RO 78-08/1P:on 780202,deviation Discovered Between Parameter Assumption Used in FSAR Steam Line Break Anaylsis & Actual Operating Parameters.Procedures Modified,Limiting Secondary Side Water Inventory to within SAR Analysis
ML20024C636
Person / Time
Site: Crane 
Issue date: 02/02/1978
From: Kunder G
METROPOLITAN EDISON CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20024C637 List:
References
TASK-*, TASK-02, TASK-2, TASK-GB GPU-2036, RO-78-081-1P, RO-78-81-1P, NUDOCS 8307120912
Download: ML20024C636 (1)


Text

_

S---u TbE\\

WZ/

MT

~

f

.C

- 4 M '!;;;r7;J f

Y,E e i,

METROPOLITAN EDISON COMPANY..munvo asusuuvsueununsscon.ouno.y POST OFFICE BOX 480 MIDDLETOWN. PENNSYLVANIA 17057 TELEPHONE 717 944-4041

(

February 2, 1978 Mr. Boyce H. Grier Directorate of Regulatory Operations Region I

(-

Nuclear Regulatory Comission 631 Park Avenue King of Prussia, Pennsylvania 19406 Operating License DPR-50 Docket 50-289

Subject:

Reportable Occurrence No. 78-08/1P

Dear Mr. Grier:

This telegram is to confirm the telecon between Mr. E. Brunner, Region I NRC, and Mr. G.A. Kunder, Unit I Superintendent Technical Support, at 18:15 hours

(,

on 2 February 1978.

This item is considered reportable in accordance with Technical Specification-6.9.2.A.9.

On 2. February 1978, Met-Ed was informed by the Unit 1 NSS supplier that a deviation was discovered between a parameter assumption used in the Unit 1 Steam Line Break Analysis in Chapter 14 of the FSAR and an actual operating parameters.

The OTSG is normally operated with the secondary side feedwater nozzles submerg-ed below 5% full power in order to avoid longterm feedwater nozzla thermal effects.

The water inventory existent during this' mode is greater than that assumed in the Steam Line Break Analysis and,-therefore, represents an unanalyzed condition.

Corrective action will include procedure modification to prevent operation in the above manner such as to limit the secondary side water inventory to within the values assumed in the safety analysis.

g y-}yf G.A. Kunder Unit I Superintendent, Technical Support GAK/dcr.