U.S. NUCLEAR REGULATORY COMMISSION REGION I Report No. 70-371/83-05 Docket No.70-371 License No. SNM4 38 Licensee: United Nuclear Corporation 67 Sandy Desert Road Un.casville, CT F4cility Name: UNC Naval products Inspection At: Uncasville, CT Inspection Conducted: April 11-15, 1983 Date of Last Material Control and Accounting Inspe tion: March 21-25, 1983 Type of Inspection: Announced Material Control and Accounti_nj Inspectors:

' 444*'M

/

b / T-E3 H. Zibulsiky Ghemist L

date

$ A'lY l Y 6~/f"f3 A. Della Rat a\\ Auditor date Approved by:

/

s F-J A. T.' Goby, Chief feguards Section

' dat6 Inspection Summary:

Inspection on April 11-15, 1983 (Report No. 70-371/83-05)

Area Inspected:

Inventory Verification. The inspection involved 63 inspector-hours onsite by two NRC inspectors and was begun during the regular hours.

Results: The licensee was in compliance with NRC requirements in the area examined during the inspection.

8306030324 830520 PDR ADOCK 07000371 C

PDR

. ~.

1 DETAILS 1.

Key Persons Contracted

  • T. Collopy, Manager, Nuclear Safeguards
  • A. Wolvendyk, Supervisor, Nuclear Material Control M. Kelly, Statistician The inspectors also interviewed other licensee personnel involved in the control and accounting of special nuclear material.
  • Present at 'xit interview.

2.

30703 - Exit Interview The inspectors met with the licensee representatives (denoted in paragraph 1) at the conclusion of the inspection on April 15, 1983, and summarized the scope and findings of the inspection.

3.

85213 - Inventory Verification No viciations were identified.

The inspection results were obtained by performing an independent verification of the U-235 content of three populations of containers of feed material located within the storage area of MBA-1. Only containers with mcre than 500 grams of material were measured. A 100% sampling of Types IV and V feed material was made, consisting of 102 measurements.

Two hundred and sixty-six samples of Type III material were also measured.

For all the samples measured, an accept / reject criterion for the determination of a defect was chosen.

Each of the sariple items selected was weighed and gamma counted for 10 seconds using a b-SAM III. The results of the test indicated that, of the samples met.sured, there were no gross defects. A gross defect was defined as a difference greater than 20% between the stated and the measured contents of an item.

-