s vuiseensw w -*w.wm q 8
LONG ISLAND LIGHTING COMPANY l
ij SHOREHAM NUCLEAR POWER STATION r
- ,--mm%#J P.O. BOX 618, NORTH COUNTRY ROAD. WADING RIVER, N.Y.11792 D' nt Dial Number m
June 27, 1983 SNRC-920 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Transmittal of the Monthly Status of the Equipment Summary List SER Issue No.
8, Dynamic Qualification Shoreham Narlear Power Station - Unit 1 Docket No. 50-322
References:
1.
NRC letter (A. Schwencer) to LILCO (M. S.
Pollock),
dated November 10, 1982, " Trip Report for Second Seismic Qualification Review Team (SQRT) Plant Site Audit" 2.
LILCO letter, SNRC-796, (J.
L. Smith) to the NRC (H.
R. Denton), dated November 23, 1982
Dear Mr. Denton:
As discussed in the referenced letters, LILCO committed to provide a monthly statusing of the equipment summary lists including BOP and NSSS equipment to assist the NRC in their review of this issue.
This letter transmits ten (10) copies of the latest " List of Active Safety-Related Equipment at Qualification Level".
In accordance with R.
L. Tedesco's letter to LILCO dated January 28, 1981, four copies of this submittal are being forwarded directly to Dr. Morris Reich at Brookhaven National Laboratory.
mm Should you have any questions, please contact this office.
bno NME gg Very truly yours,
~
4 J.
L. Smith Manager, Special Projects n<
Shoreham Nuclear Power Station o
<Q g DWD:bc Attachment
\\
cc:
J.
Higgins (hh All Parties Listed in Attachment 1 Dr. Morris Reich, BNL, (4) l l0 FC-8935.1
ATTACHMENT 1 Lawrence Brenner, Esq.
Herbert H., Brown, Esq.
Administrative Judge Lawrence Coe Lanpher, Esq.
Atomic Safety and Licensing Karla J. Letsche, Esq.
Board Panel Kirkpatrick, Lockhart, Hill U.S. Nuclear Regulatory Commission Christoper & Phillips
~
Washington, D.C.
20555 8th Floor 1900 M Street, N.W.
Washington, D.C.
20036 Dr.. Peter A. Morris Administrative Judge Atomic Safety and Licensing Mr. Marc W. Goldsmith Board Panel Energy Research Group U.S. Nuclear Regulatory Commission 4001 Totten Pond Road Washington, D.C.
20555 Waltham, Massachusetts 02154 Dr. James H. Carpenter MHB Technical Associates Administrative Judge 1723 Hamilton Avenue Atomic Safety and Licensing Suite K Board Panel
. San Jose, California 95125 U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Stephen B.
Latham, Esq.
Twomey, Latham & Shea Daniel F. Brown, Esq.
33 West Second Street Attorney.
P..O.
Box 398 Atomic Safety and Licensing Riverhead, New York 11901 Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Ralph Shapiro, Esq.
i Cammer and Shapiro, P.C.
l 9 East 40th Street l
Bernard M. Bo-denick, Esq.
New York, New York 10016 David A. Repka, Esq.
U.S. Nuclear Regulatory Commission Washington, D.C..
20555
' Matthew J.
Kelly, Esq.
State of New York James Dougherty.
Department of Public Service Three Empire State Plaza 3045 Porter Street Albany, New York 12223 Washington, D.C.
20008
_.--..,...,----.ww--
SHOREHAHUN3/)1 STONE & HEBSTER EffGINEERIEJ'LORPORATI0tl RUti DATE 06/22/&3
- )
C3 LIST JOB hut 2ER 11600 1-50RT C0tliROL DUILDING CATEGORY I EQUIPitEtiT RUtl TIllE 09.50.19
- (-
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0ft LEVEL (218 ITEllS)
PAGE 1
~
i ilARH EQUIPitENT SPEC DIV.
BLOG AVAIL QUAL QUAL TYPE SAFE QUAL t4UltBER DESCRIPTION ttO.
RESP VENDOR ELEV IllSP REPT llETH FREQ IITilG SitTON STA1US.
(
IB21mPitU-501 TRIP /CALIS UNIT 406 CD ROSEll0UtlT 063 YES 127531 SAT 57+
F H
H 1821mTE-037 MI STH LINE TURS AREA 406 CD ROSEll0UNT 042 YES 2767 SAT 35+
F4 CS.itS H
- (.
ID11mPit-021 RBS8VS HONITORING PANE 332 PD t#C 063 YES 45493-1 ItBT 13 F
N H
ID11mPFL-022 RBSBVS It0NITORING PANE 332 PD MC 063 YES 45493-1 ItDT 13 F
N H
ID11mPNL-025 CONT RO0tt HONITOR PNL 332 PD MC 044 YES 45493-1 HDT 14 F2 N
H 2
1011mPtL-026 C0 TIT ROOli Itot4ITOR PIL 332 PD talc 044 YES 45493-1 HBT 14 F2 H
H 1011mPPL-027 C0flT Ril vel 4T H0tlIT PtL 332 PD MIC 043 YES 45493-1 ItDT 13 F
H H
ID11mPit-066 POST ACCOUNT tt0N 332 PD NitC 063 YES 45493-1 flBT 14 F
N H
.b 1011mPit-067 POST ACCDNT HONITORS 332 PD MIC 063 YES 45493-1 HDT 14 F
II H
1011mPtL-068 POST ACCDilT It0NITORS 332 PD MtC 063 YES 45493-1 ItBT 14 F
fl H
1011mPIL-049 POST ACCDilT H0tlITORS 332 PD NitC 063 YES 45493-1 IfDT 14 F.
H H
I 1011mPit-080 RAD flott PIL 332 PD MtC 063 YES 45493-1 HDT 6
F2 H
H b
1011mPFL-117 RAD 110N SYS IND 475 PD HA!!AN 063 YES H-83-1-UIR)
SA 27 F2 H
F 4
1011mPIL-126 STA VENT ff0HITOR 475 PD HAllAN 063 YES 16435 ftBT 4
F H
H lL/
ID11mPtL-134 RB SVS llO!IITOR 475 PD HAftAN 113 YES 16435 HBT 4
F H
H 1011mPtL-135 HICROColtP FOR PNL126 475 PD HAttAtt 063 YES 16435-A ltDT 19 F
fl H
4 lb 1D11mPtt-137 HICROCOttP FOR PtL134 475 PD HA!!AN 063 YES 16435-A ItDT 19 F
fl H
1G11mLTS-642 TH56 LEVEL 473 CD DELAVAL 063 YES 45700-1 HBT 14 F
N H
!b 1G11mLTS-645 R8 FLOOD LEVEL 473 CD DELAVAL 043 YES 45700-1 IIDT 14 F2 H
H IH11mitCD-01 IIAIN CONTROL BOARD 120 CD RELIANCE 063 YES 43331-1 SA/ttST 16 F
CS.HS H
- V l
_ 1H11mPFL-ACI H2402 ANAltPST ACC SAH 125 CD RELIANCE 063 RCAP-001-0 SA 13 F
CS B
t A/ ~ CS = COLD SHUT DCllti P = PIPE HourtTED SBT= SINGLE FREQUENCY OUALIFICATION HILEST0tlES REVISION 11 - JUtiE 1983 j
DA =DY!!AtlIC AtlALYSIS a TEST ARTICLE DIAXIAL TESTIllG A =REEVALUATIOtl CottPLETE F = FLOOR lf0UtlTED D = REQUEST FOR QUAL OR DID ISSUED #101E: flutt0ER Iti HS = HOT STATIDBY QP = QUALIFIED DY tl =NEITHER CS OR HS C =S/H REC 0ttilEllDATIOti TO LILCO
' TYPE IITitG' COLUttN IS
%p l!3T=ltULTI-FREQUEtiCY PIPItiG AtlALYSIS D = QUAL 00C RECEIVED QUAtiTITY OF ITEllS.
l DIAXIAL TESTIttG SA = STATIC AtlALYSIS E =llARDHARE il00IFICATION REQ'O f tST=ltULTI-FREQUEllCY SAT = sit 4GLE FREQUEtiCY F = QUAL DOC APVD 1 FILED SIllGLE AXIAL TESTING SIllGLE AXIAL TESTING.
G =SQRT PAPER C0ttPLETE 4/.
H = COPIES OF DOC TO DISTRIDUTION w
SHOREHAH UNTT 1 C3 LIST STDHE & HEDSTES ENGINEERING CORPORATION RUN DATE 06/22/23 JOB flullDER 11600 1-SORT C0tlTROL DUILDING CATEGORY I EQUIPitEllT RUN TIllE 09.50,19
(
'LILCD DOCHET 50-322 ACTIVE CDP QUALIFICATION LEVEL (Ele ITERIS)
PAGE 2 ftARN EQUIPitENT SPEC DIV.
DLDG AVAIL QUAL QUAL TYPE SAFE QUAL HutIDER DESCRIPTI0tl HD.
RESP VEtIDOR ELEV INSP REPT ttETit FREQ liitG SHTON STATUS L
lil11mPNL-AC2 H2&D2 ANAL &PST ACC SAN 125 CD RELIAtKE 063 RCAP-001-0 SA 13 F
CS B
1H11mPFL-BR1 BUFFER RELAY CAS 125 CD RELIAtlCE 044 YES 99AX400536' SA/ItST 37 F
C5.HS B
1H11pFIL-ItXP tlISC C0flTROL PANEL 125 CD RELIANCE 063 YES 99AX400590 SA/itST 17 F
CS.HS B
1H11mPit-PCH PRI CONT ttONITOR PANEL 125 CD RELIAtlCE 063 YES 9?AX400666 SA/ttST 14 F
H B
(.
1H11mPtL-VC1 TB & IIISC VElli 125 CD RELIAt4CE 063 YES 99AX400536 SA/ttST 17 F
CS B
1H11mPFL-VC2 RB VENT 125 CD RELIANCE 063 YES 99AX400536 SA/itST 17 F
CS B
k IH21mPtL-AX1 AUX RELAY 125 CD RELIAtKE 044 YES 99AX400590 SA/ftST 32 F
CS.HS B
1H21mPit-AX2 AUX RELAY 125 CD RELIAtlCE 044 YES 99AX400590 SA/ttST 32 F
CS.HS B
U 1H21mPit-AX3 AUX R R A.* PANEL AX3 125 CD RELIAtlCE 063 YES AAI-131 SA/ttST 22 F
C5.HS B
1H21mPtL-AX5 AUX RELAY PAtlEL AXS 125 CD RELIAtlCE 063 YES AAI-131 SA/itST 22 F
CS.HS B
lil21mPit-AX6 AUX RELAY PAtlEL AX6 125 CD RELIAtlCE 063 YES AAI-131 SA/ItST 22 F
CS ells D
1H21mPla-VXI VENT AUX RELAY 125 CD RELIANCE 044 YES 99AXO536-VX1 SA/ItST 34 F
CS its 8
1H21mPFL-VX2 VENT AUX RELAY 125 CD RELIANCE 044 YES 99AX0536-VX1 SA/itST 34 F
CS.HS B
1H21mPtL-VX3 VENT AUX RELAY 125 CD RELIANCE 044 YES 99AX0536-VX1 SA/ttST 23 F
CSelts B
Y lil21=PIL-060 ELEC AtlAL IrlSTR RN 125 CD RELIAtlCE 044 YES 99AX400679 SA/ttST 33 F
CS.HS H
lit 43mHS003 FIRE DET SH STA 319 ED P0HERS REG 044 YES 43812-1 PET 24 F3 CS.IIS H
ltl43 mils 006 FIRE DET SH STA 319 ED POHERS REG 025 YES 43012-1 IST 24 F3 CS.HS H
litq3ePNL-C01 CO2 DETEC Pit RELAY R1 238 PD RELIANCE 044 YES 44204-1 stBT 17 F2 H
H lil43mPit-C02 CO2 SUPVR PIL DATTERY 238 PD RELIANCE C25 YES 44204-1 ItDT 17 F
M H
lil43mPIL-C03 CO2 SUPVR PtL BATTRY R 238 PD RELIANCE 025 YES 44204-1 IST 17 F
H H
V
_ 11143mPtL-C04 CO2 SUPVR PIL BATTRY R 238 PD RELIANCE 025 YES 44204-1 IST 17 F
H H
U CS = COLD SifUT DOHit P = PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION ttILESTollES REVISI0tt 11 - JUtlE 1983 g
DA =DYllAllIC AtlALYSIS
- TEST ARTICLE BIAXIAL TESTIllG A = REEVALUATION C0ttPLETE F = FLOOR ltGut4TED D = REQUEST FOR QUAL CR DID ISSUED NOTE: totCER Iti IIS =110T STAtIDDY QP = QUALIFIED BY H =NEITHER CS OR HS C =S/H REC 0f tflEllDATIOff TO LILCO
' TYPE IITilG* COLUtiti IS V
IIDT:ltULTI-FREQUEtiCY PIP 1HG AtlALYSIS D = QUAL DOC RECEIVED QUAtlTITY OF ITEllS.
g BIAXIAL TESTItG SA = STATIC AtlALYSIS E =HARDilARE It0DIFICATI0ft REQ'O SitST=ltULTI-FREQUENCY SAT =SitlGLE FREQUEtlCY F = QUAL DOC APVD & FILED SINGLE AXIAL TESTING SINGLE AXIAL TESTINGL G =SO9T PAPER C0ttPLETE Q
H = COPIES OF DOC TO DISTRIBUTI0tl s
a
7 7m
(
)
(
h SHOREHAI)LUT1 C3 LIST STortE & HELSTE'? EllGINEE-CORPORATION RUti D'.TE 06/22/23 JOB futDE2 11600 1-SORT CONTROL BUILDING CATEGORY I ECUIPitENT RUtt TIttE 09.50.19
('
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0H LEVEL (218 ITEllSI PACE 3 ftARK EQUIPitENT SPEC DIV.
ELDG # VAIL QUAL QUAL TYPE SAFE QUAL tutDER DESCRIPTION HO.
RESP vet 1 DOR ELEV It4SP REPT ITETH FREQ llTriG SitTDN STATUS Ill43 nPtL-C05 CO2 SUPVR PFL DSL RH 1 238 PD RELIAtlCE 015 YES 44204-1 HDT 17 F
H H
lil43mPtL-C06 CO2 SUPVR PtL DSL RM 1 238 PD RELIAf4CE 015 YES 44204-1 ItBT 17 F
H H
lit 43mPtt-C07 C02 SUPVR PtL DSL Ril 1 238 PD RELIAt4CE 015 YES 44204-1 ItBT 17 F
N H
lil43aPtL-C08 CO2 SUPVR PtL EttER SHG 238 PD RELIAtlCE 025 YES 44204-1 110T 17 F
tl H
lil43aPtL-C09 CO2 SUPVR PIL EftER SHG 238 PD RELIAtlCE 025 YES 44204-1 ftST 17 F
H H
lit 43aPtL-C10 CO2 SUPVR PIL EltER SHG 238 PD RELIAtiCE 025 YES 44204-1 ItDT 17 F
H H
ll!43nPit-C11 CC2 SUPVR Ptt Cot lPUTER 238 PD RELIArtCE 044 YES 44204-1 ttDT 17 F
H H
lits 0mAOV062 RDSVS & CRAC 423 CD FISifER 071 YES C076-82 SAT 23 P2 CS.HS 11 Ill50mAOV063 RBSVS & CRAC 423 CD FISilER 071 YES CD76-82 SAT 23 P2 CS.HS H
lil50mA0V068 CHILLED HTR ISO BY 318 CD COPES VULCAN 071 YES 10.3.115 SA 124 P2 CS.HS H
k.
Ilt50eA0V069 CHILLED HTR ISO BY 318 CD COPES VULCA!4 075 YES 10.3.115 SA 124 P2 CS.HS H
11150=FT-043 HC-3 EVAP 406 CD ROSEttor8T 063 YES 127516 SDT 50 F2 CS.HS H
U lit 50 m FT-053 lic-4 EVAP 406 CD ROSEtt0HT 063 YES 127516 SBT 50 F2 CS.HS H
lt50nLCV025 CH SYSTEll A ItAHEUP 318 CD COPES VULCAN 072 YES 10.3.115 SA 124 P2 CS.HS 11 b
lil50*LS 002 ISOL BYP V A0V68A.69A 407 CD llAGriETROL 063 YES 43235-1 ftDT 17 F2 IIS H
litSO.LS 025 CH SYSTEll A StAMEUP 407 CD ltAGitETROL 063 YES 43235-1 ItDT 17 F2 HS H
(-
ltt50mtlOV031 CH RETURtl 197 PD PRATT 071 YES D-0034-7 SA 394 P2 CS.IIS H
lil50ett0V032 CH SUPPLY 197 PD PRATT 075 YES D-0034-7 SA 394 P2 CS.HS H
lil50all0V033 CH RETURN CROSSOVER 197 PD PRATT 071 YES D-0034-7 SA 394 P2 C5 tis H
!!!50ett0V034 CH SUPPLY CROSSOVER 197 PD PRATT 075 YES D-0034-7 SA 394 P2 CS.HS H
_Ill50mP-13 7 RBSVS & CRAC CH PUltPS 62G PD GOULD PUf!PS 063 YES ltE-326 SA 81 F2 CS its H
V CS = COLD SHUT DOHit P = PIPE lt0UHTED SDT= SINGLE FREQUEtiCY QUALIFICATIOtt itILESTCtlES REVISI0tt 11 - JUttE 1983 OA =0YllAtlIC AtlaLYSIS w TEST ARTICLE DIAXIAL TESTIriG A - REEVALUATI0tt C0f tPLETE F = FLOOR 110UtiTED D = REQUEST FOR QUAL OR DID ISSUED tiOTE: ifUttDER Ill HS =llOT STATIDDY QP = OUALIFIED BY ft =HEITHER CS OR HS C =S/H REC 0!!!!Ett0ATI0tl TO LILCO
' TYPE flTHG' COLUttfl IS V
ttDT=llULTI-FREQUENCY PIPIllG AHALYSIS D = QUAL DOC RECEIVED QUAllTITY OF ITEllS.
DIAXIAL TESTIttG SA = STATIC AtlALYSIS E =tlARDHARE It0DIFICATIOil HEQ'D IIST=ltULTI TREQUEHCY SAT =SItlGLE FREQUENCY F =0UAL DOC APVO & FILED SitiGLE AXIAL TESTING SItICLE AXIAL TESTItIG G =SQRT PAPER C0ftPLETE
- V ll = COPIES OF DOC 10 DISTRIBUTI0ft
~
c O
J O
SHOREHAH UNIT 1 C3 LIST STONE & HEISTER ENGIHEERING CORPORATIDH RUte DATE 06/f2/83 JOB NUlI:ER 11600 1-SORT C0tiTROL BUILDING CATEGORY I EQUIPl1ENT RUtl Title 09.S0.19 b
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (218 ITEltS)
PAGE 4 HARN EQUIPHENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL HUllDER DESCRIPTION HO.
RESP VEtt00R ELEV IttSP REPT llETil FREO IITNG SitTDH STATUS ill50mP-138 RBSVS & CRAC CH PUllPS 62G PD GOULD PUIPS 063 YES ItE-326 SA 81 F2 CS.HS ll ill50mP-139 RBSVS & CRAC COND PUltP 62H PD HORTHINGTott 063 YES DHA-000047 SA 31 F2 CS.HS H
lil50mP-140 RDSVS & CRAC COND PUllP 62H PD HORTHINGTON 063 YES DHA-0000t47 SA 31 F2 CS.HS H
lits 0 nPCV019 RSSV HSO DIFF PRESS 310 CD FISHER C0tlTROL 063 YES 2-24451 SA/ SAT 25 P2 CS H
Ill50mPDT019 RBSVS 1t50 DIF PR 406 CD ROSEliotiT 063 YES 127516 SBT 50 F2 CS.HS H
Ill50mPHL-03 CHILLER CONTROL PANEL 106 PD TRAHE CO 063 YES NUC-102 SA 13 F2 CS.HS H
(
ll!50mPill-04 CHILLER CONTROL PANEL 106 PD TRANE 063 YES tFJC-102 SA 13 F2 CS.HS H
a lits 0nRV091 CllILLED H2O SURGE TH88 191 CD L0ttERGAN 072 YES 5026tl4 SA 60 P2 CS ell 5 H
k lits 0mTE 089 RBSVS CHILLED HTR SYS 406 CD ROSE 110UllT 078 YES 2767 SAT 35+
F2 CS.HS H
I lil50mTH-088 RBSVS & CRAC-SURGE TAN 114 PD BUFFALO TAPH 063 YES tittlB)-122-IA SA 45 F2 CS.HS H
lil50mHC-003 ROSVS & CRAC HTR CHILL 106 PD TRANE CD 063 YES ttUC-102 SA 31 F2 CS.HS H
lit 50mHC-004 ROSVS & CRAC HTR CHOLL 106 PD TRANE CD 063 YES HUC-102 SA 31 F2 CS.HS H
IH11ml10V031 2HD STAGE REHEAT STH 80V PD VELAN 051 YES SR-6262 SA/ SAT 33*
P2 HS H
lit 11mit0V036 ftISC STil FROH 110R ISO 88V PD VELAri 051 YES SR-6262 SA/ SAT 33+
P HS H
- !b a
ltl11stl0V041 AUXILIARY S1EAH SUPPLY 88V PD VELAN 051 YES SR-6181 SA/ SAT 33+
P CS H
IPt:1mA0V016 DIESEL HX E-13A OUTLET 423 CD FISliER 025 YES CD76-82 SA 23 P3 CS H
(
IP41mFT 054 HC-3 COND HTR IN 406 CD ROSEll0NT 063 YES 127516 11BT 60+
F2 CS.HS H
l IP41mFT 059 HC-4 COND HTR IN 406 CD ROSEll0NT 063 YES 127516 ftBT 40+
F2 CS.HS H
L IP41 mil 0V036 A VT CilILL HTR SPLY ISOL 197 PD PRATT 012 YES D-00384-3 SA 33+
P CS.HS H
IP41mit0V0368 VT CHILL HTR SPLY ISOL 197 PD PRATT 012 YES D-0034-3 SA 33+
P CS.HS H
V s
_ 1P41 sit 0V036C VT CHILL HTR SPLY ISOL 197 PD PRATT 050 YES D-0034-4 SA 297 P
CS.HS H
A/ CS = COLD SilUT DOHN P = PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISI0tl 11 - JUttE 1983 y
DA =DYHA!!IC AtlALYSIS w TEST ARTICLE BIAXIAL TEST 1HG A =REEVtLUATI0tt ColtPLETE F = FLOOR llOutlTED B = REQUEST FOR QUAL OR BID ISSUED tlOTE: HUttDER IN l
Ils = HOT STATIDBY QP = QUALIFIED BY H =NEITHER CS OR HS C =S/H REC 0ttffEttDATIDH TO LILCO
' TYPE ltTilG' COLUtIN IS
%r itBT=ltULTI-FREQUEllCY PIPING ANALYSIS D = QUAL 00C RECEIVED QUAT 4TITY OF I1 Ells.
s BIAXIAL TESTIttG SA = STATIC AtlALYSIS E =HtIDil@F.ItCDIFICATTON REQ'D IllST=ttULTI-IREQUEttCY SAT = SINGLE FREQUEllCY F = QUAL 00C APVD & FILED j
1 SIttGLE AXIAL TESTING SINGLE AXIAL TESTING G =SQRT PAPER CottPLETE
, 4p H = COPIES OF DOC TO DISTRIBUTION s
i
k SHOREHAH h IT 1 CB LIST STONE & HEBST[;f Et4GINEERING CORPORATIOi!
RUN DATE 06/22/83 JOB P49t2E2 11600 1-SORT C0tI1ROL DUILDIllG CATEGORY I EQUIPitEllT RUN TIltE 09.50.19 i
(
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL (218 ITEllS)
PAGE 5 ftARN EQUIPitENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE StFE QUAL Null 0ER DESCRIPTION tio. RESP VENDOR ELEV ItiSP REPI HETH FREQ ttitlG SHTDif STATUS
.]P41mPS 008 SUCTION 1H50mP-1398 348 CD ASCO 063 YES 178 SAT 50+
F2 CS.HS 11 IP41mPS 009 SUCTION lif50mP-1408 348 CD ASCO 063 YES 178 SAT 50+
F2 C3.HS H
IP41 MRV 019 OUTLET DIESEL HX-13 191 CD LONERGAN 028 YES 502644 SA 60 P3 CS.HS H
IP41 MRV 064 CNTRL Ril & ROSVS HC-3 191 CD LONERGAtl 072 YES 502644 SA 60 P2 itS H
IP41 MRV 065 CNTRL RH 1 RBSVS HC-48 191 CD LOffERGAN 072 YES 502644 SA 60 P2 IIS H
1 1P41mTCV055 Ct4TRL RH & RBSVS HC-3 310 CD FISHER CONT.
063 YES CD76-20 SA 40 P6 CS.IIS H
(
IP41mTCV060 CitTRL Ril & ROSVS HC-4 310 CD FISHER CONT.
063 YES CD76-20 SA 40 P6 CS.HS H
IP41mTE 055 CNTRL Ril & RDSVS HC-3 406A CD C0t4AX 068 YES IPS-805 ItDT 40 P2 CS.HS F
,. (.
IP41mTE 060 CNTRL RH & RBSVS HC-4 406A CD CONAX 068 YES IPS-805 ffDT 60 P2 CS,HS F
1R22mSHG-101 4.16HV [ftER BUS 101 39 ED GEN ELEC CD 025 YES 300-91059 DA/ SAT 8
F CS.HS H
1R22mSHG-102 4.16HV EllER BUS 102 39 ED GEN ELEC CD 025 YES 300-91059 DA/ SAT 8
F CS.HS H
1R22mSHG-103 4.16KV Ett[R BUS 103 39 ED GEN ELEC CD 025 YES 300-91059 DA/ SAT 8
F CS HS H
I b
1R23mPNL-001 480V LOAD RESET PANEL 1 125 CD RELT*MCE 025 YES AAl-125 SA/ SAT 24 F
CS.HS B
1 1R23mPNL-002 480V LOAD RESET PANEL 2 125 CD RELIANCE 025 YES, AAl-125 SA/ SAT 24 F
CS.HS B
L 1R23mP11L-003 480V LOAD RESET PANEL 3 125 CD RELIANCE 025 YES AAl-125 SA/ SAT 24 F
CS HS B
j 1R23mSHG-111 480V EllER SHGR BUS 111 95 ED ITE 025 YES 33-40359 HDT 5
F CS,HS H
(.
1R23mSHG-112 480V EllER SHGR BUS 112 95 ED ITE 025 YES 33-48359 ftBT 5
F CS.HS H
j IR23mSilG-113 480V EllER SHGR BUS 113 95 ED ITE 025 YES33-483S9 I!DT 5
F CS.IIS H
1
\\-
l 1R24mitCC1115 ff0 TOR CONT CNTR, BUS 1 115 ED SQUARE D CD 025 YES 108-1.01 L2 It0T 4
F CS.HS H
i IR24 mitCC1116 IIOTOR CONT CNTR. BUS 1 115 ED SQUARE D CD 025 YES 108-1.01 L2 I!BT 4
F CS,HS H
\\/
_1R24mitCC1125 IlOTOR C0!IT CitTR. BUS 1 115 ED SQUARE D CD 025 YES 100-1.01 L2 HDT 4
F CS.HS H
}
l V
CS = COLD SituT DOHtt P : PIPE 110UNTED SBT=STilGLE FREQUENCY QUALIFICATION IIILEST0ftES REVISIOff 11 - JUHE 1983 DA =DYllA!!!C AtlALYSIS
- TEST ARTICLE BIAXIAL TESTIllG A =REEVALUATI0t1 C011PLE1E F = FLOOR lt0Utt1ED B = REQUEST FOR QUAL OR BID ISSUED tiO1 E t HUlt0FR III j
lts = HOT STAf4DBY QP = QUALIFIED BY N =t1EITHER CS OR 115 C :S/H REC 0ftflEllDATI0tl TO LILCO
' TYPE flit 4G' COLUttfl IS (e
itDT=f tULTI-FREQUEtiCY PIPING AfiALYSIS D =CUAL DOC RECEIVED QUAT 4TITY OF ITEttS.
(
BIAXIAL TESTIrlG SA = STATIC At4ALYSIS E =ttARDilARE tt00IFICATION REQ'D SitST=ttulTI-FREQUEllCY SAT = sit 4GLE FREQUEttCY F = QUAL DOC APVD & FILED SIrlGLE AXIAL TESTING SIllGLE AXIAL TESTItjG G =SQRT PAPER C0!!PLETC
. %/
H = COPIES OF DOC TO DISTRIBUTION s
i
gs
\\
f
\\
k SHOREHAlli.
1 C2 LIST STorlE & HEDSTE3 Et4GIttEERI CORPORATI0tt RUtt DATE 06/22/;3 J0!2 HUtfDES 11600 1-SORT C0t4 TROL BUILDItlG CATEGORY I EQUIPitElli RUtt lIllE 09.50.19 s
LILCO DOCHET 50-322 ACTIVE DOP QUALIFICATI0ft LEVEL 1218 ITEllS)
PAGE 6 ItARH EQUIPilENT SPEC DIV.
E'LDG AVAIL CUAL QUAL TYPE SAFE QUAL ttuttDER DESCRIPTION NO.
RESP VENDOR ELEV INSP REPT llETil FREQ liiffG SitTDH STATUS IR24mitCC1126 It0 TOR CottT CitTR. BUS 1 115 ED SQUARE D CD 025 YES 108-1.01 L2 ftDT 4
F CS ells H
1:24mitCC1133 It0 TOR C0t4T CNTR. DUS 1 115
[D SQUARE D CO 025 YES 108-1.01 L2 ftDT 4
F CS.Ils H
1R24mitCC1134 IIOTOR CollT CNTR. DUS 1 115 ED SQUARE D CO 025 YES 100-1.01 L2 110T 4
F CS.113 li 1R35mPIL-01 EllER 120V Pit B1-REL R 124 ED SYSTEll C0tli 044 YES 15074 SAT 21 F
C3.HS H
IR35mPtL-03 EllER 120/240V PAttEL 124 ED SYSTEll COrlT 020 YES 15074 SAT 21 F
CS.IIS H
IC35mPit-R1 EltER 120V PtL RI-REL R 124 ED SYSTEll C0t4T 044 YES 15074 SAT 21 F
C3.IIS H
(
1R35mPtL-R3 EllER 120/240V PANEL 124 ED SYSTEll CONT 020 YES 15074 SAT 21 F
CS.HS H
1R35mPit-01 EltER 120V PtL 01-REL R 124 ED SYSTEll CONT 044 YES 15074 SAT 21 F
CS.HS II
(
1R35ePfL-02 EttER 120/240V PANEL 124 ED SYSTEli Cotti 000 YES 15074 SAT 21 F
CS.HS 11 1R35mT-B1 XfitR-El!ER 120V PTL B1 248 ED flAGt4ETICS 025 YES 43424-1 10T 9
F CS ells 11 1R35mT-03 XttFR-EttER 120V PitL 03 248 ED ltAGt1ETICS 025 YES 43424-1 ft3T 9
F C3.IIS H
1R35mT-R1 XFitR-EllER 120V Pitt R1 248 ED
!!Act4ETICS 025 YES 43424-1 ftST 9
F CS.143 Il 1R35mT-R3 XIIFR-EttER 120V PIL R3 248 ED flAGtIETICS 025 YES 43424-1 ItDT 9
F CS.lls II 1R35mT-01 XFi!R-EttER 120V PIL 01 248 ED ltAGNETICS 025 YES 43424-1 ItDT 9
F CS.11S H
b 1R35mT-02 Xf tFR-EttER 120V PFL 02 248 ED llAGNETICS 025 YES 43424-1 ItDT 9
F C5.IIS H
1R35mT-201 XFR-liTR SPACE HTR-BUS 248 ED l!AGitETICS 025 YES 43424-1 ftDT 9
F CS.HS H
Y 1R35mT-202 XFR-ItTR SPACE HTR-BUS 248 ED llAGitETICS O25 YES 43424-1 ItST 9
F CS.IIS 11 1R35mT-203 XFR-IITR SPACE HTR-DUS 248 ED ltAGitETICS 025 YES 43424-1 l!DT 9
F CS.HS ll L.
1:41mE/5050 P0HER SUPPLY 421 CD BAILEY-ItETER 063 YES QR-3201-7000PS ItDT 38+
F4 CS H
1R42*DA-Al 125 VOLT BATTERY 116 ED GOULD IHC 025 YES 42795 I!DT 40+
F CS.HS H
(.
_ 1R42*DA-D1 125 VOLT BATTERY 116 ED COULD IHC 025 YES 42795 ftDT 40+
F CS.IIS H
V CS = COLD SitUT Dolitt P : PIPE IlourtTED SDT= SINGLE FREQUEttCY QUALIFICATI0tlllILESTONES REVISIO!! 11 - JUtlE 1903 OA :DYllAllIC ANALYSIS e TFST ARTICLE BIAXIAL TEST 1ttG A =REEVALUATICfl C0tlPLE1E F = FLOOR lt0UtiTED B = REQUEST FOR QUAL OR DID ISSUED tt0TE: IlUttDER Ill llS =ttOT STAttDQY QP = QUALIFIED Bf H =HEITHER CS DR HS C =S/H REC 0!!!!EtiDATIOtt TD LILCO
' TYPE IITilG' COLUttti IS v
IUT:!!ULTI-FREQUEttCY PIPIttG AllALYSIS D = QUAL DOC RrCEIVED QUAllTITY OF ITElls.
g BIAXIAL TESTIIIG SA = STATIC AftALYSIS E =llARDilAPE ItCDIFICATIOil REQ'D SitST:ltULTI-FREQUtilCY SAT:S!!iGLE FREQUEHCY F = QUAL DOC APVD & FILED SitiGLE AXI AL TESTING sit 1GLE AXIAL TESTINC, G =SQRT PAPER CottPLETE V
ll = COPIES OF DOC TO DISTRIDUTI0tl y
I n
j SHOREHAll L( 1 C3 LIST STONE & HEZSTER ENGINEETIUCORPORATIDH RUti DATE 06/22/83 JOB Nut 2E2 11600 1-SCRT Cottt:0L DUILDIttG CATEGORY I.EQUIPitEllT RUti TillE 09.50.19
(
LILCD DOCHET 50-322 ACTIVE DOP QUALIFICATI0tl LEVEL 8218 ITLilS)
PAGE 7 HARK EQUIPffENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL NUtIDER DESCRIPTI0tt NO.
RESP VENDOR ELEV IriSP REPT llETH FREQ liff4G SitTDtt STATUS 1%*2aBA-C1 125 VOLT BATTERY 116 ED GOULD IllC 025 YES 42795 HBT 40+
F CS.HS H
10t2mBC-Al 125 VOLT BATTERY CHARGE 118 ED SOLIDSTATE 025 YES 3/29/76 SAT a
F CS.HS H
1Rt2eBC-B1 125 VOLT BATTERY CHARGE 118 ED SOLIDSTATE 025 YES 3/29/76 SAT 8
F CS.HS H
1R42mDC-C1 125 VOLT BATTERY CilARGE 118 ED SOLIDSTATE 025 YES 3/29/76 SAT 8
F CS.HS H
12%2mPIL-Al 125 VDC DIST PAtlEL BUS 124 LD SYSTEH CollT 025 YES 15074 SAT 21 F
CS.HS H
IM2ePtL-A2 125 VDC DIST PAtiEL BUS 124 ED SYSTEH CONT 044 YES 15074 SAT 21 F
CS.HS H
1R12nPfL-B1 125 VDC DIST PAttEL BUS 124 ED SYSTEll C0ffT 025 YES 15074 SAT 21 F
CS.HS H
10'2mPit-82 125 VDC DIST PANEL BUS 124 ED SYSTEli CONT 044 YES 15074m SAF 21 F
CS.HS H
1R52 spit-C1 125 VOC DIST PANEL BUS 124 ED SYSTEll CONT 025 YES 15074 SAT 21 F
CS.HS H
IR42mPflL-C4 125 VDC DST PFL-BLM-BS 124 ED SYSTEll COliT 025 YES 15074 SAT 21 F
CS.HS H
(
IR42mSHG-Al 125 VDC SHG BATTERY BU 95 ED ITE 025 YES 33-51264 itDT 5
F CS.HS H
1R12mSHG-01 125 VDC SHG BATTERY BU 95 ED ITE 025 YES 33-51266 ItDT 5
F CS.IIS H
1R42msll3-C1 125 VDC SHG BATTERY BU 95 ED Ild 025 YES 33-51266 t!BT S
F C5.HS H
1R43mG-101 EllER DIESEL GEliERATOR 89 ED DE LAVAL 025 YES 11001 DA 4
FIS CS.HS H
O 1R43mG-102 EllER DIESEL GETTER 4TI'R 89 ED DE LAVAL 025 YES 11001 SAT 4
F18 CS.HS H
1 1Rt.3 m G-103 EllER DIESEL GEllERATOR 89 ED DE LAVAL 025 YES 11001 SAT 4
FIS CS.HS H
- 7 IR43mLS 004 FUEL OIL AUX DAY TH 407 CD IMG11ETROL 022 YES 43235-1 SAT 17 F3 14 H
1R43mLS 007 FUEL DIL AUX DAY TN 407 CD tlACliETROL 022 YES 43235-1 SAT 17 F3 H
H
(<
i 1R43mTH-135 FUEL DIL DAY 114 PD BUFFALO TAHH 044 YES H!!(BB-134-IA SA 27 F3 CS H
1R81mT-012 IIT TRACING TRANSFilR 248 ED HAGtIdTICS 025 YES 43424-1 ifBT 9
F2 CS llS H
L
_ 1Tt8eP!L-ACH PC ATil CNTRL 1F5 CD RELIAtICE 053 YES 99AX400600 SA/ SAT 19 F
H B
(.
CS = COLD SituT Dolitt P = PIPE INNTED SBTzSIl4GLE FREOUENCY QUALIFICATION HILEST0t4ES REVISICH 11 - JUNE 1983 DA =DYIIAllIC ANAi.YSIS w TEST ARTICLE DIAXIAL TESTING A mREEVALUATIott C0ttPLETE F = FLOOR l!OUtHED B : REQUEST FOR QUAL OR DID ISSUED fl0TE: teut! DER IN HS :llOT STANDBY QP z QUALIFIED BY H
llEITHER CS OR HS C =S/ll REC 0!!!!Ett0ATIO!4 TO LILCO
' TYPE IITilG' COLUttN IS
(,
lloT-IfULTI-FREUUEllCY PIPIrlG AttALYSIS D LOUAL OCC RECEIVED QUATITITY OF ITEllS.
j CIAXIAL TESTIllG SA = STATIC AtlALYSIS E =lW7DllARE It0DIFICATIO!4 I?EQ'D l
-ttSi st fULTI-FRFQUEf fCY
, SATrSit.SLE FREQUEllCY F = QUAL DOC APVU 1 FILED S!!IGLE AXIAL TESTING -
SIllSLE AXIAL TESTING, G 3QRT PAPER CottPLETE v
H : COPIES OF DOC TO DISTRIBUTION s
~
2 O
O O
o SHOREHAll UNIT 1 C3 LIST STot4E A HEDSTE2 Eld 1teFEwit:0 CORPORATIDH RUll D'.TE 06/22/83 JOB taullDER 11600 1-SORT CotaTROL BUILDItiG CATECORY I EQUIPitElli RUtt TIllE 09.50.19 4
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL (218 ITEttS)
PAGE 8 ftARH EQUIPflENT SPEC DIV.
CLDG AVAIL QUAL QUAL TYPE SAFE QUAL HUiOER DESCRIPTION tio. RESP VEtiDOR ELEV ItiSP REPT ltETH FREQ llTilG S!!TDit STATUS 1148mPtL-A2 HYD RECollDINER C0tif CA 209 PD ATOlICS IllT 063 YES 54591-4 ftDT 4
F2 ft H
IT48ePH-25 llYDRO REcollB C0 tit CABI 344 ED DELPill ITU 063 YES 1035-5 SA/ SAT 29 F2 ft H
a If48 RH-26 HYDRO REC 0t!B C0hT CABI 344 ED 2ELPHI IIM 063 YES 1035-5 SA/ SAT 29 F2 tl H
1X41mACU-14 C0tP. RELAY 8 Ell SHGR Ril 240 PO BEHilS0tt CO Or44 YES A-47-75-01 SA 39 F2 CS.HS H
k
.1X41eOllPF FIRE DAtlPERS 54 PD AIR RALAriCE 044 YES ADI-SH-009 SAT 9+
F30 CS.HS H
IX41aFrt-029 RELAY 1EttER SHCR RET Fil 270 PO BUFFALO FORGE 053 YES 74S-11139 SA to F2 C3.Its H
.(
IX41mFN-039-CR CHILL EQUIP RH EXH 270 PD DUFFALO FORGE 067 YES 745-12140A SA 57 F2 CS h3 If IX41mFN-072 BATTERY Rig VENTILATION 270 PD DUFFALO PORGE 035 YES 745-11140C SA 105 F3 CS.HS H
IX41eFS 013 ACU-14 AIR FLON 319 ED P0ltERS REG 031 Y E".
43812-1 IDT 24 F2 CS.IIS H
IXilmFS 017 FN-29 AIR FLOli 319 ED pollers REG 044 YES 43812-1 IBT 24 F2 CS.itS H
IX'llettE 021 ACU-14 C00LIteG Cl;TRL 319 ED P0HERS REG 044 YES 43812-1 ItDT 24 FZ CS.itS H
1X41ellIT021 ACU-19 COOLING CitTRL 319 ED pollers REG 049 YES 43812-1 fBT 24 F2 CS.HS H
('
1X41mit00031 FN-039 CUTDOOR AIR 319 ED PCHERS REG 063 YES 43012-1 ICT 24 F2 CS.IIS H
1X41stt00032 Fil-039 EXHAUST AIR 319 ED pollers REG 064 YES 44540-1 IET 27 F2 CS.HS H
, y 1X41ettoD035 ACU-14A DISCHARGE AIR 319 ED P0HERS REG 044 YES 43812-1 ItBT 24 F2 CS ells H
IX41el100036 Ort FAtt Fit-29At B 319 ED pollers REG 044 YES 43812-1
!!DT 24 F2 CS.HS 11 G
1X41stt00039 Fil-72 OUTDOOR AIR 319 ED P0HERS REG 037 YES 44057-1 IBT 21 F3 CS.HS X
1X4Iol10D040 Fil-72 EXHAUST AIR 319 ED P0HERS REG C41 YES 44057-1 IST 21 F3 CS.HS H
L.
1X41 alt 00041 Fit-72 RETURN AIR 319 ED pollers REG 035 YES 44057-1 ItDT 21 F3 CSellS H
IX41stt00059 RELAY & CIPTR Ril T[tr 319 HD pollers REG 044 YES 44057-1 ftDT 21 F2 CS.HS H
L.
_ 1X41ePflLVC16 VEtlT C0rlTROL PAriEL 319 ED POWERS REG 025 YES 1001-6 SA/ SAT 24 F
tt H
(,,
CS = COLD SHtti 00ltri P = PIPE It0UtiTED SBT=SIrlGLE FREQUEHCY CUALIFICATI0tl llILEST0 ties REVISION 11 - JttIE 1983 DA =DYllAtlIC AtlALYSIS e TEST ARTICLE BIAXIAL TESTittG A =REEVALUATI0tt C0ttPLETE F =FLOCR 1100! LIED S = REQUEST FOR QUAL OR BID ISSUED tio rE flutt0ER Ita 115 =tt0T STATIDDY QP = QUALIFIED BY ll =tiEITHER CS OR ltS C =S/H REColutEttDATI0tl TO LILCO
' TYPE ffTil3' COLUttN IS
(,,
itBT=ttULTI-F R ECUEtICY PIPI!iG AtlALYSIS D =CUAL DOC RECEIVED QUAT 4TITY OF ITEttS.
DIAXIt.L TESTIt4G SA = STATIC A14ALYSIS E =lt/RDilARE It0DIFICATION REQ'O SitST:ltULTI-FREQUEtiCY SAT =SitiGLE FREQUErlCY F =0UAL DOC APVD & FILED Sir 4GLE AXIAL TESTIt4G SIllGLE AXIAL TESTIt4G G =SQRT PAPER C0f!PLETE 1
4r.
H =CDPIES OF DOC TO DISTRIBUTION
}
t SHOREHAtl b 1T 1 CB LIST STONE & HEBSTED ENGINEt w J CORPORATION RUN DATE 06/22/83
%s JOS tlUtCE2 11600 1-SORT CorlTROL DUILDING CATEGORY I EQUIPitEllT RUN TIttE 09.50.19
(
LILCO DOCHET S0-322 ACTIVE BOP QUALIFICATI0tl LEVEL (210 ITEllS)
PAGE 9 HARH EQUIPHENT SPEC DIV.
ELDG AVAIL QUAL QUAL
- TYPE SAFE QUAL HuttDER DESCRIPTIDH F80.
RESP VENDOR ELEV IHSP REPT llETH FREQ itTriG SHTON STATUS
(
1X41mPilLVC17 VENT CONTROL PANEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F
N II 1X41mPtLVC18 VENT Cot 4 TROL PANEL 319 ED P0HERS REG 02S YES 1001-6 SA/ SAT 24 F
H H
L 1X41mPtLVC19 VENT COHTROL PANEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F
CS.HS H
1X41mPNLVC20 VENT CONTROL PANEL 319 ED P0llERS REG 025 YES 1001-6 SA/ SAT 24 F
CS.flS H
1X41mPHLVC21 VENT CONTROL PAHEL 319 ED pollers REG.
044 YES 1001-6 SA/ SAT 24 F
CS.HS H
t""
_1 IX41mTCV021 ACU-19 COOLING COIL 310 CD FISHER CONT.
053 YES ' 2-24451 SA 25 P2
'CS H
d?_'
T
?
(
P0HERS REG
'030 YES 4301bli it3T 24 F3 CS.fl3 H
IX41mTE 018 FN-72 OAIPER C0tlTROL 319 ED s
1X41mTE 021 ACU-14 COOLIt4G CONT 406 CD ROSEtt0UrlT 044 YES -2767 SAT 35+
F2 CS.HS~ fl g
L
~- Fil-39 C0tlTROL 319 ED P0HERS REG 068 YES 43812-1 1X41mTIS031
-IX41mTT-001 Ril TEtr INO 319 ED P0HERS REG 0"5 YES '.43812-1 ItDT 24 FZ H
H
,/
,1X'ilmTT-002 Rtt TEttP It:0 319 ED.F0HERS REG 025
' Y"E S 43812-1 ICT 24 F2 N
H c
s r
- 1X41mTT-003 Rtt TEttP IND 319 ED P0HERS REG 025 YES 43812-1 / '
' It0T 24 F2 N
H
%./
1X41mTT-004 Ril TEtIP IIID 319 ED P0HERS REG-044 YES 43612-1 I!DT
< 24 F2 N
H 1X41mTT-005 Ril TEttP Ito,.
319, ED P0HERS REG 044 YES 43812-1 ffDT 24 F2 11 H
i Q)
CHILLElf EQUIP kH TEt"*
319 ED P0HERS REG 068 TES 43812-1 if3T 24 F2 H
H 1X41mTT-006
/g
. 1X41mTT-007 BAT Rlt TEttP 119 ED P0HERS REG G37 YES 43012-1 f tBT' 24 F2 N
H
~
V~ '1X41aTT-009 C010 UTER Ril TEttP d-ED P0llERS REG 044 YES 43012-1 ItDT 24 F2 H
H
^
FD BUFFALO FORGE 040' YES 74S-11136 SA 20 F3 CS.HS H
.1X60mFN-028 DIESEL GEN Rtt SUPPL o
g i
v YES 44057-1
!!DT 21 F3 CS H
IX60 nit 00031-FH-28 OUTDOOR AIA U9 8.D P0HERS REG 033s
/
IX60ml100032 FN-39 It0T DA!!PER 319 ED POHERS REG 030 YES 44057-1 ItST 21 F3 CS H
(.
_ 1X60att00033 FN-2G RETURH AIR 319 ED pollers REG 038 YES 44057-1 ItDT 21 F3 CS 11 i
- [l CS = COLD SHUT 0011H P = PIPE tt0UNTED SGT= SINGLE FREQUENCY QUALIFICATICifitILESTONES REVISI0tt 31 - JUttE 1983 s.
DA :DYtfAftIC AtlALYSTS
- TEST ARTICLE BIAXIAL TESTIrlG A = REEVALUATION C0t1PLE1E s
D = REQUEST FOR QUAL OR DID ISSUED fGTE: tlUt2E'2 Ill
-F-
= FLOOR tt0Ut4TED 115 =ll0T STAtIDBY GP = QUALIFIED BY H =NEITHER CS OR HS C =S/ll RECattitEt40AT10tl TU LILEO
' TYPE It1HG' COLuttH IS
(,
HDT=l!ULTI-FREQUC.4Y PIPItiG AFIALYSIS 0 = QUAL OCC RECEIVED (MMIITT OF ITEttS.
DIAXIAL TESTit4G SA = STATIC AtlALYSIS E =llAR0llARE It0DIFICATIO!4 REQ'D
+
-!!ST=ttOLTI-FREQUEtlCY SAT =SIliGLE FREQUEliCY F =GUAL DOC APVD L FILED '
SIllGLE AXI AL TESTIt4G SIttGLE AXIAL TESTIflG G =SQRT P/PER ColfPLETE
.fl = COPIES OF DOC TO DISTRIBUTION v
d
.b
- SHOREHLw.IT 1 CB LIST SToriE & HEBSTER EtlGINE M.4G CORPORATION RUN DATE 06/22/23 9
s JOS HuttnER 11600 1-50RT CONTROL DUILDIttG CATEGORY I EQUIPitENT RUti T!IfE 09.50.19 f
4 I
LILCO DOCHET 50-322 ACTIVE CDP QUALIFICATI0tl LEVEL (218 ITEttS)
PAGE 10 HARN EQUIPitENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL t1U110ER DESCRIPTION NO.
RESP VENDOR.
ELEV INSP REPT ttETH FREQ ttTilG SilTDN STATUS IX60mPit.VC13 VEllT C0t4TRO'. pat 4EL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F
CS.HS H
-IX60mPNLVC14 VENT CON'IROL PANEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F
CSelfS H
+.
1X60mPHLVC15 VENT C0tiTROL PANEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F
CS.HS H
1X61mACU-07 C0tlTROL RO0tt A/C UNITS 240 PD DAHrtSON CO 063 YES A-47-75-01 SA 39 F2 CS.HS H
t IX61mA00037 CNTRL Ril ISOL 319 ED P0HERS REG 063 YES 44540-1 ftBT 27 F3 CS.HS H
4 IX61mA0V036 CHTRL Rit ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 17+
P2 CS H
k IX61mA0V038 CitTRL RH ISOL 111 PD FISi1ER 073 YES C075-35 SA/ SAT 21 P2 CS H
IX61mA0V039 CHTRL Rif ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 21 P2 CS H
k IX61mDitPF FIRE DAIIPERS 54 PD AIR DALANCE 063 YES AB1-SH-009 SAT 9+
F8 CS.Ils il IX61mFLT-02 CRAC FILTER TRAINS 105 PD FARR CD 063 YES D-56302 SA/ SAT 17 F2 CS.HS H
\\
IX61mFit-025 CortTROL R00tl BOOSTER F 102 PD BUFFALO FORGE 063 YES 745-4234A SA 27 F2 CS tts H
IX61mFS 011 Fit-25 CNTRL 319 ED P0llERS REG 063 YES 43812-1 IIDT 24 F2 CS.HS H
~
U IX61mFS 012 ACU-7 AIR FLOH 319 ED P011ERS REG 063 YES 43812-1 HBT 24 F3 CS ltS H
IX61aHS 038 IX61mA0V038 CollTROL 319 ED P0HERS REG 066 YES 43812-1 IIDT 24 F2 CS.HS H
{
IX61sttE-021
.ACU-7 CtlTRL 319 ED P0HERS REG 063 YES 43812-1 ItST 2'4 F2 CS.HS H
4 IX61stt00033 FN-25 DISCH AIR 319 ED P0HERS REG 063 YES 44540-1 HBT 27 F2 H
H
(.
IX61mit0D034 ACU-7 DISCHARGE AIR 319 ED P0HERS REG 063 YES 43812-1 IIDT 24 F2 CS.IIS H
1 IX61mit0V031 CNTRL Rtt ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 22+
P2 CS H
1.
IX61a!!OV032 Ct4TRL Ril ISOL 111 PD FISHER 063 YES C075-35 SA/ SAT 22+
P2 CS H
1X61mTCV021 ACU-7A C00LIr4G UNIT 310 CD FISHER CONT.
I
\\.
i
_ 1X61mTE 021 ACU COOLING COHT 406 CD ROSEtt0UHT 067 YES 2767 SAT 35+
F2 CS.HS H
I 3
l 1
y CS = COLD SilUT D0liff P = PIPE tt0UNTED SBT=SINSLE FREQUENCY QUALIFICATION HILESTONES REVISION 11 - JUI4E 1983 1
DA =DYllAllIC AtlAl.YSIS
- TEST ARTICLE BIAXIAL TESTIt;G A = REEVALUATION CollPLETE F = FLOOR 110Ut4TED B = REQUEST FOR QUAL OR DID ISSUED fl0TE: NuttBER Iti j
HS =110T STAtIDDY QP = QUALIFIED BY H =flEITHER CS OR HS C =S/H REColl!!EllDATI0tt TO LILCO
' TYPE ttTriG' COLUI1N IS O
It0T=t tutti-F REQUEllCY PIPIttG AtlALYSIS D = QUAL DOC RECEIVED QUAtiTITY OF ITEllS.
j DIAXIAL TESTItlG SA = STATIC AtlALYSIS E =HARDilARE lt001FICATION REQ'D
-itST:11ULTI-FREquEllCY SAT =SIHCLE FREQUEllCY F = QUAL. DOC APVD & FILED SIriCLE AXIAL TESTIrlG SillGLE AXIAL TESTIf4G G =SQRT PAPER C0t!PLETE y
H = COPIES OF DOC 10 DIT UIDUTION i
n i
A/-
SHOREllAt m di 1 C3 LIST STot4E & HEBSTER EllGINELJ CORPORATIDH WUN DATE 06/22/83 N
JC3 HuttDER 11600 1-50'tT CCt4 TROL EUILDING CATEGORY I EQUIPitEttT RLII TillE 09.50.19 s
LILCO DOCHET 50-322 ACTIVE BGP QUALIFICATI0t1 LEVEL (21811 Ells)
PACE 11 l!ARN EQUIPitENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL FIUt!BER DESCRIPTION 140. RESP VEffDOR ELEV If4SP REPT tlETH FREQ HTNG SHTON STATUS 1Z93mTIIU50 TRIP /CALIB UNIT 406 CD ROSEll0UNT 063 YES 127531 SAT 57+
F4 CS H
1Z95 met 4CSX1 SXS EtlCLOSURE 125 CD RELIAtlCE O r,4 99AX400027 SA 61 F
B t
1Z95eEllCSX2 SXS EtlCLOSURE 125 CD RELIAtlCE 044 99AXt400827 SA 61 F
B i
IZ95aEttCSX3 SXS EllCLOSURE 125 CD RELIAtlCE 044 99AXrl00827 SA 61 F
B IZ95aEliCSX4 SXS EttCLOSURE 125 CD RELIAtlCE 044 99AXt400827 SA 61 F
B IZ97mPflLER1 ItULTIPLEX CAB 125 CD R[LIAtlCE 0'44 99AX401437 SA 14 F
B IZ97mPflLER2 IlULTIPLEX CAB 125 CD RELIAlfCE 044 99 AXt401437 SA 14 F
B 1Z97mPit.ER3 ItULTIPLEX CAD 125 CD RELIANCEV 044 99AXt:01437 SA 14 F
B s
k.
1
)
(
(
i l
\\
i
('
r I
4
(.
CS = COLD SHUT D0liti P = PIPE It0UtiTED SBT= SINGLE FREQUEtiCY OUALIFICATION llILESTONES REVISIOrt 11 - JUNE 1983 DA DYllAttIC AftALYSIS w TEST ARTICLE DIAXIAL TESTItiG A =REEVALUATIOtt CottPLETE F =FLOCR tt0UrtIED B = REQUEST FOR QUAL OR BID ISSUED fiOIE: ilUttBER Iti HS = HOT STAliDBY OP = QUALIFIED BY ll =HEITHER CS OR HS C =S/ll REC 0tittEtIDATI0tl TO LILCO
' TYPE 11TilG' COLUtlfl IS i
I ItuT-ItUlTI-TREQUEt40Y PIPIll0 AtlALYSIS D =0UAL 00C RECEIVED QUA!4TITY OF ITEllS.
(,
DIAXIAL TES111tG SA = STATIC AtlALYSIS E =HARDilARE !!ODIFICATION REQ'D
-f tST=ttULTI-FREQUEHCY SAT =SIttCLE FREQUtttCY F = QUAL DOC APVD & FILED 4
SittGLE AXIAL TESTIt4G SIllGLE AXIAL TESTIllG G =SQRT PAPER C0ffPLETE y
11 = COPIES OF DOC TO DISTRIDUTIOrt i
i
,m yg
(
')
( )
SHOREHAM L s'1 H LIST STottE & HE! STER ENGINEERI PORATION RUN DATE 06/22/83 b
JOB NUlBEJ 11100 1-SORT HISCELLANEOUS CATEGORY I EQUIPtfENT Rtri TIHE 09.50.15 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0H LEVEL ( 20 ITEttS)
PAGE 2 ftARM EQUIPMENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL NUtIBER DESCRIPTION HO.
RESP VEtOOR ELEV INSP REPT HETH FREQ MTNG SHTDH STATUS 1X41mTT008 SCRtL PUFFHSE TEN' 319 CD P0HERS SH025 YES 43812-1 HBT 24 F2 H
H e~.
.m m
n e
o' CS = COLD SHUT DOHN P = PIPE HOUtiTED SBT= SINGLE FREQUENCY QUALIFICATIOtt HILESTONES REVISIDH 11 - JUNE 1983
_DA =0VNAttIC ANALYSIS PC =PRIllARY CotiT.
BIAXIAL TESTING A = REEVALUATION CD::PLETE F = FLOOR ifoU:4TED PL = PEDESTAL SC =SEC0f0ARY CONT.
B = REQUEST FOR QUAL OR BID ISSUED NOTE: PAJttDER IN HS = HOT STATCDY QP = QUALIFIED BY C =S/H RECOtttEtlDATION TO LILCO
' TYPE ffTNG' COLUtN IS p
S 93T=HULTI-FREQUENCY PIPING ArtALYSIS
- = LOCATED OH CONT.
D =CUAL DOC RECEIVED QUAtiTITY OF ITEMS.
BIAXIAL TESTIrlG SA = STATIC AtlALYSIS HALL E =HARDHARE HODIFICATION REQ'O HST=t1ULTI-FEFQUEtlCY SAT = sit!GLE FREQUENCY N =NEITHER CS OR HS F =CUAL DOC APVD & FILED SINGLE AXIAL TESTING SIllGLE AXIAL TESTING G =SQRT PAPER C0tIPLETE p
r H = COPIES OF DOC TO DISTRIBUTION I
O r
O O
1
W M
RUN DATE 06/22/;3 g
/
SHOREHAH tJH H LIST STONE & HE"STE3 ENGINEERI ORATION RUN tit:1 09.50.15 V
HISCELLAtlE005 CATEGORY I EQUIPitENT b
JOB ttUNDE2 11600 1-50RT PAGE 1
%d' LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL t to ITEMS)
HARM EQUIPHENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL NUHBER DESCRIPTION NO.
RESP VENDOR ELEV IttSP REPT HETH FREQ HTNG SHTDN STATUS v
1C61mPT-011 SVC HTR HDR PRESS 406 CD ROSDIOUNT SH YES 127516 teT 60+
F CS.HS F
d j
IP41rHOV031 SERV HATER DIS 197 PD PRATT SH020 YES D-0034-1 SA/ SAT 33+
P4 CS.HS H
l 1P41mH0V032 SERV HATER HDR IV 197 PD PRATT SH033 YES D-0034-6 SA/ SAT 13+
P2 CS,HS H
J IP41mHOV035 T BELOH SUPLY IV 197 PD PRATT SH025 YES D-0034-4 SA/ SAT 33+
P2 N
H IP41mP-003 SERVICE HATER PUN'S 057 PD bit 4GHAH-HILL SH021 YES HE-816 SA 28 F4 CS.HS H
J IP41mPDT150 SERV HTR DIFF 406 CD ROSDtOUNT SH YES 127516 HBT F4 CS.HS F
IP41mPtt-FX1 FD AUX RELAY CABINET 125 CD RELIANCE SH023 YES 99AX400708 SA/ SAT 33+
F CS.HS H
')
IP41mS-001 SERVICE HATER STRAINER 081 PD RP ADAHS C0 SH026 YES N07503 DA 17 F4 CS.HS H
1324mHCC1110 480 V HOTOR CONT CENTE 115 ED SQUARE D CO SH021 YES 108-1.01L2 IBT 4
F CS.HS H
.~- o i
1":20mHCC1120 480 V HOTOR CONT CENTE 115 ED SQUARE D CO SH021 YES 108-1.01L2 IBT 4
F CS.HS H
1 I
17.3mP-201 FUEL OIL XFER PU 420 PD CRANE CO VD020 YES HE572 SA 13 F3 CS H
l )
1Rt3mP-202 FUEL OIL XFER PU 420 PD CRAliE CO YD020 YES HE572 SA 13 F3 CS H
1R;3 MRV 025 P-202 DISCH 191 CD LOffERGAN PH024 YES 502644 SA 60 P3 CS H
, U l
1R;3 MRV 026 P-201 DISCH 191 CD LONERGAN PH024 YES 502644 SA 60 P3 CS H
1Ri3mTH-132 FUEL OIL STORAGE 114 PD BUFFALO TAtM YD020 YES NHtBI-22 SA 14 F3 CS H
J IX;1mFN-068 SCRttiELL PUtFHSE SUP 270 PD BUFFALO FORGE SH034 YES 745-11140 SA 26+
FZ CS.HS H
IXtimH00042 FN-68 OUTDOOR AIR 319 CD P0HERS SH025 YES 44057-1 HBT 21 F2 CS.HS H
IX41mH00043 FN-68 EXHAUST AIR 319 CD P0HERS SH025 YES 44057-1 MIT 21 F2 CS HS H
IX41mH00044 FN-68 RETURN AIR 319 CD P0HERS SH025 YES 44057-1 HBT 21 F2 CS.HS H
V V CS = COLD SHUT DOHN P : PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATI0H HILESTONES REVISION 11 - JUNE 1983 PC =PRIltARY CONT.
BIAXIAL TESTINS A = REEVALUATION C0tPLETE
_DA =DYtlAHIC ANALYSIS SC = SECONDARY CONT.
B = REQUEST FOR QUAL OR BID ISSUED HOTEt HUtSER IN F = FLOOR HOUNTED PL = PEDESTAL C =S/H REC 0tt:1Et1DATION TO LILCO
' TYPE HTNG' COLtkN IS HS = HOT STAFCBY QP = QUALIFIED BY V FOT=HULTI-FREQUENCY PIPING ANALYSIS e = LOCATED ON CONT.
D = QUAL DOC RECEIVED QUANTITY OF ITENS.
BIAXIAL TESTING SA = STATIC ANALYSIS HALL E =HARDHARE HODIFICATION REQ'D HST=HULTI-FREQUUICY SAT = SINGLE FREQUENCY N =NEITHER CS OR HS F = QUAL DOC APVD & FILED G =SQRT PAPER COMPLETE SINGLE AXIAL TESTING SINGLE AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTION s
.)
7
m
(
0 N.
SHOREHAH UNIT 1 W3 LIST STollE 1 HEDSTED Et4GINEERING CORPORATION RUN DATE 04/22/83 JOB I4UlfBER 11400 1-SORT REACTOR DUILDING CATEGORY I FLOOR-It0UllTED EQUIPitENT PUtl tit 1E 09.49.54 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL 1151 ITEllSt PAGE 1 IIARM EQUIPilENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL PAJIIDER DESCRIPTION NO.
RESP VEICOR ELEV INSP REPT ttETH FREQ IITNG SitTDN STATUS s
IB21mLIT007 PRESS TRAffsitITTER 406 CD RChit00NT SC079 108025 HBT F2 F
1821mPt45081 LIHIT SHITCH 159 CD NAttCO PC082 QTR112 SAT P12 F
1821mPNS002 LIllIT SHITCH 159 CD HAllCO SC082 QTR112 SAT P12 F
1821mPT 004 PRESS TRAtlSitITTER 406 CD ROSEtt0UNT SC079 108025 ItDT F2 F
1821mPT 153 RV092 HONITOR 406 CD ROSEll0UNT SC040 YES 127516 HDT 60+
Fil CS.HS H 1821mOEN001 IIS SRV Qt4CHRS 447 PD SARGENT PC008 YES R-S-10078000 DA 9
F11 CS.HS H 1821 MRV 093 VAC RELIEF VALVES 175 PD AHD. GRHHD PC YES TR-77-18 SAT 18 F12 H
D i
4 1821mTE 147 itST PA STEAM LH DET 406 CD ROSEtt0UNT SC078 YES 2767 SAT 60+
F2 CS.HS H b
IC61mLT 026 SUPP POOL 406 CD ROSEtt0UNT SC008 YES 127516 ItBT 60+
F CS.Its H i
1C41mPT 012 DRYHELL PRESS 406 CD ROSEft0UNT SC098 YES 127516 IfBT 60+
F CS.HS H b
d IC61mPT 104 SAFETY REL VALVE 406 CD ROSEtt0UNT SC101 YES 127516 tiBT 60+
F CS.HS H IC61mTE 021 DRYllELL TEIP 406 CD ROSElt0UNT SC150 YES 2767 SAT 60+
F CSettS H l-IC61mTE 022 SUPP POOL TEl'P 406 CD ROSEll00HT PC028 YES 17607-1 IIDT 60+
F2 CS.HS H l
1011mPit.061 Cott DH HON 332 PD HitC SC112 YES 45493-1 ftBT 12 F
N H
j b
ID21mRE 085 RAD flotiITOR 475 CD HAllAN PC074 YES 16683-1 190T 100 F2 N
F 3
1E21mP-049 LOOP LEVEL PUllPS 23S PD GOULD PUllP SC006 YES HE-320 SA 60+
F2 CS H
G IE41mP-050 LOOP LEVEL PUlr 235 PD COULD PUllP SC006 YES HE-320 SA 60+
F CS H
1E41mpT 142 TO LUDE DIL COOLER 404 CD ROSEll0UNT SC8 YES 127516 itBT 60+
F CS ells H V
1E51mP-051 LOOP LEVEL PUllP 235 PD COULD PUltP SC008 YES llE-320 SA 60+
F CS 11 1E51mPT 142 TO LUDE OIL COOLER 406 CD ROSEll0UNT Sea YF# 127516 HDT 60+
F CS.HS H
%)
J F16 RAK-22 HI DENSITY SPHT FUEL R 427 PD HACHTER SC137 YES LIL-T-151 DA 10 F29 N
H V
CS = COLD SHUT DOHN P = PIPE It0UNTED SBT=SIttGLE FREQUEtlCY QUALIFICATION HILESTONES REVISION 11 - JUNE 1983 j
D = DUCT tt00t4TED PC =PRIllARY C0tlT.
DIAXTAL TESTIttG A =REEVALUATI0tt C0!!PLETE DA =0YllAltIC ANALYSIS PL = PEDESTAL SC =SEC0t40ARY CorIT.
B = REQUEST FOR QUAL 09 BID ISSUED f10TE: t4Utt0ER Ill F zFLOOR tt0Ut4TED QP = QUALIFIED BY
/ = LOCATED ON Cot 4T.
C =S/H REC 0!!!!EtIDATIOtt TO LILCO
' TYPE IITi1G' ColuttN IS 4
y HS =tt0T STAtIDBY PIPIllG AtlALYSIS llALL D =0UAL 00C RECEIVED QUATITITY OF ITEllS.
itGT:ltVLTI-FREQUEtiCY SA = STATIC AllALYSIS H =t1EITHER CS OR HS E =HARDHARE 11001FICATI0tl REQ'D l
5 DIAXIAL TESTIt1G SAT = SINGLE FREQUENCY F rQUAL DOC APVD & FILED ItST=tlULTI-FREQUEllCY SIttGLE AXIAL TESTING G =SQRT PAPER CottPLETE v
SIttGLE AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTI0tl l
,se&'m f
C
)
I k
6 SHOREHAll
.4[ 1 R3 LIST STONE & HEBSTER EtiGIttEETIriG CORPORATI0tl RtI4 DATE 06/22/83 JOB tiUttcER 11600 1-SORT CEACTOR DUILDIllG CATEGORY I FLOOR-ItoutlTED EQUIPlfENT RUtt TIttE 09.49.51
(
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0ft LEVEL 1151 ITEllS)
PAGE 2 ftARM EQUIPitENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL I4UttDER DESCRIPTION tio.
RESP VENDOR ELEV IllSP REPT ltETH FREQ flTitG SHTDit STATUS 1F16mRAH-23 PERtl CR STOR RACHS 427 PD HACitTER SC137 YES LIL-T-151 DA 10 F
fl H
1F16 RAH-24 TEltP CR STOR RACHS 427 PD HACHTER SC137 YES LIL-T-151 DA 10 F2 il H
1G11mFT 647 SUPP POOL PUlfP BACH 406 CD ROSEttOUNT SC008 YES 127516 IIDT 60+
F3 CS.HS H 1G11=LE 642 RB FLOOR LEVEL 473 CD DELAVAL SC008 YES 45700-1 flBT 14 F
N H
IG11 ALE 645 RB FLOOD LEVEL 473 CD DELAVAL SC008 YES 45700-1 IIBT 14 F2 ti il 1Gi1*E-019 FUEL STG POOL HT EXCHA 190 PD STRUTilERS CD SC151 YES 70-06-30787 SA 25 F2 CS.HS H
\\
1G41mP-023 FUEL STORAGE POOL COOL 062G PD COULD PUttP SC151 YES IIE-325 SA 33 F2 il H
IP41mFT 146 ROCLCH llX SERV HATER 406 CD ROSElt0UtlT SC024 YES 127516 ItDT 60+
F2 CSeitS 11 b
IP41mFT 151 RAD fl0N SAttPLE 406 CD ROSEtt00 tit SC008 YES 127516 ilBT 60+
F2 CS.HS H IP12aE-011 RBCLCH HT EXCHAtlGER 190 PD STRUTHERS CO SC8 YES 70-06-30786 SA 12 F2 CS.HS 11 IP42aE-117 BOOSTER HT EXCH 190 PD STRUTHERS SC8 YES 19-06-33475 SA 5+
F2 HS H
IP42alS 012 RDCLCH TH-026 407 CD ltAGNETROL SC160 YES 43235-1 113T 17 F2 HS H
b IP42mLS 013 RDCLCH TH-024 407 CD ltAGriETROL SC160 YES 43235-1 11BT 17 F2 HS H
IP42mP-005 RS CLOSED LOOP C00LIrlG 062G PD GOULD PUttP SC151 YES llE-354 SA 68 F3 IIS H
(*
IP42aPS 021 PUttP IP42mP005C DISCll 348 ED ASCO SC153 YES 178 SAT 60+
F3 HS 11 IP%2mPS 022 PullP IP42mP0050 DISCH 348 ED ASCO SC153 YES 178 SAT 60+
F3 IIS H
IP42mPS 046 PUttP 1P42=P005A DISCH 348 ED ASCO SC151 YES 178 SAT 60+
F3 IIS H
IP42mTH-026 RDCLCH HEAD TAttH 114 PD BUFFALO TAHH SC151 YES N!HB125-IA SA 9
F2 HS 11 L
IP50mPS 105 SERV AIR HDR PRESS 348 ED ASCO SC102 178 SAT 60+
F2 CS.HS H IP50mPS 113 SERV AIR HOR NORll SUP 348 ED ASCO SC102 178 SAT 60+
F2 t.S.H S 11 V
_ 1P50=PT 111 ADS ACCUlfULATOR 406 CD ROSEtt0UtlT SC101 YES 127516 ItBT 60+
F2 CS.HS H (p
CS = COLD SHUT DOHN P = PIPE ltOUNTED SBT= SINGLE FREQUEtlCY CUALIFICATION llILEST0tlES PEVISIOtt 11 - JUtlE 1983 D : DUCT llout4TED PC =PRItlARY C0 tit.
DIAXIAL TESTIrlG A =REEVALUATI0tl CottPLETE DA =DYllAllIC AtiALYSIS PL = PEDESTAL SC =SEC0t10ARY C0!1T.
B = REQUEST FOR QUAL 09 DID ISSUED fl0TE: flulI0ER IN F = FLOOR lt0UtiTED QP = CUALIFIED BY
/ = LOCATED ON COrlT.
C =S/H REcoltitEtiDATI0tl TO LILCO
' TYPE llTt'G' COLUl!!1 IS
%p HS = HOT STANDBY PIPIllG AtIALYSIS HALL D = QUAL DOC RECEIVED QUAtiTITY OF ITCllS.
_ItBT =ltulTI-F R EQUEtiCY SA = STATIC AtlALYSIS tl =HEITHER CS OR HS E =HARDHARE It0DIFICATION REQ'D DIAXIAL TESTIt(G SAT =SItiGLE FREQUENCY F = QUAL DOC APVD & FILED
!!ST=llULTI-FREQUEliCY SINGLE AXIAL TESTING.
G =SQRT PAPER CottPLETE D
SIrlGLE AXIAL TESTIFIG H = COPIES OF 00C TO DISTRIBUTIOtt
(f U
x SHOREHAtt UNIT l' R3 LIST ST0llE & HEBSTER ENGItfEERING CORPORATI0tl RUN DATE 06/22/83
.JC3 HUHDER 11600' 1-SDRT REACTOR EUILDIIIG CATEGORY I FLOOR-IIOutlTED EQUIPitEHT RUti TittE 09.49.54
,(.
LILCD DOCHET 50-322 ACTIVE BOP QUALIFICATIOtt LEVEL 4151 ITElIS)
PAGE 3 ItARH
' EQUIPitENT '
SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL NuttDER DESCRIPTION 110. ' RESP VEtIDOR ELEV INSP REPT ltETH FREQ ltTriG SHTDtl STATUS
-1P50ePT 116 SERV AIR HDR PRESS 406 CD RDSEft00HT SC101 YES 127516 ftDT 60+
F2 CS.HS H 1:24mlEC-111H HTR CNTRL CllTR 115 ED SQUARE D CD SC150 YES 108-1.01-L2 ItDT 4
F CS.HS H 1R24mitCC-111X HOTOR C0HT CNTR. BUS 1 115 ED SQUARE D CD SC113 YES 108-1.01-L2 190T 4
F C5.HS H 1224mlEC-111Y HOTOR CONT CN1R. BUS 1 115 ED SQUARE D C0 SC78 YES.100-1.01-L2 IST 4
F CS.HS H 4
1R24mitCC-111Z IIOTOR CONT CNTR. BUS 1 115 ED SQUARE D CO SC7S YES 108-1.01-L2 llDT 4
F CS.HS H 1K2TmitCC-112H HOTOR CONT CNTR. BUS 1 115 ED SQUARE D CD SC150 YES 108-1.01-L2 IET 4
F CS.IIS H
(,,
1R24mitCC-112X HOTOR C0 tit CNTR. BUS 1 115 ED SQUARE D CD SC78 YES 100-1.01-L2 IIDT 4
F CS ells H t
1R24mitCC-112Y If0 TOR CONT CNTR. DUS 1 115 ED SQUARE D CO SC112 YES 108-1.01-L2 IIDT 4
F CS ells H 1R24mitCC1111 HOTOR CONT CitTR. BUS 1 115 ED SQUARE D CO SC40 YES 108-1.01-L2 IIDT 4
F CS.HS H 1224mitCC1112 It0 TOR CONT CHTR. BUS 1 115 ED SQUARE D CO SC113 YES 108-1.01-L2 ilDT 4
F CS.HS H 1224=llCC1113. It0 TOR C0tlT CNTR, BUS 1 115 ED SQUARE D CO SC113 YES 108-1.01-L2 ftBT 4
F CS.HS H 4
1R24mitCC1114 It3 TOR CONT CNTR. BUS 1 115 ED SQUARE D CO SC151 YES 108-1.01-L2 HDT 4
F CS.HS H l
1R24mitCC1117 f t0 TOR CONT CHTR. BUS 1 115 ED SQUARE D CO SC40 YES 108-1.01-L2 HDT 4
F CS.HS H 1R24ellCC1118 480 V It0 TOR CONT CENTE 115 ED SQUARE D CO SC113 YES 108-1.01-L2 IIST 4
F.
CS.HS H
,'b 1R24mitCC1119 480 V 110 TOR C0tlT CENTE 115 ED SQUARE D CD SC40 YES 108-1.01-L2 llDT 4
F CS.HS H 1R24ettCC1121 IIOTOR C0t4T CitTR. BUS 1 115 ED SQUARE D CD SC40 YES 108-1.01-L2 ItBT 4
F CS.HS H f'D
}
1R24mitCC1122 it0 TOR CONT CitTR. BUS 1 115 ED SQUARE D CO SC79 YES 108-1.01-L2 ItBT 4
F CS.HS H 1R2 4*lfCC1123 HOTOR CONT CitTR. DOS 1 115 ED SQUARE D C0 SC113 YES 108-1.01-L2 ItDT 4
F CS.HS H V
4 1R24mHCC1124
.IlOTOR CONT CH1R. BUS 1 115 ED SQUARE D CO SC151 YES 108-1.01-L2 11BT 4
F CS.HS H 1R24allCC1127 ft0 TOR CONT CitTR. BUS 1 115 ED SQUARE D CD SC40 YES 108-1.01-L2 ftDT 4
F CS.HS H
! L/
(
_ 1R24allCC1128 480 V ll0 TOR CONT CENTE 115 ED SQUARE D CD SC113 YES 108-1.01-L2 ItDT 4
F CS.HS H j U CS =COLO SitUT DollH P = PIPE 110UNTED SBT= sit!GLE FREQUEtiCY QUALIFICATION HILEST0tlES REVISION 11 - JUtlE 1983 4
D = DUCT ttOUNTED PC =PRIltARY CONT.
BIAXIAL TESTING A =REEVALUATIOtt C0ttPLETE s*'
DA =DYllAllIC AtlALYSIS PL : PEDESTAL SC =SEC0tIDARY C0tlT.
B = REQUEST FOR QUAL OR BID ISSUED fl0TE: fiUltBER Ill t
F = FLOOR I!OutlTED QP = QUALIFIED BY
/ = LOCATED 014 Colli.
C =S/H REcottifENDATIO!I TO LILCO
' TYPE ltTHG' COLUttH IS
!v HS = HOT STAtIDBY PIPING AtlALYSIS HALL D = QUAL DOC RECEIVED QUAtlTITY OF ITEllS.
1
_ItDT=lfULTI-FRECUCHCY SA = STATIC AtlALYSIS H =tlEITHER CS OR HS E =llARDilAPE It0DIFICATI0tl REQ'D s
j BIAXIAL TESTIllG SAT = SINGLE FREQUENCY F =00AL 00C APVO & FILED j
llST=ltULTI-FREQUENCY SIllGLE AXIAL TESTING G =SQRT PAPER CollPLETE A,,,j SIHCLC AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTION y
}
4 1' *
(N
\\
)
SHOREHAll 1
RB LIST ST0ttE & HEBSTER ENGItiEERI CORPORATIOrt RUti DATC 06/22/83 JOB HUtt0ED 11600 1-SORT REACTOR DUILDIf1G CATEGORY I FLOCC-It00HTED EQUIPi1EtiT RUtl TIltE 09.49.5%
(
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0t1 LEVEL (151 ITEllSI PAGE 4 IIARK FQUIPlIENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL NUffDER DESCRIPTION tiO.
RESP VEtIDOR ELEV IriSP REPT llETH FREQ flTilG SitTDH STATUS
(
1 24.flCC1129 480 V HOTOR CONT CEllTE 115 ED SQUARE D CO SC40 YES 108-1.01-L2 ItDT 4
F CS.HS 11 1r24 ItCC1131 il0 TOR CONT CitTR. BUS 1 115 ED SQUARE D CO SC63 YES 108-1.01-L2 ItDT 4
F CS ells H 1R24 altG-111 LPCI HG SET 439 ED LOUIS ALLIS SC150 YES t!E698 SA 27 F
H H
1R24mitG-112 LPCI ffG SET 439 ED LOUIS ALLIS SC150 YES IIE698 SA 27 F
tl II
(
IR24mitG-113 LPCI flG SET 439 ED LOUIS ALLIS SC150 YES ttE698 SA 27 F2 N
H 1R24=PflL-B1 480 VAC CHT BHR 115 ED SQUARE D C0 SC112 YES 8998-10.09-L23 ftDT 2 ')
F CS.HS If k
1R24mPtL-G1 400 VAC CHT BHR 115 ED SQUARE D CD SC112 YES 8998-10.09-L23 ttDT 22 F
CS.HS H IR24aPHL-R1 480 VAC CHT BHR 115 ED SQUARE D CO SC112 YES 8998-10.09-L23 IIDT 20 F
CS ells H 1R24mPHL-R2 480 VAC CHT BHR 115 ED SQUARE D CO SC112 YES 6990-10.09-L23
!!DT 20 F
CS.IIS 11 1%24mPtL-Y1 480 VAC CHT BHR 115 ED SQUARE D CD SC112 YES 8998-10.09-L23 ltDT 20 F
CS.HS H 0
1R24ePflL-01 480 VAC CHT BHR 115 ED SQUARE D CO SC78 YES 6998-10.09-L23 ItDT 20 F
CS.IIS H 1R24aPfL-02 400 VAC CHT BHR 115 ED SQUARE D CO SC78 YES 8998-10.09-L23 ItDT 20 F
CS.HS H l'
1R24mPitL-03 480 VAC CHT BHR 115 ED SQUARE D C0 SC78 YES 8998-10.09-L23 lint 20 F
CS.HS H 1R24aPitL-04 480 VAC CitTRL PHR FEED 115 ED SQUARE D CO SC112 YES 8998-10.09-L23 IIDT 20 F
CS.HS H l
IR24mPitL-111 LPCI SIP PHL 439 ED LOUIS ALLIS SC150 8'l-66829 ilDT 27 F
fl H
1R24mPtL-112 LPCI SIP Ptil 439 ED LOUIS ALLIS SC150 84-66829 ftJT 27 F
H H
(
1R24aPHL-113 LPCI SIP PflL 439 ED LOUIS ALLIS SC150 84-66829 ItDT 27 F2 il H
1R24mTRS111X LCPI ATS 438 ED ASCO SC112 YES 14606 itDT 13 F
CS.HS H
(
IR24eTRS112Y LCPI ATS 430 ED ASCO SC112 YES 14606 ItST 13 F
CS.HS H 1R35ePflL-B2 EllER 120 V PitL D2-SC 124 ED SYSTEH C0 tit SC112 YES 45322-1 ItDT 15 F
CS.IIS H L
s
_ 1R3S=Pf(L-R2 EllER 120 V PitL R2-SC 12r4 ED SYSTEtt CONT SC112 YES 45322-1 IIDT 15 F
CS.IIS 11
(,
CS = COLD StiUT DOHtt P : PIPE tt00HTED SBT= SINGLE FREQUEllCY QUALIFICATION HILESTONES REVISI0ti 11 - JUNE 1983 g
D =00CT lt0UtiTED PC =PRIllARY CONT.
CIAXIAL TESTItIG A = REEVALUATION CollPLETE DA =0Yt4AllIC AtlALYSIS PL : PEDESTAL SC =SEC0ttDARY CONT.
B = REQUEST FOR QUAL OR BID ISSUED fl0TE: fluttCER IH F = FLOOR tt0Ut4TED QP = QUALIFIED DY
/ = LOCATED ON CONT.
C =S/H REC 0ftltEllDATIOtt TO LILCO
' TYPE ItTitG' COLut1H IS V
IIS = HOT STAT 3DQY PIPIllG AFIALYSIS HALL D = QUAL DOC RECEIVED QUANTITY OF ITEllS.
s I!ST=litA.TI-FREQUENCY SA = STATIC At4ALYSIS H =NEITHER CS OR llS E =HAPDilARE It0DIFICATION REQ'D
~
DIAXIAL TESTIt4G SAT =SIIIGLE FREQUfHCY F = QUAL DOC APVD & FILED ltST=llULTI-FREQUEttCY SINGLE AXIAL TESTING.
G =SQRT PAPER COttPLETE V
SIllGLE AXIAL TESTIllG H = COPIES OF DOC TO DISTRIBUTION g
ce SHOREHAM UNIT 1 R3 LIST ST0llE & HEBSTER ENGIflEERING CORPORATI0tl RUN DATE 06/22/03 JOB flullDER 11600 1-SORT REACTOR BUILDIllG CATEG0f!Y I FLOOR-HOUllTED EQUIPifElli RUti TIltE 09.49.54
(
LILCO DOCHET 50.-322 ACTIVE BOP QUALIFICATION LEVEL (151 ITEllSt PACE 5 llARM EQUIPifENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL hut!BER DESCRIPTI0ft NO.
RESP VENDOR ELEV IllSP REPT HETH FREQ llTilG SHTDif STATUS 17:35mT-82 480-120/240V 1RANS 248 ED llAGilETICS SC112 YES HYLE 43424-1 llDT 9
F CS.HS H 1R35mT-R2 480-120/240V TRAt4S 248 ED HAGNETICS SC112 YES HYLE 43424-1 HDT 9
F CS.HS H 1R42mitCC-0A1 125 VDC ll0 TOR C0t4T CEH 168 ED GEN ELEC SC40 YES 79CPC005 SAT 100 F CS.HS H
,IR42mitCC-0A2 125 VDC ll0 TOR CONT CEN 168 ED GEN ELEC SC112 YES 79CPC005 SAT 100 F CS.HS H 1R42mtlCC-081 125 VDC ll0 TOR CONT CEN 168 ED GEN ELEC SC40 YES 79GPC005 SAT 100 F CS.llS H 1R42mifCC-082 125 VDC 110 TOR C0rlT CEN 160 ED GEN ELEC SC112 YES 79GPC005 SAT 100 F CS.HS H IT23mZ-EA1 REACTOR CONT ELEC PEH.134 EO GEN ELEC CO PC078 YES F73414 SAT 24 F
CS.HS H IT23mZ-EB1 REACTOR CollT ELEC PEN 456 ED Coll 4X PC078 YES IPS 453 SAT 24 F
CS.HS H
(.
4 J
IT23mZ-EB2 REACTOR C0 tit ELEC PEtt 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F
CS.HS H IT23mZ-ED5 REACTOR C0 tit ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F
CS.HS et L
IT23mZ-ED6 REACTOR C0 tit ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F
CS.HS H j
IT23mZ-HB3 REACTOR Colli ELEC PEH 456 ED CollAX PC078 YES IPS 453 SAT 24 F
CS.HS H l
IT23mZ-llD4 REACTOR CONT ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F
CS.HS H a
1T23mZ-HC4 REACTOR CONT ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F
CS.!!S H IT23mZ-HD1 REACTOR CONT ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F
CS.HS H 1T23mZ-ilD2 REACTOR C0f(T ELEC PEH 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F
CS.HS Il O
IT46mA00040 RB REFUEL LVL EXHAUST 319 CD P0HERS REGUL SC154 YES 44540-1 SA/ SAT 40 F2 CS H
4 IT46mA00041 RB POT CCHTAtt AREA EXH 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 CS.HS H LJ
}
IT46mCLC-05 RBSVS C00LIllG COILS 276 PD BUFFALO FORGE SC113 YES 80H-27781 SA 5
F2 CS.HS H IT46mFLT-01 RBSVS FILTER TRAINS 105 PD FARR C0 SC112 YES D-56291 SA/ SAT 11 F2 CS.HS H
_ 1T46mFil-003 RB EXH FANS-RDilVS 270 PD BUFFALO FORGE SC124 YES 743-11136 SA 15 F3 CS H
5 V
CS = COLD SitOT 0084tl P = PIPE tt0UNTED SBT=SIllGLE FREQUEllCY QUALIFICATIOtt HILESTotlES REVISI0tl 11 - JUilE 1983 s
l 0 = DUCT IIOUtiTED PC =PRIllARY C0 tit.
DIAXIAL TESTIrlG A =REEVALUATI0tt CottPLETE DA =DYllAtIIC AtlAl.YSIS PL :PEDESTAI.
SC =SECollDARY C0t4T.
B = REQUEST FOR QUAL OR BID ISSUED fl0TE: flul! DER It4 F = FLOOR 110UtlTED OP = QUALIFIED BY
/ = LOCATED Off CotiT.
C =S/lf RECollitEtIDAT10!I TO LILCO
' TYPE HitlG' COLuitti IS y
its =110T STAT;DDY PIPIllG AtlALYSIS HALL D = QUAL DOC RECEIVED QUAtlTITY OF ITCitS.
ItDT=tfULTI-FREQUEllCY SA = STATIC AtlALYSIS H =tlEITIIER CS OR HS E =HARDilARE liODIFICATION REQ'D l
~
BIAXIAL TESTItiG SAT =SIflGLE FREQUEHCY F = QUAL 00C APVD L FILED flST=ttULTI FREQUEffCY SIriGLE AXIAL TESTING
- G =SQRT PAPER C0ttPLETE i
SIllGLE AXIAL TESTING H = COPIES OF DDC TO DISTRIBUTION
,~
(V)
Sit 0REH T1 R3 LIST STOsiC & HEESTER ENGIllE
)COPPORATI0tt RUH DATE C6/22/83 JOB HutZEJ 11600 1-SORT CEACTOR DUILDING CATEGORY I FLJ-It00f4TED EQUIP!!EtlT RUti TIttE 09.49.54
('
LILCO DOCHET 50-322 ACTIVE DOP QUALIFICATI0tl LEVEL (151 ITEllS t PAGE 6 ItARM EQUIPlfElli SPEC DIV.
ELDG AVAIL QUAL QUAL TYPE SAFE QUAL flUtlDER DESCRIPTION H3.
RESP VEtt00R ELEV IttSP REPT llETH FREQ ilTilG SHTDH STATUS
(
1T46eFH-079 RD EXH 000 STER FAtt 102 PD DUFFALO FORGE SC133 YES 745-4244C SA S1 F2 CS llS 11 IT46*FT 004 ROSVS EXH AIR FLOH 319 CD POHERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 II H
IT46*tlE 002 FLT-1 tt0ISTURE 319 CD P0HERS REGUL SC112 YES 43812-1 SA.' SAT 24 F2 ft H
1T46*tt00031 RBSVS IllLET TO llIX PLH 319 CD P014ERS REGUL SC135 YES 43812-1 SA/ SAT 24 F2 CS HS 11 IT46 att00034 RBSVS FILTER TRAIN DCil 319 CD POliERS REGUL SC182 YES 44540-1 SA/ SAT 60 F2 CS H
IT46 alt 00036 Fil-3 DISCHARGE AIR 319 CD P0HERS REGUL SC126 YES 43012-1 SA/ SAT 24 F3 CS.IIS 11 k.
1T46elt00047 FN-79 DISCHARGE AIR 319 CD POHERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 ti H
1T46mit00048 FLT-1 It4LET AIR 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 H
H h
IT46mPDSO45 FH-3 DIFF PRESSURE 319 CD P0HERS REGUL SC112 YES 43012-1 SA/ SAT 24 F2 CS.HS 11 IT46mPDSO46 Fil-3 DIFF PRESSURE 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F3 CS HS H b'
1T46mPDT003 FLT-1A DIFF PRESSURE 406 CD ROSEtt0UtiT SC112 YES 127516 If3T 60+
F2 CS.HS H IT46aPDT043 REACTOR BLOG DIFF 406 CD ROSEtt0UtlT SC220 YES 127516 ItDT 60+
F2 CS.HS H
,(*
IT46mTE 001 RDSVS RECIRC AIR TEttP 406 CD ROSElt00t4T SC144 YES 2767 SAT 60+
F2 CS.HS H IT46mTE 006 TEttP. ELEttElli 406A CD C0ftAX SC048 YES IPS-805 ItDT 60+
F CS.HS F k.'
1T46mTE 022 AIR RETURH TO UC-2 406 CD ROSEtt0Ut4T SC10 YES 2767 SAT 60+
F2 CS ells H IT46mTE 023 AIR RETURH TO UC-3 406 CD ROSEtt0UtiT SC42 YES 2767 SAT 60+
F2 CS.HS H ke IT46mTE 024 AIR RETURil TD UC-4 406 CD ROSEl100tlT SC220 YES 2767 SAT 60+
F2 CS ells H IT46mTE 025 AIR RETUnti TO UC-S 406 CD ROSEtt0UtiT SC220 YES 2767 SAT 60+
F2 CS elfS H
(.
IT46 ATE 028 ftCC Rif UNIT COOLER 406 CD POSEtt0UtiT SC128 YES 2767 SAT 60+
F2 CS.HS 11 IT46mTE 059 mOC-21 UNIT CLR 406 CD ROSEll0UNT SC155 YES 2767 SAT 60+
F2 CS HS H v
_ 1T46mTE 060 aUC-22 UtlIT CLR 406 CD ROSEll0UNT SC160 YES 2767 SAT 60+
F2 CS.HS H v
PIPE tt0UNTED SBT= SINGLE FREQUEllCY QUALIFICATI0tl llILEST0tlES REVISIOtt 11 - JUttE 1983 0 = DUCT 1100tiTED PC =PRIttARY CollT.
BIAXIAL TESTIt1G A =REEVALUATI0tl CottPLETE DA =DYllAltIC AtlALYSIS PL : PEDESTAL SC =SEC0!!DARY C0f(T.
B = REQUEST FOR QUAL OR BID ISSUED ff0TE: ilUtIDER IH F = FLOOR 110Ut4TED QP = QUALIFIED BY
/ = LOCATED Ott 00t4T.
C =S/H REC 0f ttlEt:0ATI0tl TO LILCO
' TYPE llTUG' COLUttH IS U
!!S = HOT STAtsDDY PIPIllG At4ALYSIS HALL D =0UAL 00C RECEIVED QUAllTITY CF ITEllS.
ItDT=t tUL TI-F R EQUEtiCY SA = STATIC AtlALYSIS H =ttEITHER CS OR HS E =flAPDllARC tt0DIFICAT10ti REQ'D C
DIAXIAL TESTIttG SAT =SIllGLE FREQUEttCY F = QUAL DOC APVD & FILED ttST=t fULTI-F R EOt tEliCY SINGLE AXIAL TESTItiG G = CORT PAPER CollPLETE V
sit 4GLE AXIAL TESTING H : COPIES OF DOC TO DISTRICUTI0tl
\\e..
\\
SHOREHAH
/1 EB LIST STONE & HEBSTED ENGINEED b (0RPORATION RUN DATE 06/22/83 JOB HUHDEn7 1600 1-50RT REACTOR DUILDING CATEGORY I FLOO'-IIOUNTED EQUIPHENT RUN TIltE 09.49.54
(
LILC3 DOCHET 50-322 ACTIVE DOP QUALIFICATION LEVEL (151 IT[llSI PAGE 7
)
J IIARN EQUIPitENT SPEC DIV.
BLDG AVAIL QUAL QUAL TYPE SAFE QUAL HUltBER DESCRIPTION HO.
RESP VENDOR ELEV IllSP REPT llETH FREQ HTilG SHTON STATUS
)
1T44mOC-002 UNIT COOLERS-RDSVS 276 PD BUFFALO FORGE SC8 YES 80N-27781 SA 5
F2 CS.HS H 4
IT46muC-003 UNIT COOLERS-RDSVS 274 PD BUFFALO FORGE SC006 YES 80N-27701 SA 5
F2 CS,HS H
.)
ITtenUC-004 UNIT COOLERS-ROSVS 274 PD BUFFALO FORGE SC175 YES 80N-27781 SA 5
F2 CS.HS H 1T44mOC-005 UNIT COOLERS-RBSVS 276 PD BUFFALO FORGE SC175 YES 80N-27781 SA 5
F2 CS.HS H
)
IT46.UC-020 UNIT COOLERS-IICC IN RS 276 PD BUFFALO FORGE SC112 YES 80H-27181 SA 5
F2 CS.IIS H 1746mUC-021 UNIT COOLERS 276 PD BUFFALO FORGE SC150 YES 80H-27781 SA 5
F2 CS,HS H Y
.h,.
1Tt4.UC-022 UNIT COOLERS - RBSVS f.76 PD BUFFALO FORGE SC161 YES 80N-27781 SA 5
F2 CS.HS H 1T46muC-023 UNIT COOLER HCC RS 276 PD DUFFALO FORGE SC040 YES 80N-27903-4 SA 5
F N
H
).
1T48mFT 005N HEPA FILTER INLET 406 CD ROSElI0UNT SC113 YES 127514 SAT 60+
F2 CS HS H IT48mLS 061 COND LEVEL 407 CD ftAGNETROL SC77 YES 43235-1 IIDT 17 F2 HS H
l i
IT48mPHL-48 HYO REC 0tB P0HER CABIN 289 PD AT0ttICS INT SC112 YES 50003 ItBT 14 F2 N
H J'
IT48mPtL-68 GAS ANALYZER-DRYHELL 344 PD DELPHI IND SC112 YES 1035-1 ftBT 18 F2 N
H l
1TR8sPt8.-69 GAS ANALYZER-SUPPR CHH 344 PD DELPHI IND SC112 YES 1035-1 liBT 18 F2 tl H
-)
i 1T48mRC-002 HYD REC 0tm UNIT 289 PD ATOHICS INT SC112 YES 54591-2 IIDT 14 F2 N
H
- kJ 1Z93 LT 001 SUPPRESSION POOL LEVEL. 406 CD ROSEll0UNT SC8 YES 127516 SAT 60+
F2 CS.HS H V.
i i
1Z93mPT 003 DRYHELL PRESSURE 406 CD ROSEll0UNT SC98 YES 108025 ftDT 60+
.1Z93ePT 004 SUPP POOL PRESS 406 CD ROSEl100HT SC40 YES 1080Z5 IIDT 60+
F2 CS HS H
,j 1Z93mTE 110 RV092ACL DIScitARGE-1FT 406 CD ROSEttoutiT PC28 YES 17607-1 teT 60+
F4 H
H
- b IZ93 ATE 111 RV09280E DISCHARGE-1FT 406 CD ROSEll0UNT PC28 YES 17607-1 HST
- t. 3 + F4 H
H a
IZ93mTE 112 RV092HG DISCHARGE-1FT 406 CD ROSEtt0UNT PC28 YES 17607-1 IIDT 60+
F4 H
H
!b 3
_ 1293mTE 113 RV092FHJ DISCHARGE-1FT 406 CD ROSEtIOUNT PC28 YES 17607-1 ftBT 60+
F4 N
H r.)
4/
CS = COLD SHUT DOHN P = PIPE tt0UNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 11 - JUNE 1983 J'
I D =00CT IIOut4TED PC =PRIllARY CONT.
BIAXIAL TESTIttG A =REEVALUATI0tl COttPLETE DA =DYt4MlIC AllALYSIS PL = PEDESTAL SC = SECONDARY CONT.
B = REQUEST FOR QUAL OR BID ISSUED P401E: NUtIDER IN F = FLOOR fl00HTED QP = OUALIFIED BY
/ = LOCATED ON CONT.
C =S/H REcoll!!EllDATION TO LILCO
' TYPE ttrifG' COLUt!N IS jV HS =ttOf STAHOSY PIPING ANALYSIS HALL D = QUAL 00C RECEIVED QUAtlTITY OF IT[llS.
s.)
IIDT=ltVLTI-FREQUEHCY SA = STATIC ANALYSIS H =HEITHER CS OR IIS E =HARDHARE tt00IFICATION REQ'D 4 - 5 BIAXIAL TESTIllG SAT = SINGLE FREQUEllCY F = QUAL DOC APVD 1 FILED ItST=ltULTI-F REQUEllCY SINGLE AXIAL TESTING G =SQRT PAPER C0ftPLETE D
sit 4GLE AXIAL TESTING J
H = COPIES OF 00C TO DISTRIDUTIDH i
ysi.
0, J
SHOREHAll UNIr 4 KB LIST STottC & HEDSTER ENGINEERIllC CORPORATION JOB NutZE2 11600 1-SORT.
REACTOR DUILDIllG CATEGORY I FLOOR-1100HTED EQUIPifENT RUN DATE 06/22/C3 RUN TIltE 09.49.S4 LILCD DOCHET S0-322 ACTIVE LOP QUALIFICAT10tl LEVEL (151 ITEHS)
PAGE 8
- IIARN EQUIPifEtif SPEC DIV.
CLDG AVAIL QUAL QUAL TYPE SAFE QUAL tlUtt3Elt CESCRIPTION FIO.
RESP VEFIDOR ELEV ItiSP REPT
!!ETH FREQ llTtlG SitTDil STATUS IZ93sTE 132 RV092ACL DISCHARGE-2FT' 406 CD ROSElt00 tit PC28 YES 17407-1 IfDT 40+
F2 N
H s
?
1Z93nTE 133 RV09200E DIScalARGE-2FT 406 CD ROSElt0UNT PC28 YES 17607-1 110T 60+
F2 N
H 1Z93m1E 134 RV092HG DISCHARGE-2FT 8106 CD ROSElt0UllT PC28 YES 17607-1 ftBT 60+
F2 N
11
,)
1Z93mTE 13S RV092FHJ DISCHARGE-2FT 456 CD ROSElt0UteT PC20 YES 17607-1 ftDT 60+
F2 N
H
,)
)
i 1
J
-J J
4 J
- ~
.)
CS = COLD SHUT DOHN P = PIPE lt00tlTE3 SBT=SIllGLE FREQUENCY QUALIFICATI0tl itILESTotlES REVISION 11 - JUNE 1983 D = DUCT lt0UtiTED PC =PRItIARY COtlT.
BIAXIAL TESTitlG A =REEVALUATIOtt CottPLETE
,/
DA =DYllAttIC At4ALYSIS PL = PEDESTAL SC =SEC0tIDARY C0 tit.
B = REQUEST FOR QUAL OR DID ISSUED fl0TE: IIUl:0ER Ill F = FLOOR lt0UtlTED QP = QUALIFIED BY
/ = LOCATED Ott CotiT.
C =S/H REC 0f tttEFIDATI0tl 10 LILCO
' TYPE IITitG' COLUttti IS lis =ll0T STAT 0DY PIPIllG AtlALYSIS HALL D = QUAL 00C RECEIVED flDT=ltUL TI-FR EQUEtlCY SA = STATIC AtlALYSIS H =tlEITilER CS OR HS QUAtlTITY OF ITEf tS.
7 BIAXIAL 1ESTIrlG SAT =SItIGLE FREQUEtiCY E =llARDilARE !!ODIFICATI0tt REQ'D v
itST=t1ULTI-FREQUEtiCY SIttGLE AXIAL TESTIttG F = QUAL DOC APVD A FILED G =SQRT PAPER C0ftPLETE o
SillGLE AXIAL TESTIrlG if = COPIES OF DOC TO DISTRIBUTION J
1 O
O O
Cf0REHAM LaT 1 RDPH LIST STONE & HEESTE2 ENGINEERING CORPORATION RUM DATE 06/22/83 JOB NUBBE2 11400 1-30RT REACIW DUILDIllG CATEGORY I PIPE ttoutiTED EQUIPHENT RUN TIllE 09.49.51 (i LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (393 ITEHS)
PAGE 1 5
7 8
(
1 2
3 4
DPER LOAO-G'S OPERATOR 6
QUAL STATUS HARH PIPE QUAL SPEC LOC.
HOR VER SUPPLIER HODEL NO.
YOHE OPER L,
.IB21mHOV031 3/1 SR-6060 B8V PC 2.3
.8 LIMITORQUE SFB-00-10 H
H 1821mHOV032 3/1 SR-6060 88V SC 3.3 1.3 LIMITORQUE stb-000-5
- H H
(,
1821mHOV034 3
SR-4060 88V SC 1.2 2.1 LIHITORQUE Ste-00-7.5 H
H 1821mHOV035A 20/1 20-1500GLO9 88AD SC 2.8 1.1 LIMITORQUE Ste-1-40 H
H lh 1521mHOV035B 20/1 20-1500GLO9 88AD SC 3.9 2.2 LIHITORQUE SIIB-1-40 H
H 1821mHovo61 2/1 SR-6188 253 SC 1.8 1.0 LIHITORQUE stb-00-10 H
H h
IB21mHOV062 2/1 SR-6188 253 SC 1.4 1.7 LIMITORQUE SHB-00-10 H
H l
]
1821mHOV063 2/1 SR-6188 253 SC 2.0 1.2 LIMITORQUE SIB-00-10 H
H l (p 1821mHOV064 2/1 SR-6188 253 SC 1.8 1.2 LIMITORQUE SFB-00-10 H
H 1821stt0V068A 2/1 SR-6188 253 SC 1.4
.9 LIMITORQUE SHB-000-5 H
H h
1821mHOV0608 2/1 SR-6188 253 SC 1.5 1.8 LIHITORQUE stb-000-5 H
H 1821mHOV060C 2/1 SR-6188 253 SC 1.8
.9 LIHITORQUE Ste-000-5 H
H h
1821mit0V0600 2/1 SR-6188 253 SC 1.4 1.1 LIHITORQUE stb-000-5 H
H ID21mHOV083 2/1 SR-6108 253 PC 3.0 2.7 LIMITORQUE SIB-000-5 H
H 5 h 1821mHOV084 2/1 SR-6188 253 PC 4.9 2.0 LIMITORQUE SIB-000-5 H
H i
IB21eHOV085 2/1 SR-4188 253 PC 4.3-1.9 LIMITORQUE SHB-000-5 H
H I
Q IB21mSOV313A
.75 F5t5265683271 600 SC 1.5 1.3 H
1821mSOV3138
.75 65tS265683271 600 SC 1.5 1.3 H
i i (/
IB21mSOV314A
.75 0425265683271 600 SC 1.5 1.3 H
~
QUALIFICATI0H HILESTONES NOTES REVISION 11 - JUNE 1983 i O A = REEVALUATION CCl5'LETE
- 1. CL 2 AND 3 VALVES < OR = 2 IN. ARE j
B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED IEHTP-9.5)
{
C =S/H RECatstENDATION TO LILCO
- 3. CL 1 VALVES < OR = 1 IH. ARE E=HAR0l!ARE ItODIFICATION REQ'O FLOOR-IlOUNTED (EH1P-9.5)
I F = QUAL 00C APVD & FILED
- 4. 2/1 = 2 IH. CLASS 1
}
G =SQRT PAPER COHPLETE L.
H = COPIES OF DOC TO DISTRIBUTION I
(%
\\
b
]
SHOREHAH b /1 RBPH LIST STONE 1 HEBSTER EllGINE (G CORPORATIDH RUH DATE 06/22/83 JOB HUtBER 11600 1-SORT REACTOR BUILDING CATEGORY I PIPE It0UNTED EQUIPHEHT Ruti tit!E C9.49.51
(,
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION * *. VEL (393 ITEHS)
PAGE 2 l
5 7
8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS HARH PIPE QUAL SPEC LOC.
HtRIBER SIZE REPT 10.
HOR VER SUPPLIER HODEL NO.
YOHE OPER
(
IB21mSOV314B
.75 HR5265683271 600 SC 1.5 1.3 Il 1031mA0V081
.75 10.3.115 318 PC 6.9 3.0 COPES D-100-60 H
H
(*
IB31mA0V082
.75 10.3.115 318 SC 1.5 1.3 COPES D-100-60 Il 11 IC41 MRV 021A 1.5 502644 191 SC 2.1 2.0 H
(.*
IC41 MRV 021B 1.5 502644 191 SC 1.9 1.8 H
ID11mHOV032A 1
SR-6190 253 PC 2.3 2.3 LIHITORQUE StID-000-2 11 It b
3011ml10V0328 1
SR-4190 253 SC 2.3
.7 LIttITORQUE St B-000-2 H
H ID11mHOV033A 1
Sit-6190 253 PC 2.3 2.5 LIttITORQUE St B-000-2 H
H
(#
1011mHOV0330 1
SR-6190 253 SC 2.3
.7 LIltITORQUE stb-000-2 H
H IE11mA0V061A
.75 10.3.115 318 SC 2.3
.7 COPES D-100-6 0 H
H
(/
1E11mADV0618
.75 10.3.115 318 SC 2.3
.7 COPES D-100-60 H
H IE11mA0V062A
.75 10.3.115 310 SC 2.3
.7 COPES D-100-60 H
H b
IE11mA0V0620
.75 10.3.115 318 SC 2.3
.7 COPES D-100-60 14 H
IE11mHOV031A 20 E5036-1,2 88AD SC 6.8 1.1 LIHITORQUE St B-0-40 H
H b
IE11mHOV031B 20 E5836-1,2 88AD SC 4.6
.9 LIttITORQUE SHD-0-40 H
H IE11mit0V031C 20 E5836-1,2 80AD SC 7.6
.5 LIHITORQUE StfD-0-40 H
H D
IE11mHOV031D 20 E5836-1,2 88AD SC 4.4
.9 LIHITORQUE stb-0-40 H
H IE11mit0V032A 20 E5036-1,2 88AD SC 5.1 1.8 LIllITORQUE SHb-0 -40 if H
Y 1E11mHOV0328 20 E5836-1,2 88AD SC 2.8 2.7 LIllITORQUE SIB-0-40 H
H s
QUALIFICATI0tl HILESTot4ES tt0TES REVISIOtt 11 - JUNE 1983 V
A =REEVALUATIOil C011PLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 IH. ARE 8 = REQUEST FOR QUAL OR DID ISSUED FLOOR-it0UtfTED ( EttTP-9.5 3 C =S/H REC 0tslENDATION TO LILCO
- 2. * = DC t10 TOR.
ALL OTHERS ARE AC U
D = QUAL 00C RECEIVED
- 3. CL 1 VALVES < OR = 1 IH. ARE s
E=HAR0 HARE ttDDIFICATIOtt REQ'D FLOOR-it0UNT[D (EllTP-9.5)
I F =0UAL 00C APVD & FILED
- 4. 2/1 = 2 IH. CLASS 1 G =SQRT PAPER COHPLETE V
H = COPIES OF DOC TO DISTRIBUTI0tl s
t
m
/
i I
(
/
\\
/
v SHOREHAM L d 1 RDPH LIST STotIE & HEDSTER ENGINEERING CORPORATICH RtRt DATE 06/22/83 JOB I4UtBE211600 1-SORT REACTOR DUILDIttG CATEGORY Z PIPE HOUNTED EQUIPitENT RUtt TIttE 09.C9.51 h LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (393 ITElts)
PAGE 3 5
7 8
b 1
2 3
4 OPER LOAD-G'S OPERATOR 6
QUAL STATUS HARH PIPE QUAL SPEC LOC.
HLA BER SIZE REPT NO.
HOR VER SUPPLIER HODEL tiO.
YCHE OPER b
IE11mHOV032C 20 E5836-1,2 80AD SC 5.4 6.7 LIHITORQUE SIB-0-40 H
H 1E11mHOV032D 20 E5836-1.2 80AD SC 2.6 3.9 LIMITORQUE S10-0-40 H
H h
IE11mit0V033A 16 SR-6266 88V SC 2.9 1.4 LIHITORQUE
$10-1 40 II H
1E11mlBV033B 16 SR-6266 88V SC 2.4 1.8 LIllITORQUE S110 6 0 it if h
IE11 mil 0V034A 18 18-300A 88AD SC 2.0 1.7 LIMITORQUE S!!D-3-150 H
H IE11mHOV034B 18 18-300A 88AD SC 1.9 1.3 LIHITORQUE S!B-3-150 H
H b
IE11mHOV035A 14 SR-6266 80V SC 2.4 1.6 LIllITORQUE stb-1-60 11 H
IE11mHOV035B 16 SR-6266 88V SC 2.2 2.3 LIllITORQUE St B-1-60 H
H h
IE11mit0V036A 24 E5836-19 88AD SC 3.8 3.0 LIllITORQUE S10-4-200 H
11 1E11mit0V036B 24 E5836-19 88AD SC 7.6 2.2 LIllITORQUE SIB-4-200 H
H b
IE11mlBV037A 24/1 2422900GTO7 88AD SC 5.5 6.6 LIllITORQUE SD-4-200 H
II IE11mit0V037B 24/1 2422900GT07 88AD SC 4.7 5.0 LINITORQUE SD-4-200 H
H h
IE11mit0V038A 10 E5836-20 80AD SC 5.7 1.3 LIllITORQUE stb-2-60 H
H IE11mit0V0383 10 E5836-20 88AD SC 3.5 1.5 LIMITORQUE stb-2-60 ll 11 l b IE11mit0V039A 10 SR-6082 88V SC 6.8 2.3 LIHITORQUE S10-0-25 F
F 1E11mHOV0398 10 SR-6082 88V SC 4.5 3.8 LIllITORQUE stb-0-25 H
H O
1E11mHOV040A 16 SR-6266 88V SC 9.7 7.9 LIllITORQUE SIB-1-60 H
H l
1E11mHOV040B 16 SR-6266 88V SC 9.0 3.7 LIMITORQUE SHD-1-60 H
H
,V 1E11mit0V041A 6
SR-6177 88V SC 1.9 1.2 LIMITORQUE S10-00-15 H
H s
QUALIFICATI0tl HILESTOMES 110TES REVISI0tt 11 - JUNE 1903 iV A =REEVALUATIOff CottPLETE
C =S/H REcot5tENDATI0tl TO LILCO
- 3. CL 1 VALVES < OR = 1 Ill. ARE E=llARDHARE It0DIFICATION REQ'D FLOCR-IBUNTED (ElfrP-9.51
{
F = QUAL DOC APVD & FILED
- 4. 2/1 = 2 IH. CLASS 1 G = SORT PAPER CottPLETE i!V H = COPIES OF DOC TO DISTRIBtJTION s
l is>
u
'(
(N O
h SHOREHAM RBPH LIST STONE & HEDSTE"! EtlGIIIEE_.e3 CORPORATION RUN DATE 06/22/83 JOB NUllDED 11600 1-SCRT CEACTOR BUILSING CATEGORY I PIPE IlOutiTED EQUIPilENT Rut! TIllE 09.t9.51 L
LILCO DOCHET 50-322 ACTIVE DOP QUALIFICATI0tl LEVEL (393 ITEllS)
PAGE 4 5
7 8
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS HARM PIPE QUAL SPEC LOC.
HUllBER SIZE REPT HO.
HOR VER SUPPLIER HODEL 110.
YO:(E OPER 1E11mHOV041B 6
SR-6177 88V SC 8.5 3.1 LIllITORQUE Ste-00-15 F
F 1E11mHOV042A 16 E5836-4 88AD SC 4.0 5.1 LIllITORQUE Ste-3-80 H
H
(
IE11 mil 0V0428 16 E5836-4 88AD SC 3.1 4.2 LIH1 TORQUE SiO-3-80 H
H IE11mHOV043A 4
SR-6180 88V SC 1.2
.6 LIMITORQUE
$10-00-15 H
H k
1E11mlIOV0438 4
SR-6180 80V SC 1.9
.9 LIllITORQUE SIB-00-15 H
H IE11mHOV044A 4
SR-6180 80V SC 1.6
.6 LIllITORQUE SilD-00-15 II H
k' 1E11mHOV044B 4
SR-6100 88V SC 1.5 1.3 LIllITORQUE SIID-00-15 H
H IE11ml10V045A 4
SR-6180 88V SC 1.4 1.1 LIHITORQUE SilD-000-5 H
H b
IE11mHOV0458 4
SR-6180 88V SC 3.3 1.5 LIllITORQUE S!ID-000-5 H
H IE11mHOV047 20/1 20900-GT06 88AD PC 5.6 3.2 LIllITOROUE 50-2-60 H
H
'b IE11mHOV048 20/1 20900-GT06 80AD SC 3.8 3.0 LIMITORQUE SD-2-60 m H
H IE11mHOV049 10 SR-6260 80V SC 2.4 1.8 LIllITORQUE SHD-2-80 H
H b
IE11ml10V050 20 SR-6425 88V SC 9.8 4.3 LIMITCRQUE SilD-2-60 B
F IE11ml0V051 4
SR-6180 88V SC 1.1 1.0 LIllITORQUE S18-00-7 1/2 m
H 11 b
IE11mHOV052 4
SR-6100 83V SC 1.6 1.2 LIllITORQUE S10-00-10 II H
IE11 mil 0V053 4
SR-6068 88V SC 4.4 2.7 LIllITORQUE SIID-00-10
- 11 11 b
IE11mHOV054 4/1 SR-6068 80V PC 4.6 1.5 LIllITORQUE S!D-00-15 H
ll 1E11ml10V055A 1
SR-6190 253 SC 2.3
.7 LIIIITORQUE SID-000-2 H
H lV IE11mHOV055G 1
SR-6190 253 SC 2.3
.7 LIllITORQUE SID-000-2 H
H QUALIFICATI0H HILEST0tlES tl0TES REVISION 11 - JUllE 1903
,V A =REEVALUATI0tl CollPLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 Ill. ARE B = REQUEST FOR QUAL OR DID IS!AJED FLOOR-It0UtiTED (EllTP-9.5)
C =S/it REC 0lt1EFDATI0tt TO LILCO
' b/
0 = QUAL DOC RECEIVED
- 3. CL 1 VALVES < OR = 1 IH. ARE E=HARDilARE IfCDIFICATICtl REQ'D FLOOR-l!OUllTED IEllTP-9.53 I
F = QUAI. Doc APVD & FILED
- 4. 2/1 = 2 Ill. CLASS 1 G =SQRT PAPER CO!!PLETE 1 b/
H = COPIES OF DOC TO DISTRIBUTIDH 6
- - _ _.. = _ - - _ _ _ _ - - _ _ - _ - _.
SHOREHAH R f 1 EBPH LIST ST0tlE & HEBSTE2 ENGIhIHG CORPOR* TION RUN DATE 06/22/83 JOB HUISE211600 1-50RT REACTOR CUILDING CATEGORY I PIPE lt0UNTED EQUIPHENT RUN TIllE 09.49.51
(.'
LILCO DOCHET 50-322 ACTIVE BOP CUALIFICATION LEVEL (393 ITEllS)
PAGE 5 5
7 8
k' 1
2 3
4 OMR LOAD-G'S OPERATOR 6
QUAL STATUS 4
ItARK PIPE CUAL SPEC LOC.
HtABER SIZE REPT NO.
It0R VER SUPPLIER ltODEL HO.
YOHE OPER b-1E11mHOV056A 1
SR-6190 253 SC 2.3
.7 LIHITORQUE SIB-000-2 H
H IE11mHOV0568 1
SR-6190 253 SC 2.3
.7 LIllITORQUE Ste-000-2 H
H b
IE11mHOV057A 1
SR-6190 253 SC 2.3
.7 LIHITORQUE SIID-000-2 H
H 1E11 mil 0V0578 1
SR-6190 253 SC 2.3
.7 L1HITORQUE SitD-000-2 H
H b
IE11mPCV003A le 10.3.115 310 SC 2.6 1.9 COPES D-100-160 H
H IE11mPCV003B 10 10.3.115 318 SC 1.0
.6 COPES D-100-160 H
11 b
IE11mPCV007A 4
10.3.115 318 SC 1.2
.9 COPES D-100-100 H
H IE11mPCV0078 4
10.3.115 318 SC
.8 1.7 COPES D-100-100 H
H
(..
1E11 MRV 151A 1
502644 191 SC 1.5 1.3 H
)
IE11 MRV 1518 1
502644 191 SC 1.5 1.3 H
(.
1E11 MRV 151C 1
502644 191 SC 1.5 1.3 H
IE11 MRV 151D 1
502644 191 SC 1.5 1.3 H
b IE11 MRV 152A 4
502644 191 SC 4.0 2.3 H
IE11 MRV 1528 4
502644 191 SC 1.1
.9 H
D 1E11 MRV 153A 1
502644 191 SC 1.5 1.3 H
IE11 MRV 1538 1
502444 191 SC 1.5 1.3 H
4/
1E11 MRV 154 1
502644 191 SC 1.5 1.3 H
s 1
l IE11 MRV 155 2
502644 191 SC 1.5 1.3 H
1 IE11*RV162A 1
502644 191 SC 1.5 1.3 H
s
~
QUALIFICATION HILESTONES NOTES REVISIGH 11 - JUNE 1983
- v l
A =REEVALUATIDH C0tFLETE
- 1. CL 2 AFD 3 VALVES < OR = 2 IH. ARE j
B = REQUEST FOR QUAL OR BIO ISSUED FLOOR-it0UNTED (EHTP-9.5) j C 5/H REcotRIEIR)ATION TO LILCO
- (/
D = QUAL DOC RECEIVED
- 3. CL 1 VALVES < OR = 1 IH. ARE E=HARDIIARE IlODIFICATION REQ'D FLOOR-l10UitTED (EliTP-9.5)
~
1 F = QUAL DOC APVD & FILED
- 4. 2/1 = 2 IH CLASS 1 G =SQRT PAPER C04tPLETE i
V H = COPIES OF DOC TO DISTRIBUTION i
i i
ks
r
['O) g s
G SHOREt IIT 1 RBPH LIST STottE 1 HEBSTER Et1G ERING CORPORATION Rtti DATE 06/22/;3 JOD hut 2ER 11600 1-SCRT REACTOR DUILCING CATEGORY I PIPE il0UtlTED EQUIPitEtiT RUtt TIllE 09.49.51
('
LILCO DOCHET 50-322 ACTIVE DOP QUALIFICATION LEVEL (393 ITEllS)
PAGE 6 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS itARH PIPE QUAL SPEC LOC.
tiUtBER SIZE REPT tt0.
HOR VER SUPPLIER
- 100EL NO.
YONE OPER
(
IE11 MRV 1628 1
502644 191 SC 1.5 1.3 H
IE11 MRV 163
.75 502644 191 SC 1.5 1.3 H
b IE11 MRV 164
.75 502644 191 SC 1.5 1.3 II IE11mSOV166A
.75
>R5265683271 600 SC 1.5 1.3 11 b
IE11mSOV166B
.75 6125265683271 600 SC 1.5 1.3 H
IE11*SOV167A
.75 tR5265683271 600 SC 1.5 1.3 H
b IE11mSOV1678
.75 HRS 265683271 400 SC 1.5 1.3 H
IE11mSOV168
.75 tR5265683271 600 SC 1.5 1.3 H
b IE11mSOV169
.75 HRS 265683271 600 SC 1.5 1.3 H
IE21mHOV031A 14 E5836-7 08AD SC 2.4 2.0 LIllITORQUE St B-000-5 H
H b
IE21mHOV031B 14 E5833-7 OOAD SC 3.5
.6 LIHITORQUE SID-000-5 H
11 IE21mit0V033A 10/1 SR-6259 88V SC 6.9 1.2 LIllITORQUE SilD-2-80 H
H b
IE21stt0V033B 10/1 SR-6259 80V SC 7.6 2.5 LIttITORQUE SIB-2-00 H
H 1E21stt0V034A 3
SR-6183 88V SC 1.4
.5 LIMITORQUE stb-000-5 11 H
b 1[21mfl0V034B 3
SR-6183 88V SC 3.7 1.5 LIHITORQUE 012-000-5 H
H IE21mHOV035A 10 10-300GL 80AD SC 1.0 2.2 LIllITORQUE Sf3-1-40 H
H D
1E21ml10V035B 10 10-300GL 80AD SC 1.0 2.2 LIltITORQUE stb-1-40 H
H IE21 MRV 092A
.75 502644 191 SC 1.5 1.3 H
b IE21 MRV 0920
.75 502644 191 SC 1.5 1.3 H
~
QUALIFICATICtl HILEST0t'ES tiOTES REVISI0tl 11 - JutlE 1983 V
A = REEVALUATION CottPLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 IH. ARE D = REQUEST FOR QUAL OR DID ISSUED FLOOR-Il0UtiTED (EllTP-9.5)
C :S/H RECOt::lEt;DATI0tl TO LILLO
- 2. * = DC tt0TCR. ALL OTHERS ARE At' V
D = QUAL DOC RECEIVED
- 3. CL 1 VALVES < OR = 1 Ill. tJtE E=lfARDHARE It0DIFICATIOtt REQ'D FLOOR-flOUtiTED ( EllTP-9.5)
F =CUAL DOC APVD & FILED
- 4. 2/1 = 2 IH. CLASS 1 G =SQRT PAPER col!PLETE
., V 11 = COPIES OF DOC TO DISTRIBtJTION V-
SHOREHLuJT 1 RBPH LIST STotlE & HEBSTER EtGL,t.lRING CORPORATI0tl RUN DATE 06/22/;3 JOB PM IE2 11600 1-50RT REACTOR DUILDItG CATEGORY I PIPE Il0UllTED EQUIPilENT RUN TIHE 09.C9.51 4
(
LILCO DOCHET S0-322 ACTIVE BOP QUALIFICATICH LEVEL (393 ITEMS)
PAGE 7 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 4
QUAL STATUS luRM PIPE QUAL.
SPEC LOC.
PU BER SIZE REPT 110.
HOR VER SUPPLIER HODEL 110.
YOHE OPER b
IE21 MRV 093A 1.5 502644 191 SC 1.5 1.3 H
IE21 MRV 093B 1.5 502644 191 SC 1.5 1.3 H
(
IE21 MRV 094A
.75 502444 191 SC 1.5 1.3 H
1E21 MRV 0968
.75 502444 191 SC 1.5 1.3 H
b IE32mHOV021A 1.5/1 SR-6704 253 SC 2.5 1.3 LIh! TORQUE SHC-04-5 H
H 1E32mHOV021B 1.5/1 SR-4706 253 SC 2.8 1.9 LIHITORQUE SilC-04-5 H
H b
1E32mHOV021C 1.5/1 SR-4706 253 SC 2.5 2.4 LIMITORQUE SHC-04-5 H
H 1E32mHOV0210 1.5/1 SR-4706 253 SC 2.4 1.5 LIHITORQUE SHC-04-5 H
H b
IE32mHOV022A 1.5/2 SR-4704 253 SC 2.3 1.5 LIllITORQUE SilC-04-3 H
H IE32mHOV0228 1.5/2 SR-6706 253 SC 2.0 1.7 LIHITORQUE StiC-04-3 H
H
(
IE32 mil 0V022C 1.5/2 SR-6706 253 SC 2.2 2.7 LIHITORQUE SilC-04-3 H
H 1E32mHOV022D 1.5/2 SR-4704 253 SC 2.4
.8 LIHITORQUE SHC-04-3 H
H l
b IE32mimV023A 1.5/2 SR-4706 253 SC 2.3
.7 LIHITORQUE SilC-04-3 H
H IE32mHOV0238 1.5/2 SR-6706 253 SC 2.3
.7 LIMITORQUE S!!C-04-3 H
H l
b IE32mHOV023C 1.5/2 SR-6706 253 SC 2.3
.7 LIllITORQUE SitC-04-3 H
H j
IE32mtl0V0230 1.5/2 SR-4706 253 SC 2.3
.7 LIHITCRQUE SitC-04-3 H
H l
(*
1E32mHOV024 2/2 SR-6188 253 SC 1.5 1.1 LIllITORQUE SIB-000-5 H
H i
1E32 mil 0V025 2/2 SR-6188 253 SC 2.3
.7 LIMITORQUE SilD-000-5 H
H i
l
(/
IE32mHOV024 2/2 SR-6188 253 SC 1.7 1.4 LIMITORQUE SIB-000-5 H
H QUALIFICATION HILESTot:ES tWTES REVISI0tl II - JUllE 1983 1
i D
A = REEVALUATION COtFLETE
- 1. CL 2 AfD 3 VALVES < OR n 2 IN. ARE i
B = REQUEST FOR QUt.L OR BID ISSUED FLOOR-il0UNTED (ENTP-9.5)
C =S/H REC 0lBIEt0ATION TO LILCO
D = QUAL 00C RECEIVED
- 3. CL 1 VALVES < OR = 1 Ill. ARE E=llAR0 HARE lt0DIFICATI0rl REQ'D FLOOR-HOUNTED (ENTP-9.5)
~
F = QUAL DOC APVD & FILED 4, 2/1 = 2 IN. CLASS 1 G =SQRT PAPER C0lFLETE L/
H = COPIES OF DOC TO DISTRIBUTI0tl I.
.g
(
/'
')
(
)
(V SIIOREH T1 RBPH LIST STONE & HEDSTER EttG2. m RING CORPORATI0tl RUN DATE 06/22/83 J00 NUtBE3 11100 1-SORT LEACTOR BUILDIffG CATECORY I PIPE ICUNTED EQUIPitEHT RUH TIHE 09.E9.51 7
A LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (393 ITEttSt PAGE 8 5
7 8
('
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS HARH PIPE QUAL SPEC LOC.
NUtBER SIZE REPT to.
tiCR VER SUPPLIER tt0 DEL 810.
YOHE OPER
(
IE32mHOV027 2/2 SR-6188 253 SC 2.3
.7 LIHITORQUE SitD-000-5 H
H 1E41mA0V081 1
10.3.115 318 SC 2.3
.7 COPES D-100-60 H
(
1E41mA0V082 1
10.3.115 318 SC 2.3
.7 COPES D-100-60 Il ll IE41mA0V083 1
10.3.115 318 SC 2.3
.7 COPES D-100-60 H
11 b
IE41mLCV-091 1
10.3.115 318 SC 2.3
.7 COPES D-100-60 H
H IE41mLCV095 1
10.3.115 318 SC 2.3
.7 COPES D-100-60 H
H
('
IE41mHOV031 16 SR-6266 88V SC 10.4 2.4 LIllITORQUE S10-0-25 m F
D 1E41mlCV032 16 SR-6266 88V SC 4.5 1.3 LIMITORQUE 010-0-25 m H
11
(.*
IE41alOV034 14 59-6267 80V SC 6.6 1.6 LIllITORQUE SID-2-60 m 11 H
IE41alOV035 14/1 14900-GT05 88AD SC 5.5 2.4 LIttITORQUE Sto-3-100 m II Il b
IE41stt0V034 4
SR-6068 88V SC 2.4 1.1 LIMITORQUE stb-00-10 m H
H IE41aHOV037 8
SR-6349 88V SC 1.8
.8 LIHITORQUE SHD-1-25 m it H
b IE41alIOV038 10 SR-6262 88V SC 2.8 1.2 LIllITORQUE StD-1-40 m 11 11 IE41mHOV039 2/2 SR-6188 253 SC 2.3
.7 LIHITORQUE stb-00-5
- H H
L 1E41mHOV041 10/1 SR-6259 88V PC 1.6 1.9 LIttITORQUE SID-3-80 H
H IE41mHOV042 10/1 SR-6264 80V SC 2.5
.9 LIMITORQUE stb-1-60
- H 11 b'
1E41mHOV043 10 SR-6262 08V SC 1.5
.5 LIMITORQUE Sim-1-60
- H H
IE41 alt 0V044 18 SR-6270 88V SC 4.4 4.5 LIMITORQUE S10-0-15
- H H
U IE41ml10V047 1/1 SR-6190 253 PC 2.3 2.4 LIMITORQUE SitD-000-2 H
H
~
QUALIFICATI0tl HILEST0tlES tl0TES REVISI0tt 11 - JUNE 1983 Las A = REEVALUATION COMPLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 Itl. ARE D = REQUEST FOR QUAL OR DID ISSUED FLOOR-ItOUNTED (EHTP-9.53 C =S/II REC 0titlElBATION TO LILCO
- 2. m = DC it0 TOR.
ALL OTilERS ARE AC
%/
0 = QUAL DOC RECEIVED
- 3. CL 1 VALVES < 09 = 1 Ill. ARE E=Ht.RDHARE Itu0IFICATI0tl REQ'D FLOOR-It0UtlTED (EttTP-9.51
~
F = QUAL DOC APVD & FILED
- 4. 2/1 = 2 Ill. CLAS3 1 G =SQRT PAPER C0ttPLETE
+
4./
H = COPIES OF 00C TO DISTRIDUTION
\\/.
m
)
S!!OREHAH'uY 1 RBPH LIST STONE & HEISTER EIGItt[E4IfG CORPORATI0tt I;tAl DATE 06/22/03 JOB HUtBE3 11600 1-SDRT REACTOR DUILDItG CATEGORY I PIPE 110UNTED EQUIPitEffT RUN TItfE 09.49.51
(
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tf LEVEL (393 ITElts)
PAGE 9
('
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS 5
7 8
HARM PIPE QUAL SPEC LOC.
IRJt0ER SIZE REPT 10.
HCR VER SUPPLIER If00EL to.
YOHE OPER
('
IE41mIIOV048 1/1 SR-6190 253 SC
- 1.3 2.6 LillITORQUE SIID-000-2m H
11 1E41mlOV049 2/2 SR-6188 253 SC 6.4
.3 LIlfITORQUE SIB-000-2m II H
(*
IE41mPCV142 2/2 2-24451 310 SC 2.3
.7 BECH 14-101-ES H
H IE41 MRV 145
.75 502644 191 SC 1.5 1.3 H
(,<
1E41 MRV 196 1.5 502644 191 SC 1.5 1.3 11 IE41 MRV 147 1.25 502644 191 SC 1.5 1.3 H
(,
IE41 MRV 149
.75 502644 191 SC 1.5 1.3 H
1E51mA0V081 1
10.3.115 318 SC 2.3
.7 COPES D-100-60 II H
(
IE51mA0V082 1
10.3.115 318 SC 2.3
.7 COPES D-100-60 H
ll 1E51mA0V083 1
10.3.115 310 SC 2.3
.7 COPES D-100-60 11 H
IE51mLCV091 1
10.3.115 318 SC 2.3
.7 COPES D-100-60 li ll IE51mLCV095 1
10.3.115 310 SC C.3
.7 COPES D-100-60 H
H IE51mlOV031 6
SR-6177 88V SC 5.7 1.6 LIMITORQUE SIB-00-5 m H
H IE51mIOV032 6
SR-6177 88V SC 6.0
.6 LIllITORGUE SID-00-5 m H
H
(
IE51m!!OV034 4
SR-6068 88V SC 1.2 1.7 LIllITORQUE SI!D-00-10 m H
H IE51mlDV035 6/1 SR-6574 88V SC 2.5 4.7 LIIIITORQUE S110-00-25 m H
H L
1E51mit0V036 2/0 SR-6198 253 SC
.9
.7 LIHITORQUE SID-000-5 m H
H IE51ml10V037 4
SR-6068 88V SC 1.2
.7 LIIIITORQUE SHD-00-10 m H
H I
Q*
IE51mHOV038 2/2 SR-6188 253 SC 1.3
.5 LIllITORQUE SID-000-5
- H H
~
QUALIFICATI0tl HILEST0HES lt0TES REVISI0tt 11 - JUNE 1983 A/
A =REEVALUATI0tl CultPLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 Irl. ARE B = REQUEST FOR CUAL CR DID ISSUED FLOOR-l!OUt(TED (EllTP-9.5 3 C =S/84 REC 0fttE!!DATION TO LILCO
- 3. CL 1 VALVES < OR = 1 Itt. ARE E=HARDHARE H001FICATION REQ'D FLOOR-Il0UtlTED (EllTP-9.5)
~~
i F = QUAL DOC APVO A FILED 4, 2/1 = 2 Itt. CLASS 1 G =SQRT PAPER CottPLETE
%p ll = COPIES OF DOC TO DISTRIBUTION k4
p\\
Ch
?
f SHOREH T1 RBPH LIST STONE & HE2 STER EllGIt ING CORPORATI0tl RtAl DATE 06/22/03 J0D HUlBE2 11600 1-SORT REACTOR BUILDIrlG CATELORY I PIPE HoutiTED EQUIPHENT RUtt TIllE 09.E9.51 h LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL 1393 ITEttSI PAGE 10 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS HARH PIPE QUAL SPEC LOC.
HUlBER SIZE REPT 10.
ISOR VER SUPPLIER ll0 DEL ID.
YOttE OPER
(.
IE51stDV041 3/1 SR-6060 88V PC 2.0 2.9 LIllITORQUE SHB-00-10 Il il IE51stDV042 3/1 SR-6060 00V SC 1.6 1.5 LIllITORQUE SID-00-7 1/2 H
11
(-
IE51stDV043 3
SR-6060 80V SC
.7
.3 LIHITORQUE SID-00-7 1/2 li 11 1E51mHOV045 8
SR-6078 88V SC 4.5 7.1 LIllITORQUE SID-000-5
- H H
(.,
1E51 mil 0V046 2/2 SR-6188 253 SC 2.3
.7 LIllITORQUE SID-000-2
- H H
IE51stt0V047 1/1 SR-6190 253 PC 1.6 8.0 LIllITORQUE Ste-000-2 H
H
(,-
IE51stt0V048 1/1 SR-6190 253 SC 1.1 1.9 LIllITORQUE SID-000-2
- F F
IE51stDV049 1.5/2 SR-6189 253 SC 2.6
.8 LIllITORQUE SID-000-2
- II H
(,)
1E51mPCV142 2/2 2-24451 310 SC 1.8
.8 BECH 14-101-DBQ H
H IE51 MRV 145
.75 502644 191 SC 1.5 1.3 II
(/
IE51 MRV 146
.75 502644 191 SC 2.6 1.6 11 IE51 MRV 147 1.25 502644 191 SC 1.5 1.3 H
(.e IE51 MRV 149
.75 502644 191 SC 1.5 1.3 H
IG11ml10V246 4
SR-6180 80V SC 4.3 2.7 LIHITORQUE SHD-000-5 H
H V
IG11 mil 0V247 4
SR-6100 80V SC 3.6 5.9 LIllITORQUE S10-000-5 ll H
1G11ml10V248 3
SR-6183 80V SC 1.7 1.3 LIllITORQUE stb-000-5 II H
V IG11st10V249 3
SR-6183 80V SC 2.5 1.1 LIllITORQUE SID-000-5 Il ll IG11mHOV639 3
SR-6477 80V SC
.9
.5 LIHITORQUE SID-000-5 H
H V
IG33 mil 0V030A 4/1 SR-6068 88V PC 3.6 1.9 LIllITORQUE SID-00-15 H
H QUALIFICATI0tl HILESTOtlES tDTES REVISIOtt 11 - JUNE 1903 V
A = REEVALUATION COMPLETE
C =S/H REC 0!DIEtDATION TO LILCO
- 2. * = OC tt0 TOR.
ALL OTHERS ARE AC V
D = QUAL 00C RECEIVED
- 3. CL 1 VALVES < OR = 1 Ill. ARE s
E=tlARollARE tt001FICATI0tl REQ'D FLOOR-Il0UllTED (EllTP-9.51 I
F = QUAL DOC APVD & FILED
- 4. 2/1 = 2 Ill. CLASS 1 G =SQRT PAPER CottPLETE V
ll = COPIES OF DOC TO DISTRIBUTI0tl s
s.
(
9T 1 SHOREHAt RBPH LIST ST0flE & HE"., STER ENG h RIllG CORPORATI0tt RUtt DATE 0(/22/83 JOB tlUt ER 11600 1-50RT CEACTOR DUILDING CATEGORY I PIPE HOUllTED EQUIPHENT RUN TIllE 09.49.51 I.
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL 1393 ITElis)
PAGE 11 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS HARH PIPE QUAL SPEC LOC.
HUttDER SIZE REPT tio.
IIOR VER SUPPLIER IODEL 10.
YOHE OPER i
('
IG33mtOV030B 4/1 SR-6068 88V PC 7.4 3.3 LIlfITORQUE SitD-00-15 II H
1G33mHOV031 6/1 SR-6181 88V PC 5.5 2.5 LIllITORQUE S110 4 0 H
H
(
1G33mlOV032 4/1 SR-6068 83V PC 6.5 1.4 LIllITORQUE S10-00-10 H
H IG33mHOV033 6/1 SR-6181 88V PC 8.0
.4 LIllITORQUE stb-00-25 H
H
(
IG33mHOV034 6/1 SR-6181 88V SC 4.6 2.4 LIllITORQUE SID-00-15
- H 11 IG33mHOV035 4
SR-6353 88V SC 1.9
.8 LIHITORQUE SitD-0-15 II H
(,, -
IG33 mil 0V036 4
SR-6353 88V SC
.9
.5 LIllITORQUE SID-0-15 II H
IG33mi10V037 4
SR-6353 88V SC
.7
.8 LIHITORQUE Ste-0-15 H
H
(/
1G33ml10V038 4
SR-6068 BBV SC
.7
.7 LIMITORQUE S10-00-15 11 ll IG33mt!OV037 4
SR-6068 88V SC
.6
.6 LIHITORQUE SHD-00-15 H
H
(*
1G33ml10V040 4
SR-6353 88V SC 1.3 1.1 LIMITORQUE SilD-0-15 H
H 1G33mHOV041 6/1 SR-6574 88V SC 5.1 3.9 LIllITORQUE SilD-1-25 H
II Q
IG33 MRV 093
.75 502644 191 SC 1.5 1.3 H
IG33 MRV 095A
.75 502644 191 SC 1.5 1.3 H
y 1G33 MRV 0958
.75 502644 191 SC 1.5 1.3 11 IG41ml10V032A 6
1891-1 203 SC 1.3 1.5 LIMITORQUE stb-00-10 H
H t.
1G41stt0V0320 6
1891-1 203 SC 1.1 1.0 LIMITORQUE stb-00-10 H
H IG41ml10V033A 6
SR-6177 88V SC 1.1 1.0 LIllITORQUE SilD-000-5 H
H
(
1G41mit0V0338 6
SR-6177 88V SC 1.2
.8 LIMITORQUE Sif8-000-5 H
ll QUALIFICATI0tl HILEST0fiES tl0TES REVISI0tt 11 - JUtlE 1983 V
A =REEVALUATI0tt CollPLETE
- 1. CL 2 AND 3 VALVES < OR = 2 IN. ARE B = REQUEST FOR QUAL OR BID ISSUED FLOOR-It0UNTED IElfTP-9.53 C =S/H RECollifEt0ATIOff TO LILCO
- 2. * = OC tl0 TOR.
ALL OTHERS ARE AC U
D = QUAL 00C RECEIVED
- 3. CL 1 VALVES < OR = 1 IH. ARE E=llAR0llARE I!ODIFICATI0tl REQ'D FLOOR-ItOUtiTED IEHTP-9.5)
I F = QUAL 00C APVD & FILED
- 4. 2/1 = 2 Ill. CLASS 1 G =SQRT PAPER C0tIPLETE V
ll = COPIES OF DOC TO DISTRIBUTIOH
~
k/
,f p
s' %
(
)
SIIOREli T1 RDPfl LIST STONE 1 HEUSTER ENrd IllG CORPORATION Rtki DATE 06/22/83 JOB tMIDE:2 1160) 1-50RT REACTOR CUIL*.IllG CATEGORY I PIPE l!OtRITED EQUIPitENT Pull TIltE 09.49.51
~
\\
LILCO DOCHET 50-322 ACTIVE DOP QUALIFICATIOtt LEVEL 1393 ITEHS)
PAGE 12 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS ItARN PIPE QUAL SPEC LOC.
HUllDER SIZE REPT 110.
Il0R VER SUPPLIER tt00EL tlO.
YOHE OPER
(
IG41ml0V034A 10 SR-6082 08V SC 4.9 1.1 LIltITCPQUE SID-0-7 1/2 II H
1G41mHOV0348 10 SR-4082 88V SC 1.8
.5 LIllITORQUE SilD-0-7 1/2 H
11
(..
1G41 MRV 019A 1
502644 191 SC 1.5 1.3 H
IG41 MRV 0198 1
502644 191 SC 1.5 1.3 H
('
IG41 MRV 024 1-S02644 191 SC 1.5 1.3 ll IG41 MRV 025 1
502644 191 SC 1.5 1.3 II b
IP41ml10V033A 20 D-0034-8 197 SC
.8
.7 LIHITORQUE H2DC/S100010 11 H
IP41ml10V033B 20 D-0034-8 197 SC
.9
.7 LIllITORQUE H2DC/ SIB 0010 ll H
(r IP41mit0V033C 20 D-0034-5 197 SC 1.0
.5 LIHITORQUE H20C/SitD0005 H
H IP41mHOV033D 20 D-0034-3 197 SC 1.1
.8 LIHITORQUE H2BC/ Sit 00005 H
H b
1P41m!OV034A 20 D-0034-6 197 SC
.6
.1 LIllITORQUE H2DC/SitD010 11 11 IP41mit0V0340 20 0-0034-0 197 SC
.1
.1 LIMITORQUE ll2DC/ Sit 3010 H
H b
IP41milOV037A 16 D-0034-2 197 SC
.5
.6 LIltITORQUE ll2DC/SIO005 11 H
IP41mit0V0370 16 D-0034-2 197 SC 1.0
.7 LIllITORQUE H2DC/SitD005 H
H L'
IP41ml10V039A 1/3 1891-1 203 SC 2.3
.7 LIMITORQUE stb-000-2 H
11 IP41stlOV039B 1/3 1891-1 203 SC 2.3
.7 LIllITORQUE SHD-000-2 H
H L
IP41mHOV042A 4
D-0034-9 197 SC 1.2 2.1 LIllITORQUE H0BC/SitB002 II H
IP41mit0V0420 6
D-0034-9 197 SC 1.0 1.1 LIllITORQUE H0CC/SitD002 11 H
(
IP41mHOV043 1/3 1891-1 203 SC 2.3
.7 LIltITORQUE SHD-000-2 H
H
<I L
QUALIFICATI0llitILESTONES 110TES REVISIOli 11 - JUllE 1983 L
A =REEVALUATI0tl C0tlPLETE
C =S/H RECollitEIDATIOtt TO LILCO
- 2. m = DC lt0 TOR.
ALL OTilERS ARE AC
(./
D = QUAL DOC RECEIVED
- 3. CL 1 VALVES < OR = 1 Ill. ARE Q
E:HAR0llARE It001FICATI0ll REQ'D FLOCR-HOUllTED IEllTP-9.5)
F = QUAL DOC APVD & FILED 4, 2/1 = 2 Ill. CLASS 1 G =SQQT PAPER C011PLETE l
o (e Il = COPIES OF DOC TO DISTRIDUTION
[
f%
()
)
N)
SHOREHAH Lat 1 RBPil LIST ST0ttE A HEBSTER ENGItlEE HG CCRPORATION rut! DATE 06/22/83 JOB HUl!DE2 11600 1-SORT REACTOR DUILCIllG Cf.TEGORY I PIPE It0UNTED EQUIPltEtiT RUN TIltE 09.r.9.51
(
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL 1393 ITEllSI PAGE 13 5
7 8
~
('
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS tlARM PIPE QUAL SPEC LOC.
tRJitDER SIZE R[PT tiO.
IICR VER SUPPLIER HODEL 810.
YOHE OPER
('
1P41st!OV102A 1/3 1891-1 203 SC 2.3
.7 LIIIITORQUE S10 000-2 H
H IP41alOV1028 1/3 1891-1 203 SC 2.3
.7 LIMITORQUE SI'B-000-2 H
H
('
IP41 mil 0V129A 10 15438 201 SC 1.2 1.2 LIllITORQUE H1BC/SilDC002 II H
IP41 mil 0V1298 10 15438 281 SC 1.1 1.3 LIMITORQUE HIBC/SitB0002 11 H
(.
IP41 MRV 024A 1
502644 191 SC 1.5 1.3 11 IP41 MRV 024A 1
502644 191 SC 1.5 1.3 H
b 1P41 MRV 0248 1
502644 191 SC 1.5 1.3 H
IP41 MRV 024B 1
502644 191 SC 1.5 1.3 H
(*
IP41 MRV 110A
.75 502644 191 SC 1.5 1.3 H
IP4thRV130A
.75 502644 191 SC 1.5 1.3 H
(*
IP41 MRV 110B
.75 502644 191 SC 1.5 1.3 11 IP41 MRV 1303
.75 502644 191 SC 1.5 1.3 H
(.,
IP41 MRV 119
.75 502644 191 SC 1.5 1.3 H
IP41 MRV 119
.75 502644 191 SC 1.5 1.3 Il L,
IP41 MRV 130A
.75 502644 191 SC 1.5 1.3 H
IP41 MRV 130A
.75 502644 191 SC 1.5 1.3 H
L>
IP41mPV1308
.75 502644 191 SC 1.5 1.3 11 IP41 MRV 1300
.75 502644 191 SC 1.5 1.3 H
U IP42mlOV031A 8
SR-6186 80V SC 1.1
.3 LIHITORQUE SIB-000-5 H
H i
~
QUALIFICATI0tl llILEST0l3ES IIOTES REVISIOtt 11 - JUrIE 1903
%./
A = REEVALUATION C0!!PLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 Ill. ARE B = REQUEST FOR QUAL OR BID ISSUED FLOCR-HOUTITED IElfTP-9.53 C =S/H REC 0tCIEf0AT10tl TO LILCO
- 2. m = DC it0 TOR.
ALL OTitERS ARE AC A./
D =CUAL 00C RECEIVED
- 3. CL 1 VALVES < CR = 1 Ill. ARE E=llARollARE It00IFICATI0tl REQ'D FLOOR-ilOUTITED ( EllTP-9.O F = QUAL 00C APVD & FILED
- 4. 2/1 = 2 Ill. CLASS 1 G =SQRT PAPER C0tlPLETE
(,,/
H : COPIES OF 00C TO DISTRIBUTI0ft L o
SHOREH e IIT 1 RDPH LIST STotaE & HESSTER EtErdERING CORPORATION RUH DATE 04/22/83 JOB Hut' E311400 1-SORT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPilEHT RlH TIHE 09.49.51 l
(
LILCD DOCHET 50-322 ACTIVE BOP QUALIFICATI0H LEVEL (393 ITEMS)
PAGE 14 5
T 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 4
QUAL STATUS HARH PIPE QUAL SPEC LOC.
' mR10ER SIZE REPT HO.
HOR VER SUPPLIER tt00EL NO.
YOHE OPER
(.
IP42 mil 0V031A 8
SR-4184 88V SC 1.1
.3 LIMITORQvE St e-000-5 H
H IP42mHOV0318 8
SR-4184 88V SC 1.2
.4 LIllITORQUE SHB-000-5 H
H i.
.IP42mHOV0318 8
SR-4184 88V SC 1.2
.4 LIllITORQUE Ste-000-5 N
H 1P42mHOV032A 8
SR-4184 88V SC 1.1 1.2 LIHITORQUE S18-000-5 H
H k.
IP42ml10V032A 8
SR-4184 88V SC 1.1 1.2 LIHITORQUE Ste-000-5 H
H IP42mHOV0428 14 SR-4265 88V SC 2.4 1.8 LIHITORQUE stb-0-25 it H
b IP42mHOV043A 8
SR-4184 88V SC
.8
.4 LIMITORQUE SilD-000-5 H
H IP42mHOV0438 8
SR-4184 88V SC 2.5
.4 LIHITORQUE stb-000-5 H
H b
IP42ml10V044A 8
SR-4184 88V SC 1.0
.5 LIllITORQUE stb-000-5 H
H a
i IP42 mil 0V0448 8
SR-4184 88V SC 2.0 1.0 LIllITORQUE Ste-000-5 H
H l
b IP42aHOV047 4
SR-4180 88V SC 3.7 4.2 LIllITORQUE Ste-000-5 H
H IP42mHOV048 4
SR-4180 88V SC 4.0 3.1 LIHITORQUE stb-000-5 H
H
(/
IP42 mil 0V147 4
SR-4180 88V PC 4.9 4.5 LIMITORQUE SIC-000-5 H
ll IP12mHOV148 4
SR-4100 88V PC 4.2 1.0 LIMITORQUE Ste-000-5 H
H L
IP42mHOV231 4
SR-4180 88V SC 1.2
.9 LIHITORQUE Sle-000-5 H
H j
IP42 mil 0V232 3
SR-4183 e8V SC 5.2 9.9 LIMITCRQUE SIB-000-5 II H
l
\\
IP42ml10V233 3
SR-4183 88V SC 5.9 7.4 LIHITORQUE SIB-000-5 H
H s
IP42mH0V234 3
SR-4183 66V SC 5.4 8.9 LIMITORQUE St B-000-5 H
H l
t IP42ml10V235 3
SR-4183 88V SC -
5.9 7.7 LIHITORQUE stb-000-5 H
H i
QUALIFICATION llILEST0llES tCTCS REVISIOil 11 - JUtlE 1983 j
L 4
4 =REFVALUATIott C0llPLETE'
- 1. CL 2 AND 3 VALVES < Ort = 2 IH. APE i
D =REWEST FOR QUAL OR BID ISSUE 0 FLOOR-HOUNTE3 IENTP-9.51 C =S/H REColulET DATI0tl TO LILCO
V D = QUAL DOC RECEIVED.
- 3. CL 1 VALVES < OR = 1 Itl. ARE i
ErittJtDilALE tlODIFICATION REQ'D FLOOR-HOUlfTED ([HTP-9.5)
F rQUAL 00C APVo & FILLD
- 4. 2/1 = 2 IH. CLASS 1 s
G c5QRT PAPER ColfPLETE
(/
H : COPIES OF DOC TO DISTRIDUTION i
'\\'
N ])
[
}
(
N.N Sil0REH IT 1 CDPH LIST STotlE & HEDSTER ENGI,wCItiG CORPORATIOH RUti DATE 06/22/83 JOB IIUlrE3 11'00 1-SORT
[EACTOR CUILDIllG CATEGORY I PIPE !!OUllTED EQUIPHEHT RU4 TIttE 09.C9.51
(
LILCO 00CHET 50-322 ACTIVE DOP QUALIFICATION LEVEL (393 ITEllS)
PAGE 15 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS IIARN PIPE QUAL SPEC LOC.
NUlIDER SIZE REPT t10.
HOR VER SUPPLIER HODEL 240.
YOHE OPER k.
IP42ml10V236 4
SR-6180 88V SC 6.0 3.3 LIMITORQUE SHD-000-5 H
H IP42mtl0V237 3
SR-6163 88V SC 5.4 2.4 LIttITORQUE SHD-000-5 H
H
(
IP42mit0V238 3
SR-6103 88V SC 7.3 2.4 LIHITORQUE stb-000-5 H
H IP42att0V239 3
SR-6183 83V SC 20.6 6.1 LIHITORQUE SitD-000-5 H
11
(
IP42mit0V200 3
SR-6183 OSV SC 1.8 1.7 LillITORQUE stb-000-5 II H
IP42mPCV071 4
10.3.115 310 SC 1.0
.6 COPES D-100-60 H
11
(.
IP42 MRV 079A 1
502644 191 SC 1.5 1.3 H
1P42 MRV 0790 1
502644 191 SC 1.5 1.3 H
k' IP4EmRV000A 1
502644 191 SC 1.5 1.3 11 IP42 MRV 0000 1
502644 191 SC 1.5 1.3 H
l IP42 MRV 080C 1
502644 191 SC 1.5 1.3 H
IP42 MRV 080D 1
502644 191 SC 1.5 1.3 ll
('
IP42 MRV 091A 1
502644 191 PC 6.9 3.0 H
IP42nRV0910 1
502644 191 PC 6.9 3.0 H
D IP42 MRV 291A
.75 502644 191 PC 6.9 3.0 ll IP42 MRV 291B
.75 502644 191 PC 6.9 3.0 ll O
IP42mTCV001H 12 CD76-82 423 SC 1.1 1.1 FISiiER 656-60 H
H IP42mTCV001X 10 CD76-82 423 SC
.9 2.3 FISifER 656-60 H
H A/
IP42mTCV001Y 12 CD76-82 423 SC 1.8
.4 FISHER 656-60 H
H
~
QUALIFICATI0ti HILEST0 ties NOTES REVISIOff 11 - JUtlE 1983
%/
A = REEVALUATION C0!!PLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 Ill. ARE D = REQUEST FOR QUAL OR DID ISSUED FLOOR-il0UtiTED (EllTP-9.5)
C = Sol REC 0tstEtIDATIOtt TO LILCO
- 2. m = DC lt0 TOR.
ALL OTHERS ARE AC V
D =CUAL DOC REEEIVED
- 3. CL 1 VALVES < OR = 1 Ill. ARE E=IIARDilARE tt001FICATION REQ'D FLOOR-ItOUilTED ( EllTP-9.5 3
~
F = QUAL 00C APVD & FILED
- 4. 2/1 = 2 Ill. CLASS 1 G =SQRT PAPER C0trLETE t
11 = COPIES OF 00C 10 DISTRIBUTI0tl (e
A1
\\
l
\\
)
Sil0REH REPil LISF STotiE & HE^STES ENG; It3 C0!!PORJ.TI0tt RtRI DATE 06/22/83
'~~'
JOB tRECE3 11600 1-50RT EEACTOR CUILDItiG CATEGORY I PIPE IIOUt4TED EQUIPitENT RUtt TIltE 09.C9.51
(
LILCO DOCICET S0-322 ACTIVE BGP QUALIFICATI0tl LEVEL 1393 ITEHS)
PAGE 16 5
7 0
1 2
3 4
OPER LOA 3-G'S OPERATOR 6
QUtJ. STATUS HARH PIPE QUAL SPEC LOC.
Ilut 0ER SIZE REPT 830.
It04 VLR SUPPLIER lt00EL fB.
YO:(E OPER IP42mTCV001Z 10 CD76-82 423 SC 1.9 2.0 FISilER 656-60 II H
IP50etIOV103A 1.5/2 SR-6189 214 SC 2.3
.7 LIllITORQUE stb-000-5 H
II
(
IPSGstCV1038 3.5/2 SR-6189 214 SC 2.3
.7 LIttITORQUE S!D-000-5 H
11 IP50m?t0V104 1
SR-4190 214 SC 2.3
.7 LIllITORQUE S10-000-2 H
H
(
IP50mfl0V105A
' 1.5/2 ~
53-6189 214 PC 2.3
.7 LIMITORQUE StO-000-5 H
11 IP50ml10VIO50 1.5/2 SR-6189 214 PC 2.3
.7 LIHITORQUE stb-000-5 H
ll IP50st:0V106 1
SR-6190 214 SC 2.3
.7 LIllITORQUE Sim-000-2 H
H IP50 mil 0V213A 1
S4-6189 214 SC 2.3
.7 LIllITORQUE Ste-000-5 H
11
(:
IPSn tt0V1136 1
UR-6189 214 SC 1.3
.7 LIIIITORQUE S10-000-5 II H
a r
IP5 hit 0V114A 1
SR-6189 214 SC 2.3
.7 LIttITORQUE Stu-000-5 H
ll l
IP50 alt 0V1140 1
SR-6189 214 SC 2.3
.7 LittIlor.QUE
$10-000-5 H
H IT23ptt0V031A
.5 SR-6341 214 SC 2.3
.7 LIllITORQUE SID-000-2 H
H
(
1T23ml10V0318
.5 SR-6341 214 SC-2.3
.7 LIttITORQUE SIB-0 00-2 11 H
IT23aRV021A
.75 502644 191 SC 1.5 1.3 H
t IT23aRV021B
.T5 502644 191 SC 1.5 1.3 H
1T2'4a A0V001 A 4
10.3.151 318 SC 6.8 3.6 COPES D-100-100 H
H L
IT2?aA0V0010 4
10.3.151 318 SC 2.9 3.7 COPES D-100-100 H
H IT24rA0V0044 4
10.3.151 318 SC 1.8 1.1 COPES D-100-100 H
H L-ITZ4mADV0048 4
10.3.151 318
'SC 3.0 2.0 COPES D-100-100 ll 11
~
QUALIFICATIOri Si!EEST0t:ES 840TES REVISI0tt 11 - JUTIE 1983
%s
~
A =REEVALUATI0tl C011PLETE
- 1. CL 2 Af D 3 VALVES < OR = 2 Ill. ARE B = REQUEST FOR QUAL OR DID ISSUED FLOOR-Il0UtiTED IEttTP-9.53 C =S/84 RLE0tDIEt0ATI0t1 TO LILCO
D =0UAL 00C RECEIVED
- 3. CL 1 VALVES < OR = 1 Ill. ARE E=llARDilARE tt001FICATIOil REQ'D FLOOR-liottiTED IEllTP-9.5 3 7
F = QUAL DOC APVD 1 FILLD
- 4. 2/1 = 2 Its. CLASS 1 G =SQRT PAPER CottPLETE gs 11 = COPIES OF DOC TO DISTRIBUTI0tl
%e
SHOREI L % IIT 1 RDPH LIST STot3 & llEDSTE3 ENGL2ERIllG CORPORATION RUN DATE 04/22/83 J00 flUI:1EJ 31400 1-50RT REACTOR BUILDING CATEGORY I PIPE IIOutlTED EQUIPHDIT Rutt TIllE 09.C9.51
(
LILCO DOCHET 50-322 ACTIVE BOP CUALIFICATION LEVEL 1393 ITDIS)
P/4E 17 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 4
QUAL STATUS HARM PIPE QUAL SPEC LOC.
lAABER SIZE REPT 810.
HOR VER SUPPLIER IIODEL 80.
Yol(E OPER
(
IT44mA0V0354 72 R-1042-41 111 SC 2.7
.6 BETTIS T-316 SR2-If3 H
H IT46mA0V0358 72 R-1062-41 111 SC 5.2
.6 BETTIS T-314 SR2-H3 H
H
(
1T44mAOV037A 72 CD75-35 111 SC 1.0
.7 BETTIS T-316 SR2-H3 H
H 1T44mA0V0378 72 CD75-35 111 SC
.8
.4 BETTIS T-316 SR2-H3 II H
(
1T44mA0V0384 18 4G403 172 PC 1.9 1.5 BETTIS 720C-SR-il3 H
H IT46mA0V0388 18 4G403 172 SC 1.3 1.3 BETTIS 722C-SR-il3 H
11
(
IT44mA0V038C 18 4G403 172 SC 1.9 1.5 BETTIS 722C-SR-H3 H
H IT44mA0V0300 18 4G403 172 SC 1.3 1.3 C:TTIS 722C-SR-H3 H
H 1T44mA0V039A 18 4G403 172 PC 1.9 1.5 BETTIS 722C-SR-10 H
H 1T44mA0V039B 18 4G403 172 SC 1.3 1.3 BETTIS 722C-SR-H3 H
H
(
IT44mA0V039C 18 4G403 172 SC 4.8 4.8 BETTIS 722C-SR-ll3 H
H IT46mA0V0390 18 4G403 172 SC 4.4 2.1 BETTIS 722C-SR-il3 H
H b
IT44mA0V078A 6
10.3.14F 318 PC 2.5 1.5 COPES D-100-100 H
Il IT46mA0V0700 4
10.3.145 318 SC 1.3
.4 COPES D-100-100 H
H O
IT46mA0V079A 4
10.3.151 318
.SC 3.9 1.8 COPES D-100-100 11 H
IT44mA0V0798 4
10.3.151 318 SC 5.2 2.0 COPES D-100-100 II H
O IT44mTCV-022A 4
2-24451 310 SC
.5
.3 BECH 14-103-ES H
H 1T46mTCV-0228 4
2-244F1 310 SC
.9 1.0 BECH 14-101-ES H
H tr IT46mTCV-0234 4
2-24451 310 SC 1.2
.2 BECH 14-101-ES H
H
~
QUALIFICATI0fl HILESTotiES NOTES REVISIDH 11 - JuliE 1903 V
A =REEVALUATI0tt COIPLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 IH. ARE B = REQUEST FOR QUAL OR BID ISSUED FLOOR-l!OUTITED IEllTP-9.5)
C =S/H RECO: CIEL 10ATIO!I TO LILCO
- 2. m = DC ll0 TOR.
ALL OTIIERS ARE AC v
D sQUAL DOC RECEIVED
- 3. CL 1 VALVES < OR = 1 IH. ARE E:HARDlL*,RE flCDIFICATinti REQ'D FLOOR-IIOutlTED IEllTP-9.5)
I F
- QUAL DOC APVD & FILED
- 4. 2/1 = 2 IN. CLASS 1 G =SQRT PAPER C0!IPLETE
(-
Il = COPIES OF DOC 10 DISTRIDUTION L>
x 8,
)
/
SHOREMAH L.if 1 WDPH LIST STutIE 1 NE*.STE2 EllGINEERING CORPORATICH RtM DATE SC/22/53 JOB taABE311'40 1-50RT REACTOR BUILCING CATEGORY I PIPE HOUtiT[D EQUIPHENT RUN TIllE 09.49.51 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0H LEVEL (393 ITEllS)
PAGE 18 5
7 8
A 1
2 3
4 OPER LOAD-G'S OPERATOR 4
QUAL STATUS HARH PIPE QUAL SPEC LOC.
DAA BER SIZE REPT
- 10.
H02 VER SUPPLIER I:COEL 80.
YOt(E OPER
(
IT44mTCV-0238 4
2 24451 310 SC 1.3
.8 BECH 14-101-ES H
H IT44mTCV-0244 4
2-24451 310 SC
.9
.4 CECH 14-101-ES H
H IT44mTCV-0248 4
2-24451 310 SC 1.0
.6 BECH 14-101-ES H
H 1T44mTCV-025A 4
2-24451 310 SC 1.2
.7 BECH 14-101-ES H
H
(.
IT44mTCV-0250 4
2-24451 310 SC
.4
.5 BECH 14-101-ES H
H IT4dmTCV-0264 4
2-24451 310 SC 1.1
.6 BECH 14-101-ES X
H L
1744mTCV-0268 4
2-24451 310 SC 1.0
.4 BECH 14-101-ES H
H IT44mTC'1-028A 2/3 2-24451 310 SC 2.3
.7 BECH 14-101-ES H
H b.
IT4dmTCV-0288 2/3 2-24451 310 SC 2.3
.7 BECH 14-101-ES H
H IT44mTCV059A 2/3 2-24451A 310 SC 1.0
.1 BECH 14-101-ES H
H D
1T44mTCV059B 2/3 2-24451A 310 SC 2.3
.7 BECH 14-101-ES H
H IT44mTCV040A 2/3 2-24451A 310 SC
.7
.7 BECH 14-101-ES H
H
(
1T44mTCV040B 2/3 2-24451A 310 SC 2.3
.7 BECH 14-101-ES H
H 1T47 MRV 037
.75 502644 191 PC 4.9 3.0 H
L'
- IT47 MRV 038
.75 502644 191 PC 4.9 3.0 H
IT48mHOV004 1
SR-4190 253 SC 2.3
.7 L11tITORQUE SIB-000-2 H
H
(,
IT48ml10V031A 4
SR-4177 88V PC 2.9 1.3 LIMITORQUE stb-00-5 H
H IT48ml10V0318 4
SR-4177 88V PC 4.1 1.8 LIMITORQUE stb-00-5 H
H U
IT48mHOV032A 4
SR-4177 80V PC 4.5 2.7 LIMITORQUE SIB-00-7 1/2 H
H
~
QUALIFIC ATI0td HILESTollES
- 10TES REVIS10tt 11 - JtXIE 1983
%t A = REEVALUATION CollPLETE
- 1. CL 2 Ate 3 VALVES < OR = 2 IH. ARE B = REQUEST FOR QUAL OR BID ISSttED C =S/H RECat3fEtOATION TO LILCO FLOOR-il0UNTED ( EllTP-9.5 3 i
- 2. * = PC HOTOR. ALL OTilERS ARE AC I
v D = QUAL 30C RECEIVED
- 3. CL 1 VALVES < OR = 1 IN. ARE
= i E:llARDHt.7E IICDIFICATION REQ'D FLOOR-Il0UNTED E EllTP-9.5)
F sQUAL DOC APVD & FIL[0
- 4. 2/1 = 2 Ill. CLASS 1
~,
G zSQRT PAPER COTE 3LETE j ' %,
H zCOPIES OF DOC TO DISTRIBUTION
(
SHOREllAH LAIIT 1 RBPH LIST STONE & HCSTER ETC.JItic CORPORATION RUM OLTE 04/F2/23
(,/
J00 PaulBER 31600 1-50RT CEACTOR CUILDIIG CATEGCRY I PIPE flout lTED EQUIPitEt(T Rt24 Tilt! 09.C.9.51
(
LILCO DOCHET 50-322 ACTIVE BOP QUALIFICSTICH LEVIL (393 ITEllSI PAGE 19 7
6 5
(
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS HARM PIPE QUAL SPEC LOC.
IAJOER SIZE REPT tD.
ItCR VER SUPPLIER llODEL NO.
YOHE OPER
(,
IT48alOV0328 6
SR-6177 88V PC 5.3 3.2 LItfITORQUE SID-00-7 1/2 H
H IT48alOV033A 6
SR-6177 08V SC 4.2 1.5 LIllITORQUE S!D-00-5 H
ll
(;
1T48att0V033B 6
SR-6177 80V SC 4.9 1.3 LIHITORQUE StD-00-5 II H
IT48alCV034A 6
SR-6177 88V SC 5.3 4.4 LIlfITORQUE 57B-00-7 2/2 It if
(-
1T48eHOV0348 6
SR-6177 80V SC 3.7 1.3 LIHITORQUE S!D-00-7 1/2 H
H IT48alOV035A 4
SR-6180 88V SC 4.2 2.8 LIttITORQUE S!10-000-5 H
H
(
IT40ml10V035D 4
SR-6180 88V SC 6.4
- s. 7 LIttITCPQUE S10-000-5 Il Il IT48mlOV037A 6
SR-6177 88V SC 4.7 5.8 LIttITORQUE S!D-00-7 1/2 Il il
(-
IT48all0V0378 6
SR-6177 80V SC 4.4 3.0 LIttITORQUE S10-00-7 1/2 H
ll IT48mit0V038A 4
SR-6180 88V SC 4.1 2.0 LIlfITORQUE StD-000-5 11 11
(
1T48at10V0388 4
SR-6180 88V SC 5.0 1.9 LIllITORQUE Sta-000-5 H
H IT48alOV040A 6
SR-6177 88V SC 8.6 5.9 LIttITORQUE StD-00-7 1/2 H
H b
IT48aHOV0400 6
SR-6177 80V SC 4.0 1.5 LIttITORQUE SID-00-7 1/2 H
ll IT48mit0V041 4
SR-6100 80V SC 1.3
.7 LIttITCRQUE SID-000-5 II H
v IT40mit0V042 4
SR-6100 88V SC 1.0 1.3 LIllITCRQUE S10-000-5 H
H IT40st0V043A 4
SR-6100 88V SC 2.9 2.5 LIlfITORQUE 510-000-5 11 H
(/
IT40stOV043B 4
SR-6180 80V SC 5.9 2.0 LIttITORQUE S!D-000-5 H
H IT40ml0V044A 4
SR-6100 80V SC 6.0 1.9 LIttITORQUE S'D-000-5 H
H U
IT40ml0V0448 4
SR-6180 00V SC 4.9 1.8 LIttITORQUE S!D-000-5 11 15 QUALIFICATI0tl llILESTOtlES tl0TES REVISI0tt 11 - JUi4E 1563
~
V
- 1. CL 2 AfD 3 VALVES < OR = 2 Itt. ARE A =REEVALUATIOtt col 5'LETE B = REQUEST FOR GUAL OR DID ISSUED TLOOR-It0UtiTED (EtITP-9.5)
C =S/il REC 0!!:tEllDATIOri TO LILCO
- 3. CL 1 VALVES < OR = 1 IH. ARE v
E=llARCHtdE It00IFICATIOtt REQ'D F LCGR-It0UtiT ED ( EllTP-9.5 )
~.
F =00AL DOC APVD & FILED
- 4. 2/1 = 2 Irl. CLASS 1 G : SORT PAPER C0!5'LETE ll = COPIES OF DOC TO DIEUIDUTI0tl v
O O
SHOREHAN L U RDPH LIST STONE & HE85TE3 EHGIttE k Z,CCRPORATIDH Rt#t DATE 84/22/83 JOB ltAGE3 11088 1-50RT REACTOR BUILS1HG Cf.TEGORY I PIPE HOUNTE3 EQUIPHEHT RtM TIHE 09.Q7.51
(
LILCO DOCHET 58-322 ACTIVE 80P QUALIFICATION LEVEL 1393 ITEHSI PAGE 28 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 4
QUAL STATilS
/
HARH PIPE QUAL SPEC LOC.
NABER SIZE REPT HD.
HOR VER SUPPLIER H00EL 110.
YONE OPER
' A 1T48ePCV1434
.25 QTR-745 492 SC 1.5 1.3 H
)
IT48ePCV1438
.25 QTR-745 492 SC 1.5 1.3 H
t IT48ePCV143C
.25 GTR-745 492 SC 1.5 1.3 H
)
1T48ePCV1430
.25 QTR-745 492 SC 1.5 1.3 H
(
IT48ePCV144A
.25 QTR-745 492 SC 1.5 1.3 H
1T48ePCV1448
.25 GTR-745 492 SC 1.5 1.3 H
(
IT48ePCV145A
.25 QTR-745 492 SC 1.5 1.3 H
IT48ePCV1958
.25 QTR-745 492 SC 1.5 1.3 H
(*
IT48ePCV195C
.25 QTR-745 492 SC 1.5 1.3 H
)
ITC8ePCV1450
.25 QTR-745 492 SC 1.5 1.3 H
ITC8ePCV1444
.25 QTR-745 492 SC 1.5 1.3 H
IT48ePCV1468
.25 QTR-745 492 SC 1.5 1.3 H
(*
1TC8eRV017A 3
502444 191 SC 1.9
.7 H
IT*8eRV0178 3
502444 191 SC 3.7 3.1 H
(-
IT;8eSOV124A
.75 NtS245463271 400 SC 1.5 1.3 H
1T 8eSOV1248
.75 MI5245483271 400 SC 1.5 1.3 H
L IT48eSOV12TA
.75 MI5245483271 400 SC 1.5 1.3 H
IT48eSOV1278
.75 BR5245483271 400 SC 1.5 1.3 H
~
(
IT;8eSOV128A
.75 BR5265463271 400 SC 1.5 1.3 H
'/t z
QUALIFICATI0H HILEST0tlES NOTES REVISIGH 11 - JUNE 1983
%/
s/
A zREEVALUATION C0tPLETE
- 1. CL 2 Arm 3 VALVES < OR = 2 IH. ARE B 3 REQUEST Fort QUAL OR BIO ISSUEO FLOOR-fl0LNfTED (DITP-9.5)
C zS/H REcottlENDATI0tt TO LILCO
- 2. e = DC fl0 TOR.
ALL OTilERS ARE AC i
gs D = QUAL DOC RECEIVED
- 3. CL 1 VALVES < OR = 1 Itt. ARE V'
E=HARDHr.RE H001FICATI0tl REQ'D FLOOR-l!OutiTED E Df1P-9.5 3
~
F zGUAL 00C APVD & FILED
- 4. 2/1 z 2 IN. CLASS 1 G zSQRT PAPER C0lFLETE H 3 COPIES OF 00C TO DISTRIBUTICH r)
I p,.
y
/
)
I v
/
i,"/
SHOREHAH Ci l 1 REPH LIST STONE & HE':,STD EIGTHEE 10 CORPODATI0tl RtAl DATE 06/22/83 JOB HulE O 11:00 1-50RT CEACTOR CUILDItG COTEGORY I PIPE HOUNTO EQUIPtXHT RtXI TIllE 09.r9.51 I
,(
LILCO DGCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL (393 ITEltSI PAGE 21 5
7 8
(
1 2
3 4
OPER LOAD-G'S OPERATOR 6
QUAL STATUS PARM PIPE QUA L SPEC LOC.
BR.A CER SIZE REPT 80.
HOR VER SUPPLIER IODEL to.
YG(E OPER
(
IT48eSOV1288
.75 Im5265683271 600 SC 1.5 1.3 H
IT40sSOV129A
.75 ID5265683271 600 SC 1.5 1.3 H
(
IT48aSOV1298
.75 IN5265683271 600 SC 1.5 1.3 H
IT48aSOV130
.75 IR5265683271 600 SC 1.5 1.3 H
(
1T48aSOV131
.75 HR5265683271,
600 SC 1.5 1.3 H
IT48eSOV136A
.75 tR5265683271 600 SC 1.5 1.3 H
(
IT48mSOV1368
.75 HR5265683271 400 SC 1.5 1.3 H
IT48eSOV137A
.75 IR5265653271 600 SC 1.5 1.3 H
(
IT48sSOV1378
.75 HRS 265683271 600 SC 1.5 1.3 Il IZ93aFCV011A
.25 17759-83N 493 SC 1.5 1.3 H
(
1Z93eFCV0118
.25 17759-83tl 493 SC 1.5 1.3 H
1Z93mPCV010A
.25 QTR-745 492 SC 1.5 1.3 H
(,
IZ93.PCV010D
.25 QTR-745 492 SC 1.5 1.3 H
4.'
V U
GUALIFICAT10tl 111LEST0t4ES IOTES PEVIS10tl 11 - JLAIE 1983 U
A zREEVALUATIOtt C011PLETE
- 1. CL 2 AfD 3 VALVES < OR = 2 Irl. ARE B = REQUEST FOR QUAL OR DID ISSUED FLOOR-it0UtiTED (EllTP-9.5)
C :S/ll RECCIEtttOATIQI TO LILCO
- 2. e = DC fl0 TOR.
ALL OT18ERS ARE AC g,/
D zQUAL DOC RECEIVED
- 3. CL 1 VALVES < GR = 1 Ill. ARE E=11AR084ARE 110DIFICATIOtt REQ'D FLOOR-110UtliED I EllTP-9.5)
~.
F =GUAL DOC APVD & FILED
- 4. 2/1 = 2 IN. CLASS 1 G =SQRT PAPER CutlPLETE A/
11 zCOPIES OF DCC TO DISTRIBUTION
SHopfHMt L._,
1 GE LIST STONE & HECSTER Ef4GINEth.a CORPORATION JOB HulsE3 11400 1-50RT GEtECAL ELECTRIC CATEGORY Z EQUIPIEllT '
RtM D*.TE 04/22/03 RUN TIHE 13.51.22
(.
LILCO DOCHET 50-322 ACTIVE HSSS QUALIFICATION LEVELt150 ITDIS)
PAGE 1 HaltK EQUIPtENT GE BLOG AVAIL QUAL QUAL TYPE SAFETY QUAL ttASER DESCRIPTICH NO.
VEte0R ELEV IllSP REPT HETH FREtt HTNG FUNC STATUS 1821mAOV001 ISOLATION VALVE-HS B21F022 ROCHMELL SC082 YES NEDE-24122-2 SA 8
P4 C3.HS F
1821mA0V082 -
ISOLATION VALVE-NS B21F028 ROCHMELL SC082 YES NEDE-24122-2 SA 8
P4 CS.HS F
1821mO-003 C0teENSING OlalBER B21D002 GE SC080 YES DRF-A00794-11 SA 40+
P HS.CS F
1 21mL-004 COPGENSING CHAleERS B21D004 GE SC080 YES DRF-A00794-11 SA 40+
P2 HS.CS F
P14 HS.CS F
II21mPDS02A1 DAIPENER E21H004A SHIP LOOSE F
B 1821mPDS0281 DAFFEHER 821N007A SHIP LOOSE F
B 1021mPOS02C1 DAIFENER B21H0084 SitIP LOOSE F
B 1B21mPD50201 DAIFEtER B21H009A SHIP LOOSE F
B 1 21mPS 020 PRESSWE SHITCH B21N015 BARHSDALE CB037 YES DRF-A001084215E SAT 33+
F4 C3.HS F
- (,,
I 1021 MRV 092 RELIEF VALVE B21F013 TARG ROCH PC099 YES VPF-5405-3-1 IST' 40+
P11 CS G
I 1821mTI 003 TEIPERATLRE ELEHENT B21N040 ROSEHotRIT T084 YES DRF-A00-01344 SA 100 P
CS.HS F
1121mTE 043X TEDFERATURE ELEIENT B21H014 PYCO T959 YES DRF-AOO-108491C SAT' 40+
F4 CS.HS F
II21mTE 093Y TEtFERATURE ELEHENT 821N010 PYC0 T082 YES DRF-A00-108491C SAT 40+
F4 CS.IIS F
l U
II21mTE 059 TEIFERATURE ELEHEt'T B21t014 PVC0 T059 YES DRF-A00-108491C SAT 40+
F4 CS.HS F
i 1831mHOV031 RECIFC SUCTION VALVE B31F023 ANCHOR SC017 YES 385HA441 SA 41 PZ H
G lD i
l IE31eHOV032 RECIRC DISCHARGE VALVE B31F031 ANCHOR SC014 YES VPF2809-40 SA/DA 100 P2 H
F i
1331mP- 001 RECIRC PUlr & HOTOR B31C001 BJ/GE PC070 YES 204833C001-HS-1 SA 40+
P2 N
G
(#
4 s
1231mTE 025 TEtFERATLME ELEHENT B31H023 ROSEHOL2fT PC045 YES DRF-A00-01344 SA 100 P2 N
F
,V CQ =CC#iTROL BLDG P : PIPE HotMTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 11 - JUNE 1983 j
_CS zCOLD SifUT Dol #1 PC =PRIHARY CollT.
BIAXIAL TESTIrlG A mREEVALUATIOtt C0tFLETE 04 :DYNAlllC AttALYSIS PL : PEDESTAL SC =SEC0t1DARY C0tW.
B mREQUEST FOR REQUAL OR BIO ISSUED NOTEt Null 6FR IN F = FLOOR 190UNTED QP = QUALIFIED BY
/ zLOCATED ON CONT.
C =S/H REC 0tOIEteATION TOLILCO
' TYPE HitG' COLutM IS V HS zHOT STAtOBY PIPIti3 AtlALYSIS HALL D = QUAL DOC RECEIV[D QUANTITY OF ITEllS.
i
~
110T lIULTI-FREQUENCY RH mRADllASTE T allAIll STH. tut 01EL E =HARDHAPE HODIFICATION REQ'O BIAXIAL TESTIt1G SA = STATIC AtiALYSIS N =HEI71ER CS OR llS F = QUAL DOC APVD & FILED l
HST=HULTI-FREQUEllCY SATsSIIIGLE FREQUEtlCY G =SQRT PAPER C0!PLETE Le SINGLE AXIAL TESTING Sit 4GLE AXIAL TESTING H COPIES OF 90C TO DISTRIBUTION i-(e l
%d,
p
(-y BIT 1
\\
(
)
\\
)
\\
/
SilOREH GE LIST ST0ttE 1 HECSTE2 EtGI:_JG CORPORATIDH RtFt DATE 06/22/83 JOB tiUtIBE2 11'00 1-SORT GEllE"AL ELECTIIC CATEGCSY I EQUIPitEtiT RUN TIllE 13.51.22 LILCO DOCHET 50-322 ACTIVE tiSSS QUALIFICATI0tt LEVELt150 ITEtts)
PAGE 2 ftARR EQU1PHEtiT GE BLOG AVAIL QUAL QUAL TYPE SAFETY QUAL IRJ10ER DESCRIPTICH NO.
vet 00R ELEV ITISP REPT ffETH FREQ HTIG FLRIC STATUS A
1C11mA0V050 SOV ADV C11-F180 SHI? LOOSE P
B IC11eADV051 50V ADV C11-F181 SilIP LOOSE P
B l
IC11sA0V081 IICU DIAPHRAGH VALVE C11F010 60 01 SC078 YES SA P
CS.HS B
l IC11rA0V082 HCU DIAPHRAGat VALVE C11F311 M0l SC040 YES SA P
CS.HS B
(
IC11aHCU-01 CRD HYDRA CONT UllIT C110001 GE SC078 YES 303HA853 ItST 2
137 CS.Its G
ICIImLS 049 LEVEL SHITCH C11tiO13 HAGNETROL SC078 YES 43235-1 ICT 30+
F2 CS.HS B
IC11mLS 095 LEVEL SHITOl C11tiO13 HAGNETROL SC078 YES 43235-1 HDT 30+
F6 CS.HS F
IC11mLT 049 LEVEL XIIIR C11H012 GOULO SC078 YES SHI@ LOOSE 11 F4 8
1C11ePT 113 PRESS XHTR C11tt052 ROSEtIOlRfT SC063 YES SifIP LOOSE 50 F
B IC11aSOV044 IICU SOLEHOID VALVE C11F009 ASCO SC063 P
CS.HS B
L IC11mSOV052 SDV SOLEt40ID VALVE C11F182 ASCO P
B IC41mEV 010 EXPLOSIVE VALVE C41F004 COHAX SC112 YES VPF3374-36-2 SDT 35+
P2 H
G IC41aP-024 STDBY LIQ PutPIIITR C41C001 LNICH PLM SC113 YES VPF-5517-2-2 SDT 60+
F2 t1 G
IC41 API 002 PRESSURE It0ICATOR C41R003 RODT SHAH SC112 YES DRF-A000184160D S3T 100 F
C5.HS F
D i
IC41.PT 002 PRESSURE TRAlist!ITTER C41H004 ROSEt10UNT SC112 YES DRF-A00-1081101 SAT 50 F
CS.HS F
3C41mTH-003 SLC STORAGE TATH C41A001 LAICO SC113 YES RAS 4UC41-22 SA 59 F
tt G
V IC41sTH-150 SLC ACCUllLA.ATORS C41A003 HYDRA C0ft SC097 YES DRF C41-22 SA WA PZ tl G
IC41mT5001A TEIP SHITCil C41H003 HEED IttST SC112 DRF-A00-01364 SA 60+
F CS.HS F
V IC51mTIP-004 TIP VALVE CUIDE T C51J004 GE SC073 YES DRF-A00992-H SAT 100 F4 14 D
L CD =C0tiTROL CLDG P = PIPE HoutiTED SBT=SIflGLE FREQUEtiCY QUALIFICATI0tl HILEST0t(ES REVISION 11 - JUNE 1963
_CS = COLD SHUT DOHtt PC =PRIttARY COHT.
DIAXIAL TESTItt3 A =REEVM.UATI0tt C0!!PLETE DA =0Yt4AtlIC AtlALYSIS PL : PEDESTAL SC =SEC0f 0ARY CONT.
B = REQUEST FOR REQUAL OR BID ISSUED t10TE: flut:CER IN F = FLOOR tt0UtiTED QP = QUALIFIED BY
/ = LOCATED OH C0!IT.
C =S/H PEC0!RtEFOATIOtt TOLILCO
' TYPE flitG' COLutti IS V HS = HOT STAT:DDY PIPI!G AtlALYSIS HALL D = QUAL DOC RECEIVED QUAtiTITY OF ITEttS.
ICT=lfulTI-FREQUEtlCY RH =RADliASTE Y titAIN STif. RRRIEL E =HAN: Hit.RE tt00IFICATICH REQ'D BIAXIAL TESTItG SA = STATIC AttALYSIS H =t4EITHER CS OR HS F = QUAL 00C APVD & FILED ttST=l!ULTI-FREQUEllCY SAT = sit 4GLE FREQUEtiCY G =SQRT PAPER CollPLETE V
SINGLE AXIAL TESTItG sit 4GLE AXIAL TESTItG 11 = COPIES OF DOC TO DISTRIBUTION I
v V.
,q
(
)
l Sil0REli 1
GE LIST STONE 1 HE~ STER EfGINE J CORPCRATI0tt RtR4 DATE 06/22/;3 V'
JOB #1Utm U 11600 1-SORT GEllE~AL ELECTRIC CATEGORY I EQUIPlttfiT RUH TIltE 13.51.22 2
k LILCO DOCHET 50-322 ACTIVE tGSS QUALIFICATI0tl LEVEL (150 ITEIG)
PAGE 3 llARH EQUIPitErfT GC BLDG AVAIL QUAL QUAL TYPE SAFETY QUAL tRAIDER DESCRIPTICH B10.
VEtOOR ELEV ItGP REPT llETH FREQ lilNG FUt1C STATUS 1C61mFT 001 DIFF PRESS XHTR C61tiO01 ROSEll0UrfT SC00S YES DRF-A00-1084101 SAT 50 F
H F
IC61= Pit-RSP REHOTE SitT DN PtL C61P001 GE SC063 YES SAI-0290A80PA-B HDT 14 F
H D
IC61mPT 006 PRESS TRA?G C61H006 BAILEY SC079 YES DRF-A001084162C SAT 100 F
H F
IC71mPS 003 PRESSURE SHITCH C71N003 BARHSDALE CB037 YES DRF-A001084215E SAT 33+
F4 CS.HS F
1E11mE-034 RHR HEAT EXCHAtlGERS E110001 PERFEX CP SC008 YES DRF E11-1 DA 14 F2 IIS.CS G
1[11 EFT 004 DIFF PRESS XitTR E11tiO13 ROSEll0UNT SC078 YES DRFA00-1084-101 SAT 50 F
CS ells F
IE11mFT 006 DIFF PRESS TRAttS E11N007 ROSDt0UNT SC008 YES DRFA00-1084-101 SAT 50 F2 CS.HS F
IE11mLT 002 LEVEL XHTR E11tt008 BARTON SCO24 YES DRFA00-1084-67E IDT 100 F2 CS.HS F
(.
1E11mP-014 RitR PUtPS SIIOTORS E11C002 BJ/CE SC008 YES DRF E11-11 DA 10 F4 CS.HS G
IE11mPS 134 PRE 3SURE SHITCH E11N016 BARHSDALE SC008 YES DRFA00-1084215E SAT 33+
F4 CS ells F
1E11aPS 135 PRESSURE SHITCH E11H020 BARHSOALE SC008 YES DRFA00-1084215E SAT 33+
F4 CS.HS F
IE11mTE 014 TEIP ELEHEtiT E11tt009 PYC0 SC023 YES DRFA00-108991C SAT 60+
FZ CS.HS F
t.
IE11mTE 015 TEIP ELEHENT E11N030 PYC0 SC023 YES DRFA00-108491C SAT 60+
F2 CS.ItS F
1E21mP-013 CS PUIPS & 190 TORS E21C001 BJ/GE SC008 YES DRF E21-53 DA 12 F2 CS G
A 1E21mPISO98 PRESS It0IC SHITCH E21H010 ROBT SHAH SC008 YES DRFA00-1084215E SAT 33+
F2 CS.HS G
IE21mPS 012 PRESSURE SHITCH E21H008 BARHSDALE SC008 YES DRFA00-184-141 SAT 33+
F2 CS.lis G
V IE21mPS013 PRESSURE SHITCil E21tiOO9 BARHSDALE SC008 YES DRFA00-184-141 SAT 33+
F2 CS.Ils G
1E32mBLO-13 OUTDD llSIV LCS BLOHER E32C002 GE SC076 YES VPF3830-14-1 SBT 60+
F2 H
G V
IE32mDLO-14 IttDD itSIV LCS BLOllER E32C001 GE SC076 YES VPF3830-14-1 SBT 60+
F H
G V CB =C0tlTROL BLDG P = PIPE 110UNTED SBT=SIrlGLE FREQUEllCY QUALIFICATION llILESTONES REVISI0tt 11 - JUllE 1983 CS = COLD SHUT D0l84 PC =PRIttARY C0 tit.
DIAXIAL TESTING A =REEVALUATIOtt C0!PLETE
~
DA =DYllAttIC AtlALYSIS PL = PEDESTAL SC =SEC0tlDARY Cotif.
B = REQUEST FOR REQUAL OR BID ISSUED
!!OTE: 11UttCER IN F = FLOOR ll0UtlTED QP = QUALIFIED BY
/ = LOCATED Oil C0 tit.
C =S/H REC 0!DIEf1DATIOff TOLILCO
' TYPE flTilG' COLUllH IS V HS = HOT STAliDBY PIPIrlG AtlALYSIS HALL D =00AL DOC RECEIVED QUAtITITY OF ITEllS.
HDT=lIULTI-F R EQUEtiCY RH =PACllASTE T =ttAlti STH. TUtRIEL E = lit.ROHARE It0DIFICATION REQ'D BIAXIAL TESTING SA = STATIC AtlALYSIS H =NEITHER CS OR HS F = QUAL DOC APVD & FILED HST=lfULTI-FREQUEllCY SAT = sit;GLE FREQUEf 3CY G mSCRT PAPER COIPLETE V
SIllGLE AXIAL TESTIrlG SIllGLE AXIAL TESTIttG H = COPIES OF DOC TO DISTRIDUTI0ft I
. v V.
SHORENAH C d 1 SE LIST ST0taE & HELSTER ENGINEERING CORPORATICH RUN DATE 06/22/83 JOB I4Ut2E2 11600 1-50RT GENERAL ELECTRIC CATEGORY I EQUIPHENT RW4 TIllE 13.51.22
\\
' LILCO 00CHET S0-322 ACTIVE f4555 QUALIFICATION LEVEL (150 ITEllS)
PAGE 4 HARN EQUIPHENT GE BLOG AVAIL QUAL QUAL TYPE SAFETY QUAL i
PAAGER DESCRIPTION NO.
VDOOR ELEV IttSP -
REPT ttETH FREQ HTrG FutaC STATUS 1E32sFE037 FLOH HETER E32t4006
$1H SC066 YES DRFA00-1084150C SAT 30+
P4 CS.HS F
1E32eHC-053 H5IV LCS NTR E320001 CE SC078 YES VPF3830-33-1 IST 15 P4 H
G IE32mPDT035 DIFF PRESS TRAttS E32N059 ROSEHOLMT SC063 YES DRFA00-1004-101 SAT 50 F
CS.HS F
ILJ2mPDT038 DIFF PRESS TRAttS E32t4054 ROSEHOWIT SO F
B IE32ePT 033 GAGE PRESS TRAttS E32tl055 ROSENOLRIT SC063 YES DRFA00-1084-101 SAT 50 F
CS.HS F
1E32mPT 034 ABS PRESS TRANS E32N056 ROSEHOUNT SC063 YES DRFA00-1084-101 SAT 50 F
CS.HS F
k IE841mLS091 LEVEL SHITCH E41N014 HAGt4ETROL SC016 YES 43235-1 fBT 30+
F CS ells F
1E41eL5092 LEVEL SHITCH E41N015 HAGNETROL SC027 YES 43235-1 IST 30+
F2 CS.HS F
4 l
1E01sL50934 LEVEL SHITCH E41tt002 HAGNETROL YARD YES 43235-1 IST 3O+
F CS.HS F
IEt1mLSO938 LEVEL SHITCH E41N003 HAGtIETROL YARD YES 43235-1 HBT 30+
F CS.HS F
1E41mP-016 HPCI PtRP& BOOSTER E41C001 PACIFIC P SC008 YES VPF-2740-180-1 DA 23 F
H G
1E41mTE053 TEIPERATURE ELDiENT E41N024 PYCO SC034 YES DRFA00-1084-91C SAT 60+
F2 CS.HS F
1E41mTE054 TEtPERATURE ELEMENT E41N028 PYC0 SC025 YES DRFA00-1084-91C SAT 60+
F2 CS.llS F
IE41mTE055 TEIPERATURE ELEMENT E41N029 PYCO SC017 YES DRFA00-1084-91C SAT 60+
F2 CS.HS F
t:
f 1E41mTE056 TEIPERATURE ELDIENT E41N030 PYC0 SC043 YES DRFA00-1084-91C SAT 60+
F2 CS.HS F
IE41mTI141 TDP IPOICATOR E41R002 NEED SC008 YES DRFA00-01364 SA 100 P
CS.HS F
L 1EralmTU-002 HPCI TURBIttE E41C002 TERRY SC008 YES IST F
N 8
4 1E51mL5091 LEVEL SHITCH E51N010 HAGNETROL SC008 YES 43235-1 IST 30+
F CS.HS F
V IE51mP-015 RCIC PUIP E51C001 BINGIIAH SC008 YES DRF E51C00112 SA 24 F
HS G
V. CS =C0ftTROL BLDG P :. PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISI0tl 11 - JUNE 1983
_CS = COLD SilUT DolN PC PRIllARY CONT.
BIAXIAL TESTIrlG A = REEVALUATION C0f1PLETE DA =DYNAllIC AtlALYSIS PL = PEDESTAL SC =SECO'DARY COIIT.
8 = REQUEST FOR REQUAL OR BID ISSUED f30TE: ilU!IBER Irl F = FLOOR 190UllTED QP = QUALIFIED BY
/ = LOCATED ON Corn.
C =S/H REC 0t91EtIDATIOtt TOLILCO
' TYPE HTliG' COLUlH IS Ae HS = HOT STAttDSY PIPING AtlALYSIS HALL D = QUAL DOC RECEIVED QUANTITY OF ITEttS.
IIDT=ltVLTI-FREQUENCY RH =PADilASTE T =llAIN STil. TUtRIEL E =HARDHARE IICDIFICATION REQ'D BIAXIAL TESTIf;G SA = STATIC ANALYSIS H =tIEITHER CS OR HS F = QUAL DOC APVD & FILED HST=lIULTI-FREQUEllCY SAT =SItt0LE FREGUEllCY G =SQRT PAPER C0tPLETE O
SIIIGLE AXIAL TESTIllG SItGLE AXIAL TESTING H =COPIFS OF DOC TO DISTRIBUTION 7.
4 p.
e
. i k.
~ /
d I
SHOREHAM 19 FIT 1 EE LIST STONE & HEBSTE2 EtEINEE".nING CORFORATION Rtst DATE 04/22/8'l l
JOB HLAZER 11600 1-50RT CENERAL ELECTRIC CATEGORY I EQUIPilENT RUN TItIE 13.51.22
' (
LILCO DOCHET 50-322 ACTIVE HSSS QUALIFICATION LEVELt150 ITEMS)
PAGE 5
' HARM
. EQUIPflEffT -
GE BLOG AVAIL QUAL QUAL' TYPE SAFETY QUAL tAABER DESCRIPTION PE.
VEtGOR ELEV INSP REPT HETH FREQ HTNG FliHC STATUS 1E51mTE052 TEtFERATURE ELEHENT E51H011 PVC0 SCO25 YES ORFA00-1084-91C SAT 40+
F2 CS.HS F
i-1E51mTE053 TEFFERATURE ELEHENT E51H022 PYC0 SC027 YES DRFA00-1084-91C SAT 40+
F2 CSellS F
g 1E51mTE054 TEIFERATURE ELEHENT E51N023 PYC0 SC043 YES DRFA00-1084-91C SAT 40+
F2 CS.HS F
1E51mTE055 TEDFERATURE ELEHENT E51H025 PVC0 SC064 YES DRFA00-1084-91C SAT 60+
F4 CS eltS F
1E51mTE054
- TEtFERAT1RE ELEHENT E51N024 PYCO SC064 YES DRFA00-1084-91C SAT 40+
F4 CS.HS F
1E51mTI141 THERH0 HETER E51R005 ROST SHAM SC006 YES DRFA00-01364 SA 100 P
CS ells F
1E51mTU-005 RCIC TLRBINE E51C002 TERRY SC006 YES VPF3622-79813-2 SA/imi 15 F
HS F
IF11mTO-005 FUEL PREP HACHINE F11E001 GE SC176 YES DRF F0000002-3 DA WA F2 H
G 1F11mTO-006 GEN PURPOSE GRAPPLE F11E011 GE SC176 YES DRF139F11E011L SA WA F3 H
G 1F13mSL-001 DRYER &SEP slits F13E006 CAL PAC SC176 YES DRF F13-9 SA WA F
!4 F
1F13mTO-014 HEAD STRONGBACH F13E009 LAHC0 SC174 YES DRF F13-11 SA WA F
H F
1F14mTO-029 CONT RCD GRtJ8PLE F14E002 GE SC174 YES DRF139F14E002H SA WA F
H G
4 b
IF15mCRN-009 REFUEL PLTF ASSY F15E003 STERN ROG SC174 YES DRFF00000022 DA WA F
H G
l i
IF16mC5H-01 DEF F STRG C0ffTAIN F16E009 GE SC151 YES 139F16E009H1 DA 1
F8 N
G i
L 1F16mRAH-025 POISON CtstTAIN F14E015 Bir SC151 YES DRF F14-00009-1 DA 1
F14 H
G IF16mRAH-09 FUEL RACHIIN VESSL)
F16E006 VOTAH SC174 DA F2 H
B U
t l
IF16mRAH-10 STRG RACHtCR&DEF FI F14E004 GE SC137 YES DRF F16-0003 DA 13 F3 H
G 1
IF16mRAN-11 NEN FUEL STRG RACNS F14E007 GE SC151 YES DRF F00-00002 DA WA F17 H
G 4/
IG33mFT012 DIFF PRESS TRANS G33N041 ROSEH0t#ff SC100 YES DRFA00-1084101H SAT 50 F
M F
t i
j O C3 = CONTROL BLOG P = PIPE HoutfTED SBT=SItELE FREQUENCY QUALIFICATI0H HILESTONES REVISIGH 11 - Jt24E 1983 CS = COLD SHUT 00lti PC =PRIllARY C0 LIT.
BIAXIAL TESTIts A = REEVALUATION C0!FLETE i
DA =DYt4AHIC AtlALYSIS PL = PEDESTAL SC =SEC0tOARY CotiT.
B = REQUEST FOR REQUAL OR BID ISSUED NOTE: NUtIDER IN l
~
F = FLOOR HOUNTED QP = QUALIFIED BY
/ = LOCATED ON CONT.
C =S/H REC 0ttlEtOATICit TOLILCO
' TYPE HTNG' COLUDIN IS A/ Ils =ll0T STAfIDBY PIPIls ANALYSIS HALL D = QUAL DOC RECEIVED QUANTITY OF ITEllS.
3 1
ItaTalIULTI-FREQUEHCY RH =RADilASTE T =ltA1H STH. TUtelEL E =HARDHARE ilODIFICATION REQ'D i
4 BIAXIAL TESTIls SA = STATIC ANALYSIS H =tlEITHER CS OR HS F = QUAL DOC APVD & FILED I
IIST=tIULTI-FREQUEllCY SAT =SIliGLE FREQUENCY G =SQRT PAPER ColFLETE V
SIllGLE AXIAL TESTIts SINGLE AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTION i
i 4
i
.,m STottE & HE"STE"? EtCIll6I EQUIPitEtiT (j)
COPPORATIcti RUtt CCTE 06/22/63 SHOREll i1 GE LIST
\\
RUti TIllE 13.51.22 GEriERAL ELECTRIC CAi[
JOB flut!DE 11600 1-50RT LILC3 DOCHEY 50-322 ACTIVE tiSSS QUALIFICATI0tl LEVEL 1150 ITEttSi PAGE 6 HARM EQUIPifEttT GE BLDG AVAIL QUAL QUAL TYPE SAFETY QUAL tlUt EER DESCRIP TIOtt to.
VEf00R ELEV IttSP REPT HETH FREQ ttitG f ullC STATUS IG33mTE020E TDPERATURE ELEMEtIT G33tt042 PYC0 PC97 YES DRFA00-01364 SA 100 P
H F
IG33mTE071 TEIPERATURE ELElfEtiT G33H016 PYC0 SC136 YES DRFA00-1084-91C SAT 60+
F6 H
F B
1G33 mTIllER HOTOR DRIVEt4 TILLER G33R616 1H11mPIL-601 REAC& CORE COOL DB H11P601 GE C8063 YES SAI-029QA80PA-B IDT 14 F
tlS.CS G
1H11mPIL-602 RHCU & RECIRC Bil H11P602 CE CB063 YES SAI-029QA80PA-B IDT 14 F
HS.CS F
1H11mPtL-603 REACTOR CGITROL B lillP603 GE CB063 YES SAI-029QA80PA-B fBT 14 F
HS.CS G
1H11mPtL-608 PHR RAFCE flEUT CA H11P608 GE C0063 YES HDT F
H B
1H11mPtL-609 TRIP SYS A RPS VB H11P609 GE CD063 YES SAI-0290A80PA-B ttDT 22 F
HS.CS G
IH11mPIL-611 Tl2IP SYS B RPS VD H11P611 GE CB063 YES SAI-029QA80PA-B I!BT 22 F
HS.CS G
IH11mPit-612 FH & RECIRC IllSTR H11P612 GE CB063 YES SAI-029QA80PA-B ttDT 19 F
N G
L 1H11mPIL-613 PROCESS ItiSTR CAD H11P613 GE C0063 YES SAI-029QA80PA-B llDT 14 F
lis.CS G
t 1H11mPtL-614 ftSS TDtP LH OET VB H11P614 GE CB063 YES SAI-029QA80PA-B ttBT 22 F
H G
,(
lil11mPIL-617 DIV'l RHR RELAY VB H11P617 GE CC044 YES SAI-029QA80PA-B HDT 19 F
flS.CS G
IH11mPIL-618 RHR RELAY VB H11P610 GE CD044 YES SAI-029QA80PA-B ltDT 19 F
flS.CS G
(
lilllePIL-620 llPCI RELAY VENT BD H11P620 GE CB044 YES SAI-029QA80PA-B llDT 14 F
G lil11mPtL-621 IC RELAY VERT ED H11P621 GE CD044 YES SAI-029QA00PA-B llDT 14 F
HS.CS G
b 11111mPIL-622 It0D ISO V RELAY VB H11P622 GE C0044 YES SAI-0290A80PA-B ltDT 21 F
CS G
lil11mPtL-623 OUTDD ISO V REL VB H11P623 GE CB044 YES SAI-0290A80PA-B 110T 21 F
CS G
~
A.
1H11mPIL-626 DIV 1 COR SP REL VB H11P626 GE CB044 YES SAI-029QA00PA-B IDT 14 F
CS G
CB =CollTROL BLDG P = PIPE HoutiTED SBT=SIttGl.E FREQUEllCY QUALIFICATI0tl llILESTOttES REVISICH 11 - JUllE 1983 CS = COLD SliUT Doll!I PC =PRIllART C0!IT.
DIAXIAL TESTItIG A =REEVALUATIO!I C0tiPLETE DA =DYritJIIC AllALYSIS PL = PEDESTAL SC =SEC0tIDARY C0 tit.
B = REQUEST FOR REQUAL OR BID ISSUED fl0TE: I AU:0ER Ill
~
F = FLOOR 1100tITED QP = QUALIFIED BY
/ = LOCATED Ott CotiT.
C =S/H RECCit:tENDATIOrl TOLILCO
' TYPE HTt:G' COLU:El IS
(
HS =110T STA!!DDY PIPIttS AtlALYSIS HALL 0 =GUAL DOC RECEIVED QUAFITITY OF ITElis.
IfDT=tfULTI-FREQUEt1CY RH =RADilASTE T =ltAIll STil. TUtttiEL E = fit.RDliARE 110DIFICATIC44 REQ'D DIAXIAL TESiltG SA -STATIC AtlALYSIS tl =tlEITHER CS OR HS F = QUAL DOC APVD & FILED llST=ItULT I-FR EQUEliCY SAT =SII;SLE FREQUEtICY G =SQRT PAPER C0rlPLETE U
SIllGLE AXIAL TESTIllG SillSLE AXIAL TESTIllG H = COPIES OF DOC TO DISTRIDUTIOtt V
\\'g
I
\\
l SHOREHAML241/4 GE LIST STCHE & HELSTER Et2INEERING CORPORATION RUN DATE 04/22/E3 l
JOB HUteE3 11300 1-50RT GENERAL ELECTRIC CATEGORY I EQUIPilE.4T LILC3 DOCHET 50-321 ACTIVE HSSS QUALIFICATI0tl LEVEL (150 ITDtS)
PAGE 7 3
RUti TIHE 13.51.22 MARK EQUIPitENT GE BLDG AVAIL QUAL QUAL TYPE SAFETY QUAL a
PAABER DESCRIPTION HO.
VEte0R ELEV IflSP REPT HETH FREq HTIE FUNC STATUS 1H11mPit-427 DIV 2 COR SP REL VB H11P427 GE CB044 YES SAI-029QA80PA-8 teT 14 F
CS G
/
1H11mPit-428 At/to SLOMM96 REL VB H11P428 GE CB044 YES SAI-0290A80PA-B PET 14 F
CS S
i I
1H11mPtL-431 AUTO DEPRESS H11P431 GE CB044 YES SAI-0290A80PA-B PST 14 F
CS G
/
IH11mPit-435 DIV 1 RAD HONITOR H11P435 GE
- 4043 VES SAI-029QA80PA-8 FBT 21 F
M G
.1H11mPtL-434 DIV 2 RAD H0HITOR H31P434 GE CB043 YES SAI-029QA80PA-B fBT 21 F
N G
1H11tPtL-454 HSIL LISPKCAGE M11P454 GE CB043 YES SAI-0290A80PA-B PST 19 F
N G
1H11mPtL-455 HISL LISHCAGE H11P455 GE C8043 YES SAI-029QA80PA-B IST 21 F
M G
J 1H21mPet-01 CORE SPRAY RH CH A H21P001 GE SC008 YES SAI-029QA80PA IST 11 F
CS G
)
Ilf21tPtL-02 RHCU SYSTEli IttST H21P002 GE SC151 YES SAI-029QA80PA FST 8
F M
G IH21mPtL-04 RX VES L & P RACH H21P004 GE SC079 YES SAI-0290A80PA fBT 8
F HS.CS G
i 1H21mPit-05 RX VES L & P RACM H21P005 GE SC079 YES SAI-029QA00PA teT 8
F HS.CS G
l
)
- -1H21mPtL-04 RECIRC PLAP A RAC H21P004 GE SC040 YES SAI-0290A80PA IST 11 F
M G
j lil21mPtL-09 JET PLAP A H21P009 GE SC079 YES SAI-029QA80PA fBT 11 F
H F
J IH21tPtL-10 JET PLAP INST RH H21P010 GE SC079 YES SAI-029QA80PA HDT 11 F
H F
lil21tPtL-14 HPCI It4ST RACM H21P014 GE SC008 YES SAI-029QA00PA IST 8
F M
G 1H21tPtL-15 HAIN STN FLON RH A H21P015 GE SC040 YES SAI-0290A00PA HDT 8
F N
G j
IH21tPtL-16 CS/HPCI LH DET I H21P014 CE SC006 YES SAI-029QA80PA IUT 11 F
H G
/
4 IH21sPtL-17 RCIC INST RACH H21P017 CE SC006 YES SAI-029QA80PA IDT 8
F HS G
}
IH21tPit-18 NHR INST RACM Cil H21P018 GE SC006 YES SAI-0290A80PA teT 8
F liS.CS S
J y CB C0ffTROL BLDG P : PIPE HOUNTED SBTzSINGLE FREQUEtlCY QUALIFICATION HILESTot4ES REVISION 11 - JUNE 1983 J
d CS zCOLD SHUT DOW4 PC PRIllARY CONT.
BIAXIAL TESTING A =REEVALUATI0tl CollPLE' '
! ~04 =DYHAHIC AllALYSIS PL PEDESTAL SC =SEC0tIDARY C0 tit.
B mR[ QUEST FOR REQUAL L. BID ISSUED tiOTE: taul: DER IN 3
F mFLc0R HOUNTED QP = QUALIFIED BY
/ zLOCATED ON CONT.
C zS/H RECol9tEllDATI0tt TOLILCO
' TYPE Hit 3G' COLttri IS HS zHGf STAtOBY PIPING AtlALYSIS HALL D zQUAL DOC RECEIVED QUAT (TITY OF ITEttS.
/
IIDT=IlULTI-FREQUEtlCY RH =RA0llASTE T =HAIN STH. TtRtlEL E =llAROHARE 11031FICATION REQ'D BIAXIAL TESTIrlG SA = STATIC AFIALYSIS N =t4EITHER CS OR HS F = QUAL DOC APVD & FILED i
itSTzHULTI-FREQUEllCY SAT =SIllGLC FREQUEt1CY G :SQRT PAPER C0ttPLETE SIllGLE AXIAL TESTIIE SItt0LE AXIAL TESTING L-H : COPIES OF DOC TO DISTRIBUTION
.)
L 1
9
8 t
y i
i
\\d
\\,.j
\\,s' SHOREttAll UNIT 1 GE LI3T ST0ftE & HEESTE~2 EtiGItiEC'IrlG CORPORATIOtt RUH DATE 06/22/;3 J00 IU DER 11600 1-SORT GEllERAL ELECTRIC CATEGORY I EQUIPilErlT RW4 TIttE 13.51.22 A
LILC'3 DOCl(ET 50-322 ACTIVE ttSSS QUALIFICATI0tl LEVELt150 ITElts)
PAGE 8 r
itARH EQUIPHEtti GE BLOG AVAIL QUAL QUAL TYPE SAFETY QUAL IU DER DESCRIPTI0tl 140.
VEtDOR ELEV IttSP REPT
!!ETH FREQ HitG FutlC STATUS
,(
IH21sPFL-19 CORE SPDAY RM CH H21P019 GE SC008 YES SAI-029QA30PA DDT 11 F
CS G
(
SAI-029QA80PA IDT 0
F HS.CS G
1H21mPIL-21 RitR IttST RACH CH ll21P021 GE SC006 YES s
lit 21mPtL-22 RECIRC PlJP B RAC H21P022 GE Scor40 YES SAI-0290A00PA IUT 6
F tl G
1H21:PFL-25 ftAIN STH FLOH RM ll21P025 GE SC040 YES SAI-029QA80PA HDT 11 F
H G
(
)
1H21 mPtL-26 RV LV & PRES RH H21P026 GE SC079 YES SAI-029QA80PA DUT 11 F
HS.CS G
IH21sPIL-30 SRH/IRH PREAPP RH H21P030 GE SC079 TES DRF A00-794-16 DDT 4
F H
G IH21tPfL-31 SRH/IRH PREtJP RH H21P031 GE SC079 YES DRF A00-794-16 IDT 4
F H
G lil21 sPIL-32 SRtl/IRH PREAIF RH H21P032 GE SC079 YES DRF A00-794-16 IDT 4
F st G
(
/
Ill21f. Pit-33 SRit/IRH PREAtP RH H21P033 GE SC079 YES DRF A00-794-16 IDT 4
F H
G lilZ1tPtL-34 IIPCI LEAM DET RH H21P034 GE SC008 YES SAI-029QA00PA HGT 2S F
H G
J lil21tPIL-35 CS/RCIC LH DET I H21P035 GE SC040 YES SAI-029QA00PA IDT 11 F
tl G
litt1cPIL-36 itPCI LEAM DET RH H21P036 GE SC008 YES SAI-029QA00PA DDT 11 F
H G
s IH21ePIL-37 RCIC LEAR DET RH H21P037 GE SC008 YES SAI-029QA80PA IDT 25 F
tl C
IH21aPfL-38 RCIC LEAN DET 9H H21P030 GE SC040 YES SAI-029QA80PA DDT 11 F
tt G
)
1H21rPtL-41 lit STEAll FLOli IR H21P041 CE SC040 YES SAI-0290ASOPA IDT 11 F
I!
G 1H211PtL-73 HSIV LEAHAGE RH H21P073 GE SC063 YES SAI-029QA80PA IDT 11 F
tl G
t J
1H211 Pit-74 HSIV LEAHAGE RH H21P074 GE SC063 YES SAI-029QABOPA IUT 8
F fl F
A U CQ =C0tiTROL BLDG P = PIPE HOUllTED SBT=SIttGLE FREQUEllCY QUALIFICATI0tt flILEST0 TIES REVISI0tt 11 - JUtIE 1903
')
CS COLD SilUT 00lti PC :PRIltARY C0rlT.
DIAXIAL TESTIIG A =REEVALUATI0tl CottPLETE
~
DA =DYt4 attic At4ALYSIS PL = PEDESTAL SC =SEC0tDARY C0ttT.
B = REQUEST FOR REQUAL OR BID ISSUED tiOTE: t1UtBER lti F = FLOOR tloutitED QP = QUALIFIED DY
/ = LOCATED Ott CottT.
C =S/H REC 0tt!EtiOATI0tl TOLILCO
' TYPE HTitG' COLUlta IS U ltS = HOT STAfDDY PIPItG AtlALYSIS IIALL D = QUAL DOC RECEIVED QUAtlTITY OF ITEttS.
J' ItDT at tULTI-F REQUEllCY RH =RADllASTE T =ItAIN STil. TuttlEL E =llARDHAPE IIODIFICATIOtt REQ'D DIAXIAL TESTIliG SA = STATIC AttALYSIS tt =tiLInlER CS OR HS F = QUAL DOC APVD & FILED tiST=ItULTI-FREQUEtICY SAT =SIttGLE FREQUEttCY G =SQRT PAPER CottPLETE U
SillGLE AXIAL TESTIllG SIllGLE AXIAL TESTIrlG 14 CDPIES OF DOC TO DISTRIBUTI0tl 5/
5 O
~J