ML20023D815

From kanterella
Jump to navigation Jump to search
Ack Receipt of in Response to NRC Re IE Insp Rept 50-286/82-09.Effective Coverage by radial-type Nozzle Not Addressed in Safety Evaluation.Addl Info Requested 830228 Not Received
ML20023D815
Person / Time
Site: Indian Point 
Issue date: 05/23/1983
From: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
Shared Package
ML20023D816 List:
References
NUDOCS 8306030343
Download: ML20023D815 (2)


See also: IR 05000286/1982009

Text

,

a . . .

May 23, 1983

Docket No. 50-286

Power Authority of the State of New York

-

Indian Point 3 Nuclear Power Plant

ATTN: Mr. J. C. Brons

.

P.esident Manager

P. O. Box 215

Buchanan, New York 10511

Gentlemen:

.

Subject:

Inspection 50-286/82-09

_

This refers to your letter dated January 28, 1983, in response to our letter

dated November 4, 1982.

Thank you for the information provided in your letter.

Your evaluation of the installed radial type sprinkler nozzle, concludes that the

coverage provided by the installed nozzle is equal to or superior to a system

utilizing the horizontal side-wall type nozzle. We agree that the EA-1 radial

'

type sprinkler nozzle has adequate capacity, however, it is not apparent in your

safety evaluation that our concern regarding the effective coverage by the radial

type nozzle has been addressed.

The use of the horizontal side-wall nozzle was specified because of the narrow

horizontal spacing between trays (6 inches) and the need to direct the water spray

horizontally between the trays. The concern pertains to the structural interference

by the top and bottom tray which reduces the effective spray cone by obstructing the

top and bottom half of the spray cone thus reducing the amount of water available

for distribution along the horizontal length of the tray.

This concern was discussed with Mr. J. Schivera, IP-3, Licensing Coordinator, o.,

February 28, 1983. We were informed that a supplement to your memo of January 28,

1983 would be submitted clarifying the issue. We have not received this supplement

to-date.

We request that you submit the required information so that we may determine the

acceptability of the as-installed configuration.

Your cooperation with us is appreciated.

Sincerely,

3egouq) *o 'S

--

%q pou6 g geuts90

t

homas T. Martin, Director

'

Division of Engineering and

Technical Programs

8306030343 830523

gDRADOCK 05000286

.

m

.

@ul

,

.

~

4

..

4

Power [AuthorityLof the -State of'NY-

2

-

.

cc:

.

.

.

L. W. Sinclair, President. and Chief Operating Officer

-

J. P. Bayne~, Executive Vice President-Nuclear Generation

.C.' M. Pratt, Assistant General Counsel

~.

A. Klausmann, Vice President - Quality Assurance :

D. Halama, Quality Assurance Superintendent

.

G. M.- Wilverding, Chairman, Safety Review Committee

K. Bu'rke, Director, Regulatory Affairs. (Con Ed)

NRC Licensing Project Manager

Dept. .of Public Service, State of New York

Public Document Room (PDR)

Local Public Document Room (LPDR)

--

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New York

bcc: w/ encl

Region I Docket Room.

Section Chief, DPRP

0FFICIAL RECORD COPY

DETP

DETP

ETP

~ ' '

Paolino

Anderson

Ebneter

gfg 'g6

G 4y , 13

!

'

L