l
~
e t
Cecil 0. Thomas 38-4045 The reactor effluents for 1982 have not changed significantly from those used in the Environmental Assessment Report dated 7/19/81 which shows the radiological impact of the San Diego site operations including the TRIGA reactors are insignificant. The results of the annual environmental survey are included as part of the environmental assessment.
Part 8 - Revised 5/83 A summary of radiation exposures received by facility personnel and visitors, including the dates and time of significant exposure, and a brief summary of the results of radiation and contamination surveys performed within the facility.
Facility Personnel Whole Body Exposures for the Year 1982 (Rem):
Number of Employees Monitored High Low Average 3
1.420" 0.200 0.840 Nonfacility GA Personnel Whole Body Exposures for the Year 1982 (Rem):
Number of Persons Monitored 54 0.420' O.000 0.049 Contractor Personnel Whole Body Exposures for the Year 1982 (Rem):
Number of Persons Monitored 36 0.220 0.000 0.016 Visitor Whole Body Exposures for the Year 1982 (Rem):
Number of Persons Monitored High Low Average 47 0.050 0.000 0.001
(" Employee also worked at other facilities on GA site).
Routine Wipe Surveys 2
High Wipe 2100 8 dpm/100 cm2 Average Wipe
<26 8 dpm/100 cm2 Low Wipe
<25 8 dpm/100 cm Routine Radiation Measurements High 160 mR/hr Average 2
mR/hr Low
<1 mR/hr 8308030314 930729 PDR ADOCK 05000089 R
PDR l