P Omaha Public Power District l

1623 Harney Omaha, Nebraska 68102 402/536 4000 July 1, 1983 LIC-83-141 Mr. Robert A. Clark, Chief U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Licensing Operating Reactors Branch No. 3 Washington, D.C.

20555

Reference:

Docket No. 50-285

Dear Mr. Clark:

Fort Calhoun Station Eddy Current Testing Report The Omaha Public Power District performed eddy current testing on Fort Calhoun Station steam generators ' A' and 'B' during the 1983 refueling outage.

In accordance with Fort Calhoun Station Technical Specification 3.3(2)e.(fi), please find enclosed the report entitled " Steam Generator Tube Eddy Current Inspection Report, Steam Generator ' A' and 'B',1983 Refueling Outage."

Si nce. rely,

)

i[h W. C.cJones Divis{on Manager Production Operations WCJ/TLP:jmm Enclosure cc:

LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, N.W.

Washington, D.C.

20036 l

Mr. E. G. Tourigny, l

NRC Project Manager Mr. L. A. Yandell, Senior Resident Inspector 9

8307120482 830701 l

PDR ADOCK 05000285 G

PDR

_ entgn aua opportunity ds 5:24