MONTHYEARML20217E0371999-09-30030 September 1999 Application for Amend to License NPF-57,supporting Use of ABB-CE Fuel & Reload Analyses Beginning with Upcoming Cycle 10.Proprietary & non-proprietary Info Re Subject Amend,Encl. Proprietary Info Withheld,Per 10CFR2.790(a)(4) LR-N990357, Application for Amend to License NPF-57,to Change TS to Raise Condensate Storage Tank (CST) Low Level Setpoints & Corresponding Allowable Values Associated with Transfer of HPCI & RCIC Pump Suctions from CST to Suppression Pool1999-08-26026 August 1999 Application for Amend to License NPF-57,to Change TS to Raise Condensate Storage Tank (CST) Low Level Setpoints & Corresponding Allowable Values Associated with Transfer of HPCI & RCIC Pump Suctions from CST to Suppression Pool ML18107A3571999-06-0404 June 1999 Application for Amends to Licenses DPR-70,DPR-75 & NPF-57 Re Transfer of PSEG Ownership Interests & Licensed Operating Authorities to New,Affiliated Nuclear Generating Company, PSEG Nuclear Llc.Proprietary Encls Withheld ML20195B5461999-05-24024 May 1999 Application for Amend to License NPF-57,correcting Typos & Editorial Errors Contained in Ts.Corrections Are Considered to Be Administrative in Nature LR-N990137, Application for Amend to License NPF-57 to Revise TS to Include Oscillation Power Range Monitor (OPRM) Sys,In Preparation for Plans to Fully Enable OPRM Trip Function During Ninth Refueling Outage,Scheduled for Apr 22,20001999-05-17017 May 1999 Application for Amend to License NPF-57 to Revise TS to Include Oscillation Power Range Monitor (OPRM) Sys,In Preparation for Plans to Fully Enable OPRM Trip Function During Ninth Refueling Outage,Scheduled for Apr 22,2000 ML20206G0651999-03-29029 March 1999 Redistributed Application for Amend to License NPF-57, Incorporating Programmatic Controls in TS for Radioactive Effluents & for Environ Monitoring Conforming to Applicable Regulatory Requirements.Rev 18 to ODCM Also Encl ML20205E7931999-03-29029 March 1999 Application for Amend to License NPF-57,incorporating Programmatic Controls in TS for Radioactive Effluents & Environ Monitoring,Conforming to Applicable Regulatory Requirements ML20198T0131998-12-30030 December 1998 Application for Amend to License NPF-57,proposing Rev to Flood Protection TS LCO & Associated Action Statements ML20198N3901998-12-28028 December 1998 Application for Amend to License NPF-57,permitting Increase in Allowable Leak Rate for MSIVs & Deleting MSIV Sealing Sys LR-N980532, Application for Amend to License NPF-57,revising TS by Replacing Accelerated Testing Requirements of TS Table 4.8.1.2-1 with EDG Performance Monitoring & Delete TS 4.8.1.1.3 Requirement to Submit 30-day Special Rept1998-12-16016 December 1998 Application for Amend to License NPF-57,revising TS by Replacing Accelerated Testing Requirements of TS Table 4.8.1.2-1 with EDG Performance Monitoring & Delete TS 4.8.1.1.3 Requirement to Submit 30-day Special Rept ML20155D3441998-10-22022 October 1998 Application for Amend to License NPF-57,to Revise TS to Establish More Appropriate Minimum Battery Electrolyte Temperature Limits ML20154R5821998-10-19019 October 1998 Application for Amend to License NPF-57,eliminating Restrictions Imposed by TS 3.0.4 for Filtration, Recirculation & Ventilation Sys During Fuel Movement & Core Alteration Activities LR-N980363, Application for Amend to License NPF-57,permitting Use of non-class 1E Single Cell Battery Chargers,With Proper Electrical Isolation,For Charging Connected Cells in Operable Class 1E Batteries1998-09-0808 September 1998 Application for Amend to License NPF-57,permitting Use of non-class 1E Single Cell Battery Chargers,With Proper Electrical Isolation,For Charging Connected Cells in Operable Class 1E Batteries ML20151S4301998-08-25025 August 1998 Application for Amend to License NPF-57,implementing Appropriately Conservative SLMCPR for Upcoming Cycle 9 Plant Core & Fuel Designs.Proprietary & non-proprietary Description of Revs to TS Encl.Proprietary Info Withheld ML20236F1121998-06-25025 June 1998 Application for Amend to License NPF-57,deleting Requirement to Perform in-situ Functional Testing of ADS Valves Once Every 18 Months as Part of Startup Testing Activities ML20249A8101998-06-12012 June 1998 Application for Amend to License NPF-57,providing Increased Operational Flexibility During Periods of Elevated River Water Temp & Maintaining Ultimate Heat Sink Operation within Design.Engineering Analyses Also Encl ML20247K7301998-05-13013 May 1998 Application for Amend to License NPF-57,revising TS Inservice Leak & Hydrostatic Testing Requirements.Review Is Requested by 981220,to Support Next Refueling Outage ML20217P9221998-04-28028 April 1998 Application for Amend to License NPF-57,revising TS 3/4.4.2 by Implementing More Appropriate SRV Setpoints.Proprietary GE TR NEDC-32511P, Safety Review for Hope Creek SRV Tolerance Analysis, Encl.Proprietary Info Withheld LR-N970670, Application for Amend to License NPF-57,requesting Rev to App B of TS 4.2.2, Terrestrial Ecology Monitoring, by Rewording Section to Include Completion of Salt Drift Monitoring Program Which Was Completed in Mar 19891997-12-19019 December 1997 Application for Amend to License NPF-57,requesting Rev to App B of TS 4.2.2, Terrestrial Ecology Monitoring, by Rewording Section to Include Completion of Salt Drift Monitoring Program Which Was Completed in Mar 1989 LR-N970622, Application for Amend to License NPF-57,revising TS 3/4.11.1, Liquid Effluents - Concentration, by Adding Requirement to Perform Weekly Sampling & Monthly & Quarterly Composite Analyses of Ssws When Racs Is Contaminated1997-09-29029 September 1997 Application for Amend to License NPF-57,revising TS 3/4.11.1, Liquid Effluents - Concentration, by Adding Requirement to Perform Weekly Sampling & Monthly & Quarterly Composite Analyses of Ssws When Racs Is Contaminated LR-N970618, Application for Amend to License NPF-57,adding Surveillance Requirement in Section 3/4.5.1 to Perform Monthly Valve Position Verification for Each of Four Residual Heat Removal cross-tie Valves1997-09-24024 September 1997 Application for Amend to License NPF-57,adding Surveillance Requirement in Section 3/4.5.1 to Perform Monthly Valve Position Verification for Each of Four Residual Heat Removal cross-tie Valves ML20211M2571997-08-26026 August 1997 Sanitized Supplement to 970331 & 970716 Applications for Amend to License NPF-57,revising Ts.Addl Info & Revised TS Bases Pages Associated W/Amend 101 ML20217Q6641997-08-26026 August 1997 Application for Amend to License NPF-57,requesting Rev to TS to Clarify Plant Basis for Compliance W/Frvs TS Requirements ML20210P3341997-08-20020 August 1997 Application for Amend to License NPF-57,deleting References to Plants Suppression Pool Water Volume from TS & Supporting Planned Mods to ECCS Suction Strainers in Upcoming Refueling Outage,Per NRC Bulletin 96-003 ML20211M2451997-07-16016 July 1997 Sanitized Version of Supplement to 970331 Application for Amend to License NPF-57,revising TS & Providing Revised SLMCPR Values for Upcoming Operating Cycle (Cycle 8) ML20149G4271997-07-16016 July 1997 Supplements Application for Amend to License NPF-57, Submitted 970331.Supplement Provides Revised SLMCPR Values for Upcoming Operating Cycle (Cycle 8).TSs & Proprietary Info Re SLMCPR Changes,Encl.Proprietary Info,Withheld LR-N970217, Application for Amend to License NPF-7,revising Sections of TSs to Delete Reference to Rod Sequence Control Sys & Reduce Rod Worth Minimizer Low Power Setpoint from 20% to 10%1997-06-19019 June 1997 Application for Amend to License NPF-7,revising Sections of TSs to Delete Reference to Rod Sequence Control Sys & Reduce Rod Worth Minimizer Low Power Setpoint from 20% to 10% ML20141G8221997-05-19019 May 1997 Application for Amend to License NPF-57,revising Ultimate Heat Sink Temp & River Water Level Limits Which Resolve TS Related Issues Documented in Hope Creek Corrective Action Program ML20140F0261997-04-30030 April 1997 Application for Transfer of Control Re Operating License NPF-57 for Hcngs.Joint Proxy Statement/Prospectus Describing Details of Util Agreement & Plant of Merger W/Delmarva Power & Light Co,Encl LR-N970183, Application for Amend to License NPF-57,requesting Mod to Listed TSs to Adopt Option B of 10CFR50,App J1997-04-0101 April 1997 Application for Amend to License NPF-57,requesting Mod to Listed TSs to Adopt Option B of 10CFR50,App J ML20137M1061997-03-31031 March 1997 Application for Amend to License NPF-57,revising TS to Improve Consistency Between TS & Plant Configuration, Operation & Testing & Complete Required CA to Resolve TS Discrepancies Identified in CA Program ML20137M5811997-03-31031 March 1997 Application for Amend to License NPF-57,representing Changes to TS 2.1.2,action a.1.c for LCO 3.4.1.1 & Bases for TS 2.1. Info Re Safety Limit Min Critical Power Ratio Changes Encl. Info Withheld ML20135E8041997-03-0303 March 1997 Application for Amend to License NPF-57,changing TS 3/4.3.1, Reactor Protection Sys Instrumentation, 3/4.3.2, Isolation Actuation Instrumentation & 3/4.3.3, Emergency Core Cooling Sys Actuation Instrumentation ML20134M0771997-02-11011 February 1997 Application for Amend to License NPF-57,requesting Rev to 3/4.8 Re Electrical Power Systems for Improvements to EDG ML20134B5441997-01-24024 January 1997 Application for Amend to License NPF-57,changing TS 3.1.5, Control Rod Scram Accumulators ML20134F4231996-10-25025 October 1996 Application for Amend to License NPF-57,requesting Rev to 3.1.3.5 Re Control Rod Scram Accumulators ML20117K1231996-08-30030 August 1996 Application for Amend to License NPF-57,changing FSAR Decoupling SSE from LOCA ML18102A2541996-07-12012 July 1996 Suppls to Application for Amend to Licenses DPR-70,DPR-75 & NPF-57 Re Qualifications of Operations Manager ML20100R0841996-03-0606 March 1996 Application for Amend to License NPF-57,revising Diesel Fuel Oil Storage & Transfer Requirements ML18101B2501996-02-26026 February 1996 Application for Amends to Licenses DPR-70,DPR-75 & NPF-57, Revising TS Section 6.0 Re Administrative Controls of Plant ML20097C5671996-02-0505 February 1996 Application for Amend to License NPF-57,revising SR 4.6.2.2.b & 4.6.2.3.b to Include Flow Through RHR Heat Exchanger Bypass Line in SPC & Suppression Pool Spray Flow Path Used During RHR Pump Testing ML18101B1751996-01-11011 January 1996 Application for Amends to Licenses DPR-70,DPR-75 & NPF-57, Revising TS Section 6.0 Re Administrative Controls & Replacing Specific Mgt Titles W/Generic Mgt Functional Positions ML20099L6571995-12-28028 December 1995 Application for Amend to License NPF-57,revising TS Definition 1.4 Re Channel Calibr to Ensure Required Testing Methodology Aligns W/Std Industry Methodology for Instrument Channels Having T/C or RTD as Sensor ML20098D0011995-10-0707 October 1995 Application for Amend to License NPF-57,revising SR 4.8.1.1.2 Re Testing of EDGs to Be Consistent W/Applicable Licensing Documents Used for Development of EDG Surveillance ML20086T6991995-07-27027 July 1995 Application for Amend to License NPF-57,revising Ts,By Incorporating Updated Pressure Vs Temperature Operating Limit Curves Contained in TS Figure 3.4.6.1-1 ML20083B9591995-05-0404 May 1995 Application for Amend to App a of License NPF-57,increasing Annual Operational Limit for Drywell & Suppression Chamber Purge Sys from 120 H to 500 H ML20082T3351995-04-18018 April 1995 Application for Amend to License NPF-57,revising TS Table 4.3.7.1-1, Radiation Monitoring Instrumentation SRs by Extending Channel Functional Test Interval from Monthly to Quarterly for Each Instrument ML20082C1171995-03-30030 March 1995 Application for Amend to License NPF-57 for Hope Creek Generating Station.Amend Would Eliminate Selected Response Time Testing Requirements from TS & Associated Bases Changes ML20078C8351995-01-20020 January 1995 Application for Amend to License NPF-57,to Remove Specification from TSs & Relocates Bases to Plant UFSAR & Surveillance Requirements to Applicable Surveillance Procedures ML20078C8141995-01-20020 January 1995 Application for Amend to License NPF-57,to Revise Surveillance Requirement 4.1.3.1.2.b Re CR Immovable as Result of Excessive Friction or Mechanical Interference 1999-09-30
[Table view] Category:OPERATING LICENSES-APPLICATION FOR & AMENDMENTS
MONTHYEARML20024A7851983-06-28028 June 1983 Amended Application for Ol,For Hope Creek Generating Station,Unit 1 1983-06-28
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML20217E0371999-09-30030 September 1999 Application for Amend to License NPF-57,supporting Use of ABB-CE Fuel & Reload Analyses Beginning with Upcoming Cycle 10.Proprietary & non-proprietary Info Re Subject Amend,Encl. Proprietary Info Withheld,Per 10CFR2.790(a)(4) ML20212H0601999-09-21021 September 1999 Amend 123 to License NPF-57,revising TSs to Correct typo- Graphical & Editorial Errors & Considered Administrative in Nature ML20212C1181999-09-17017 September 1999 Amend 122 to License NPF-57,revising TS Limiting Condition for Operation 3.7.3 & TS Table 3.7.3-1.Changes Modify Flood Protection Actions Required When Severe Storm Warnings That May Effect Site in Effect ML20211N5471999-09-0808 September 1999 Amend 121 to License NPF-57 Revising TSs by Locating Procedural Details of RETS to Offsite Dose Calculation Manual LR-N990357, Application for Amend to License NPF-57,to Change TS to Raise Condensate Storage Tank (CST) Low Level Setpoints & Corresponding Allowable Values Associated with Transfer of HPCI & RCIC Pump Suctions from CST to Suppression Pool1999-08-26026 August 1999 Application for Amend to License NPF-57,to Change TS to Raise Condensate Storage Tank (CST) Low Level Setpoints & Corresponding Allowable Values Associated with Transfer of HPCI & RCIC Pump Suctions from CST to Suppression Pool ML18107A3571999-06-0404 June 1999 Application for Amends to Licenses DPR-70,DPR-75 & NPF-57 Re Transfer of PSEG Ownership Interests & Licensed Operating Authorities to New,Affiliated Nuclear Generating Company, PSEG Nuclear Llc.Proprietary Encls Withheld ML20195B5461999-05-24024 May 1999 Application for Amend to License NPF-57,correcting Typos & Editorial Errors Contained in Ts.Corrections Are Considered to Be Administrative in Nature LR-N990137, Application for Amend to License NPF-57 to Revise TS to Include Oscillation Power Range Monitor (OPRM) Sys,In Preparation for Plans to Fully Enable OPRM Trip Function During Ninth Refueling Outage,Scheduled for Apr 22,20001999-05-17017 May 1999 Application for Amend to License NPF-57 to Revise TS to Include Oscillation Power Range Monitor (OPRM) Sys,In Preparation for Plans to Fully Enable OPRM Trip Function During Ninth Refueling Outage,Scheduled for Apr 22,2000 ML20205P7621999-04-14014 April 1999 Amend 119 to License NPF-57,revising TS Surveillance Requirements 4.8.1.1.2 & 4.8.1.1.3,Table 4.8.1.1.2-1 & Associated Bases ML20206G0651999-03-29029 March 1999 Redistributed Application for Amend to License NPF-57, Incorporating Programmatic Controls in TS for Radioactive Effluents & for Environ Monitoring Conforming to Applicable Regulatory Requirements.Rev 18 to ODCM Also Encl ML20205E7931999-03-29029 March 1999 Application for Amend to License NPF-57,incorporating Programmatic Controls in TS for Radioactive Effluents & Environ Monitoring,Conforming to Applicable Regulatory Requirements ML20205D3591999-03-25025 March 1999 Amend 118 to License NPF-57,revising TS 4.8.2.1.b.3 to Increase Minimum Battery Electrolyte Temp Limit from 60 F to 72 F ML20205G3721999-03-0909 March 1999 Amend 117 to License NPF-57,revising TS 2.1.2 & Bases for TS 2.1 ML20203F8761999-02-10010 February 1999 Amend 115 to License NPF-57,revising TS 3.4.2.1 to Replace Plus/Minus 1% Setpoint Tolerance Limit for Safety Relief Safety Relief Valves with a Plus/Minus 3% Setpoint Tolerance Limit ML20203F6961999-02-0909 February 1999 Amend 114 to License NPF-57,revises App C, Addl Conditions & Will Allow Performance of Single Cell Charging & Use of non-Class 1E Single Cell Battery Chargers with Proper Electrical Isolation,For Charging Connected Cells ML20203C7741999-02-0404 February 1999 Amend 113 to License NPF-57,changing TSs in Response to 981019 Application Re Elimination of TS 3.0.4 Restrictions for Filtration,Recirculation & Ventilation Sys During Fuel Movement & Core Alteration Activities ML20198T0131998-12-30030 December 1998 Application for Amend to License NPF-57,proposing Rev to Flood Protection TS LCO & Associated Action Statements ML20198N3901998-12-28028 December 1998 Application for Amend to License NPF-57,permitting Increase in Allowable Leak Rate for MSIVs & Deleting MSIV Sealing Sys LR-N980532, Application for Amend to License NPF-57,revising TS by Replacing Accelerated Testing Requirements of TS Table 4.8.1.2-1 with EDG Performance Monitoring & Delete TS 4.8.1.1.3 Requirement to Submit 30-day Special Rept1998-12-16016 December 1998 Application for Amend to License NPF-57,revising TS by Replacing Accelerated Testing Requirements of TS Table 4.8.1.2-1 with EDG Performance Monitoring & Delete TS 4.8.1.1.3 Requirement to Submit 30-day Special Rept ML20195C5531998-11-12012 November 1998 Corrected TS Page 3/4 3-8 to Amend 26 to License NPF-57, Corrects Two Typographical Errors on TS Table 4.3.1.1-1. First Error Was Inadvertent Omission of Left Hand Bracket in Channel Functional Test Column of Table ML20155D3441998-10-22022 October 1998 Application for Amend to License NPF-57,to Revise TS to Establish More Appropriate Minimum Battery Electrolyte Temperature Limits ML20154R5821998-10-19019 October 1998 Application for Amend to License NPF-57,eliminating Restrictions Imposed by TS 3.0.4 for Filtration, Recirculation & Ventilation Sys During Fuel Movement & Core Alteration Activities ML20154B6621998-10-0101 October 1998 Amend 112 to License NPF-57,revising TS 3/4.10.8, Inservice Leak & Hydrostatic Testing, to Delete Requirement for Operable High Drywell Pressure Trip Function LR-N980363, Application for Amend to License NPF-57,permitting Use of non-class 1E Single Cell Battery Chargers,With Proper Electrical Isolation,For Charging Connected Cells in Operable Class 1E Batteries1998-09-0808 September 1998 Application for Amend to License NPF-57,permitting Use of non-class 1E Single Cell Battery Chargers,With Proper Electrical Isolation,For Charging Connected Cells in Operable Class 1E Batteries ML20151S4301998-08-25025 August 1998 Application for Amend to License NPF-57,implementing Appropriately Conservative SLMCPR for Upcoming Cycle 9 Plant Core & Fuel Designs.Proprietary & non-proprietary Description of Revs to TS Encl.Proprietary Info Withheld ML20236F1121998-06-25025 June 1998 Application for Amend to License NPF-57,deleting Requirement to Perform in-situ Functional Testing of ADS Valves Once Every 18 Months as Part of Startup Testing Activities ML20249A8101998-06-12012 June 1998 Application for Amend to License NPF-57,providing Increased Operational Flexibility During Periods of Elevated River Water Temp & Maintaining Ultimate Heat Sink Operation within Design.Engineering Analyses Also Encl ML20247K7301998-05-13013 May 1998 Application for Amend to License NPF-57,revising TS Inservice Leak & Hydrostatic Testing Requirements.Review Is Requested by 981220,to Support Next Refueling Outage ML20247L1461998-05-0808 May 1998 Amend 111 to License NPF-57,changing Wording of Section 4.2.2, Terrestrial Ecology Monitoring ML20217P9221998-04-28028 April 1998 Application for Amend to License NPF-57,revising TS 3/4.4.2 by Implementing More Appropriate SRV Setpoints.Proprietary GE TR NEDC-32511P, Safety Review for Hope Creek SRV Tolerance Analysis, Encl.Proprietary Info Withheld LR-N970670, Application for Amend to License NPF-57,requesting Rev to App B of TS 4.2.2, Terrestrial Ecology Monitoring, by Rewording Section to Include Completion of Salt Drift Monitoring Program Which Was Completed in Mar 19891997-12-19019 December 1997 Application for Amend to License NPF-57,requesting Rev to App B of TS 4.2.2, Terrestrial Ecology Monitoring, by Rewording Section to Include Completion of Salt Drift Monitoring Program Which Was Completed in Mar 1989 ML20199C1981997-11-0606 November 1997 Amend 109 to License NPF-57,adding Surveillance Requirement to TS 3/4.5.1 to Perform Monthly Valve Position Verification for Four Residual Heat Removal cross-tie Valves ML20199C2531997-11-0606 November 1997 Amend 110 to License NPF-57,changing TS to Provide for Relocation of Suppression Chamber Volume References in Limiting Condition for Operation 3.5.3 to Hope Creek Updated FSAR & TS Bases as Appropriate ML20199C1411997-11-0606 November 1997 Amend 108 to License NPF-57,changes TS 3/4.11.1, Liquid Effluent-Concentration. Change Adds Requirement to Perform Weekly Sampling & Monthly & Quarterly Composite Analyses of Station Service Water Sys ML20199F4551997-11-0404 November 1997 Amend 107 to License NPF-57,changing TS 2.1.2, Thermal Power,High Pressure & High Flow, Action a.1.c for TS 3.4.1.1, Recirculation Loops, & Bases for TS 2.1, Safety Limit ML20211K0741997-09-30030 September 1997 Amend 105 to License NPR-57,changing TS 4.1.3.1.2, Control Rod Operability, TS 3.1.3.6, Control Rod Drive Coupling, TS 3.1.3.7, Control Rod Position Indications & TS 3.1.4.1, Rod Worth Minimizer LR-N970622, Application for Amend to License NPF-57,revising TS 3/4.11.1, Liquid Effluents - Concentration, by Adding Requirement to Perform Weekly Sampling & Monthly & Quarterly Composite Analyses of Ssws When Racs Is Contaminated1997-09-29029 September 1997 Application for Amend to License NPF-57,revising TS 3/4.11.1, Liquid Effluents - Concentration, by Adding Requirement to Perform Weekly Sampling & Monthly & Quarterly Composite Analyses of Ssws When Racs Is Contaminated LR-N970618, Application for Amend to License NPF-57,adding Surveillance Requirement in Section 3/4.5.1 to Perform Monthly Valve Position Verification for Each of Four Residual Heat Removal cross-tie Valves1997-09-24024 September 1997 Application for Amend to License NPF-57,adding Surveillance Requirement in Section 3/4.5.1 to Perform Monthly Valve Position Verification for Each of Four Residual Heat Removal cross-tie Valves ML20217C1891997-09-18018 September 1997 Amend 104 to License NPF-57,changing TS 4.6.1.1, Primary Containment Integrity, 3/4.6.1.2, Primary Containment Leakage, 3/4.6.1.3, Primary Containment Air Locks, & 4.6.1.5.1, Primary Containment Structural Integrity ML20211E6831997-09-16016 September 1997 Amend 103 to License NPF-57,changes TS 3/4.8.4.2, MOV-TOP (Bypassed), to Relocate List of Applicable Valves (TS Table 3.8.4.2-1) to Plant UFSAR ML20211M2571997-08-26026 August 1997 Sanitized Supplement to 970331 & 970716 Applications for Amend to License NPF-57,revising Ts.Addl Info & Revised TS Bases Pages Associated W/Amend 101 ML20217Q6641997-08-26026 August 1997 Application for Amend to License NPF-57,requesting Rev to TS to Clarify Plant Basis for Compliance W/Frvs TS Requirements ML20210P3341997-08-20020 August 1997 Application for Amend to License NPF-57,deleting References to Plants Suppression Pool Water Volume from TS & Supporting Planned Mods to ECCS Suction Strainers in Upcoming Refueling Outage,Per NRC Bulletin 96-003 ML20217H2541997-07-24024 July 1997 Amend 101 to License NPF-57,changing Plant TSs 3/4.3.1, Reactor Protection Sys Instrumentation, TS 3/4.3.2, Isolation Actuation Instrumentation, & TS 3/4.3.3, ECCS Actuation Instrumentation ML20149G4271997-07-16016 July 1997 Supplements Application for Amend to License NPF-57, Submitted 970331.Supplement Provides Revised SLMCPR Values for Upcoming Operating Cycle (Cycle 8).TSs & Proprietary Info Re SLMCPR Changes,Encl.Proprietary Info,Withheld ML20211M2451997-07-16016 July 1997 Sanitized Version of Supplement to 970331 Application for Amend to License NPF-57,revising TS & Providing Revised SLMCPR Values for Upcoming Operating Cycle (Cycle 8) ML20149D8611997-07-0909 July 1997 Amend 99 to License NPF-57,changing TS Section 3.6.5.3.2, Filtration,Recirculation & Ventilation Sys, to Provide Appropriate LCO & Action Statement That Reflects Design Basis for Filtration,Recirculation & Ventilation Sys LR-N970217, Application for Amend to License NPF-7,revising Sections of TSs to Delete Reference to Rod Sequence Control Sys & Reduce Rod Worth Minimizer Low Power Setpoint from 20% to 10%1997-06-19019 June 1997 Application for Amend to License NPF-7,revising Sections of TSs to Delete Reference to Rod Sequence Control Sys & Reduce Rod Worth Minimizer Low Power Setpoint from 20% to 10% ML20141G8221997-05-19019 May 1997 Application for Amend to License NPF-57,revising Ultimate Heat Sink Temp & River Water Level Limits Which Resolve TS Related Issues Documented in Hope Creek Corrective Action Program ML20140F0261997-04-30030 April 1997 Application for Transfer of Control Re Operating License NPF-57 for Hcngs.Joint Proxy Statement/Prospectus Describing Details of Util Agreement & Plant of Merger W/Delmarva Power & Light Co,Encl 1999-09-08
[Table view] |
Text
. - -
i O
BEFORE THE 1
UNITED STATES NUCLEAR REGULATORY COMMISSION DOCKET NO. 50-354 4
IN THE MATTER OF 4
PUBLIC SERVICE ELECTRIC AND GAS COMPANY i
- l ATLANTIC CITY ELECTRIC COMPANY I
i APPLICATION FOR AN OPERATING LICENSE UNDER THE ATOMIC ENERGY ACT OF 1954 AS AMENDED I
l l
FOR HOPE CREEK GENERATING STATION O
swwe?a*=%
A
., ~.._....__ a.
... _..,, -.. _..... _ _... ~.. _,. _ _
O BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION DOCKET NO. 50-354 IN THE MATTER OF PUBLIC SERVICE ELECTRIC AND GAS COMPANY ATLANTIC CITY ELECTRIC COMPANY APPLICATION FOR AN OPERATING LICENSE On November 4,1974, the Atomic Energy Commission, predecessor to the Nuclear Regulatory Commission ("NRC"), issued Construction Permit No. CPPR-120 to Public Service Electric and Gas Company and Atlantic City Electric Company for the Hope Creek Generating Station. In accordance with the Atomic Energy Act of 1954, as amended, and the rules and regulations issued thereunder in Title 10, Code of Federal Regulations, Public Service Electric and Gas Company on its own behalf and on behalf of Atlantic City Electric Company, as their interests are hereinaf ter set forth 9
(" Applicants"), hereby makes application for a forty year Class 103 license as measured from its date of issuance to operate a nuclear electric generating unit to be located on Applicants' Hope Creek site in Lower Alloways Creek Township, Salem County, New Jersey. The facility will be known as " Hope Creek Generating Station". Public Service
/
Electric and Gas Company also applies for appropriate source, special nuclear and by-(
r,.,
- a product materials and other appropriate licenses for the project for a term consistent with the related Class 103 operating license. Public Service Electric and Gas Company retains exclusive responsibility for the licensing, design, procurement, operation, maintenance, and all related functions with respect to the facility and will act as agent for the owners in connection with all aspects of NRC licensing and regulation. A description of the facility is contained in the Final Safety Analysis Report ("FSAR") and Environmental Report - Operating License Stage ("EROL"), submitted herewith.
This application consists of (a) the general information required by 10 C.F.R.
Section 50.33, which is set out herein; (b) the technical information and safety analysis report required by 10 C.F.R. Part 50, especially Section 50.34, which is set out in a separate document entitled, " Hope Creek Generating Station Final Safety Analysis
'N Report," forwarded herewith and made a part hereof; (c) an Environmental Report entitled, " Hope Creek Generating Station Environmental Report - Operating License Stage," as required by 10 C.F.R. Section 50.30 (f) and 10 C.F.R. Part $1 forwarded herewith and made a part hereof; (d) the Hope Creek Emergency Plan forwarded herewith and made a part hereof; (e) the Hope Creek Security Plan and the Hope Creek Safeguards Contingency Plan forwarded under separate cover but made a part hereof; and (f) a separate document entitled, "Information for Antitrust Review of Operating License Application."
l l
General Iniormation l
A.
General Information required by 10 C.F.R. Section 50.33:
l l
1.
Name of Applicants The Applicants are Public Service Electric and Gas Company, for itself, as owner of an undivided 95% interest in the facility, and as agent for Atlantic City
(.
l Electric Company, which will own an undivided 5% interest in the f acility.
l 2.
Address of Applicants Public Service Electric and Gas Company 80 Park Plaza P.O. Box 570 Newark, New Jersey 07101 Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, New Jersey 08232 3.
Description of Business and Organization of Public Service Electric and Gas Company and Atlantic City Electric Company Public Service Electric and Gas Company Public Service Electric and Gas Company is a public utility. It is engaged in the generation, manufacture, purchase, transmission, distribution and sale of electricity and gas. Its service area extends approximately from the Hudson River opposite New York to the Delaware River at Trenton and thence to Camden, New Jersey.
Atlantic City Electric Company Atlantic City Electric Company is a public utility. It is engaged in the generation, transmission, distribution and sale of electricity.
Its service area encompasses the southern portion of New Jersey.
4.
Directors and Principal Of ficers All directors and principal officers of Public Service Electric and Gas Company are citizens of the United States of America. Their names and addresses are l
as follows:
[d e----n,e~,--
~~-,+~v-=~
~ - <
w
~~w=
r-~
wm--
O Directors of Public Service Electric and Gas Company Name Address Dr. James R. Cowan President United Hospitals Medical Center 15 South Ninth Street Newark, New Jersey 07107 T. 3. Dermot Dunphy President.
Sealed Air Corporation Park 80 Plaza East Saddle Brook, New Jersey 07662 Robert R. Ferguson, Jr.
President First National State Bancorporation 350 Broad Street a
Newark, New Jersey 07102 O
Miss Margery Somers Foster Francestown, New Hampshire 03043 Irwin Lerner President Hoffman-LaRoche, Inc.
Nutley, New Jersey 07110 William E. Marfuggi Chairman of the Board Victory Optical Manufacturing Co.
One Victory Plaza Newark, New Jersey 07102 Mrs. Marilyn M. Pf altz P and R Associates 382 Springfield Avenue Summit, New Jersey 07901 James C. Pitney Pitney, Hardin, Kipp & Szuch 163 Madison Avenue Morristown, New Jersey 07960 l
O
.m.
,_,m-_.
r-
w Directors of Public Service Electric and Gas Company Name Address Dr. Kenneth C. Rogers President Stevens Institute of Technology Hoboken, New Jersey 07030 Verdell L. Roundtree 609 Belvidere Avenue Plainfield, New Jersey 07062 William E. Scott Executive Vice President -
Finance Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Robert 1. Smith Chairman of the Board Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Harold W. Sonn President Public Service Electric and Gas Company 80 Park Plaza Newar,k, New Jersey 07101 Robert V. Van Fossan Chairman of the Board The Mutual Benefit Life Insurance Company 520 Broad Street Newark, New Jersey 07101 O
. ~. - ~, - -
. q U
Principal Officers of Public Service Electric and Gas Company Name Address Robert I. Smith Chairman of the Board Chief Executive Officer Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Harold W. Sonn President and Chief Operating Officer Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 William E. Scott Executive Vice President - Finance Public Service Electric and Gas Company, 80 Park Plaza s
Newark, New Jersey 07101 James B. Randel, Jr.
Senior Vice President and President of Energy Development Corporation Public Service Electric
' and Gas Company 80 Park Plaza Newark, New Jersey 07101 Stephen A. Mallard Senior Vice President - Planning and Research and President of PSE&G Res9 arch Corporation Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Richard M. Eckert Senior Vice President - Energy Supply and Engineering Public Service Electric i
and Gas Company 80 Park Plaza Newark, New Jersey 07101 O
- - ~-
Principal Officers of Public Service Electric and Gas Company Name Address Robert W. Lockwood Senior Vice President -
Administration Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Everett L. Morris Senior Vice President -
Customer Operations Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Frederick W. Schneider
- Senior Vice President -
Corporate Planning Public Service Electric O,
and Gas Company 80 Park Plaza Newark, New Jersey 07101 Donald A. Anderson Vice President - Computer Systems and Services Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Lawrence R. Codey Vice P, resident and Corporate Rate Counsel Public Service Electric and Gas Company 80 Park Plaza Nswark, New Jersey 07101 Robert M. Crockett Vice President - Fuel Supply Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 y
O
. (h t)
Principal Officers of Public Service Electric and Gas Company Name Address Fredrick R. DeSanti Vice President - Rates and Load Management Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Robert H. Franklin Vice President -
Public Relations Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Carroll D. James Vice President -
Administrative Planning Public Service Electric p/
and Gas Company s_
80 Park Plaza Newark, New Jersey 07101 Frank P. Librizzi Vice President - Production Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Charles E. Maginn, Jr.
Vice President - Human Resources Public, Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Wallace A. Maginn Vice President and Treasurer Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 l
Winthrop E. Mange, Jr.
Vice President -
Corporate Services Public Service Electric O
and Gas Company 80 Park Plaza Newark, New Jersey 07101 7
1
_9_
J Principal Officers of Public Service Electric and Gas Company Name Ad_ dress Thomas J. Martin Vice President - Engineering and Construction Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Parker C. Peterman Vice President and Comptroller Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Louis L. Rizzi Vice President - Customer and Marketing Services Public Service Electric O
and Gas Company 80 Park Plaza Newark, New Jersey 07101 William Saller Vice President -
Governmental' Affairs Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Robert J. Selbach Vice President - Transmission and' Distribution Public Service Electric ano Gas Company 80 Park Plaza Newark, New Jersey 07101 R. Edwin Selover Vice President and General Counsel l
Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 O
I
- Principal Officers of Public Service Electric and Cas Company Name Address Rudolph D. Stys Vice President -
System Planning Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Richard A. Uderitz Vice President - Nuclear Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038 Robert S. Smith Secretary Public Service Electric and Gas Company O
80 Park Plaza V
Newark, New Jersey 07101 All directors and principal officers of Atlantic City Electric Company are citizens of the United States of America. Their names and addresses are as follows:
Directors of Atlantic City Electric Company Name Address Mrs. Eleanor S. Daniel 34 North Drive East Brunswick, N.J. 08816 Mr. Richard M. Dicke Simpson Thacher & Bartlett One Battery Park Plaza -34th Floor New York, New York 10004 Mr. John D. Feehan Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 O
__ O Directors of Atlantic City Electric Compmy Name Address Mr. Jos. Michael Galvin, Jr.
Salem County Memorial Hospital Salem, New Jersey 08079 Mr. Matthew Holden, Jr.
6544 Hitt Avenue McLean, Virginia 22101 Mr. Mack C. Jones 6240 Mariner Sands Drive Stuart, Florida 33494 Mr. Irving K. Kessler 1733 Country Club Drive Cherry Hill, New Jersey 08003 l
Mr. Alfred C. Linkletter 73 Orchard Road Chatham, N.J. 07928 Mr. John M. Miner, Crocker National Bank Crocker Center O
Suite 880 333 South Grand Avenue Los Angeles, CA 90071 1
Mr. Frank H. Wheaton, Jr.
Wheaton Glass Company Millville, N.J. 08332 Mr. Richard M. Wilson 103 Circle Drive Northfield, N.J. 08225 Principal Officers of Atlant_ic City Electric Company Name Address John D. Feehan President and Chief Executive Officer Atlantic City Electric Company i
1199 Blackhorse Pike l
Pleasantville, N.J. 08232 Frank J. Ficadenti Senior Vice President - Engineering and Construction Atlantic City Electric Company O
1199 Blackhorse Pike L>
Pleasantville, N.J. 08232 r
-y m.,
.,r_.
y
(
Principal Officers of Atlantic City Electric Company Name Address Ernest D. Huggard Senior Vice President - Operations Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 Jerrold L. Jacobs Senior Vice President - Finance Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 Michael A. Jarrett Senior Vice President - Corporate Services Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 David V. Boney Vice President - Customer and Community Services Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 John F. Born Vice President - Electric Operations Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 Thomas E. Freeman Vice President - Human Resources Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 Brian A. Parent Vice President and Treasurer l
Atlantic City Electric Company l
1199 Blackhorse Pike Pleasantville, N.J. 08232 Joseph G. Salomone Vice President - Control Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 Henry C. Schwemm, Jr.
Vice President - Production Atlantic City Electric Company v
1199 Blackhorse Pike Pleasantville, N.J. 08232 Principal Officers of Atlantic City Electric Company Name Address Martin R. Meyer Secretary and Assistant Treasurer Atlantic City Electric Company 1199 Blackhorse Pike.
Pleasantville, N.J. 08232 Lance E. Cooper Controller Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 Joseph T. Kelly Assistant Vice President -Operations and Assistant Secretary Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 Meredith I. Harlacher Assistant Vice President -Information Services Atlantic City Electric Company 1199 Blackhorse Pike Pleasantville, N.J. 08232 5.
Absance of Foreign Control Public Service Electric and Gas Company and Atlantic City Electric Company are not owned, controlled, or dominated by an alien, a foreign corporation or foreign government.
i e
(
6.
Applicant is Acting as Agent or Representative Public Service Electric and Gas Company, acting on its own behalf and as agent for Atlantic City Electric Company, hereby applies for such permits and licenses as may be necessary or appropriate to the acquisition, use, possession, and operation of O
O l
Hope Creek Generating Station, as described in this application.
i l
l l
.. _ _ k 7.
Class and Period of License Requested PublW Service Electric and Gas Company requests a Class 103 operating license for a period of forty (40) years measured from the date of its issuance for the Hope Creek Generating Station.
Public Service Electric and Gas Company also requests such additional source, special nuclear, and by-product material licenses as may be necessary and appropriate to the operation of the plant. Applicants have combined its application for these licenses in this single application pursuant to 10 C.F.R. Section 50.31.
8.
Description of Facility and Use to Which Facility Will be Put Applicants propose to operate a single cycle, forced circulation, boiling water nuclear reactor for the generation of commercial electric energy with an operational capacity of approximately 3293 megawatts thermal and an estimated net 1067 megawatts electrical. Details concerning the plant, the site, and the attendant environmental considerations are contained in the FSAR and the EROL, which constitute part of this application.
9.
Completion Dates The current earliest and latest completion dates for Hope Creek Generating Station as contained in the construction permit are as follows:
Earliest Completion Latest Completion i
Date Date l
December 12,1980 December 31,1986 J
,r.
,--,---~,.7,,---,,--,....r-n,-
,,--,,en,.,
-._,..-v,
~.-- -,~
10.
Regulatory Agencies Regulatory agencies which may have jurisdiction over the rates and services incident to the proposed generation, sale and distribution of electric energy of the owners are:
a.
The Federal Energy Regulatory Commission b.
State of New Jersey Department of Energy Board of Public Utilities 11.
Trade and News Publications The following is a list of trade and news publications which circulate in the area in which the operation of the Hope Creek Generating Station will be conducted and which are considered appropriate to give reasonable notice of this application to those m) municipalities, private utilities, public bodies and cooperatives which might have a potential interest in the Hope Creek Generating Station:
Trade and News Publications Dover Delaware State News Atlantic City Press P.O. Box 737 1900 Atlantic Ave.
Webbs Lane Atlantic City, N.J. 08401 Dover, Delaware 19901 Wilmington News Journal Bridgeton News P.O. Box 1111 100 E. Commerce Street 831 Orange Street Bridgeton, N.J. 08302 Wilmington, Delaware 19899 Today's Sunbeam Elmer Times 95 5th Street 21 State Street Salem, N.J. 08079 Elmer, N.J. 08318 l
Vineland Times-Journal Glassboro Enterprise 409 39th Street Clam-Glo Newspapers Vineland, N.J. 07087 P.O. Box 67 Blackwood, N.J. 08012 Penns Grove Record P.O. Box 20 Salem, N.J. 08079 v
V O 12.
Restricted Data (Sections 50.33(i) and 50.37)
This application does not involve any Restricted Data or other classified information (defense information) and it is not expected that any will become involved. If it does, it will be appropriately segregated and safeguarded as required by law.
Applicants agree that they will not permit any individual to have access to Restricted Data until the Office of Personnel Management shall have made an investigation and report to the Nuclear Regulatory Commission on the character, associations, and loyalty of such individual, and the Nuclear Regulatory Commission shall have determined that permitting such person to have access to Restricted Data will not endanger the common defense and security.
14.
Combined Application With regard to iniormation required by 10 C.F. R. 30.32,40.31, or 70.22 of NRC Regulations and Forms NRC-2 and NRC-313, Applicants hereby adopt and incorporate by reference the information contained in this application for an operating license for Hope Creek Generating Station.
t l
l O
..---o.
w-a n....-,-.=vn.
--r
.--rwan.,v,,-,n-~.
r,--v,,,r,ww, p-w,-n*,,,,w,-r--,,v-.--wm,..-nwn,en-,-~,,,,..,-n-ennwer,---w-,--w,w-n-
.. _ _ _. 15.
All communications to Applicants pertaining to this Application shall be sent to:
Robert L. Mitti General Manager Nuclear Assurance & Regulation 80 Park Plaza - Tif.0 P.O. Box 570 Newark, New Jersey 07101 and Troy B. Conner, Jr., Esq.
Conner & Wetterhahn, P.C.
Suite 1050 1747 Pennsylvania Avenue, N.W.
Washington, D.C. 20006 O
i PUBLIC SERVICE ELECTRIC AND GAS COMPANY
{
By E&
((
Tfiom'as J. Mart)tf l
Vice President (/ Engineering and Construction 1
O f
e
4 7m.
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of
)
)
Public Service Electric
) Docket No. 50-354 and Gas Company
)
)
(Hope Creek Generating
)
Station)
)
AFFIDAVIT Thomas J. Martin, being duly sworn states that he is Vice President of Public Service Electric and Gas Company; that he is authorized on the part of said Corporation to sign and file with the Nuclear Regulatory Commission the documents attached hereto; and that all such documents are true and correct to the best of his knowledge, information and belief.
h,s%
Subscribed and sworn to before me, a Notary Public in and for the State of New Jersey and County of ISM.7
,this 2
day of N74
,1983.