maryland (This is accomplished by the NRC Emergency Notification System - Red Phone) within one hour. 5.1.5 Continue in the capacity of interim Emergency Duty Officer until relievsd by the assigned Emergency Duty 4 Officer. In the event that the EDO cannot be contacted or does not arrive in a timely manner, the Shift Supervisor must complete those steps performed by the EDO, until relieved. 5.1.6 Assessment actions which shall include: a. Increased surveillance of in-plant instrumentation. s s' 4 l
r 5 EI 1300.03.1 -s 5.2.6 Recommend protective actions to the Ottawa County Sheriff as required by assessment results per AD 1827.12, Protective Action Guidelines. 5.3 Shift Operations Personnel 3.3.1 Control Room operators shall mainthin safe operations of the Station and minimize the potential hazards to Station personnel and the general public as directed by the Shift Supervisor. 5.3.2 In the event that the Shift Supervisor is incapacitated, his duties and responsibilities indicated in Step 5.1 shall be assumed by the Assistant Shift Supervisor in the Control Room until relieved by a qualified Shift . Supervisor, f 5.3.3 Equipment and auxiliaries 'erators shall maintain safe operations of the plant as directed by the Shift Supervisor. 5.3.4 The Shift Technical Advisor shall provide technical L and analytical support in the diagnosis of off-normal events. He shall also advise and assist the Shift Supervisor on matters pertaining to the safe and proper operation of the plant with ~regards to nuclear ) safety. i L l 5.4 Shift Chemistry and Radiation Tester (C&RT) l l 5.4.1 The shift C&RT shall report immediately to the Health l Physics Monitoring Room to await instructions from the l Shift Supervisor or Chemist and Health Physicist. l j. 5.4.2 The shift C&RT shall provide radiological monitoring for the Fire Brigade in the event of a fire in RACA. i 5.4.3 The shift C&RT shall monitor all injured personnel I before they leave the site. An off-shift C&RT shall accompany or meet the contaminated personnel at the l offsite medical facilities. i 5.5 Fire Brigade J t b 5.5.1 The Fire Brigade Captain shall respond to any announced fire, evaluate the situation, direct the Fire Brigade, l and keep the Shift Supervisor informed of the status of the fire. L l-( N l 0 5. 1 I
7 EI 1300,03.4 5.8.4 RMT's responding from offsite will report to the RTL for further assignment. 5.9 Onsite Personnel 5.9.1 Personnel, who do NOT have specifically assigned duties shall proceed to areas as prescribed in ad 1827.11 Assembly, Accountability, and Subsequent Evacuation. 5.10 Offsite Personnel 4 5.10.1 Station personnel whose emergency response is at the station will be admitted upon~ verbal communication with security. These personnel should report to their emergency assembly area (as designated by AD 1827.11) for assignment. 5.10.2 Station personnel whose emergency response is in the DBAB will report to their designated location. 5.10.3 Non-badged personnel will report to the location designated by this contact according to the severity of the emergency (ie DBAB, PPF, or ESC). Normal badging procedures will be utilized if it becomes necessary for these personnel to enter the station. 5.11 Offsite Agencies and Organizations 5.11.1 The Carroll Township Ambulance Service shall provide transportation service as required for offsite medical treatment. 5.11.2 The H. B. Magruder Memorial Hospital shall provide u offsite medical treatment for personnel as required. I 5.11.3 The Carroll Township Fire Department shall provide primary response to fire alarms onsite as required. l a. The Village of Oak Harbor Fire Department shall provide alternate response to fire alarms onsite as required through mutual aid with Carroll Township. 5.11.4 The Ottawa County Sheriff's Department is experienced F in providing area control, communications assistance, and direct handling of the local population, including-evacuation, should it become necessary. The Sheriff's Department provides 24 hour radio communication coverage with the Shift Supervisor at DBNPS and is \\
- z..-
I 4 i
9 EI 1300.03.4 ED0/ SHIFT SUPERVISOR CHECKLIST FOR EMERGENCY EVENT An Unusual Event (UE) was declared on at A.M./P.M. (Date) (Time) by due to (Title) (Cause) The appropriate announcement was made or alarm sounded at A.M./P.M., by (Time) (Title) An Alert was declared on at A.M./P.M., by (Date) (Time) (Title) due to (Cause) The appropriate announcement was made or alarm sounded at A.M./P.M., by (Time) (Title) [' T A Site Emergency was declared on at A.M./P.M. (Date) (Time) by due to (Title) (Cause) The appropriate anncancement was made or alarm sounded at A.M./P.M. by (Time) (Title) A General Emergency (GE) was declared on at A.M./P.M. (Date) (Time) by due to (Title) (Cause) The appropriate announcement was made or alarm sounded at A.M./P.M. by (Time)- (Title) The declared classification has been confirmed: Unusual Event by at A.M./P.M. ,/ ~~'] (Title) . Time) ( ,'L) Sheet 1 of 4 (
o 10 EI 1300.03.4 l Checklist Alert by at A.M./P.M. 9 Site by at A.M./P.M. Gen'1.~Emer by at A.M./P.M. Conduct the necessary notifications to: UE ALERT SITE GE (Time / Int) (Time / Int) (Time / Int) (Time / Int) 1. Secondary Alarm Station (SAS) ' NOTE: In the event of a fire or medical emergency, the SAS Operator will make calls for emergency support and/or notification of the following agencies or personnel. s. Fire Dept.(s) b. Emer. Medical i Service (EMS) f ' c. Edison Oper. ( ) d. Magruder Hosp. e. St. Charles Hospital f. Life Flight 2. Nuclear Security l Supervisor l l 3. Station Supt. I NOTE: The Ottawa County Sheriff must be notified within 15 minutes of an emergency declaration. The Station Superin-tendent or his designee is responsible for this notification. i a. The Ottawa County Sheriff was notified at A.M./P.M. F c 1 by The message was given to j (Title) (Name) j The following information was relayed: s I .s) 1 J L l Sheet 2 of 4 a )
6 0 t 11 EI 1300.03.4 -s checklist (Brief Summary) 1 t UE AI.ERT SITE CE (Time / Int) (Time / Int) (Time / Int) (Time / Int) 4. Key Emergency Re-sponse Personnel 5. 'NRC (via ENS) NOTE: The NRC must be notified within one hour of the declaration of an emergency classification and should be made by Statica management. The initial information given to the NRC was received by: , and was as follows:
- I
) (Brief Summary) Perform the applicable steps of ECC Checklist EI 1300.08 1 Activated (Center activations are not required for each classification and ll, may be emitted where applicable): a a. ZCC Rlj b. TSC ti l c. OSC q.' d. ESC L l. a j ) Attachment I h Sheet 3 of 4 u m
12 EI 1300.03.4 Checklist UE ALERT SITE GE (Time / Int) (Time / Int) (Time /Inc) (Time / Int) Conduct periodic up-dates for: a. TED Personnel b. NRC c. Ottawa County Sheriff / County EOC (REFER TO ATTACHMENT 2) t As the condition is resolved, the classification is downgraded to: Site Alert at: A.M./P.M. A.M./P.M. by: i Unusual Event Declassified at: A.M./P.M. A.M./P.M. by: When the condition is de'lassified, notify: c a. TED personnel at A.M./P.M., by (Time) (Title) b. NRC at A.M./P.M., oy (Time) (Title) c. Ottawa County Sheriff at A.M./P.M., by (Time) (Title) REVIEWED BY FII.ED BY: Station Superintendent Emergency Planning Supervisor J m l .) Sheet 4 of 4 -.L.----..,--------.-~- --~---~----ms-<-~~~~~-- ~~ - - ~ - ~ ~ -
l 13 EI 1300.03.4 -m ED0/ SHIFT SUPERVISOR PERIODIC UPDATE RECORD FOR EMERGENCY EVLNT Conduct period updates for: a? TED personnel at A.M./P.M.: b. NRC at ~ A.M./P.M.: c. Ottawa County Sheriff / County EOC at A.M./P.M.: Conduct periodic updates for: ('. TED personnel at A.M./P.M.: s l a. b. NRC at A.M./P.M.: i _A.M./P.M.: c. Ottawa County Sheriff / County EOC at 4 I - ~., \\ b END Sheet 1 of 1 ...w -,,me. m.
l EI 1300.04.0 Davis-Besse Nuclear Power Station Unic No. I 1 Emergency Plan Implementing Procedure EI 1300.04 l Site Emergency Record of Approval and Changes Prepared by C. J. Reed '5/30/80 Date Submitted by C. E. Wells 6/13/80 Section Head Date Mj,,f Recommended by g' SR3 Chairgdi 'Date QA Approved // [ Quality Assurance Manager Date Approved.by T'NN Station Superintendent (/ Date Revision SRB QA Sta. Supt. [; No. Recommendation Date Approved Date Approved Date l WWf ll'Y/E/ jfh WNW/ bI i y Aw j cpva, gr we'~ g /* ^ 7 icjalw $ W M 3p?- 3 9 y n,- n ~~m a i 'Og
1 EI 1300.04.2 1 1. PURPOSE To outline the course of action and protective measures required to mitigate the consequences of a Station emergency at the Site Emergency level to safeguard Station personnel and the general public. 2. SCOPE 1 Describes the actions and responsibilities of Davis-Besse per-sonnel and offsite support groups in the event the Shift Super-visor. declares a Site Emergency in accordance with the Emergency Plan' Activation procedure, EI 1300.01. 3. REFERENCES 3.1 Davis-Besse Nuclear Power Station Emergency Plan 3.2 Station Response to Emergencies, EI 1300.00 3.3 Emergency Plan Activation, EI 1300.01 3.4 Protective Action Guidelines, AD 1827.12 4. DEFINITIONS g-, ( i 4.1 Site Emergency - Events are in progress or have occurred which involve actual or likely major failures of DBNPS functions needed for the protection of the public. There also exists a significant actual or potential release of radioactive material. 5. EMERGENCY MEASURES 5.1 Shift Supervisor The Shift Supervisor, having assumed the role of interim Emergency Duty Officer and having classified the emer-j. gency as a Site Emergency, shall assure the following actions are taken as required (See Attachment 1): 5.1.1 Sound the appropriate alarm: i.
- a. Fire s
4 l
- b. Containment Evacuation 1:
)1
- c. Initiate Emergency Procedures 1
2 NOTE: The station alarm need not be i sounded when downgrading from i a higher classification. s A e f. J c 'lt' f
i EI 1300.04.4 s 3. The Shift Supervisor or his designee shall then activate the pagers of the key emergency response individuals as listed in Administrative Memorandum No. 37. 4. When paged (beeped), those individuals must telephone the Edison Operator who shall connect them with the Telephone Pager thus allowing them to hear the recorded message. NOTE: The NRC resident inspector can be telephoned or paged in accordance with AD 1827.17 if necessary. 5. Those individuals shall then " call in" or notify additional-personnel as required to provide adequate response to the event by using Administrative Memorandum No. 37. 5.1.4 Notification of the following agencies must occur: NOTE: When notifying an outside agency, record the name of the individual contacted and request a return telephone call from the agency to verify notification. i a. Sheriff's Department, Ottawa County, within 15 minutes of an emergency declaration. This notification can be accomplished by phone using either the commercial number or an unlisted number provided for emergencies (both found in Admin. Memo 37) or by radio through CAS or SAS. b. NRC Region III, Office of Inspection and Enforcement; NRC, NRR, Emergency Incident Response Center, Bethesda, Maryland (This is accomplished by the NRC Emergency Notification System - Red Phone) l' within one hour. li 5.1.5 Continue in the capacity of interim Emergency Duty Officer until relieved by the assigned Emergency Duty 4 Officer. In the event that the EDO cannot be contacted or does not arrive in a timely manner, the Shift Supervisor must complete these steps performed by the i l[ EDO, until relieved. 5.1.6 Perform assessment actions which shall include: l h ~~ - J. l
5 EI 1300.04.0 5.2.3 Determine to what extent the offsits and onsite emergency organizations shall be activated. a. For a Site Emergency, the emergency teams and the entire onsite emergency organization shall be activated. A major portion, if NOT all, of the offsite emergency organization may be activated. 5.2.4 Activate the ECC according to the Emergency Control Center Activation Procedure,, EI 1300.08. 5.2.5 Continue assessment actions initiated by the Shift Supe rvisor. 5.2.6 Recommend protective actions to the Ottawa County Sheriff as required by assessment results per AD 1827.12, Protective Action Guidelines. 5.2.7 Ensure that continuors online phone communications are maintained with the Scate and County Emergency Operations Centers. 5.3 Shift Operations Personnel 5.3.1 Contro'l room operators shall maintain safe operations (' of the Station and minimize the potential hazards to Station personnel and the general public as directed by the Shift Supervisor. 5.3.2 In the event that the Shift Supervisor is incapacitated, his duties and responsibilities indicated in Step 5.1 shall be assumed by the Assistant Shift Supervisor in the Control Room until relieved by a qualified Shift Supervisor. 5.3.3 Equipment and auxiliaries operators shall maintain safe operations of the plant as directed by the Shift Supervisor. 5.3.4 The Shift Technical Advisor shall provide technical and analytical support in the diagnosis of off-normal events. He shall also advise and assist the Shift Supervisor on matters pertaining to the safe and proper operation of the plant with regard's to nuclear safety. 5.4 Shift Che'mistry and Radiation Tester (C&RT) 5.4.1 The shift C&RT shall report immediately to the Health Physics Monitoring Room to await instructions from the Shift Supervisor or Chemist and Health Physicist. a y
4 7 EI 1300.04.4 members will. report to the turbine deck assembly area adjacent to the OSC. 5.8.2 The OSC Manager will designate RMT members as to their assignment as offsite or onsite. a. A list of qualified RMT's is found in Administrative Memo 42. b. Only one member of each team should be from the C&HP section. 5.8.3 If requested by the EDO, offsite RMT's will be dispatched to the Radiological Testing Laboratory (RTL) for further instructions. j 5.8.4 RMT's responding from offsite will report to the RTL for further assignment. 5.9 Plant Staff Members of the plant staff that have been informed of a Site Emergency s, hall proceed to their designated locations and perform their assigned functions. ' / 5.9.1 The Plant Operations Manager shall proceed to the Control Room. He shall direct plant operations and plant damage control efforts. He shall also keep the Station Operations Manager advised of plant operations. 5.9.2 The Operations Engineer shall proceed to the Control Room. His functions are to supervise control room activities, to perform onthe-spot operational analysis as required to acsist the Shift Supervisor, and keep the Plant Operations Manager informed of current plant conditions. 5.10 Onsite Personnel ? 5.10.1 Personnel, who do NOT have specifically assigned duties shall proceed to assembly areas as prescribed in AD 1827.11 Assembly, Accountability, and, Subsequent Evacuation. p 5.11 Offsite Personnel l 4, 5.11.1 ~ Station personnel whose emergency response is at the station will be admitted upon verbal communication I with security. These personnel should report to their emergency assembly area (as designated in AD 1827.11) for assignment. ~~ /. i.
9 EI 1300.04.4 ED0/ SHIFT SUPERVISOR CHECKLIST FOR EMERGENCY EVENT An Unusual Event (UE) was declared on at A.M./P.M. (Date) (Time) by due to (Title) (Cause) The appropriate announcement was made or alarm sounded at A.M./P.M., by (Time) (Title) An Alert was declared on at A.M./P.M., by (Date) (Time) (Title) due to (Cause) The appropriate announcement was made or alarm sounded at A.M./P.M., by (Time) (Title) / / A Site Emergency was declared on at A.M./P.M. (Date) (Time) by due to (Title) (Cause) The appropriate announcement was made or alarm sounded at A.M./P.M. by (Time) (Title) A General Emergency (GE) was declared on at A.M./P.M. (Date) (Time) by _ due to (Title) (Cause) The appropriate announcement was made or alarm sounded at A.M./P.M.,by (Time) (Title) The declared classification has been confirmed: Unusual Event by at A.M./P.M. (Title) .(Time) Sheet 1 of 4 i
,Os 10 EI 1300.04.4 Checklist l Alert by at A.M./P.M. t Site by a t. A.M./P.M. Gen'l. Emer by at A.M./P.M. Conduce. the necessary notifications to: i i UE ALERT SITE GE (Time / Int) (Time / Int) (Time / Int) (Time / Int) 1. Se.:cadary Alarm Station (SAS) i NOTE: In the event of a fire or medical emergency, the SAS 1 Operator will make calls for emergency support and/or notification of the following agencies or personnel. a. Fire Dept.(s) b. Emer. Medical Service (EMS) [ ) c. Edison Oper. ~ d. Magruder Hosp. e. St. Charles i Hospital L f. Life Flight 2. Nuclear Security Supervisor 3. Station Supt. NOTE: The Ottawa County Sheriff must be notified within 15 minutes of an emergency declaration. The Station Superin-tendent or his designee is responsible for this notification. a. The Ottawa County Sheriff was notified at A.M./P.M. by The message was given to , Title) (Name) ( The following Information was relayed: .~, l } .] t (1 Sheet 2 of 4 f
=-. ~. I 11 EI 1300,04.4 Checklist (Brief Summary) UE ALERT SITE GE (Time / Int) (Time / Int) (Time / Int) (Time / Int) 4. Key Emergency Re-sponse Personnel 5. NRC (via ENS) NOTE: The NRC must be notified within one hour of the declaration of an emergency classification and should be made by Station management. The initial information given to the NRC was received by: ,s, , and was as follows: ) d (Brief Summary) i Perform the applicable i steps of ECC Checklist EI 1300.08 Activated (Center activations are not required for each classification and may be omitted where applicable): a. ECC b. TSC c. OSC d. ESC l ~9 A . - }) v ~ Attachment I Sheet 3 of 4 i
12 EI 1300.04.4 Checklist UE ALERT SITE GE (Time / Int) (Time / Int) (Time / Int) (Time / Int) Conduct periodic up-dates for: a. TED Personnel b. NRC c. Ottawa County Sheriff / County E0C (REFER TO ATTAC1IME.Yr 2) As the condition is resolved, the classification is downgraded to: Site Alert at: A.M./P M. A.M./P.h. (' by: Unusual Event Declassified ac: A.M./P.M. A.M./P.M. by: When the condition is declassified, notify: a. TED personnel at A.M./P.M., by (Time) (Title) b. NRC at A.M./P.M., by (Time) (Title) c. Ottawa County Sheriff at A.M./P.M.,by (Time) (Title) REVIEWED BY FILED BY: Station Superintendent Emergency Planning Supervisor i ~,:1, I DI l rai Sheet 4 of 4 1 i
1 13 EI 1300.04.4 l, ED0/ SHIFT SUPERVISOR PERIODIC UPDATE RECORD FOR EMERGENCY EVENT Conduct period updates for: a. TED personnel at A.M./P.M.: b. NRC at A.M./P.M.: 4 c. Ottawa County Sheriff / County EOC at A.M./P.M.: Conduct periodic updates for: (, ~ /\\' TED personnel at A.M./P.M.: a. b. NRC at A.M./P.M.: 's c. Ottawa County Sheriff / County EOC at A.M./P.M.: J !l ? l 4' .L I 4 f '? ..J 1 i END Sheet 1 of 1 i f F
EI 1300.05.0 ) Davis-Besse Nuclear Power Station Unit No. 1 ~ Emergency Plan Implementing Procedure EI 1300,05 i General Emergency Record of Approval and Changes Prepared by C. J. Reed '5/30/80 Date Submitted by C. E. Wells 6/13/80 Section Head Date 6,+- 0 /3b. Reco= mended by SRB Chair:asi 'Date \\. QA Approved //!A Qualief Assurance Manager Date Approved.by N 'kN 2 Station Superintendent d Date Revision SRB QA Sta. Supt. No. Recommendation Date Approved Date Approved Date ( i /MP f&/o NA '0"'9)w '% as/P-z sw g a/nju pg ga,.=y 3 }w -3 olvltt. f runw: 3 t o b/N f JMy yye.2 gr ,am m awo 4 I. ~ ) 's; 4 1
-s 1 EI 1300.05.0 1. PURPOSE To outline the course of action and protective measures required to mitigate the consequences of a station emergency at the General Emergency level to safeguard Station personnel and the general public. 2. SCOPE Describes the actions and responsibilities of Davis-Besse personnel and offsite suppo'rt groups in the event of the Shift Supervisor declares a General Emergency in accordance with the Emergency Plan Activation procedure, EI 1300.01. i ' 3. REFERENCES I 3.1 Davis-Besse Nuclear Power Station Emergency Plan 3.2 Station Response to Emergencies, EI 1300.00 3.3 Emergency Plan Activation, EI 1300.01 3.4 Emergency Offsite Dose Estimates, AD 1827.10 3.5 Protective Action Guidelines, AD 1827.12 s f' ~) s 4. DEFINITIONS 4.1 General Emergency - Events are in progress or have occurred which involve actual or imminent substantial core degradation or melting with the potential for loss of containment integrity, and/or involve the potential release of radioactive particulates or gases offsite of a magnitude to exceed regulatory limits. i ] 5. EMERGENCY MEASURES 5.1 Shift Supervisor The Shift Supervisor, having assumed the role of interim Emergency Duty Officer and having classified the emergency as a General Emergency, shall assure the following actions are taken as required (See Attachment 1): h 5.1.1 Make the appropriate notifications or sound the appropriate alarm as necessary: a. Fire b. Containment Evacuation c. Initiate Emergency Procedures ,,N i 4
- C 7'
s m. s -y fm 3 EI 1300.05.4 NOTE: The announcement should b elude; % ' 1P the Emergency Action Level classification, 2) *-he level of response required,'and 3) a brief description of plant. conditions. s 3. The Shift Supervisor or his designee shall' then activate the pagers of the key emergency response personnel as listed in Administrative Memorandtan No. -37. 4. When paged (beeped), those individuals must telephone the Edison Operator who shall connect them with the Telephone Pager thus allowing them to hear the recorded message. 5. These individuals shall then," call in" or notify additional personnel as required to provide adequate response to the event by using Administrative Memorandum No. 37. NOTE: The NRC resident insepctor can be telephoned or paged in accordance (. - with AD 1827.17 if necessary. ,/ 5.1.4 Notification of the following agencies must occur: NOTE: When notifying an outside agency, record the name of the individual contacted and I request a return telephone call from the agency to verify notification. 4 a. Sheriff's Department, Ottawa County, within 15 minutes of an emergency declaration. T1.is notification can be accomplished by phone using either the conumercial number or an unlisted nuaiber provided for emergencies (both found in Admin. Mema 37) or by radio through CAS or SAS. b. NRC Region III, Office of Inspection and Enforcement; NRC, NRR, Emergency Incident Response Center, Bethesda, Maryland (This is accomplished by the NRC Emergency Notification Syst'em - Red Phone) within one hour. 5.1.5 Continue in the capacity of interim Emergency Duty Officer until relieved by the assigned Emergency Duty 4 Officer. In the event that the EDO cannot be contacted or does not arrive in a timely manner, the Shift Supervisor must complete those steps performed by the /, EDO, until relieved. b i J
m 5 EI 1300.05.1 1 / 5.2.2 Evaluate the information, data, and methods utilized by the Shift Supervisor in making his determination in order to ensure that the proper emergency classification has been made. 5.2.3 Activate the ECC according to the Emergency Control Center Activation procedure, EI 1300.08. 5.2.4 Continue assessment acticas initiated by the Shift Supe rvisor. ~1 5.2.5 Confer with the Emergency Operations Manager concerning distributi6n 6f a thyroid blocking agent to those TECo emergency workers involved in the Station response as ~ specified in AD 1827.12, Protective Action Guidelines. 5.2.6 Recommend protective actions to the Ottawa County Sheriff as required by assessment results per AD 1827.12, Protective Action Guidelines. 5.3 Shift Operations Personnel 5.3.1 Control Room operators shall maintain safe operations of the Station and minimize the potential hazards to Station personnel and the general public as directed [:s( by the Shift Supervisor. 5.3.2 In the event that the Shift Supervisor is incapacitated, his duties and responsibilities indicated in Step 5.1 shall be assumed by the Assistant Shift Supervisor in the Control Room until relieved by a qualified Shift i Supervisor. 5.3.3 Equipment and auxiliaries operators shall maintain safe operations of the plant as directed by the Shift Supervisor. l 5.3.4 The Shift Technical Advisor shall provide technical and analytical support in the diagnosis of off-normal events. He shall also advise and assist the Shift Supervisor on matters pertaining to the safe and [ proper operation of the plant with regards to nuclear safety. i 5.4 Shift Chemistry and Radiation Tester (C&RT) 5.4.1 The shift C&RT shall report immediately to the Health Physics Monitoring Room to await instructions from the Shift Supervisor or Chemist and Health Physicist. T rJ: I l
7 EI 1300.05.3 fs s / t 5.7.2 Nuclear Security Officers shall maintain security ~3 of the Station as directed by the Nuclear Security Supervisor. 5.8 Radiation Monitoring Team (RMT) 5.8.1 All qualified non-chemistry and health physics RMT members will report to the turbine deck assembly area adjacent to the OSC.
- 5. 8.2 ~
The OSC Manager will designate RMT members as to their assignment as offsite or onsite.
- a. A list of qualified RMT's is found in Administra-tive Memo 42.
3
- b. Only one member of each team should be from the C&HP section.
5.8.3 If requested by the EDO, offsite RMT's will be dispatched to the Radiological Testing Laboratory (RTL) for further instructions. 5.8.4 RMT's responding from offsite will report to the RTL for further assignment. i ) 5.9 Plant Staff Members of the plant staff that have been informed of a Site Emergency shall proceed to their designated loca-tions and perform their assigned functions. 5.9.1 The Plant Operations Manager shall proceed to the Control Room. Ha shall direct plant opera-tions and plant damage control efforts. He shall also keep the Station Cperations Manager advised _ of plant operations and plant damage control efforts. 5.9.2 The Operations Engineer shall proceed to the Control Room. His functions are to supervise control room. activities, to perform on-the-spot operational analysis as required to assist the a i Shift Supervisor, and keep the Plant Operations l, Manager informed of current plant conditions. !~ 5.10 Onsite Personnel 3 5.10.1 Personnel, who do NOT have specifically assigned duties shall proceed to areas as prescribed in AD 1827.11 Assembly, Accountability, and Subsequent j ,e Evacuation. (' i ?, -
~ 4'
- L.
' ' ~ ' 1 9 EI 1300.05.2 6.2 The Emergency Duty Officer shall assure notification of all offsite organizations and TEco personnel that the emergency has terminated. 2 6.3 A written summary will follow notification of termination within 8 hours. I e oe I e 9 6 4
- s
,. / e 1 i k- 'h i .J ai i s ~ e 4 1-( -;*Q$ .1 1
10 EI 1300.05.4 ~ \\ ? ELO/SMIFT SUPERVISOR CHECKI.IST FOR EMERGENCY EVENT An Unusual Event (UE) was declared on at A.M./P.M. (Date) (Time) by due to 3 (Title) (Cause) The appropriate announcement was made or alarm sounded at ? A.M./P.M., by (Time) (Title) ~ i An Alert was declared on at A.M./P.M., by (Date) (Time) (Title) due to (Cause) The appropriate anncuncement was made or alarm sounded at A.M./P.M., by (Time) (Title) / A Site Emergency was declared on at A.M./P.M. s'"' (Date) (Time) 'by due to (Title) (Cause) The appropriate announcement was made or alarm sounded at il A.M./P.M. by si (Time) (Title) i Lj A General Emergency (GE) was declared on at A.M./P.M. (Date) (Time) k! by due to 4-(Title) (Cause) c The appropriate announcement was made or alarm rpve.ied at 'll A.M./P.M. by ,j (Time) (Title) The declared classification has been confirmed: 1 Unusual Event by at A.M./P.M. (Title) E(Time) c'- Sheet 1 of 4 f +
.1. ~ 11 EI 1300.05.4 s Checklist Alert by at A.M./P.M. Site by at A.M./P.M. l' Gen'l. Emer by at A.M./P.M. Conduct the necessary notifications to: UE ALERT SITE GE ~ (Time / Int) (Time / Int) (Time / Int) (Time / Int) 1. Secondary Alarm Station (SAS) NOTE: In the event of a fire or medical emergency, the SAS Operator will make calls for emergency support and/or notification of the' following agencies or persoanel. a. Fire Dept. (s) b. Emer. Medical Service (EMS) j c. Edison Oper. . ~~> d. Magruder Hosp. e. St. Charles Hospital I f. -Life Flight 2. Nuclear Security Supervisor l 3. Station Supt. NOTE: The Ottawa County Sheriff mest be notified within 15 j minutes of an emergency declaration. The Station Superin- } tendent or his designee is responsible for this notification. a. The Ottawa County Sheriff was notified at A.M./P.M. j i by The message was given to i (Title) (Name) j The following information was relayed: q Sheet 2 of 4 e
_? ~~~ ^ 12 EI 1300.05.4 Checklist (Brief Summary) UE AI.ERT SITE GE (Time / Int) (Time / Int) (Time / Int) (' Time / Int) 4. Key Emergency Re-sponse Personnel 5. NRC (via ENS) NOTE: The NRC must be notified within one hour of the declaration of an emergency classification and should be made by Station management. The initial information given to the NRC was received by: , and was as follows: (,. /) (Brief Summary) Perform the applicable steps of ECC Checklist EI 1300.08 I Activated (Center activations are not required for each classification and may be omitted where applicable): a. ECC i b. TSC c. OSC j d. ESC i . ',l Sheet 3 of 4 .]
4. a. o.. ~. ^^~ ~ } I' 'l 13 EI 1300.05.4
- j Checklist
~ UE ALERT SITE GE (Time / Int) (Time / Int) (Time / Int) (Time / Int) Conduct periodic up-dates for: a. TED Personnel b. NRC g y! c. Ottawa County g Sheriff / County EOC
- s j
(REFER TO ATTACHMENT 2) As the condition is resolved, the classification is downgraded tc: Site Alert at: A.M./P.M. A.M./P.M. q by: Unusual Event Declassified a at: A.M./P.M. A.M./P.M. by: When the condition is declassified, notify: il a. TED personnel at A.M./P.M., by ] (Time) (Title) .j. b. NRC at A.M./P.M., by 4 (Time) (Title) t-l c. Ottawa County Sheriff at A.M./P.M.,by j. (Time) (Title) i REVIEWED BY FILED BY: Station Superintendent Emergency Planning Supervisor ii , ?l~s %:3 [ Sheet 4 of 4 k I ~ [
f~. s --n i a
- j 14 EI 1?>0.05.4 a
3 I sz, ? ED0/ SHIFT SUPERVISOR PERIODIC UPDATE RECORD FOR EMERGENCY EVENT Conduct period updates for: A.M.'P.M.: a. TED personnel at / P t LI b. NRC at A.M./P.M.: 'i c. Ottawa County Sheriff / County EOC at A.M./P.M.: '.,t Conduct periodic updates for: [a.0-)
- i
(' -./ a. TED personnel at A.M./P.M.: w i ] b. NRC at A.M./P.M.: 1 i 1 f7 1 c. Ottawa County Sheriff / County EOC at A.M./P.M.: V ~ i i I 1,. ' 2.- ls 'r END Sheet 1 of 1 1' ~ t. .,_..,------,,,..-_,.-,v, ,_ -,-,.,-. -,-..._... _..-._,- - ~-,--.,-. .. -. -.. -. - - - -}}